Abstract

Purpose

During wound healing after surgery, physiological inflammation leads to an increase in soft tissue perfusion. This is reflected by a characteristic temperature course in the skin. Although local surgical trauma also influences soft tissue perfusion, no data have been available on the regional temperature distribution after knee arthroplasty to date. This study aims at testing the hypothesis that the greatest regional difference in the temperature course is on the site of the maximum surgical trauma (medially) after knee arthroplasty implantation. This is to our knowledge the first study to present regional differences in the temperature course after TKA which would limit the diagnostic value of thermography.

Methods

Forty-two subjects who were to receive a surface replacement of the knee joint due to primary varus gonarthrosis were included in the study. In all cases, a medial parapatellar approach was chosen. Patients who underwent lateral release or a release of the lateral ligament structures were excluded. In all patients, a thermographic temperature determination was carried out on the operated knee joint every day up to the seventh post-operative day.

Results

On the medial side, there was no significant change in temperature between day one 34.9° ± 0.2° (34.6–35.3 °C) and seven after surgery. Thereafter, the temperature remained constant here up to the seventh day after the operation. In contrast to this, on the lateral side there was an increase in skin temperature from the second 35.0 ± 0.2 °C (34.7–35.4 °C) to the fifth 34.6° ± 0.2° (34.1–34.9 °C) post-operative day (p = 0.002). Thereafter, the temperature remained constant here up to the seventh day after the operation.

Conclusion

This study refutes the hypothesis that the greatest regional difference in the temperature course is on the site of maximum surgical trauma (medially) after knee arthroplasty implantation. It is shown to the contrary that there is the least regional difference in the temperature course on the site of maximum surgical trauma (medially) after total knee arthroplasty implantation. It is on the site of the minimal trauma (laterally) where marked differences in the temperature course appeared. The normal temporary temperature increase typical of physiological wound healing could only be shown at a distance from the site of soft tissue preparation. This may be the result of a local compromise of perfusion. Consequently, the post-operative diagnostic application of thermography remains limited to regions distant from the surgical site. This may prevent misinterpretation of post-operative thermographic measurements for scientific or clinical reasons.

Level of evidence

II.
Literature
1.
go back to reference Alcelik I, Sukeik M, Pollock R, Misra A, Shah P, Armstrong P, Dhebar MI (2012) Comparison of the minimally invasive and standard medial parapatellar approaches for primary total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 20:2502–2512CrossRefPubMed Alcelik I, Sukeik M, Pollock R, Misra A, Shah P, Armstrong P, Dhebar MI (2012) Comparison of the minimally invasive and standard medial parapatellar approaches for primary total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 20:2502–2512CrossRefPubMed
2.
go back to reference Aso K, Ikeuchi M, Izumi M, Kato T, Tani T (2012) Transcutaneous oxygen tension in the anterior skin of the knee after minimal incision total knee arthroplasty. Knee 19:576–579CrossRefPubMed Aso K, Ikeuchi M, Izumi M, Kato T, Tani T (2012) Transcutaneous oxygen tension in the anterior skin of the knee after minimal incision total knee arthroplasty. Knee 19:576–579CrossRefPubMed
3.
go back to reference Choudhry RR, Rice RP, Triffitt PD, Harper WM, Gregg PJ (1992) Plasma viscosity and C-reactive protein after total hip and knee arthroplasty. J Bone Jt Surg Br 74:523–524 Choudhry RR, Rice RP, Triffitt PD, Harper WM, Gregg PJ (1992) Plasma viscosity and C-reactive protein after total hip and knee arthroplasty. J Bone Jt Surg Br 74:523–524
4.
go back to reference Haidar SG, Charity RM, Bassi RS, Nicolai P, Singh BK (2006) Knee skin temperature following uncomplicated total knee replacement. Knee 13:422–426CrossRefPubMed Haidar SG, Charity RM, Bassi RS, Nicolai P, Singh BK (2006) Knee skin temperature following uncomplicated total knee replacement. Knee 13:422–426CrossRefPubMed
5.
go back to reference Hazenberg CEVB, van Netten JJ, van Baal SG, Bus SA (2014) Assessment of signs of foot infection in diabetes patients using photographic foot imaging and infrared thermography. Diabet Technol Ther 16:370–377CrossRef Hazenberg CEVB, van Netten JJ, van Baal SG, Bus SA (2014) Assessment of signs of foot infection in diabetes patients using photographic foot imaging and infrared thermography. Diabet Technol Ther 16:370–377CrossRef
6.
go back to reference Honsawek S, Deepaisarnsakul B, Tanavalee A, Sakdinakiattikoon M, Ngarmukos S, Preativatanyou K, Bumrungpanichthaworn P (2011) Relationship of serum IL-6, C-reactive protein, erythrocyte sedimentation rate, and knee skin temperature after total knee arthroplasty: a prospective study. Int Orthop 35:31–35CrossRefPubMed Honsawek S, Deepaisarnsakul B, Tanavalee A, Sakdinakiattikoon M, Ngarmukos S, Preativatanyou K, Bumrungpanichthaworn P (2011) Relationship of serum IL-6, C-reactive protein, erythrocyte sedimentation rate, and knee skin temperature after total knee arthroplasty: a prospective study. Int Orthop 35:31–35CrossRefPubMed
7.
go back to reference Horzić M, Marić K, Bunoza D (1995) The temperature dynamics during the healing processing of a surgical wound. Biomed Tech (Berl) 40:106–109CrossRef Horzić M, Marić K, Bunoza D (1995) The temperature dynamics during the healing processing of a surgical wound. Biomed Tech (Berl) 40:106–109CrossRef
8.
go back to reference Ishii Y, Noguchi H, Takeda M, Higashihara T-I (2009) A new tourniquet system that determines pressures in synchrony with systolic blood pressure in knee surgery. Knee Surg Sports Traumatol Arthrosc 17:48–52CrossRefPubMed Ishii Y, Noguchi H, Takeda M, Higashihara T-I (2009) A new tourniquet system that determines pressures in synchrony with systolic blood pressure in knee surgery. Knee Surg Sports Traumatol Arthrosc 17:48–52CrossRefPubMed
9.
go back to reference Johnson DP (1988) Midline or parapatellar incision for knee arthroplasty. A comparative study of wound viability. J Bone Jt Surg Br 70:656–658 Johnson DP (1988) Midline or parapatellar incision for knee arthroplasty. A comparative study of wound viability. J Bone Jt Surg Br 70:656–658
10.
go back to reference Kliot DA, Birnbaum SJ (1965) Thermographic studies of wound healing. Am J Obstet Gynecol 93:515–521CrossRefPubMed Kliot DA, Birnbaum SJ (1965) Thermographic studies of wound healing. Am J Obstet Gynecol 93:515–521CrossRefPubMed
11.
go back to reference Lambiris E, Stoboy H (1981) Thermography in osteosyntheses and total endoprostheses of the knee joint with and without infection (author’s transl). Z Orthop Ihre Grenzgeb 119:521–524CrossRefPubMed Lambiris E, Stoboy H (1981) Thermography in osteosyntheses and total endoprostheses of the knee joint with and without infection (author’s transl). Z Orthop Ihre Grenzgeb 119:521–524CrossRefPubMed
12.
go back to reference Larsson S, Thelander U, Friberg S (1992) C-reactive protein (CRP) levels after elective orthopedic surgery. Clin Orthop Relat Res 275:237–242 Larsson S, Thelander U, Friberg S (1992) C-reactive protein (CRP) levels after elective orthopedic surgery. Clin Orthop Relat Res 275:237–242
13.
go back to reference Mehra A, Langkamer VG, Day A, Harris S, Spencer RF (2005) C reactive protein and skin temperature post total knee replacement. Knee 12:297–300CrossRefPubMed Mehra A, Langkamer VG, Day A, Harris S, Spencer RF (2005) C reactive protein and skin temperature post total knee replacement. Knee 12:297–300CrossRefPubMed
14.
go back to reference Neĭkov GN, Mingazov IT (1993) Comparative assessment of methods in early diagnosis of acute hematogenic osteomyelitis in children. Klin Khir 3:47–49 Neĭkov GN, Mingazov IT (1993) Comparative assessment of methods in early diagnosis of acute hematogenic osteomyelitis in children. Klin Khir 3:47–49
15.
go back to reference Ring EF (1987) Thermographic and scintigraphic examination of the early phase of inflammatory disease. Scand J Rheumatol Suppl 65:77–80CrossRefPubMed Ring EF (1987) Thermographic and scintigraphic examination of the early phase of inflammatory disease. Scand J Rheumatol Suppl 65:77–80CrossRefPubMed
16.
go back to reference Ring EFJ (2004) The historical development of thermal imaging in medicine. Rheumatol (Oxford) 43:800–802CrossRef Ring EFJ (2004) The historical development of thermal imaging in medicine. Rheumatol (Oxford) 43:800–802CrossRef
17.
go back to reference Robicsek F, Masters TN, Daugherty HK, Cook JW, Selle JG, Hess PJ, Vajtai P (1984) The value of thermography in the early diagnosis of postoperative sternal wound infections. Thorac Cardiovasc Surg 32:260–265CrossRefPubMed Robicsek F, Masters TN, Daugherty HK, Cook JW, Selle JG, Hess PJ, Vajtai P (1984) The value of thermography in the early diagnosis of postoperative sternal wound infections. Thorac Cardiovasc Surg 32:260–265CrossRefPubMed
18.
go back to reference Romanò CL, D’Anchise R, Calamita M, Manzi G, Romanò D, Sansone V (2013) Value of digital telethermography for the diagnosis of septic knee prosthesis: a prospective cohort study. BMC Musculoskelet Disord 14:7CrossRefPubMedPubMedCentral Romanò CL, D’Anchise R, Calamita M, Manzi G, Romanò D, Sansone V (2013) Value of digital telethermography for the diagnosis of septic knee prosthesis: a prospective cohort study. BMC Musculoskelet Disord 14:7CrossRefPubMedPubMedCentral
19.
go back to reference Romanò CL, Logoluso N, Dell’Oro F, Elia A, Drago L (2012) Telethermographic findings after uncomplicated and septic total knee replacement. Knee 19:193–197CrossRefPubMed Romanò CL, Logoluso N, Dell’Oro F, Elia A, Drago L (2012) Telethermographic findings after uncomplicated and septic total knee replacement. Knee 19:193–197CrossRefPubMed
20.
go back to reference Romanò CL, Romanò D, Dell’Oro F, Logoluso N, Drago L (2011) Healing of surgical site after total hip and knee replacements show similar telethermographic patterns. J Orthop Traumatol 12:81–86CrossRefPubMedPubMedCentral Romanò CL, Romanò D, Dell’Oro F, Logoluso N, Drago L (2011) Healing of surgical site after total hip and knee replacements show similar telethermographic patterns. J Orthop Traumatol 12:81–86CrossRefPubMedPubMedCentral
21.
go back to reference Thienpont E, Grosu I, Jonckheere S, Yombi JC (2013) C-reactive protein (CRP) in different types of minimally invasive knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 21:2603–2610CrossRefPubMed Thienpont E, Grosu I, Jonckheere S, Yombi JC (2013) C-reactive protein (CRP) in different types of minimally invasive knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 21:2603–2610CrossRefPubMed
22.
go back to reference White J, Kelly M, Dunsmuir R (1998) C-reactive protein level after total hip and total knee replacement. J Bone Jt Surg Br 80:909–911CrossRef White J, Kelly M, Dunsmuir R (1998) C-reactive protein level after total hip and total knee replacement. J Bone Jt Surg Br 80:909–911CrossRef
Metadata
Title
Regional differences in temperature course after knee arthroplasty
Authors
Christoph Windisch
Steffen Brodt
Eric Roehner
Georg Matziolis
Publication date
01-08-2016
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 8/2016
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-015-3809-z

Other articles of this Issue 8/2016

Knee Surgery, Sports Traumatology, Arthroscopy 8/2016 Go to the issue