Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 2/2015

01-02-2015 | Shoulder

Arthroscopic double-row cuff repair with suture-bridging: a structural and functional comparison of two techniques

Authors: P. Boyer, C. Bouthors, T. Delcourt, O. Stewart, F. Hamida, G. Mylle, P. Massin

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 2/2015

Login to get access

Abstract

Purpose

The aim of this study was to compare the functional and structural outcomes of 2 techniques for double-row, suture-bridging cuff repair.

Methods

A consecutive series of 73 patients who underwent arthroscopic, double-row, suture-bridge primary rotator cuff repair of full-thickness supraspinatus tear were evaluated. Thirty-eight shoulders were repaired by the arthroscopic, tied, suture-bridging technique (group A), and 35 shoulders by knot-less bridging with suture tape material (group B). Constant scores, pain, range of motion, strength, and complications were measured after a minimum follow-up period of 12 months post-operatively. Structural integrity of the repairs was evaluated systematically by either magnetic resonance imaging or computed tomography arthrography.

Results

Median follow-up after surgery was 29 (23–32) months in group A, and 21 (12–23) months in group B. Mean pain relief, range of motion, strength, and constant score improved significantly in both groups. No statistical differences were found between groups in the post-operative period. According to control imaging, the re-tear rate trended to be higher in group A (23.4 %) than in group B (17.1 %), although not significantly.

Conclusion

Both bridging repair techniques achieved successful functional outcomes. In terms of structural outcome, the knot-less tape-bridging construct showed a lower but not significant re-tear rate. Longer follow-up is needed to confirm these results and to evaluate potential differences between the two techniques.

Level of evidence

A prospective, non-randomized, comparative study, Level III.
Literature
1.
go back to reference Bateman JE (1963) The diagnosis and treatment of ruptures of the rotator cuff. Surg Clin North Am 43:1523–1530PubMed Bateman JE (1963) The diagnosis and treatment of ruptures of the rotator cuff. Surg Clin North Am 43:1523–1530PubMed
2.
go back to reference Behrens SB, Bruce B, Zonno AJ, Paller D, Green A (2012) Initial fixation strength of transosseous-equivalent suture bridge rotator cuff repair is comparable with transosseous repair. Am J Sports Med 40(1):133–140PubMedCrossRef Behrens SB, Bruce B, Zonno AJ, Paller D, Green A (2012) Initial fixation strength of transosseous-equivalent suture bridge rotator cuff repair is comparable with transosseous repair. Am J Sports Med 40(1):133–140PubMedCrossRef
3.
go back to reference Cho NS, Lee BG, Rhee YG (2011) Arthroscopic rotator cuff repair using a suture bridge technique: is the repair integrity actually maintained? Am J Sports Med 39(10):2108–2116PubMedCrossRef Cho NS, Lee BG, Rhee YG (2011) Arthroscopic rotator cuff repair using a suture bridge technique: is the repair integrity actually maintained? Am J Sports Med 39(10):2108–2116PubMedCrossRef
4.
go back to reference Christoforetti JJ, Krupp RJ, Singleton SB, Kissenberth MJ, Cook C, Hawkins RJ (2012) Arthroscopic suture—bridge transosseus equivalent fixation of rotator cuff tendon pre-serves intratendinous blood flow at the time of initial fixation. J Should Elbow Surg 21(4):523–530CrossRef Christoforetti JJ, Krupp RJ, Singleton SB, Kissenberth MJ, Cook C, Hawkins RJ (2012) Arthroscopic suture—bridge transosseus equivalent fixation of rotator cuff tendon pre-serves intratendinous blood flow at the time of initial fixation. J Should Elbow Surg 21(4):523–530CrossRef
5.
go back to reference Dehaan AM, Axelrad TW, Kaye E, Silvestri L, Puskas B, Foster TE (2012) Does double-row rotator cuff repair improve functional outcome of patients compared with single- row technique? A systematic review. Am J Sports Med 40(5):1176–1185PubMedCrossRef Dehaan AM, Axelrad TW, Kaye E, Silvestri L, Puskas B, Foster TE (2012) Does double-row rotator cuff repair improve functional outcome of patients compared with single- row technique? A systematic review. Am J Sports Med 40(5):1176–1185PubMedCrossRef
6.
go back to reference El-Azab H, Buchmann S, Beitzel K, Waldt S, Imhoff AB (2010) Clinical and structural evaluation of arthroscopic double-row suture-bridge rotator cuff repair: early results of a novel technique. Knee Surg Sports Traumatol Arthrosc 18(12):1730–1737PubMedCrossRef El-Azab H, Buchmann S, Beitzel K, Waldt S, Imhoff AB (2010) Clinical and structural evaluation of arthroscopic double-row suture-bridge rotator cuff repair: early results of a novel technique. Knee Surg Sports Traumatol Arthrosc 18(12):1730–1737PubMedCrossRef
7.
go back to reference Frank JB, ElAttrache NS, Dines JS, Blackburn A, Crues J, Tibone JE (2008) Repair site integrity after arthroscopic transosseous-equivalent suture-bridge rotator cuff repair. Am J Sports Med 36(8):1496–1503PubMedCrossRef Frank JB, ElAttrache NS, Dines JS, Blackburn A, Crues J, Tibone JE (2008) Repair site integrity after arthroscopic transosseous-equivalent suture-bridge rotator cuff repair. Am J Sports Med 36(8):1496–1503PubMedCrossRef
8.
go back to reference Gerber C, Schneeberger AG, Beck M, Schlegel U (1994) Mechanical strength of repairs of the rotator cuff. J Bone Joint Surg Br 76(3):371–380PubMed Gerber C, Schneeberger AG, Beck M, Schlegel U (1994) Mechanical strength of repairs of the rotator cuff. J Bone Joint Surg Br 76(3):371–380PubMed
9.
go back to reference Goutallier D, Postel JM, Bernageau J, Lavau L, Voisin MC (1994) Fatty muscle degeneration in cuff ruptures. Pre- and postoperative evaluation by CT scan. Clin Orthop Relat Res 304:78–83PubMed Goutallier D, Postel JM, Bernageau J, Lavau L, Voisin MC (1994) Fatty muscle degeneration in cuff ruptures. Pre- and postoperative evaluation by CT scan. Clin Orthop Relat Res 304:78–83PubMed
10.
go back to reference Goutallier D, Postel JM, Van Driessche S, Voisin MC (2005) Histological lesions of supraspinatus tendons in full thickness tears of the rotator cuff. Rev Chir Orthop Repara Trice Appar Mot 91(2):109–113CrossRef Goutallier D, Postel JM, Van Driessche S, Voisin MC (2005) Histological lesions of supraspinatus tendons in full thickness tears of the rotator cuff. Rev Chir Orthop Repara Trice Appar Mot 91(2):109–113CrossRef
11.
go back to reference Kim DH, Elattrache NS, Tibone JE, Jun BJ, DeLaMora SN, Kvitne RS, Lee TQ (2006) Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair. Am J Sports Med 34(3):407–414PubMedCrossRef Kim DH, Elattrache NS, Tibone JE, Jun BJ, DeLaMora SN, Kvitne RS, Lee TQ (2006) Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair. Am J Sports Med 34(3):407–414PubMedCrossRef
12.
go back to reference Kim JR, Cho YS, Ryu KJ, Kim JH (2012) Clinical and radiographic outcomes after arthroscopic repair of massive rotator cuff tears using a suture bridge technique: assessment of repair integrity on magnetic resonance imaging. Am J Sports Med 40(4):786–793PubMedCrossRef Kim JR, Cho YS, Ryu KJ, Kim JH (2012) Clinical and radiographic outcomes after arthroscopic repair of massive rotator cuff tears using a suture bridge technique: assessment of repair integrity on magnetic resonance imaging. Am J Sports Med 40(4):786–793PubMedCrossRef
13.
go back to reference Kim KC, Rhee KJ, Shin HD, Kim YM (2007) A modified suture-bridge technique for a marginal dog-ear deformity caused during rotator cuff repair. Arthroscopy 23(5):561 e562–561 e564 Kim KC, Rhee KJ, Shin HD, Kim YM (2007) A modified suture-bridge technique for a marginal dog-ear deformity caused during rotator cuff repair. Arthroscopy 23(5):561 e562–561 e564
14.
go back to reference Kim KC, Shin HD, Lee WY, Han SC (2012) Repair integrity and functional outcome after arthroscopic rotator cuff repair: double-row versus suture-bridge technique. Am J Sports Med 40(2):294–299PubMedCrossRef Kim KC, Shin HD, Lee WY, Han SC (2012) Repair integrity and functional outcome after arthroscopic rotator cuff repair: double-row versus suture-bridge technique. Am J Sports Med 40(2):294–299PubMedCrossRef
15.
go back to reference Lafosse L, Brozska R, Toussaint B, Gobezie R (2007) The outcome and structural integrity of arthroscopic rotator cuff repair with use of the double-row suture anchor technique. J Bone Joint Surg Am 89(7):1533–1541PubMedCrossRef Lafosse L, Brozska R, Toussaint B, Gobezie R (2007) The outcome and structural integrity of arthroscopic rotator cuff repair with use of the double-row suture anchor technique. J Bone Joint Surg Am 89(7):1533–1541PubMedCrossRef
16.
go back to reference Maguire M, Goldberg J, Bokor D, Bertollo N, Pelletier MH, Harper W, Walsh WR (2011) Biomechanical evaluation of four different transosseous-equivalent/suture bridge rota-tor cuff repairs. Knee Surg Sports Traumatol Arthrosc 19(9):1582–1587PubMedCrossRef Maguire M, Goldberg J, Bokor D, Bertollo N, Pelletier MH, Harper W, Walsh WR (2011) Biomechanical evaluation of four different transosseous-equivalent/suture bridge rota-tor cuff repairs. Knee Surg Sports Traumatol Arthrosc 19(9):1582–1587PubMedCrossRef
17.
go back to reference Meier SW, Meier JD (2006) Rotator cuff repair: the effect of double-row fixation on three-dimensional repair site. J Should Elbow Surg 15(6):691–696CrossRef Meier SW, Meier JD (2006) Rotator cuff repair: the effect of double-row fixation on three-dimensional repair site. J Should Elbow Surg 15(6):691–696CrossRef
18.
go back to reference Mihata T, Watanabe C, Fukunishi K, Ohue M, Tsujimura T, Fujiwara K, Kinoshita M (2011) Functional and structural outcomes of single-row versus double-row versus combined double-row and suture-bridge repair for rotator cuff tears. Am J Sports Med 39(10):2091–2098PubMedCrossRef Mihata T, Watanabe C, Fukunishi K, Ohue M, Tsujimura T, Fujiwara K, Kinoshita M (2011) Functional and structural outcomes of single-row versus double-row versus combined double-row and suture-bridge repair for rotator cuff tears. Am J Sports Med 39(10):2091–2098PubMedCrossRef
19.
go back to reference Nassos JT, Elattrache NS, Angel MJ, Tibone JE, Limpisvasti O, Lee TQ (2012) A watertight construct in arthroscopic rotator cuff repair. J Should Elbow Surg 21(5):589–596CrossRef Nassos JT, Elattrache NS, Angel MJ, Tibone JE, Limpisvasti O, Lee TQ (2012) A watertight construct in arthroscopic rotator cuff repair. J Should Elbow Surg 21(5):589–596CrossRef
20.
go back to reference Park MC, Elattrache NS, Ahmad CS, Tibone JE (2006) “Transosseous-equivalent” rotator cuff repair technique. Arthroscopy 22 (12):1360 e1361–1360 e1365 Park MC, Elattrache NS, Ahmad CS, Tibone JE (2006) “Transosseous-equivalent” rotator cuff repair technique. Arthroscopy 22 (12):1360 e1361–1360 e1365
21.
go back to reference Patte D (1990) Classification of rotator cuff lesions. Clin Orthop Relat Res 254:81–86PubMed Patte D (1990) Classification of rotator cuff lesions. Clin Orthop Relat Res 254:81–86PubMed
22.
go back to reference Pauly S, Kieser B, Schill A, Gerhardt C, Scheibel M (2010) Biomechanical comparison of 4 double-row suture-bridging rotator cuff repair techniques using different medial-row configurations. Arthroscopy 26(10):1281–1288PubMedCrossRef Pauly S, Kieser B, Schill A, Gerhardt C, Scheibel M (2010) Biomechanical comparison of 4 double-row suture-bridging rotator cuff repair techniques using different medial-row configurations. Arthroscopy 26(10):1281–1288PubMedCrossRef
23.
go back to reference Pennington WT, Gibbons DJ, Bartz BA, Dodd M, Daun J, Klinger J, Popovich M, Butler B (2010) Comparative analysis of single-row versus double-row repair of rotator cuff tears. Arthroscopy 26(11):1419–1426PubMedCrossRef Pennington WT, Gibbons DJ, Bartz BA, Dodd M, Daun J, Klinger J, Popovich M, Butler B (2010) Comparative analysis of single-row versus double-row repair of rotator cuff tears. Arthroscopy 26(11):1419–1426PubMedCrossRef
24.
go back to reference Pietschmann MF, Frohlich V, Ficklscherer A, Gulecyuz MF, Wegener B, Jansson V, Muller PE (2009) Suture anchor fixation strength in osteopenic versus non-osteopenic bone for rotator cuff repair. Arch Orthop Trauma Surg 129(3):373–379PubMedCrossRef Pietschmann MF, Frohlich V, Ficklscherer A, Gulecyuz MF, Wegener B, Jansson V, Muller PE (2009) Suture anchor fixation strength in osteopenic versus non-osteopenic bone for rotator cuff repair. Arch Orthop Trauma Surg 129(3):373–379PubMedCrossRef
25.
go back to reference Sethi PM, Noonan BC, Cunningham J, Shreck E, Miller S (2010) Repair results of 2-tendon rotator cuff tears utilizing the transosseous equivalent technique. J Should Elbow Surg 19(8):1210–1217CrossRef Sethi PM, Noonan BC, Cunningham J, Shreck E, Miller S (2010) Repair results of 2-tendon rotator cuff tears utilizing the transosseous equivalent technique. J Should Elbow Surg 19(8):1210–1217CrossRef
26.
go back to reference Spang JT, Buchmann S, Brucker PU, Kouloumentas P, Obst T, Schroder M, Burgkart R, Imhoff AB (2009) A biomechanical comparison of 2 transosseous-equivalent double-row rotator cuff repair techniques using bio-absorbable anchors: cyclic loading and failure behavior. Arthroscopy 25(8):872–879PubMedCrossRef Spang JT, Buchmann S, Brucker PU, Kouloumentas P, Obst T, Schroder M, Burgkart R, Imhoff AB (2009) A biomechanical comparison of 2 transosseous-equivalent double-row rotator cuff repair techniques using bio-absorbable anchors: cyclic loading and failure behavior. Arthroscopy 25(8):872–879PubMedCrossRef
27.
go back to reference Sugaya H, Maeda K, Matsuki K, Moriishi J (2005) Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual-row fixation. Arthroscopy 21(11):1307–1316PubMedCrossRef Sugaya H, Maeda K, Matsuki K, Moriishi J (2005) Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual-row fixation. Arthroscopy 21(11):1307–1316PubMedCrossRef
28.
go back to reference Sugaya H, Maeda K, Matsuki K, Moriishi J (2007) Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair. A prospective outcome study. J Bone Joint Surg Am 89(5):953–960PubMedCrossRef Sugaya H, Maeda K, Matsuki K, Moriishi J (2007) Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair. A prospective outcome study. J Bone Joint Surg Am 89(5):953–960PubMedCrossRef
29.
go back to reference Thomazeau H, Boukobza E, Morcet N, Chaperon J, Langlais F (1997) Prediction of rotator cuff repair results by magnetic resonance imaging. Clin Orthop Relat Res 344:275–283PubMedCrossRef Thomazeau H, Boukobza E, Morcet N, Chaperon J, Langlais F (1997) Prediction of rotator cuff repair results by magnetic resonance imaging. Clin Orthop Relat Res 344:275–283PubMedCrossRef
30.
go back to reference Toussaint B, Schnaser E, Bosley J, Lefebvre Y, Gobezie R (2011) Early structural and functional outcomes for arthroscopic double-row transosseous-equivalent rotator cuff repair. Am J Sports Med 39(6):1217–1225PubMedCrossRef Toussaint B, Schnaser E, Bosley J, Lefebvre Y, Gobezie R (2011) Early structural and functional outcomes for arthroscopic double-row transosseous-equivalent rotator cuff repair. Am J Sports Med 39(6):1217–1225PubMedCrossRef
31.
go back to reference Vaishnav S, Millett PJ (2010) Arthroscopic rotator cuff repair: scientific rationale, surgical technique, and early clinical and functional results of a knotless self-reinforcing double-row rotator cuff repair system. J Should Elbow Surg 19(2 Suppl):83–90CrossRef Vaishnav S, Millett PJ (2010) Arthroscopic rotator cuff repair: scientific rationale, surgical technique, and early clinical and functional results of a knotless self-reinforcing double-row rotator cuff repair system. J Should Elbow Surg 19(2 Suppl):83–90CrossRef
32.
go back to reference Voigt C, Bosse C, Vosshenrich R, Schulz AP, Lill H (2010) Arthroscopic supraspinatus tendon repair with suture-bridging technique: functional outcome and magnetic resonance imaging. Am J Sports Med 38(5):983–991PubMedCrossRef Voigt C, Bosse C, Vosshenrich R, Schulz AP, Lill H (2010) Arthroscopic supraspinatus tendon repair with suture-bridging technique: functional outcome and magnetic resonance imaging. Am J Sports Med 38(5):983–991PubMedCrossRef
Metadata
Title
Arthroscopic double-row cuff repair with suture-bridging: a structural and functional comparison of two techniques
Authors
P. Boyer
C. Bouthors
T. Delcourt
O. Stewart
F. Hamida
G. Mylle
P. Massin
Publication date
01-02-2015
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 2/2015
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-013-2401-7

Other articles of this Issue 2/2015

Knee Surgery, Sports Traumatology, Arthroscopy 2/2015 Go to the issue