Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 3/2013

01-03-2013 | Knee

Evaluation of sterilization methods following contamination of hamstring autograft during anterior cruciate ligament reconstruction

Authors: Matthew J. Plante, Xinning Li, Gail Scully, Michael A. Brown, Brian D. Busconi, Nicola A. DeAngelis

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 3/2013

Login to get access

Abstract

Purpose

Inadvertent contamination of the hamstring autograft during ACL reconstruction is infrequent, but can result in significant complications. The purpose of this study is to evaluate bacterial contamination of hamstring autografts dropped onto the operating room floor and methods of graft decontamination.

Methods

Hamstring tendons were harvested from patients. Excess tendon not used in the ACL procedure was divided into 6 segments. Segments were assigned to 6 groups (A through F, N = 30 in each group): group A: uncontaminated graft immediately postharvest (control), group B: graft dropped onto the floor (5 s), group C: graft dropped onto the floor (15 s). grafts in groups D to F were dropped onto floor for 15 s then rinsed with saline (group D), bacitracin solution (group E) or chlorhexidine 4 % solution (group F) for 3 min. All grafts were sent to the microbiology laboratory for anaerobic and aerobic cultures.

Results

Cultures were positive in 23 % of graft segments from group A (7/30), 33 % of grafts from group B (10/30), 23 % from group C (7/30), 30 % from group D (9/30) and 3 % from both group E (1/30) and group F (1/30). Sixteen unique organisms were identified, with Staphylococcus aureus as the most common isolate. Grafts rinsed in either bacitracin solution or 4 % chlorhexidine solutions were significantly less likely to be culture positive when compared to control graft segments (p < 0.05). However, there was no significant difference between uncontaminated grafts retrieved in <5 versus 15 s from the floor.

Conclusion

This study supports the practice of decontaminating a dropped ACL hamstring autograft using either 4 % chlorhexidine or bacitracin solution. Specimens should be retrieved sterilely and washed for at least 3 min. This study also demonstrates no advantage in retrieval time of less than 5 s as compared to 15 s for uncontaminated graft. Hamstring harvest in ACL reconstruction may result in positive cultures, thus routine soaking of the hamstring autograft in either bacitracin or 4 % chlorhexidine solution is recommended. In addition, dropped hamstring autograft can be effectively sterilized with bacitracin or 4 % chlorhexidine solution.

Level of evidence

II.
Literature
1.
go back to reference Boni DM, Herriott GE (2002) Hamstring tendon graft for anterior cruciate ligament reconstruction. AORN J 76(4):610–615, 7–9, 21–24; quiz 25–28 Boni DM, Herriott GE (2002) Hamstring tendon graft for anterior cruciate ligament reconstruction. AORN J 76(4):610–615, 7–9, 21–24; quiz 25–28
2.
go back to reference Burd T, Conroy BP, Meyer SC et al (2000) The effects of chlorhexidine irrigation solution on contaminated bone-tendon allografts. Am J Sports Med 28(2):241–244PubMed Burd T, Conroy BP, Meyer SC et al (2000) The effects of chlorhexidine irrigation solution on contaminated bone-tendon allografts. Am J Sports Med 28(2):241–244PubMed
3.
go back to reference Casalonga D, Ait Si Selmi T, Robinson A et al (1999) Peroperative accidental contamination of bone-tendon-bone graft for the reconstruction of the anterior cruciate ligament. Report of 4 cases. Rev Chir Orthop Reparatrice Appar Mot 85(7):740–743PubMed Casalonga D, Ait Si Selmi T, Robinson A et al (1999) Peroperative accidental contamination of bone-tendon-bone graft for the reconstruction of the anterior cruciate ligament. Report of 4 cases. Rev Chir Orthop Reparatrice Appar Mot 85(7):740–743PubMed
4.
go back to reference Centeno RF, Desai AR, Watson ME (2008) Management of contaminated autologous grafts in plastic surgery. Eplasty 8:e23PubMed Centeno RF, Desai AR, Watson ME (2008) Management of contaminated autologous grafts in plastic surgery. Eplasty 8:e23PubMed
5.
go back to reference Cooper DE, Arnoczky SP, Warren RF (1991) Contaminated patellar tendon grafts: incidence of positive cultures and efficacy of an antibiotic solution soak—an in vitro study. Arthroscopy 7(3):272–274PubMedCrossRef Cooper DE, Arnoczky SP, Warren RF (1991) Contaminated patellar tendon grafts: incidence of positive cultures and efficacy of an antibiotic solution soak—an in vitro study. Arthroscopy 7(3):272–274PubMedCrossRef
6.
go back to reference Diaz-de-Rada P, Barriga A, Barroso JL et al (2003) Positive culture in allograft ACL-reconstruction: what to do? Knee Surg Sports Traumatol Arthrosc 11(4):219–222PubMedCrossRef Diaz-de-Rada P, Barriga A, Barroso JL et al (2003) Positive culture in allograft ACL-reconstruction: what to do? Knee Surg Sports Traumatol Arthrosc 11(4):219–222PubMedCrossRef
7.
go back to reference Freedman KB, D’Amato MJ, Nedeff DD et al (2003) Arthroscopic anterior cruciate ligament reconstruction: a metaanalysis comparing patellar tendon and hamstring tendon autografts. Am J Sports Med 31(1):2–11PubMed Freedman KB, D’Amato MJ, Nedeff DD et al (2003) Arthroscopic anterior cruciate ligament reconstruction: a metaanalysis comparing patellar tendon and hamstring tendon autografts. Am J Sports Med 31(1):2–11PubMed
8.
go back to reference Gavriilidis I, Pakos EE, Wipfler B et al (2009) Intra-operative hamstring tendon graft contamination in anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 17(9):1043–1047PubMedCrossRef Gavriilidis I, Pakos EE, Wipfler B et al (2009) Intra-operative hamstring tendon graft contamination in anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 17(9):1043–1047PubMedCrossRef
9.
go back to reference Guelich DR, Lowe WR, Wilson B (2007) The routine culture of allograft tissue in anterior cruciate ligament reconstruction. Am J Sports Med 35(9):1495–1499PubMedCrossRef Guelich DR, Lowe WR, Wilson B (2007) The routine culture of allograft tissue in anterior cruciate ligament reconstruction. Am J Sports Med 35(9):1495–1499PubMedCrossRef
10.
go back to reference Hantes ME, Basdekis GK, Varitimidis SE et al (2008) Autograft contamination during preparation for anterior cruciate ligament reconstruction. J Bone Joint Surg Am 90(4):760–764PubMedCrossRef Hantes ME, Basdekis GK, Varitimidis SE et al (2008) Autograft contamination during preparation for anterior cruciate ligament reconstruction. J Bone Joint Surg Am 90(4):760–764PubMedCrossRef
11.
go back to reference Izquierdo R Jr, Cadet ER, Bauer R et al (2005) A survey of sports medicine specialists investigating the preferred management of contaminated anterior cruciate ligament grafts. Arthroscopy 21(11):1348–1353PubMedCrossRef Izquierdo R Jr, Cadet ER, Bauer R et al (2005) A survey of sports medicine specialists investigating the preferred management of contaminated anterior cruciate ligament grafts. Arthroscopy 21(11):1348–1353PubMedCrossRef
12.
go back to reference Marrale J, Morrissey MC, Haddad FS (2007) A literature review of autograft and allograft anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 15(6):690–704PubMedCrossRef Marrale J, Morrissey MC, Haddad FS (2007) A literature review of autograft and allograft anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 15(6):690–704PubMedCrossRef
13.
go back to reference Molina ME, Nonweiller DE, Evans JA et al (2000) Contaminated anterior cruciate ligament grafts: the efficacy of 3 sterilization agents. Arthroscopy 16(4):373–378PubMedCrossRef Molina ME, Nonweiller DE, Evans JA et al (2000) Contaminated anterior cruciate ligament grafts: the efficacy of 3 sterilization agents. Arthroscopy 16(4):373–378PubMedCrossRef
14.
go back to reference Nagda SH, Altobelli GG, Bowdry KA et al (2009) Cost analysis of outpatient anterior cruciate ligament reconstruction: autograft versus allograft. Clin Orthop Relat Res 468:1418–1422PubMedCrossRef Nagda SH, Altobelli GG, Bowdry KA et al (2009) Cost analysis of outpatient anterior cruciate ligament reconstruction: autograft versus allograft. Clin Orthop Relat Res 468:1418–1422PubMedCrossRef
15.
go back to reference Parker RD, Maschke SD (2008) Mechanical agitation and serial dilution: anoption for anterior cruciate ligament sterilzation. J Knee Surg 21(3):186–191PubMedCrossRef Parker RD, Maschke SD (2008) Mechanical agitation and serial dilution: anoption for anterior cruciate ligament sterilzation. J Knee Surg 21(3):186–191PubMedCrossRef
16.
go back to reference Pasque CB, Geib TM (2007) Intraoperative anterior cruciate ligament graft contamination. Arthroscopy 23(3):329–331PubMedCrossRef Pasque CB, Geib TM (2007) Intraoperative anterior cruciate ligament graft contamination. Arthroscopy 23(3):329–331PubMedCrossRef
17.
go back to reference Saegeman VS, Ectors NL, Lismont D et al (2009) Effectiveness of antibiotics and antiseptics on coagulase-negative staphylococci for the decontamination of bone allografts. Eur J Clin Microbiol Infect Dis 28(7):813–816PubMedCrossRef Saegeman VS, Ectors NL, Lismont D et al (2009) Effectiveness of antibiotics and antiseptics on coagulase-negative staphylococci for the decontamination of bone allografts. Eur J Clin Microbiol Infect Dis 28(7):813–816PubMedCrossRef
18.
go back to reference Shelton WR, Fagan BC (2011) Autografts commonly used in anterior cruciate ligament reconstruction. J Am Acad Orthop Surg 19(5):259–264PubMed Shelton WR, Fagan BC (2011) Autografts commonly used in anterior cruciate ligament reconstruction. J Am Acad Orthop Surg 19(5):259–264PubMed
19.
go back to reference Tuman J, Diduch DR, Baumfeld JA et al (2008) Joint infection unique to hamstring tendon harvester used during anterior cruciate ligament reconstruction surgery. Arthroscopy 24(5):618–620PubMedCrossRef Tuman J, Diduch DR, Baumfeld JA et al (2008) Joint infection unique to hamstring tendon harvester used during anterior cruciate ligament reconstruction surgery. Arthroscopy 24(5):618–620PubMedCrossRef
Metadata
Title
Evaluation of sterilization methods following contamination of hamstring autograft during anterior cruciate ligament reconstruction
Authors
Matthew J. Plante
Xinning Li
Gail Scully
Michael A. Brown
Brian D. Busconi
Nicola A. DeAngelis
Publication date
01-03-2013
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 3/2013
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-012-2049-8

Other articles of this Issue 3/2013

Knee Surgery, Sports Traumatology, Arthroscopy 3/2013 Go to the issue