Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 6/2012

01-06-2012 | Shoulder

Arthroscopic transosseous (anchorless) rotator cuff repair

Authors: Raffaele Garofalo, Alessandro Castagna, Mario Borroni, Sumant G. Krishnan

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 6/2012

Login to get access

Abstract

The traditional open transosseous rotator cuff repair gives excellent results for the fixation of tendon to bone and has represented the gold standard for rotator cuff surgery with excellent long-term results. In the last few years, different arthroscopic techniques using suture anchors have been developed to increase the tendon–bone contact area in an attempt to reconstitute a more anatomic configuration of the rotator cuff footprint while providing a better environment for tendon healing. However, the anchor-based techniques have still not replicated the traditional open transosseous repair. A surgical technique that allows surgeons to perform a standardized arthroscopic transosseous (anchor free) repair of rotator cuff tears using a new disposable device is described. With this system, it is possible to perform a transosseous technique in a reproducible fashion. This novel technique combines the clinical advantages of minimally invasive arthroscopic surgery and the biomechanical advantages of open transosseous procedures. Level of evidence V.
Literature
1.
go back to reference Apreleva M, Ozbaydar M, Fitzgibbons PG, Warner JJ (2002) Rotator cuff tears: the effect of the reconstruction method on three-dimensional repair site area. Arthroscopy 18(5):519–526PubMedCrossRef Apreleva M, Ozbaydar M, Fitzgibbons PG, Warner JJ (2002) Rotator cuff tears: the effect of the reconstruction method on three-dimensional repair site area. Arthroscopy 18(5):519–526PubMedCrossRef
2.
go back to reference Benson EC, MacDermid JC, Drosdowech DS, Athwal GS (2010) The incidence of early metallic suture anchor pull-out after arthroscopic rotator cuff repair. Arthroscopy 26(3):310–315PubMedCrossRef Benson EC, MacDermid JC, Drosdowech DS, Athwal GS (2010) The incidence of early metallic suture anchor pull-out after arthroscopic rotator cuff repair. Arthroscopy 26(3):310–315PubMedCrossRef
3.
go back to reference Boileau P, Brassart N, Watkinson DJ, Charles M, Hatzidakis AM, Krishnan SG (2005) Arthroscopic repair of full-thikness tears of the supraspinatus: does the tendon really heal? J Bone Joint Surg Am 87(6):1229–1240PubMedCrossRef Boileau P, Brassart N, Watkinson DJ, Charles M, Hatzidakis AM, Krishnan SG (2005) Arthroscopic repair of full-thikness tears of the supraspinatus: does the tendon really heal? J Bone Joint Surg Am 87(6):1229–1240PubMedCrossRef
4.
go back to reference Caldwell GL, Warner JP, Miller MD, Boardman D, Towers J, Debski R (1997) Strength of fixation with transosseous sutures in rotator cuff repair. J Bone Joint Surg Am 79(7):1064–1068PubMed Caldwell GL, Warner JP, Miller MD, Boardman D, Towers J, Debski R (1997) Strength of fixation with transosseous sutures in rotator cuff repair. J Bone Joint Surg Am 79(7):1064–1068PubMed
5.
go back to reference Charousset C, Grimberg J, Duranthon LD, Bellaiche L, Petrover D (2007) Can a double-row anchorage technique improve tendon healing in arthroscopic rotator cuff repair? A prospective, nonrandomized, comparative study of double row anchorage techniques with computed tomographic arthrography tendon healing assessment. Am J Sports Med 35(8):1247–1253PubMedCrossRef Charousset C, Grimberg J, Duranthon LD, Bellaiche L, Petrover D (2007) Can a double-row anchorage technique improve tendon healing in arthroscopic rotator cuff repair? A prospective, nonrandomized, comparative study of double row anchorage techniques with computed tomographic arthrography tendon healing assessment. Am J Sports Med 35(8):1247–1253PubMedCrossRef
6.
go back to reference Cho NS, Yi JW, Lee BG, Rhee YG (2010) Retear patterns after arthroscopic rotator cuff repair: single row versus suture bridge technique. Am J Sports Med 38(4):664–671PubMedCrossRef Cho NS, Yi JW, Lee BG, Rhee YG (2010) Retear patterns after arthroscopic rotator cuff repair: single row versus suture bridge technique. Am J Sports Med 38(4):664–671PubMedCrossRef
7.
go back to reference Fleega BA (2002) Arthroscopic transhumeral rotator cuff repair: giant needle technique. Arthroscopy 18(2):218–223PubMedCrossRef Fleega BA (2002) Arthroscopic transhumeral rotator cuff repair: giant needle technique. Arthroscopy 18(2):218–223PubMedCrossRef
8.
go back to reference Fox MP, Auffarth A, Tauber M, Hartmann A, Resch H (2008) A novel transosseous button technique for rotator cuff repair. Arthroscopy 24(9):1074–1077PubMedCrossRef Fox MP, Auffarth A, Tauber M, Hartmann A, Resch H (2008) A novel transosseous button technique for rotator cuff repair. Arthroscopy 24(9):1074–1077PubMedCrossRef
9.
go back to reference Franceschi F, Ruzzini L, Longo UG et al (2007) Equivalent clinical results of arthroscopic single row and double row suture anchor repair for rotator cuff tears: a randomized controlled trial. Am J Sports Med 35(8):1254–1260PubMedCrossRef Franceschi F, Ruzzini L, Longo UG et al (2007) Equivalent clinical results of arthroscopic single row and double row suture anchor repair for rotator cuff tears: a randomized controlled trial. Am J Sports Med 35(8):1254–1260PubMedCrossRef
10.
go back to reference Frank JB, ElAttrache NS, Dines JS, Blackburn A, Crues J, Tibone JE (2008) Repair site integrity after arthroscopic transosseous-equivalent suture-bridge rotator cuff repair. Am J Sports Med 36(8):1496–1503PubMedCrossRef Frank JB, ElAttrache NS, Dines JS, Blackburn A, Crues J, Tibone JE (2008) Repair site integrity after arthroscopic transosseous-equivalent suture-bridge rotator cuff repair. Am J Sports Med 36(8):1496–1503PubMedCrossRef
11.
go back to reference Frick H, Haag M, Volz M, Stehle J (2010) Arthroscopic bone needle: a new, safe, and cost-effective technique for rotator cuff repair. Tech Should Surg 11:107–112CrossRef Frick H, Haag M, Volz M, Stehle J (2010) Arthroscopic bone needle: a new, safe, and cost-effective technique for rotator cuff repair. Tech Should Surg 11:107–112CrossRef
12.
go back to reference Galatz LM, Griggs S, Cameron BD, Iannotti JP (2001) Prospective longitudinal analysis of postoperative shoulder function: a ten year follow-up study of full-thickness rotator cuff tears. J Bone Joint Surg Am 83-A(7):1052–1056PubMed Galatz LM, Griggs S, Cameron BD, Iannotti JP (2001) Prospective longitudinal analysis of postoperative shoulder function: a ten year follow-up study of full-thickness rotator cuff tears. J Bone Joint Surg Am 83-A(7):1052–1056PubMed
13.
go back to reference Galatz LM, Ball CM, Teefey SA, Middleton WD, Yamaguchi K (2004) The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. J Bone Joint Surg Am 86A(2):219–224 Galatz LM, Ball CM, Teefey SA, Middleton WD, Yamaguchi K (2004) The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. J Bone Joint Surg Am 86A(2):219–224
14.
go back to reference Jost B, Pfirmann CW, Gerber C, Switzerland Z (2000) Clinical outcome after structural failure of the rotator cuff repairs. J Bone Joint Surg Am 82(3):304–314PubMed Jost B, Pfirmann CW, Gerber C, Switzerland Z (2000) Clinical outcome after structural failure of the rotator cuff repairs. J Bone Joint Surg Am 82(3):304–314PubMed
15.
go back to reference Kim KC, Rhee KJ, Shin HD, Kim YM (2008) Arthroscopic transosseous rotator cuff repair. Orthopedics 31(4):327–330PubMedCrossRef Kim KC, Rhee KJ, Shin HD, Kim YM (2008) Arthroscopic transosseous rotator cuff repair. Orthopedics 31(4):327–330PubMedCrossRef
16.
go back to reference Lo IK, Burkhart SS (2003) Double row arthroscopic rotator cuff repair: re-establishing the footprint of the rotator cuff. Arthroscopy 19(9):1035–1042PubMedCrossRef Lo IK, Burkhart SS (2003) Double row arthroscopic rotator cuff repair: re-establishing the footprint of the rotator cuff. Arthroscopy 19(9):1035–1042PubMedCrossRef
17.
go back to reference Park MC, Cadet ER, Levine WN, Bigliani LU, Ahmad CS (2005) Tendon-to-bone pressure distributions at a repaired rotator cuff footprint using transosseous suture and suture anchor fixation techniques. Am J Sports Med Aug 33(8):1154–1159CrossRef Park MC, Cadet ER, Levine WN, Bigliani LU, Ahmad CS (2005) Tendon-to-bone pressure distributions at a repaired rotator cuff footprint using transosseous suture and suture anchor fixation techniques. Am J Sports Med Aug 33(8):1154–1159CrossRef
18.
go back to reference Park MC, ElAttrache NS, Tibone JE, Ahmad CS, Jun BJ, Lee TQ (2007) Part I: footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elbow Surg 16(4):461–468PubMedCrossRef Park MC, ElAttrache NS, Tibone JE, Ahmad CS, Jun BJ, Lee TQ (2007) Part I: footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elbow Surg 16(4):461–468PubMedCrossRef
19.
go back to reference Pennington WT, Gibbons DJ, Bartz BA et al (2010) Comparative analysis of single row versus double row repair of rotator tears. Arthroscopy 26(11):1419–1426PubMedCrossRef Pennington WT, Gibbons DJ, Bartz BA et al (2010) Comparative analysis of single row versus double row repair of rotator tears. Arthroscopy 26(11):1419–1426PubMedCrossRef
20.
go back to reference Post M, Silver R, Singh M (1983) Rotator cuff tear. Diagnosis and treatment. Clin Orthop Relat Res 173:78–91PubMed Post M, Silver R, Singh M (1983) Rotator cuff tear. Diagnosis and treatment. Clin Orthop Relat Res 173:78–91PubMed
21.
go back to reference Ramsey ML, Getz CL, Parsons BO (2009) What’s new in shoulder and elbow surgery. J Bone Joint Surg Am 92(4):1047–1061CrossRef Ramsey ML, Getz CL, Parsons BO (2009) What’s new in shoulder and elbow surgery. J Bone Joint Surg Am 92(4):1047–1061CrossRef
22.
go back to reference Rossouw DJ, McElroy BJ, Amis AA, Emery RJ (1997) A Biomechanical evaluation of suture anchors in repair of the rotator cuff. J Bone Joint Surg Br 79(3):458–461PubMedCrossRef Rossouw DJ, McElroy BJ, Amis AA, Emery RJ (1997) A Biomechanical evaluation of suture anchors in repair of the rotator cuff. J Bone Joint Surg Br 79(3):458–461PubMedCrossRef
23.
go back to reference Shea KP, Jennings JE (1998) Arthroscopic rotator cuff repair using a transhumeral approach to fixation. Arthroscopy 14(1):118–122PubMedCrossRef Shea KP, Jennings JE (1998) Arthroscopic rotator cuff repair using a transhumeral approach to fixation. Arthroscopy 14(1):118–122PubMedCrossRef
24.
go back to reference Sugaya H, Maeda K, Matsuki K, Mooriishi J (2005) Functional and structural outcome after arhroscopic full thickness rotator cuff repair: single row versus dual row fixation. Arthroscopy 21(11):1307–1316PubMedCrossRef Sugaya H, Maeda K, Matsuki K, Mooriishi J (2005) Functional and structural outcome after arhroscopic full thickness rotator cuff repair: single row versus dual row fixation. Arthroscopy 21(11):1307–1316PubMedCrossRef
25.
go back to reference Tashjian RZ, Hollins AM, Kim HM et al (2010) Factors affecting healing rates after arthroscopic double row rotator cuff repair. Am J Sports Med 38(12):2435–2442PubMedCrossRef Tashjian RZ, Hollins AM, Kim HM et al (2010) Factors affecting healing rates after arthroscopic double row rotator cuff repair. Am J Sports Med 38(12):2435–2442PubMedCrossRef
26.
go back to reference Tauber M, Koller H, Resch H (2008) Transosseous arthroscopic repair of partial articular-surface supraspinatus tendon tears. Knee Surg Sports Traumatol Arthrosc 16(6):608–613PubMedCrossRef Tauber M, Koller H, Resch H (2008) Transosseous arthroscopic repair of partial articular-surface supraspinatus tendon tears. Knee Surg Sports Traumatol Arthrosc 16(6):608–613PubMedCrossRef
27.
go back to reference Zumstein MA, Jost B, Hempel J, Hodler J, Gerber C (2008) The clinical and structural long-term results of open repair of massive tears of the rotator cuff. J Bone Joint Surg A 90(11):2423–2431CrossRef Zumstein MA, Jost B, Hempel J, Hodler J, Gerber C (2008) The clinical and structural long-term results of open repair of massive tears of the rotator cuff. J Bone Joint Surg A 90(11):2423–2431CrossRef
Metadata
Title
Arthroscopic transosseous (anchorless) rotator cuff repair
Authors
Raffaele Garofalo
Alessandro Castagna
Mario Borroni
Sumant G. Krishnan
Publication date
01-06-2012
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 6/2012
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-011-1725-4

Other articles of this Issue 6/2012

Knee Surgery, Sports Traumatology, Arthroscopy 6/2012 Go to the issue