Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 6/2012

01-06-2012 | Knee

In vivo sagittal plane kinematics of the FPV patellofemoral replacement

Authors: A. P. Monk, B. H. van Duren, H. Pandit, D. Shakespeare, D. W. Murray, H. S. Gill

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 6/2012

Login to get access

Abstract

Purpose

Isolated symptomatic patellofemoral osteoarthritis has been reported in 2% of men and 8% of women older than the age of 55 years in the community. With the development of improved designs and surgical techniques, interest in the use of patellofemoral replacement has increased. The primary aim of the newer generation of patellofemoral replacement implant designs has been to more closely reproduce normal knee kinematics. This study compares the functional sagittal plane in vivo kinematics of a contemporary patellofemoral prosthesis, the FPV, with normal knee kinematics using the patella tendon angle and patella flexion angle relationships with the knee flexion angle.

Methods

The in vivo kinematics for a group of 8 patients (15 knees) with patellofemoral replacement and 22 normal subjects was measured for both a step-up and a lunge exercise using an established fluoroscopic method.

Results

The patella tendon angle characteristics of the implanted knees were similar to those of the normal knees for the step-up exercise with a significant difference only observed at 50° knee flexion angle. For the lunge exercise, the patella tendon angle for the implanted knee was consistently lower than that measured for the normal knee. Overall the subjects had excellent clinical scores post-patellofemoral replacement showing a significant improvement from their pre-operative scores.

Conclusion

The kinematics of the FPV implant was closer to normal than those of total knee implants; however, there were still differences from the normal knees.

Level of evidence

III.
Literature
1.
go back to reference Ackroyd CE, Chir B (2005) Development and early results of a new patellofemoral arthroplasty. Clin Orthop Relat Res 436:7–13PubMedCrossRef Ackroyd CE, Chir B (2005) Development and early results of a new patellofemoral arthroplasty. Clin Orthop Relat Res 436:7–13PubMedCrossRef
2.
go back to reference Ackroyd CE, Newman JH, Evans R, Eldridge JD, Joslin CC (2007) The Avon patellofemoral arthroplasty: five-year survivorship and functional results. J Bone Joint Surg Br 89(3):310–315PubMedCrossRef Ackroyd CE, Newman JH, Evans R, Eldridge JD, Joslin CC (2007) The Avon patellofemoral arthroplasty: five-year survivorship and functional results. J Bone Joint Surg Br 89(3):310–315PubMedCrossRef
3.
go back to reference Ackroyd CE, Polyzoides AJ (1978) Patellectomy for osteoarthritis. A study of eighty-one patients followed from two to twenty-two years. J Bone Joint Surg Br 60-B(3):353–357PubMed Ackroyd CE, Polyzoides AJ (1978) Patellectomy for osteoarthritis. A study of eighty-one patients followed from two to twenty-two years. J Bone Joint Surg Br 60-B(3):353–357PubMed
4.
go back to reference Baltzopoulos V (1995) A videofluoroscopy method for optical distortion correction and measurement of knee-joint kinematics. Clin Biomech (Bristol, Avon) 10(2):85–92CrossRef Baltzopoulos V (1995) A videofluoroscopy method for optical distortion correction and measurement of knee-joint kinematics. Clin Biomech (Bristol, Avon) 10(2):85–92CrossRef
5.
go back to reference Banks SA, Harman MK, Bellemans J, Hodge WA (2003) Making sense of knee arthroplasty kinematics: news you can use. J Bone Joint Surg Am 85-A(Suppl 4):64–72PubMed Banks SA, Harman MK, Bellemans J, Hodge WA (2003) Making sense of knee arthroplasty kinematics: news you can use. J Bone Joint Surg Am 85-A(Suppl 4):64–72PubMed
6.
go back to reference Banks SA, Hodge WA (1996) Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans Biomed Eng 43(6):638–649PubMedCrossRef Banks SA, Hodge WA (1996) Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans Biomed Eng 43(6):638–649PubMedCrossRef
7.
go back to reference Becher C, Renke A, Heyse TJ, Schofer M, Tibesku CO, Fuchs-Winkelmann S (2008) Patellofemoral arthroplasty–results of a nation-wide survey in Germany and review of the literature. Z Orthop Unfall 146(6):773–781PubMedCrossRef Becher C, Renke A, Heyse TJ, Schofer M, Tibesku CO, Fuchs-Winkelmann S (2008) Patellofemoral arthroplasty–results of a nation-wide survey in Germany and review of the literature. Z Orthop Unfall 146(6):773–781PubMedCrossRef
8.
go back to reference Blazina ME, Fox JM, Del Pizzo W, Broukhim B, Ivey FM (1979) Patellofemoral replacement. Clin Orthop Relat Res 144:98–102PubMed Blazina ME, Fox JM, Del Pizzo W, Broukhim B, Ivey FM (1979) Patellofemoral replacement. Clin Orthop Relat Res 144:98–102PubMed
9.
go back to reference Charalambous CP, Abiddin Z, Mills SP, Rogers S, Sutton P, Parkinson R (2011) The low contact stress patellofemoral replacement: high early failure rate. J Bone Joint Surg Br 93(4):484–489PubMedCrossRef Charalambous CP, Abiddin Z, Mills SP, Rogers S, Sutton P, Parkinson R (2011) The low contact stress patellofemoral replacement: high early failure rate. J Bone Joint Surg Br 93(4):484–489PubMedCrossRef
10.
go back to reference Dawson J, Fitzpatrick R, Murray D, Carr A (1998) Questionnaire on the perceptions of patients about total knee replacement. J Bone Joint Surg Br 80(1):63–69PubMedCrossRef Dawson J, Fitzpatrick R, Murray D, Carr A (1998) Questionnaire on the perceptions of patients about total knee replacement. J Bone Joint Surg Br 80(1):63–69PubMedCrossRef
11.
go back to reference Fantozzi S, Catani F, Ensini A, Leardini A, Giannini S (2006) Femoral rollback of cruciate-retaining and posterior-stabilized total knee replacements: in vivo fluoroscopic analysis during activities of daily living. J Orthop Res 24(12):2222–2229PubMedCrossRef Fantozzi S, Catani F, Ensini A, Leardini A, Giannini S (2006) Femoral rollback of cruciate-retaining and posterior-stabilized total knee replacements: in vivo fluoroscopic analysis during activities of daily living. J Orthop Res 24(12):2222–2229PubMedCrossRef
12.
go back to reference Ficat RP, Ficat C, Gedeon P, Toussaint JB (1979) Spongialization: a new treatment for diseased patellae. Clin Orthop Relat Res 144:74–83PubMed Ficat RP, Ficat C, Gedeon P, Toussaint JB (1979) Spongialization: a new treatment for diseased patellae. Clin Orthop Relat Res 144:74–83PubMed
13.
go back to reference Gill HS, O’Connor JJ (1996) Biarticulating two-dimensional computer model of the human patellofemoral joint. Clin Biomech (Bristol, Avon) 11(2):81–89CrossRef Gill HS, O’Connor JJ (1996) Biarticulating two-dimensional computer model of the human patellofemoral joint. Clin Biomech (Bristol, Avon) 11(2):81–89CrossRef
14.
go back to reference Hollinghurst D, Stoney J, Ward T, Pandit H, Beard D, Murray DW (2007) In vivo sagittal plane kinematics of the Avon patellofemoral arthroplasty. J Arthroplasty 22(1):117–123PubMedCrossRef Hollinghurst D, Stoney J, Ward T, Pandit H, Beard D, Murray DW (2007) In vivo sagittal plane kinematics of the Avon patellofemoral arthroplasty. J Arthroplasty 22(1):117–123PubMedCrossRef
15.
go back to reference Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed
16.
go back to reference Kooijman HJ, Driessen AP, van Horn JR (2003) Long-term results of patellofemoral arthroplasty. A report of 56 arthroplasties with 17 years of follow-up. J Bone Joint Surg Br 85(6):836–840PubMed Kooijman HJ, Driessen AP, van Horn JR (2003) Long-term results of patellofemoral arthroplasty. A report of 56 arthroplasties with 17 years of follow-up. J Bone Joint Surg Br 85(6):836–840PubMed
17.
go back to reference Leadbetter WB, Ragland PS, Mont MA (2005) The appropriate use of patellofemoral arthroplasty: an analysis of reported indications, contraindications, and failures. Clin Orthop Relat Res 436:91–99PubMedCrossRef Leadbetter WB, Ragland PS, Mont MA (2005) The appropriate use of patellofemoral arthroplasty: an analysis of reported indications, contraindications, and failures. Clin Orthop Relat Res 436:91–99PubMedCrossRef
18.
19.
go back to reference Maquet P (1976) Advancement of the tibial tuberosity. Clin Orthop Relat Res 115:225–230PubMed Maquet P (1976) Advancement of the tibial tuberosity. Clin Orthop Relat Res 115:225–230PubMed
20.
go back to reference McKeever DC (1955) Patellar prosthesis. J Bone Joint Surg Am 37-A(5):1074–1084PubMed McKeever DC (1955) Patellar prosthesis. J Bone Joint Surg Am 37-A(5):1074–1084PubMed
21.
go back to reference Miller RK, Goodfellow JW, Murray DW, O’Connor JJ (1998) In vitro measurement of patellofemoral force after three types of knee replacement. J Bone Joint Surg Br 80(5):900–906PubMedCrossRef Miller RK, Goodfellow JW, Murray DW, O’Connor JJ (1998) In vitro measurement of patellofemoral force after three types of knee replacement. J Bone Joint Surg Br 80(5):900–906PubMedCrossRef
22.
go back to reference Pandit H, van Duren BH, Gallagher JA, Beard DJ, Dodd CA, Gill HS, Murray DW (2008) Combined anterior cruciate reconstruction and Oxford unicompartmental knee arthroplasty: in vivo kinematics. Knee 15(2):101–106PubMedCrossRef Pandit H, van Duren BH, Gallagher JA, Beard DJ, Dodd CA, Gill HS, Murray DW (2008) Combined anterior cruciate reconstruction and Oxford unicompartmental knee arthroplasty: in vivo kinematics. Knee 15(2):101–106PubMedCrossRef
23.
go back to reference Pandit H, Ward T, Hollinghurst D, Beard DJ, Gill HS, Thomas NP, Murray DW (2005) Influence of surface geometry and the cam-post mechanism on the kinematics of total knee replacement. J Bone Joint Surg Br 87(7):940–945PubMedCrossRef Pandit H, Ward T, Hollinghurst D, Beard DJ, Gill HS, Thomas NP, Murray DW (2005) Influence of surface geometry and the cam-post mechanism on the kinematics of total knee replacement. J Bone Joint Surg Br 87(7):940–945PubMedCrossRef
24.
go back to reference Price AJ, Oppold PT, Murray DW, Zavatsky AB (2006) Simultaneous in vitro measurement of patellofemoral kinematics and forces following Oxford medial unicompartmental knee replacement. J Bone Joint Surg Br 88(12):1591–1595PubMedCrossRef Price AJ, Oppold PT, Murray DW, Zavatsky AB (2006) Simultaneous in vitro measurement of patellofemoral kinematics and forces following Oxford medial unicompartmental knee replacement. J Bone Joint Surg Br 88(12):1591–1595PubMedCrossRef
25.
go back to reference Price AJ, Rees JL, Beard DJ, Gill RH, Dodd CA, Murray DM (2004) Sagittal plane kinematics of a mobile-bearing unicompartmental knee arthroplasty at 10 years: a comparative in vivo fluoroscopic analysis. J Arthroplasty 19(5):590–597PubMedCrossRef Price AJ, Rees JL, Beard DJ, Gill RH, Dodd CA, Murray DM (2004) Sagittal plane kinematics of a mobile-bearing unicompartmental knee arthroplasty at 10 years: a comparative in vivo fluoroscopic analysis. J Arthroplasty 19(5):590–597PubMedCrossRef
26.
go back to reference Rees JL, Price AJ, Beard DJ, Robinson BJ, Murray DW (2002) Defining the femoral axis on lateral knee fluoroscopy. Knee 9(1):65–68PubMedCrossRef Rees JL, Price AJ, Beard DJ, Robinson BJ, Murray DW (2002) Defining the femoral axis on lateral knee fluoroscopy. Knee 9(1):65–68PubMedCrossRef
27.
go back to reference Stagni R, Fantozzi S, Catani F, Leardini A (2010) Can Patellar Tendon Angle reveal sagittal kinematics in total knee arthroplasty? Knee Surg Sports Traumatol Arthrosc 18(7):949–954PubMedCrossRef Stagni R, Fantozzi S, Catani F, Leardini A (2010) Can Patellar Tendon Angle reveal sagittal kinematics in total knee arthroplasty? Knee Surg Sports Traumatol Arthrosc 18(7):949–954PubMedCrossRef
28.
go back to reference Tibesku CO, Daniilidis K, Vieth V, Skwara A, Heindel W, Fuchs-Winkelmann S (2011) Sagittal plane kinematics of fixed- and mobile-bearing total knee replacements. Knee Surg Sports Traumatol Arthrosc 19(9):1488–1495. doi:10.1007/s00167-011-1462-8 PubMedCrossRef Tibesku CO, Daniilidis K, Vieth V, Skwara A, Heindel W, Fuchs-Winkelmann S (2011) Sagittal plane kinematics of fixed- and mobile-bearing total knee replacements. Knee Surg Sports Traumatol Arthrosc 19(9):1488–1495. doi:10.​1007/​s00167-011-1462-8 PubMedCrossRef
29.
go back to reference van Duren BH, Pandit H, Beard DJ, Murray DW, Gill HS (2009) Accuracy evaluation of fluoroscopy-based 2D and 3D pose reconstruction with unicompartmental knee arthroplasty. Med Eng Phys 31(3):356–363PubMedCrossRef van Duren BH, Pandit H, Beard DJ, Murray DW, Gill HS (2009) Accuracy evaluation of fluoroscopy-based 2D and 3D pose reconstruction with unicompartmental knee arthroplasty. Med Eng Phys 31(3):356–363PubMedCrossRef
30.
go back to reference van Duren BH, Pandit H, Beard DJ, Zavatsky AB, Gallagher JA, Thomas NP, Shakespeare DT, Murray DW, Gill HS (2007) How effective are added constraints in improving TKR kinematics? J Biomech 40(Suppl 1):S31–37 van Duren BH, Pandit H, Beard DJ, Zavatsky AB, Gallagher JA, Thomas NP, Shakespeare DT, Murray DW, Gill HS (2007) How effective are added constraints in improving TKR kinematics? J Biomech 40(Suppl 1):S31–37
31.
go back to reference van Jonbergen HP, Poolman RW, van Kampen A (2010) Isolated patellofemoral osteoarthritis. Acta Orthop 81(2):199–205PubMedCrossRef van Jonbergen HP, Poolman RW, van Kampen A (2010) Isolated patellofemoral osteoarthritis. Acta Orthop 81(2):199–205PubMedCrossRef
32.
go back to reference van Wagenberg JM, Speigner B, Gosens T, de Waal Malefijt J (2009) Midterm clinical results of the Autocentric II patellofemoral prosthesis. Int Orthop 33(6):1603–1608PubMedCrossRef van Wagenberg JM, Speigner B, Gosens T, de Waal Malefijt J (2009) Midterm clinical results of the Autocentric II patellofemoral prosthesis. Int Orthop 33(6):1603–1608PubMedCrossRef
Metadata
Title
In vivo sagittal plane kinematics of the FPV patellofemoral replacement
Authors
A. P. Monk
B. H. van Duren
H. Pandit
D. Shakespeare
D. W. Murray
H. S. Gill
Publication date
01-06-2012
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 6/2012
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-011-1717-4

Other articles of this Issue 6/2012

Knee Surgery, Sports Traumatology, Arthroscopy 6/2012 Go to the issue