Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 12/2011

01-12-2011 | Knee

Comparison of joint line position changes after primary bilateral total knee arthroplasty performed using the navigation-assisted measured gap resection or gap balancing techniques

Authors: Han Jun Lee, Jae Sung Lee, Ho Joong Jung, Kwang Sup Song, Jae Jun Yang, Chi Woo Park

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 12/2011

Login to get access

Abstract

Purpose

This study aimed to compare the clinical and radiological results of navigation-assisted TKAs performed using the measured gap resection or the gap balancing technique in thirty patients who underwent bilateral primary TKAs.

Methods

Sixty cases of navigation-assisted TKAs [30 TKAs performed using the measured gap resection technique (Group A) and 30 TKAs performed using the gap balancing technique (Group B)] were analyzed prospectively with minimum follow-up of 2 years. The joint line positions were measured using preoperative and postoperative weight-bearing anteroposterior and lateral radiographs. Clinical results were evaluated using knee scores and functional scores.

Results

No significant differences in knee scores or functional scores were observed. Polyethylene thickness and flexion/extension gaps were significantly larger in Group B (P < 0.05). The meaningful proximal shift of the joint line was shown in Group B (P < 0.05).

Conclusion

The navigation-assisted TKA with measured gap resection technique could be a useful technique with regard to restoration of the joint line.

Level of evidence

II.
Literature
1.
go back to reference Bäthis H, Perlick L, Tingart M, Lüing C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86:68–682CrossRef Bäthis H, Perlick L, Tingart M, Lüing C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86:68–682CrossRef
2.
3.
go back to reference Catani F, Biasca N, Ensini A, Leardini A, Bianchi L, Digennaro V, Giannini S (2008) Alignment deviation between bone resection and final implant positioning in computer-navigated total knee arthroplasty. J Bone Joint Surg Am 90:765–771PubMedCrossRef Catani F, Biasca N, Ensini A, Leardini A, Bianchi L, Digennaro V, Giannini S (2008) Alignment deviation between bone resection and final implant positioning in computer-navigated total knee arthroplasty. J Bone Joint Surg Am 90:765–771PubMedCrossRef
4.
go back to reference Chin PL, Yang KY, Yeo S, Lo NN (2005) Randomized control trial comparing radiographic TKA implant placement using computer navigation versus conventional technique. J Arthroplasty 20:618–626PubMedCrossRef Chin PL, Yang KY, Yeo S, Lo NN (2005) Randomized control trial comparing radiographic TKA implant placement using computer navigation versus conventional technique. J Arthroplasty 20:618–626PubMedCrossRef
5.
go back to reference Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP (2005) Leg axis after computer-navigated TKA: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty 20:282–288PubMedCrossRef Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP (2005) Leg axis after computer-navigated TKA: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty 20:282–288PubMedCrossRef
6.
go back to reference Donnelly W, Crawford R, Rimmington T, Whitehouse S, Whitting K (2004) Effect of knee navigation on coronal alignment after total knee replacement. J Bone Joint Surg Br 86(Suppl IV):475 Donnelly W, Crawford R, Rimmington T, Whitehouse S, Whitting K (2004) Effect of knee navigation on coronal alignment after total knee replacement. J Bone Joint Surg Br 86(Suppl IV):475
7.
go back to reference Faul F, Erdfelder E, Lang AG, Buchner A (2007) G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods 39:175–191PubMedCrossRef Faul F, Erdfelder E, Lang AG, Buchner A (2007) G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods 39:175–191PubMedCrossRef
8.
go back to reference Figgie HE 3rd, Goldberg VM, Heiple KG, Moller HS 3rd, Gordon NH (1986) The influence of tibial-patellofemoral location on function of the knee in patients with a posterior stabilized condylar knee prosthesis. J Bone Joint Surg Am 68:1035–1040PubMed Figgie HE 3rd, Goldberg VM, Heiple KG, Moller HS 3rd, Gordon NH (1986) The influence of tibial-patellofemoral location on function of the knee in patients with a posterior stabilized condylar knee prosthesis. J Bone Joint Surg Am 68:1035–1040PubMed
9.
go back to reference Haaker R, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A (2005) Computer-assisted navigation increases precision of component placement in TKA. Clin Orthop Relat Res 433:152–159PubMedCrossRef Haaker R, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A (2005) Computer-assisted navigation increases precision of component placement in TKA. Clin Orthop Relat Res 433:152–159PubMedCrossRef
10.
go back to reference Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the knee society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the knee society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed
11.
go back to reference Jung YB, Lee HJ, Jung HJ, Song KS, Lee JS, Yang JJ (2009) Comparison of the radiological results between fluoroscopy-assisted and navigation-guided total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 17:286–292PubMedCrossRef Jung YB, Lee HJ, Jung HJ, Song KS, Lee JS, Yang JJ (2009) Comparison of the radiological results between fluoroscopy-assisted and navigation-guided total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 17:286–292PubMedCrossRef
12.
go back to reference Kawamura H, Bourne RB (2001) Factors affecting range of flexion after total knee arthroplasty. J Orthop Sci 6:248–252PubMedCrossRef Kawamura H, Bourne RB (2001) Factors affecting range of flexion after total knee arthroplasty. J Orthop Sci 6:248–252PubMedCrossRef
13.
go back to reference Laskin RS (2002) Joint line position restoration during revision total knee replacement. Clin Orthop Relat Res 404:169–171PubMedCrossRef Laskin RS (2002) Joint line position restoration during revision total knee replacement. Clin Orthop Relat Res 404:169–171PubMedCrossRef
14.
go back to reference Malghem J, Maldague B (1989) Depth insufficiency of the proximal trochlear groove on lateral radiographs of the knee: relation to patellar dislocation. Radiology 170:507–510PubMed Malghem J, Maldague B (1989) Depth insufficiency of the proximal trochlear groove on lateral radiographs of the knee: relation to patellar dislocation. Radiology 170:507–510PubMed
15.
go back to reference Mason M, Belisle A, Bonutti P, Kolisek FR, Malkani A, Masini M (2006) An accurate and reproducible method for locating the joint line during a revision total knee arthroplasty. J Arthroplasty 21:1147–1153PubMedCrossRef Mason M, Belisle A, Bonutti P, Kolisek FR, Malkani A, Masini M (2006) An accurate and reproducible method for locating the joint line during a revision total knee arthroplasty. J Arthroplasty 21:1147–1153PubMedCrossRef
16.
go back to reference Partington PF, Sawhney J, Rorabeck CH, Barrack RL, Moore J (1999) Joint line restoration after revision total knee arthroplasty. Clin Orthop Relat Res 367:165–171PubMedCrossRef Partington PF, Sawhney J, Rorabeck CH, Barrack RL, Moore J (1999) Joint line restoration after revision total knee arthroplasty. Clin Orthop Relat Res 367:165–171PubMedCrossRef
17.
go back to reference Porteous AJ, Hassaballa MA, Newman JH (2008) Does the joint line matter in revision total knee replacement? J Bone Joint Surg Br 90:879–884PubMedCrossRef Porteous AJ, Hassaballa MA, Newman JH (2008) Does the joint line matter in revision total knee replacement? J Bone Joint Surg Br 90:879–884PubMedCrossRef
18.
go back to reference Selvarajah E, Hooper G (2009) Restoration of the joint line in total knee arthroplasty. J Arthroplasty 24:1099–1102PubMedCrossRef Selvarajah E, Hooper G (2009) Restoration of the joint line in total knee arthroplasty. J Arthroplasty 24:1099–1102PubMedCrossRef
19.
go back to reference Singerman R, Davy DT, Goldberg VM (1994) Effects of patella alta and patella infera on patellofemoral contact forces. J Biomech 27:1059–1065PubMedCrossRef Singerman R, Davy DT, Goldberg VM (1994) Effects of patella alta and patella infera on patellofemoral contact forces. J Biomech 27:1059–1065PubMedCrossRef
20.
go back to reference Singerman R, Heiple KG, Davy DT, Goldberg VM (1995) Effect of tibial component position on patellar strain following total knee arthroplasty. J Arthroplasty 10:651–656PubMedCrossRef Singerman R, Heiple KG, Davy DT, Goldberg VM (1995) Effect of tibial component position on patellar strain following total knee arthroplasty. J Arthroplasty 10:651–656PubMedCrossRef
21.
go back to reference Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830–835PubMed Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830–835PubMed
22.
go back to reference Ten Ham AM, Wymenga AB, Jacobs WC (2005) The use of the knee joint-line balancer to control patella position in revision total knee arthroplasty. Knee 12:89–92PubMedCrossRef Ten Ham AM, Wymenga AB, Jacobs WC (2005) The use of the knee joint-line balancer to control patella position in revision total knee arthroplasty. Knee 12:89–92PubMedCrossRef
23.
go back to reference Tigani D, Sabbioni G, Ben Ayad R, Filanti M, Rani N, Del Piccolo N (2010) Comparison between two computer-assisted total knee arthroplasty: gap-balancing versus measured resection technique. Knee Surg Sports Traumatol Arthrosc 18:1304–1310PubMedCrossRef Tigani D, Sabbioni G, Ben Ayad R, Filanti M, Rani N, Del Piccolo N (2010) Comparison between two computer-assisted total knee arthroplasty: gap-balancing versus measured resection technique. Knee Surg Sports Traumatol Arthrosc 18:1304–1310PubMedCrossRef
24.
go back to reference Yoshii I, Whiteside LA, White SE, Milliano MT (1991) Influence of prosthetic joint line position on knee kinematics and patellar position. J Arthroplasty 6:169–177PubMedCrossRef Yoshii I, Whiteside LA, White SE, Milliano MT (1991) Influence of prosthetic joint line position on knee kinematics and patellar position. J Arthroplasty 6:169–177PubMedCrossRef
Metadata
Title
Comparison of joint line position changes after primary bilateral total knee arthroplasty performed using the navigation-assisted measured gap resection or gap balancing techniques
Authors
Han Jun Lee
Jae Sung Lee
Ho Joong Jung
Kwang Sup Song
Jae Jun Yang
Chi Woo Park
Publication date
01-12-2011
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 12/2011
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-011-1468-2

Other articles of this Issue 12/2011

Knee Surgery, Sports Traumatology, Arthroscopy 12/2011 Go to the issue