Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 7/2010

01-07-2010 | Knee

A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography

Authors: Michael T. Hirschmann, Farhad Iranpour, Praveen Konala, Anna Kerner, Helmut Rasch, Justin P. Cobb, Niklaus F. Friederich

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 7/2010

Login to get access

Abstract

SPECT/CT is a promising diagnostic modality in patients with painful total knee arthroplasty (TKA). The purpose of this study is to introduce a novel standardized SPECT/CT algorithm and evaluate its clinical application and reliability. A novel SPECT/CT localization scheme consisting of 9 tibial, 9 femoral and 4 patellar regions on standardized axial, coronal and sagittal slices is proposed. It was piloted in 18 consecutive patients with post TKA pain. The tracer activity on SPECT/CT was recorded using a color-coded scale (0–10). The inter- and intra-observer reliability was assessed for localization and tracer activity. The prosthetic component position was assessed in the CT images after 3D reconstruction using standardized frames of reference. The median inter- and intra-observer differences and ranges of the measured angles were calculated along with the ICC values for inter- and intra-observer reliability. The localization scheme showed very high inter- and intra-observer reliabilities for all regions. The measurement of component position was highly reliable in all cases with sufficient visibility of anatomical landmarks. The median inter-observer difference between alignment measurements for tibial and femoral components was less than 3° (range 0°–6°). The median intra-observer variability for these was less than 2° (range 0°–5°). The SPECT/CT algorithm presented is both reliable and useful in the management of patients with painful TKA. It combines biomechanical and metabolic data (tracer localization) providing an extra dimension to the understanding of this difficult condition. The clinical value of SPECT/CT in patients with unexplained pain following TKA should be further investigated.
Literature
1.
go back to reference Agriantonis DJ, Hall L, Wilson MA (2009) Utility of SPECT/CT as an adjunct to planar whole body I-131 imaging: liver metastasis from papillary thyroid cancer. Clin Nucl Med 34:247–248CrossRefPubMed Agriantonis DJ, Hall L, Wilson MA (2009) Utility of SPECT/CT as an adjunct to planar whole body I-131 imaging: liver metastasis from papillary thyroid cancer. Clin Nucl Med 34:247–248CrossRefPubMed
2.
go back to reference Bailey E, HoShon I, Roach P (2007) Additional benefit of SPECT/CT in bone scanning of metastatic renal cell carcinoma. Clin Nucl Med 32:411–414CrossRefPubMed Bailey E, HoShon I, Roach P (2007) Additional benefit of SPECT/CT in bone scanning of metastatic renal cell carcinoma. Clin Nucl Med 32:411–414CrossRefPubMed
3.
go back to reference Barrack RL, Schrader T, Bertot AJ, Wolfe MW, Myers L (2001) Component rotation and anterior knee pain after total knee arthroplasty. Clin Orthop Relat Res 392:46–55CrossRefPubMed Barrack RL, Schrader T, Bertot AJ, Wolfe MW, Myers L (2001) Component rotation and anterior knee pain after total knee arthroplasty. Clin Orthop Relat Res 392:46–55CrossRefPubMed
4.
go back to reference Berger RA, Crossett LS, Jacobs JJ, Rubash HE (1998) Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 356:144–153CrossRefPubMed Berger RA, Crossett LS, Jacobs JJ, Rubash HE (1998) Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 356:144–153CrossRefPubMed
5.
go back to reference Bockisch A, Freudenberg LS, Schmidt D, Kuwert T (2009) Hybrid imaging by SPECT/CT and PET/CT: proven outcomes in cancer imaging. Semin Nucl Med 39:276–289CrossRefPubMed Bockisch A, Freudenberg LS, Schmidt D, Kuwert T (2009) Hybrid imaging by SPECT/CT and PET/CT: proven outcomes in cancer imaging. Semin Nucl Med 39:276–289CrossRefPubMed
6.
go back to reference Breunung N, Barwick T, Fernando R, Gnanasegaran G, Vijayanathan S, Hosahalli M et al (2008) Additional benefit of SPECT-CT in investigating heel pain. Clin Nucl Med 33:705–706CrossRefPubMed Breunung N, Barwick T, Fernando R, Gnanasegaran G, Vijayanathan S, Hosahalli M et al (2008) Additional benefit of SPECT-CT in investigating heel pain. Clin Nucl Med 33:705–706CrossRefPubMed
7.
go back to reference Bruni C, Padovano F, Travascio L, Schillaci O, Simonetti G (2008) Usefulness of hybrid SPECT/CT for the 99mTc-HMPAO-labeled leukocyte scintigraphy in a case of cranial osteomyelitis. Braz J Infect Dis 12:558–560CrossRefPubMed Bruni C, Padovano F, Travascio L, Schillaci O, Simonetti G (2008) Usefulness of hybrid SPECT/CT for the 99mTc-HMPAO-labeled leukocyte scintigraphy in a case of cranial osteomyelitis. Braz J Infect Dis 12:558–560CrossRefPubMed
8.
go back to reference Bybel B, Brunken RC, DiFilippo FP, Neumann DR, Wu G, Cerqueira MD (2008) SPECT/CT imaging: clinical utility of an emerging technology. Radiographics 28:1097–1113CrossRefPubMed Bybel B, Brunken RC, DiFilippo FP, Neumann DR, Wu G, Cerqueira MD (2008) SPECT/CT imaging: clinical utility of an emerging technology. Radiographics 28:1097–1113CrossRefPubMed
9.
go back to reference Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM (2004) Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol). J Bone Joint Surg Br 86:818–823CrossRefPubMed Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM (2004) Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol). J Bone Joint Surg Br 86:818–823CrossRefPubMed
10.
go back to reference Chowdhury FU, Scarsbrook AF (2008) The role of hybrid SPECT-CT in oncology: current and emerging clinical applications. Clin Radiol 63:241–251CrossRefPubMed Chowdhury FU, Scarsbrook AF (2008) The role of hybrid SPECT-CT in oncology: current and emerging clinical applications. Clin Radiol 63:241–251CrossRefPubMed
11.
go back to reference d‘ Amico A, Szczucka K, Borys D, Gorczewski K, Steinhof K (2006) SPECT-CT fusion a new diagnostic tool for endocrinology. Endokrynol Pol 57(Suppl A):71–74 d‘ Amico A, Szczucka K, Borys D, Gorczewski K, Steinhof K (2006) SPECT-CT fusion a new diagnostic tool for endocrinology. Endokrynol Pol 57(Suppl A):71–74
12.
go back to reference Filippi L, Uccioli L, Giurato L, Schillaci O (2009) Diabetic foot infection: usefulness of SPECT/CT for 99mTc-HMPAO-labeled leukocyte imaging. J Nucl Med 50:1042–1046CrossRefPubMed Filippi L, Uccioli L, Giurato L, Schillaci O (2009) Diabetic foot infection: usefulness of SPECT/CT for 99mTc-HMPAO-labeled leukocyte imaging. J Nucl Med 50:1042–1046CrossRefPubMed
13.
go back to reference Henckel J, Richards R, Lozhkin K, Harris S, Baena FM, Barrett AR et al (2006) Very low-dose computed tomography for planning and outcome measurement in knee replacement. The imperial knee protocol. Bone Joint Surg Br 88:1513–1518CrossRef Henckel J, Richards R, Lozhkin K, Harris S, Baena FM, Barrett AR et al (2006) Very low-dose computed tomography for planning and outcome measurement in knee replacement. The imperial knee protocol. Bone Joint Surg Br 88:1513–1518CrossRef
14.
go back to reference Hirschmann MT, Iranpour F, Davda K, Rasch H, Hugli R, Friederich NF (2009) Combined single-photon emission computerized tomography and conventional computerized tomography (SPECT/CT): clinical value for the knee surgeons? Knee Surg Sports Traumatol Arthrosc. doi: 10.1007/s00167-009-0879-9 Hirschmann MT, Iranpour F, Davda K, Rasch H, Hugli R, Friederich NF (2009) Combined single-photon emission computerized tomography and conventional computerized tomography (SPECT/CT): clinical value for the knee surgeons? Knee Surg Sports Traumatol Arthrosc. doi: 10.​1007/​s00167-009-0879-9
15.
go back to reference Horger M, Eschmann SM, Pfannenberg C, Storek D, Vonthein R, Claussen CD et al (2007) Added value of SPECT/CT in patients suspected of having bone infection: preliminary results. Arch Orthop Trauma Surg 127:211–221CrossRefPubMed Horger M, Eschmann SM, Pfannenberg C, Storek D, Vonthein R, Claussen CD et al (2007) Added value of SPECT/CT in patients suspected of having bone infection: preliminary results. Arch Orthop Trauma Surg 127:211–221CrossRefPubMed
16.
go back to reference Kanekasu K, Kondo M, Kadoya Y (2005) Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 434:193–197CrossRefPubMed Kanekasu K, Kondo M, Kadoya Y (2005) Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 434:193–197CrossRefPubMed
17.
go back to reference Knupp M, Pagenstert GI, Barg A, Bolliger L, Easley ME, Hintermann B (2009) SPECT-CT compared with conventional imaging modalities for the assessment of the varus and valgus malaligned hindfoot. J Orthop Res 7:1461–1466CrossRef Knupp M, Pagenstert GI, Barg A, Bolliger L, Easley ME, Hintermann B (2009) SPECT-CT compared with conventional imaging modalities for the assessment of the varus and valgus malaligned hindfoot. J Orthop Res 7:1461–1466CrossRef
18.
go back to reference Lee A, Emmett L, Van der Wall H, Kannangara S, Mansberg R, Fogelman I (2008) SPECT/CT of femeroacetabular impingement. Clin Nucl Med 33:757–762CrossRefPubMed Lee A, Emmett L, Van der Wall H, Kannangara S, Mansberg R, Fogelman I (2008) SPECT/CT of femeroacetabular impingement. Clin Nucl Med 33:757–762CrossRefPubMed
19.
go back to reference Longstaff LM, Sloan K, Stamp N, Scaddan M, Beaver R (2009) Good alignment after total knee arthroplasty leads to faster rehabilitation and better function. J Arthroplasty 24:570–578CrossRefPubMed Longstaff LM, Sloan K, Stamp N, Scaddan M, Beaver R (2009) Good alignment after total knee arthroplasty leads to faster rehabilitation and better function. J Arthroplasty 24:570–578CrossRefPubMed
20.
go back to reference Madsen JL (2008) Bone SPECT/CT detection of a sequestrum in chronic-infected nonunion of the tibia. Clin Nucl Med 33:700–701CrossRefPubMed Madsen JL (2008) Bone SPECT/CT detection of a sequestrum in chronic-infected nonunion of the tibia. Clin Nucl Med 33:700–701CrossRefPubMed
21.
go back to reference Mahmarian JJ (2007) Hybrid SPECT-CT: integration of CT coronary artery calcium scoring and angiography with myocardial perfusion. Curr Cardiol Rep 9:129–135CrossRefPubMed Mahmarian JJ (2007) Hybrid SPECT-CT: integration of CT coronary artery calcium scoring and angiography with myocardial perfusion. Curr Cardiol Rep 9:129–135CrossRefPubMed
22.
go back to reference Nomayr A, Romer W, Strobel D, Bautz W, Kuwert T (2006) Anatomical accuracy of hybrid SPECT/spiral CT in the lower spine. Nucl Med Commun 27:521–528CrossRefPubMed Nomayr A, Romer W, Strobel D, Bautz W, Kuwert T (2006) Anatomical accuracy of hybrid SPECT/spiral CT in the lower spine. Nucl Med Commun 27:521–528CrossRefPubMed
23.
go back to reference Roarke MC, Nguyen BD, Pockaj BA (2008) Applications of SPECT/CT in nuclear radiology. AJR Am J Roentgenol 191:W135–W150CrossRefPubMed Roarke MC, Nguyen BD, Pockaj BA (2008) Applications of SPECT/CT in nuclear radiology. AJR Am J Roentgenol 191:W135–W150CrossRefPubMed
24.
go back to reference Romero J, Stahelin T, Wyss T, Hofmann S (2003) Significance of axial rotation alignment of components of knee prostheses. Orthopade 32:461–468PubMed Romero J, Stahelin T, Wyss T, Hofmann S (2003) Significance of axial rotation alignment of components of knee prostheses. Orthopade 32:461–468PubMed
25.
go back to reference Sacchetti GM, Ghisellini F, Brambilla M, De Consoli A, Fornara P, Rizzo E et al (1996) Quantitative scintigraphic evaluation of total knee arthroplasties: a feasibility study. Clin Orthop Relat Res 325:181–189CrossRefPubMed Sacchetti GM, Ghisellini F, Brambilla M, De Consoli A, Fornara P, Rizzo E et al (1996) Quantitative scintigraphic evaluation of total knee arthroplasties: a feasibility study. Clin Orthop Relat Res 325:181–189CrossRefPubMed
26.
27.
go back to reference Schillaci O, Danieli R, Manni C, Simonetti G (2004) Is SPECT/CT with a hybrid camera useful to improve scintigraphic imaging interpretation? Nucl Med Commun 25:705–710CrossRefPubMed Schillaci O, Danieli R, Manni C, Simonetti G (2004) Is SPECT/CT with a hybrid camera useful to improve scintigraphic imaging interpretation? Nucl Med Commun 25:705–710CrossRefPubMed
28.
go back to reference Shcherbinin S, Celler A, Belhocine T, Vanderwerf R, Driedger A (2008) Accuracy of quantitative reconstructions in SPECT/CT imaging. Phys Med Biol 53:4595–4604CrossRefPubMed Shcherbinin S, Celler A, Belhocine T, Vanderwerf R, Driedger A (2008) Accuracy of quantitative reconstructions in SPECT/CT imaging. Phys Med Biol 53:4595–4604CrossRefPubMed
29.
go back to reference Sikorski JM (2004) Computer-assisted revision total knee replacement. J Bone Joint Surg Br 86:510–514PubMed Sikorski JM (2004) Computer-assisted revision total knee replacement. J Bone Joint Surg Br 86:510–514PubMed
30.
go back to reference van der Ploeg IM, Valdes Olmos RA, Kroon BB, Nieweg OE (2008) The Hybrid SPECT/CT as an additional lymphatic mapping tool in patients with breast cancer. World J Surg 32:1930–1934CrossRefPubMed van der Ploeg IM, Valdes Olmos RA, Kroon BB, Nieweg OE (2008) The Hybrid SPECT/CT as an additional lymphatic mapping tool in patients with breast cancer. World J Surg 32:1930–1934CrossRefPubMed
31.
go back to reference Victor J (2009) Rotational alignment of the distal femur: a literature review. Orthop Traumatol Surg Res 95:365–372CrossRefPubMed Victor J (2009) Rotational alignment of the distal femur: a literature review. Orthop Traumatol Surg Res 95:365–372CrossRefPubMed
32.
go back to reference Victor J, Van Doninck D, Labey L, Innocenti B, Parizel PM, Bellemans J (2009) How precise can bony landmarks be determined on a CT scan of the knee? Knee 16:358–365CrossRefPubMed Victor J, Van Doninck D, Labey L, Innocenti B, Parizel PM, Bellemans J (2009) How precise can bony landmarks be determined on a CT scan of the knee? Knee 16:358–365CrossRefPubMed
33.
go back to reference Walter SD, Eliasziw M, Donner A (1998) Sample size and optimal designs for reliability studies. Stat Med 17:101–110CrossRefPubMed Walter SD, Eliasziw M, Donner A (1998) Sample size and optimal designs for reliability studies. Stat Med 17:101–110CrossRefPubMed
34.
go back to reference Zihlmann MS, Stacoff A, Romero J, Quervain IK, Stussi E (2005) Biomechanical background and clinical observations of rotational malalignment in TKA: literature review and consequences. Clin Biomech (Bristol, Avon) 20:661–668CrossRef Zihlmann MS, Stacoff A, Romero J, Quervain IK, Stussi E (2005) Biomechanical background and clinical observations of rotational malalignment in TKA: literature review and consequences. Clin Biomech (Bristol, Avon) 20:661–668CrossRef
Metadata
Title
A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography
Authors
Michael T. Hirschmann
Farhad Iranpour
Praveen Konala
Anna Kerner
Helmut Rasch
Justin P. Cobb
Niklaus F. Friederich
Publication date
01-07-2010
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 7/2010
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-010-1070-z

Other articles of this Issue 7/2010

Knee Surgery, Sports Traumatology, Arthroscopy 7/2010 Go to the issue