Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 7/2008

01-07-2008 | Knee

Cutting errors in total knee replacement: assessment by computer assisted surgery

Authors: W. P. Yau, K. Y. Chiu

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 7/2008

Login to get access

Abstract

The observed errors in the position of the implanted prosthesis can be due to a number of potential causes. One of these is the potential error during execution of the bone cuts. However, there is only minimal information on this in the current literature. The amount of cutting errors in 40 consecutive total knee replacements was reported. All the operations were done by the same surgeon. The amount of cutting error was measured by the use of computer navigation system. It was hypothesized that there was no difference in the amount of error between bone cut through the cutting slot (slotted cutting) and bone cut done on the surface of the cutting guide (open cutting). It was found that the average absolute cutting error was 1º in the coronal plane and 1.4º in the sagittal plane. Significantly more outlier (more than 3º) was observed in the errors in the sagittal plane (P = 0.014, chi square test). Open cutting resulted in less error in the sagittal plane of the tibial cut when compared with slotted cutting (P = 0.031, Mann–Whitney U Test). This was attributed by the use of a thicker saw blade with higher stiffness in the open cutting method.
Literature
1.
go back to reference Bathis H, Perlick L, Tingart M (2005) Intraoperative cutting errors in total knee arthroplasty. Arch Orthop Trauma Surg 125:16–20PubMedCrossRef Bathis H, Perlick L, Tingart M (2005) Intraoperative cutting errors in total knee arthroplasty. Arch Orthop Trauma Surg 125:16–20PubMedCrossRef
2.
go back to reference Bono JV, Roger DJ, Laskin RS, Peterson MG, Paulsen CA (1995) Tibial intramedullary alignment in total knee arthroplasty. American J Knee Surg 8:7–11 Bono JV, Roger DJ, Laskin RS, Peterson MG, Paulsen CA (1995) Tibial intramedullary alignment in total knee arthroplasty. American J Knee Surg 8:7–11
3.
go back to reference Brys DA, Lombardi AV Jr, Mallory TH, Vaughn BK (1991) A comparison of intramedullary and extramedullary alignment systems for tibial component placement in total knee arthroplasty. Clin Orthop 263:175–179PubMed Brys DA, Lombardi AV Jr, Mallory TH, Vaughn BK (1991) A comparison of intramedullary and extramedullary alignment systems for tibial component placement in total knee arthroplasty. Clin Orthop 263:175–179PubMed
4.
go back to reference Elloy MA, Manning MP, Johnson R (1992) Accuracy of intramedullary alignment in total knee replacement. J Biomed Eng 14:363–370PubMedCrossRef Elloy MA, Manning MP, Johnson R (1992) Accuracy of intramedullary alignment in total knee replacement. J Biomed Eng 14:363–370PubMedCrossRef
5.
go back to reference Insall JN, Binazzi R, Soudry M, Mestriner LA (1985) Total knee arthroplasty. Clin Orthop 192:13–22PubMed Insall JN, Binazzi R, Soudry M, Mestriner LA (1985) Total knee arthroplasty. Clin Orthop 192:13–22PubMed
6.
go back to reference Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73-B:709–714 Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73-B:709–714
7.
go back to reference Ko PS, Tio MK, Ban CM, Mak YK, Ip FK, Lam JJ (2001) Radiologic analysis of the tibial intramedullary canal in Chinese varus knees Implications in total knee arthroplasty. J Arthroplasty 16:212–215PubMedCrossRef Ko PS, Tio MK, Ban CM, Mak YK, Ip FK, Lam JJ (2001) Radiologic analysis of the tibial intramedullary canal in Chinese varus knees Implications in total knee arthroplasty. J Arthroplasty 16:212–215PubMedCrossRef
8.
go back to reference Maestro A, Harwin SF, Sandoval MG, Vaquero DH, Murcia A (1998) Influence of intramedullary versus extramedullary guides on final total knee arthroplasty component position: a radiographic analysis. J Arthroplasty 13:552–558PubMedCrossRef Maestro A, Harwin SF, Sandoval MG, Vaquero DH, Murcia A (1998) Influence of intramedullary versus extramedullary guides on final total knee arthroplasty component position: a radiographic analysis. J Arthroplasty 13:552–558PubMedCrossRef
9.
go back to reference Plaskos C, Hodgson AJ, Inkpen K, McGraw RW (2002) Bone cutting errors in total knee arthroplasty. J Arthroplasty 17:698–705PubMedCrossRef Plaskos C, Hodgson AJ, Inkpen K, McGraw RW (2002) Bone cutting errors in total knee arthroplasty. J Arthroplasty 17:698–705PubMedCrossRef
10.
go back to reference Rand JA, Coventry MB (1988) Ten-year evaluation of geometric total knee arthroplasty. Clin Orthop 232:168–173PubMed Rand JA, Coventry MB (1988) Ten-year evaluation of geometric total knee arthroplasty. Clin Orthop 232:168–173PubMed
11.
go back to reference Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop 299:153–156PubMed Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop 299:153–156PubMed
12.
go back to reference Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am 84-A(Supp 2):90–98PubMed Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am 84-A(Supp 2):90–98PubMed
13.
go back to reference Teter KE, Bregman D, Colwell CWJ (1995) Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty. Clin Orthop 321:106–110PubMed Teter KE, Bregman D, Colwell CWJ (1995) Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty. Clin Orthop 321:106–110PubMed
14.
go back to reference Yang SH, Liu TK (1998) Intramedullary versus extramedullary tibial alignment guides in total knee arthroplasty. J Formos Med Assoc 97:564–568PubMed Yang SH, Liu TK (1998) Intramedullary versus extramedullary tibial alignment guides in total knee arthroplasty. J Formos Med Assoc 97:564–568PubMed
Metadata
Title
Cutting errors in total knee replacement: assessment by computer assisted surgery
Authors
W. P. Yau
K. Y. Chiu
Publication date
01-07-2008
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 7/2008
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-008-0550-x

Other articles of this Issue 7/2008

Knee Surgery, Sports Traumatology, Arthroscopy 7/2008 Go to the issue