Abstract

Computer-assisted orthopedic surgery (CAOS) for total knee arthroplasty is an emerging surgical tool, yet little is known about how it is being used in everyday orthopedic centers. We sought to better understand physicians’ current practices and beliefs on this topic through performing a Web-based survey. Between December 2006 and January 2007, a 24-question survey was emailed to 3,330 members of the European Society of Sports Traumatology Knee Surgery and Arthroscopy (ESSKA) and the Swiss Orthopedic Society (SGO-SSO), with 389 (11.7%) agreeing to participate. Of this group, 202 (51.9%) reported that their center was equipped with a navigation system, which was an image-free based system for most (83.2%) and was primarily used for total knee arthroplasty (61.4%). In terms of the proportion of use, 50.5% of respondents used their navigation system in less than 25% of cases, 16.3% in 25–50% of cases, 7.4% in 51–75% of cases, and 25.7% in more than 75% of cases. The potential for improving the alignment of prosthesis was the most strongly cited reason for using a navigation system, while the potential for increasing operation times and the risk of infections were the most strongly cited reasons for not using a navigation system. Approximately half of respondents surveyed believed navigation systems were a real innovation contributing to the improvement of total knee implantation. However, heavy usage of computer-assisted navigation (≥51% of cases) was observed in only 33.1% of respondents, with only a quarter using it at rates that could be considered frequent (>75% of cases). Forty-eight percent of respondents said they will use a navigation system in more cases and 39.1% that their usage will stay the same. These findings indicate that CAOS is being used only moderately in current practices, though respondents generally had a positive opinion of its potential benefits. Physicians may be awaiting more data before adopting the use of these systems, though survey responses also suggest a projected increase in their use in the coming years.
Literature
1.
2.
go back to reference Davies BL, Rodriguez y Baena FM, Barrett AR, Gomes MP, Harris SJ, Jakopec M, Cobb JP (2007) Robotic control in knee joint replacement surgery. Proc Inst Mech Eng [H] 221:71–80 Davies BL, Rodriguez y Baena FM, Barrett AR, Gomes MP, Harris SJ, Jakopec M, Cobb JP (2007) Robotic control in knee joint replacement surgery. Proc Inst Mech Eng [H] 221:71–80
3.
go back to reference Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement. A meta-analysis. J Bone Joint Surg Am 89:261–269PubMedCrossRef Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement. A meta-analysis. J Bone Joint Surg Am 89:261–269PubMedCrossRef
4.
go back to reference Callaghan JJ, Liu SS, Warth LC (2006) Computer-assisted surgery: a wine before its time: in the affirmative. J Arthroplasty 21(4 Suppl 1):27–28PubMedCrossRef Callaghan JJ, Liu SS, Warth LC (2006) Computer-assisted surgery: a wine before its time: in the affirmative. J Arthroplasty 21(4 Suppl 1):27–28PubMedCrossRef
5.
go back to reference Macule-Beneyto F, Hernandez-Vaquero D, Segur-Vilalta JM, Colomina-Rodriguez R, Hinarejos-Gomez P, Garcia-Forcada I, Seral Garcia B (2006) Navigation in total knee arthroplasty. A multicenter study. Int Orthop 30:536–540PubMedCrossRef Macule-Beneyto F, Hernandez-Vaquero D, Segur-Vilalta JM, Colomina-Rodriguez R, Hinarejos-Gomez P, Garcia-Forcada I, Seral Garcia B (2006) Navigation in total knee arthroplasty. A multicenter study. Int Orthop 30:536–540PubMedCrossRef
6.
go back to reference Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM (2002) Insall Award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res 404:7–13PubMedCrossRef Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM (2002) Insall Award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res 404:7–13PubMedCrossRef
7.
go back to reference Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156PubMed Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156PubMed
8.
go back to reference Dong H, Buxton M (2006) Early assessment of the likely cost-effectiveness of a new technology: a Markov model with probabilistic sensitivity analysis of computer-assisted total knee replacement. Int J Technol Assess Health Care 22:191–202PubMedCrossRef Dong H, Buxton M (2006) Early assessment of the likely cost-effectiveness of a new technology: a Markov model with probabilistic sensitivity analysis of computer-assisted total knee replacement. Int J Technol Assess Health Care 22:191–202PubMedCrossRef
9.
go back to reference Stulberg SD (2003) How accurate is current TKR instrumentation? Clin Orthop Relat Res 415:177–184CrossRef Stulberg SD (2003) How accurate is current TKR instrumentation? Clin Orthop Relat Res 415:177–184CrossRef
10.
go back to reference Bathis H, Perlick L, Tingart M, Lüring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computerassisted surgery with the conventional technique. J Bone Joint Surg Br 86:682–687PubMedCrossRef Bathis H, Perlick L, Tingart M, Lüring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computerassisted surgery with the conventional technique. J Bone Joint Surg Br 86:682–687PubMedCrossRef
11.
go back to reference Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res 433:152–159PubMedCrossRef Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res 433:152–159PubMedCrossRef
12.
go back to reference Victor J, Hoste D (2004) Image-based computer-assisted total knee arthroplasty leads to lower variability in coronal alignment. Clin Orthop Relat Res 428:131–139PubMedCrossRef Victor J, Hoste D (2004) Image-based computer-assisted total knee arthroplasty leads to lower variability in coronal alignment. Clin Orthop Relat Res 428:131–139PubMedCrossRef
13.
go back to reference Picard F, Deakin AH, Clarke JV, Dillon JM, Gregori A (2007) Using navigation intraoperative measurements narrows range of outcomes in TKA. Clin Orthop Relat Res 463:50–57, (Epub ahead of print)PubMed Picard F, Deakin AH, Clarke JV, Dillon JM, Gregori A (2007) Using navigation intraoperative measurements narrows range of outcomes in TKA. Clin Orthop Relat Res 463:50–57, (Epub ahead of print)PubMed
14.
go back to reference Cobb J, Henckel J, Gomes P, Harris S, Jakopec M, Rodriguez F, Barrett A, Davies B (2006) Hands-on robotic unicompartmental knee replacement: a prospective, randomised controlled study of the acrobot system. J Bone Joint Surg Br 88:188–197PubMed Cobb J, Henckel J, Gomes P, Harris S, Jakopec M, Rodriguez F, Barrett A, Davies B (2006) Hands-on robotic unicompartmental knee replacement: a prospective, randomised controlled study of the acrobot system. J Bone Joint Surg Br 88:188–197PubMed
15.
go back to reference Chauhan SK, Scott RG, Breidahl W, Beaver RJ (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Joint Surg Br 86:372–377PubMedCrossRef Chauhan SK, Scott RG, Breidahl W, Beaver RJ (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Joint Surg Br 86:372–377PubMedCrossRef
16.
go back to reference Daubresse F, Vajeu C, Loquet J (2005) Total knee arthroplasty with conventional or navigated technique: comparison of the learning curves in a community hospital. Acta Orthop Belg 71:710–713PubMed Daubresse F, Vajeu C, Loquet J (2005) Total knee arthroplasty with conventional or navigated technique: comparison of the learning curves in a community hospital. Acta Orthop Belg 71:710–713PubMed
18.
go back to reference Siston RA, Giori NJ, Goodman SB, Delp SL (2007) Surgical navigation for total knee arthroplasty: a perspective. J Biomech 40:728–735PubMedCrossRef Siston RA, Giori NJ, Goodman SB, Delp SL (2007) Surgical navigation for total knee arthroplasty: a perspective. J Biomech 40:728–735PubMedCrossRef
19.
go back to reference Kalairajah Y, Simpson D, Cossey AJ, Verrall GM, Spriggins AJ (2005) Blood loss after total knee replacement: effects of computer-assisted surgery. J Bone Joint Surg Br 87:1480–1482PubMedCrossRef Kalairajah Y, Simpson D, Cossey AJ, Verrall GM, Spriggins AJ (2005) Blood loss after total knee replacement: effects of computer-assisted surgery. J Bone Joint Surg Br 87:1480–1482PubMedCrossRef
20.
go back to reference Kalairajah Y, Cossey AJ, Verrall GM, Ludbrook G, Spriggins AJ (2006) Are systemic emboli reduced in computer-assisted knee surgery? A prospective, randomised, clinical trial. J Bone Joint Surg Br 88:198–202PubMed Kalairajah Y, Cossey AJ, Verrall GM, Ludbrook G, Spriggins AJ (2006) Are systemic emboli reduced in computer-assisted knee surgery? A prospective, randomised, clinical trial. J Bone Joint Surg Br 88:198–202PubMed
21.
go back to reference Perlick L, Bathis H, Perlick C, Luring C, Tingart M, Grifka J (2005) Revision total knee arthroplasty: a comparison of postoperative leg alignment after computer-assisted implantation versus the conventional technique. Knee Surg Sports Traumatol Arthrosc 13:167–173PubMedCrossRef Perlick L, Bathis H, Perlick C, Luring C, Tingart M, Grifka J (2005) Revision total knee arthroplasty: a comparison of postoperative leg alignment after computer-assisted implantation versus the conventional technique. Knee Surg Sports Traumatol Arthrosc 13:167–173PubMedCrossRef
Metadata
Title
The use of computer-assisted orthopedic surgery for total knee replacement in daily practice: a survey among ESSKA/SGO-SSO members
Authors
N. Friederich
R. Verdonk
Publication date
01-06-2008
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 6/2008
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-008-0518-x

Other articles of this Issue 6/2008

Knee Surgery, Sports Traumatology, Arthroscopy 6/2008 Go to the issue