Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 4/2006

01-04-2006 | Knee

Meniscal bucket handle tears: a retrospective study of arthroscopy and the relation to MRI

Authors: A. N. Ververidis, D. A. Verettas, K. J. Kazakos, C. E. Tilkeridis, C. N. Chatzipapas

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 4/2006

Login to get access

Abstract

In this study, we aim to evaluate the arthroscopic findings of meniscal bucket handle tears and to correlate them with the proposed MR imaging signs of meniscal bucket handle tears suggested in the literature. Thirty-six patients who had a diagnosis of bucket handle tear in arthroscopy, in either medial or lateral meniscus, were included in our study (32 males and 4 females). Meniscal tears were evaluated in arthroscopy according to Dandy’s classification. The MRIs were retrospectively analyzed regarding the following findings: absence of bow tie sign, presence of double posterior cruciate ligament (PCL) sign, double anterior horn sign, flipped meniscus sign, disproportional posterior horn sign, and fragment within the intercondylar region. Locked types I and II fragment of medial meniscus and half-length, whole-width and whole length–half-width fragment of lateral meniscus in arthroscopy were basically correlated with fragment within the intercondylar notch and absent bow tie signs in MRI. We did not find the double PCL sign in any of the patients with a lateral meniscal bucket handle tear. The most common signs in MR images of meniscal bucket handle tears were the fragment in the notch sign and the absent bow tie sign. They were observed with equal frequency of 88.8%. The presence of double PCL sign, double anterior horn sign, flipped meniscus sign, disproportional posterior horn sign were less common (41.66, 33, 25, and 27.7%, respectively). We conclude that the presence of at least two of the six MRI signs should be regarded as highly suggestive for bucket handle tears of menisci.
Literature
1.
go back to reference Chen HC, Hsu CY, Shih TT, Huag KM, Li YW (2001) MR imaging of displaced meniscal tear of the knee: importance of a “disproportional posterior horn sign”. Acta Radiol 42:417–421PubMed Chen HC, Hsu CY, Shih TT, Huag KM, Li YW (2001) MR imaging of displaced meniscal tear of the knee: importance of a “disproportional posterior horn sign”. Acta Radiol 42:417–421PubMed
2.
go back to reference Dandy DJ (1990). The arthroscopic anatomy of symptomatic meniscal lesions. J Bone Joint Surg Br 72:628–633PubMed Dandy DJ (1990). The arthroscopic anatomy of symptomatic meniscal lesions. J Bone Joint Surg Br 72:628–633PubMed
3.
go back to reference Fisher SP, Fox JM, Del Pizzo W, Friedman MJ, Snyder SJ, Ferkel RD (1991) Accuracy of diagnoses from magnetic resonance imaging of the knee. A multi-center analysis of one thousand and fourteen patients. J Bone Joint Surg Am 73:2–10PubMed Fisher SP, Fox JM, Del Pizzo W, Friedman MJ, Snyder SJ, Ferkel RD (1991) Accuracy of diagnoses from magnetic resonance imaging of the knee. A multi-center analysis of one thousand and fourteen patients. J Bone Joint Surg Am 73:2–10PubMed
4.
go back to reference Haramatti N, Staron RB, Kierman H (1993) The flipped meniscus sign. Skeletal Radiol 22:273–277PubMed Haramatti N, Staron RB, Kierman H (1993) The flipped meniscus sign. Skeletal Radiol 22:273–277PubMed
5.
go back to reference Helms CA, Laorr A, Cannon WD (1998) The absent bow tie sign in bucket handle tears of the menisci in the knee. Am J Roentgenol 170:57–61 Helms CA, Laorr A, Cannon WD (1998) The absent bow tie sign in bucket handle tears of the menisci in the knee. Am J Roentgenol 170:57–61
6.
go back to reference Jackson DW, Jenning LD, Maywood RM, Berger PE (1988) Magnetic resonance imaging of the knee. Am J Sports Med 16:29–38PubMed Jackson DW, Jenning LD, Maywood RM, Berger PE (1988) Magnetic resonance imaging of the knee. Am J Sports Med 16:29–38PubMed
7.
8.
go back to reference Mandelbraum BR, Finerman GA, Reicher MA, Hartzman S, Bassett LW, Gold RH, Rauschning W, Dorey F (1986) Magnetic resonance imaging as a tool for evaluation of traumatic knee injuries. Am J Sports Med 14:361–370PubMed Mandelbraum BR, Finerman GA, Reicher MA, Hartzman S, Bassett LW, Gold RH, Rauschning W, Dorey F (1986) Magnetic resonance imaging as a tool for evaluation of traumatic knee injuries. Am J Sports Med 14:361–370PubMed
9.
go back to reference Polly DW, Callachan JJ, Sikes RA, McCabe JM, McMahon K, Savory CG (1988) The accuracy of selective magnetic resonace imaging compared with the finding of arthroscopy of the knee. J Bone Joint Surg Am 70:192–198PubMed Polly DW, Callachan JJ, Sikes RA, McCabe JM, McMahon K, Savory CG (1988) The accuracy of selective magnetic resonace imaging compared with the finding of arthroscopy of the knee. J Bone Joint Surg Am 70:192–198PubMed
10.
go back to reference Reicher MA, Hartzman S, Duckwiler GR, Bassett LW, Anderson LJ, Gold RH (1986) Meniscal injuries: detection using MR imaging. Radiology 159:753–757PubMed Reicher MA, Hartzman S, Duckwiler GR, Bassett LW, Anderson LJ, Gold RH (1986) Meniscal injuries: detection using MR imaging. Radiology 159:753–757PubMed
11.
go back to reference Ruff C, Weingardt JP, Russ PD, Kilcoyne RF (1998) MR imaging patterns of displaced meniscus injuries of the knee. Am J Roentgenol 170:63–67 Ruff C, Weingardt JP, Russ PD, Kilcoyne RF (1998) MR imaging patterns of displaced meniscus injuries of the knee. Am J Roentgenol 170:63–67
12.
go back to reference Shakespeare DT, Rigby HS (1983) Bucket handle tear of the meniscus. J Bone Joint Surg Br 65:383–387PubMed Shakespeare DT, Rigby HS (1983) Bucket handle tear of the meniscus. J Bone Joint Surg Br 65:383–387PubMed
13.
go back to reference Silva I, Silver DM (1988) Tears of the meniscus as revealed by magnetic resonance imaging. J Bone Joint Surg Am 70:199–202PubMed Silva I, Silver DM (1988) Tears of the meniscus as revealed by magnetic resonance imaging. J Bone Joint Surg Am 70:199–202PubMed
14.
15.
go back to reference Weiss KL, Morehouse HT, Levy IM (1991) Sagittal MR images of the knee: low signal band parallel to the posterior cruciate ligament caused by a displaced bucket-handle tear. Am J Roetgenol 156:117–119 Weiss KL, Morehouse HT, Levy IM (1991) Sagittal MR images of the knee: low signal band parallel to the posterior cruciate ligament caused by a displaced bucket-handle tear. Am J Roetgenol 156:117–119
16.
go back to reference Wright DH, De Smet AA, Norris M (1995) Bucket handle tear of the medial and lateral menisci of the knee: value of MR imaging in detecting displaced fragments. Am J Roentgenol 165:621–625 Wright DH, De Smet AA, Norris M (1995) Bucket handle tear of the medial and lateral menisci of the knee: value of MR imaging in detecting displaced fragments. Am J Roentgenol 165:621–625
17.
go back to reference Watt AJ, Halliday T, Raby N (2002) The value of absent bow tie sign in MRI of bucket handle tears. Clin Radiol 55:622–626CrossRef Watt AJ, Halliday T, Raby N (2002) The value of absent bow tie sign in MRI of bucket handle tears. Clin Radiol 55:622–626CrossRef
18.
go back to reference Aydingöz Ü, Firat AK, Ahmet Atay O, Nedium Doral M (2003) MR imaging of meniscal bucket handle tears: a review of signs and their relation to arthroscopic classification. Eur Radiol 13:618–625PubMed Aydingöz Ü, Firat AK, Ahmet Atay O, Nedium Doral M (2003) MR imaging of meniscal bucket handle tears: a review of signs and their relation to arthroscopic classification. Eur Radiol 13:618–625PubMed
Metadata
Title
Meniscal bucket handle tears: a retrospective study of arthroscopy and the relation to MRI
Authors
A. N. Ververidis
D. A. Verettas
K. J. Kazakos
C. E. Tilkeridis
C. N. Chatzipapas
Publication date
01-04-2006
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 4/2006
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-005-0678-x

Other articles of this Issue 4/2006

Knee Surgery, Sports Traumatology, Arthroscopy 4/2006 Go to the issue