The value of electrical impedance tomography in assessing the effect of body position and positive airway pressures on regional lung ventilation in spontaneously breathing subjects
Authors:
Thomas Riedel, Tanya Richards, Andreas Schibler
Published in:
Intensive Care Medicine
|
Issue 11/2005
Login to get access
Abstract
Objective
Functional electrical impedance tomography (EIT) measures relative impedance changes in lung tissue during tidal breathing and creates images of local ventilation distribution. A novel approach to analyse the effect of body position and positive pressure ventilation on intrapulmonary tidal volume distribution was evaluated in healthy adult subjects.
Design and setting
Prospective experimental study in healthy adult subjects in the intensive care unit at university hospital.
Subjects
Ten healthy male adults.
Interventions
Change in body position from supine to prone, left and right lateral during spontaneous breathing and positive pressure support ventilation.
Measurements and results
EIT measurements and multiple-breath sulphur hexafluoride (SF6) washout were performed. Profiles of average relative impedance change in regional lung areas were calculated. Relative impedance time course analysis and Lissajous figure loop analysis were used to calculate phase angles between dependent or independent lung and total lung (φ). EIT data were compared to SF6 data washout measuring the lung clearance index (LCI). Proposed EIT profiles allowed inter-individual comparison of EIT data and identified areas with reduced regional tidal volume using pressure support ventilation. Phase angle φ of dependent lung in supine position was 11.7±1.4°, in prone 5.3±0.5°, in right lateral 11.0±1.3° and in left lateral position 10.8±1.0°. LCI increased in supine position from 5.63±0.43 to 7.13±0.64 in prone position. Measured φ showed inverse relationship to LCI in the four different body positions.
Conclusions
EIT profiles and φ of functional EIT are new methods to describe regional ventilation distribution with EIT allowing inter-individual comparison.