Skip to main content
Top
Published in: Intensive Care Medicine 9/2005

01-09-2005 | Original

Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients

Authors: Xavier Monnet, Mario Rienzo, David Osman, Nadia Anguel, Christian Richard, Michael R. Pinsky, Jean-Louis Teboul

Published in: Intensive Care Medicine | Issue 9/2005

Login to get access

Abstract

Objective

To test whether fluid responsiveness can be predicted by the respiratory variation in aortic blood flow and/or the flow time corrected for heart rate monitored with esophageal Doppler.

Design and setting

Prospective study in a 24-bed medical intensive care unit of a university hospital.

Patients

38 mechanically ventilated patients with sinus rhythm and without spontaneous breathing activity in whom volume expansion was planned.

Interventions

The aortic blood flow was measured using an esophageal Doppler monitoring device before and after fluid infusion (500 ml NaCl 0.9% over 10 min). The variation in aortic blood flow over a respiratory cycle between its minimal and maximal values was calculated. The flow time was also measured.

Measurements and results

Aortic blood flow increased by at least 15% after volume expansion in 20 patients (defined as responders). Before fluid infusion the respiratory variation in aortic flow was higher in responders than in nonresponders (28±12% vs. 12±5%). It significantly decreased after volume expansion (18±11%) in responders only. A respiratory variation in aortic flow before volume expansion of at least 18% predicted fluid responsiveness with a sensitivity of 90% and a specificity of 94%. Flow time increased with fluid infusion in responders and nonresponders. A flow time corrected for heart rate below 277 ms predicted fluid responsiveness with a sensitivity of 55% and a specificity of 94%. The area under the ROC curve generated for variation in aortic blood flow ABF was greater than that generated for flow time.

Conclusions

The respiratory variation in aortic blood flow reliably predicts fluid responsiveness in patients with sinus rhythm and without breathing activity.
Literature
1.
go back to reference Bernardin G, Tiger F, Fouche R, Mattei M (1998) Continuous noninvasive measurement of aortic blood flow in critically ill patients with a new esophageal echo-Doppler system. J Crit Care 13:177–183CrossRefPubMed Bernardin G, Tiger F, Fouche R, Mattei M (1998) Continuous noninvasive measurement of aortic blood flow in critically ill patients with a new esophageal echo-Doppler system. J Crit Care 13:177–183CrossRefPubMed
2.
go back to reference Dark PM, Singer M (2004) The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults. Intensive Care Med 30:2060–2066CrossRefPubMed Dark PM, Singer M (2004) The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults. Intensive Care Med 30:2060–2066CrossRefPubMed
3.
go back to reference Valtier B, Cholley BP, Belot JP, de la Coussaye JE, Mateo J, Payen DM (1998) Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler. Am J Respir Crit Care Med 158:77–83PubMed Valtier B, Cholley BP, Belot JP, de la Coussaye JE, Mateo J, Payen DM (1998) Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler. Am J Respir Crit Care Med 158:77–83PubMed
4.
go back to reference Cariou A, Monchi M, Joly LM, Bellenfant F, Claessens YE, Thebert D, Brunet F, Dhainaut JF (1998) Noninvasive cardiac output monitoring by aortic blood flow determination: evaluation of the Sometec Dynemo-3000 system. Crit Care Med 26:2066–2072CrossRefPubMed Cariou A, Monchi M, Joly LM, Bellenfant F, Claessens YE, Thebert D, Brunet F, Dhainaut JF (1998) Noninvasive cardiac output monitoring by aortic blood flow determination: evaluation of the Sometec Dynemo-3000 system. Crit Care Med 26:2066–2072CrossRefPubMed
5.
go back to reference Roeck M, Jakob SM, Boehlen T, Brander L, Knuesel R, Takala J (2003) Change in stroke volume in response to fluid challenge: assessment using esophageal Doppler. Intensive Care Med 29:1729–1735CrossRefPubMed Roeck M, Jakob SM, Boehlen T, Brander L, Knuesel R, Takala J (2003) Change in stroke volume in response to fluid challenge: assessment using esophageal Doppler. Intensive Care Med 29:1729–1735CrossRefPubMed
6.
go back to reference Singer M, Bennett ED (1991) Noninvasive optimization of left ventricular filling using esophageal Doppler. Crit Care Med 19:1132–1137PubMed Singer M, Bennett ED (1991) Noninvasive optimization of left ventricular filling using esophageal Doppler. Crit Care Med 19:1132–1137PubMed
7.
go back to reference Sinclair S, Singer M (1995) Perioperative haemodynamic monitoring and fluid management-NCEPOD revisited. National Confidential Enquiry into Perioperative Deaths. Br J Hosp Med 53:166–168PubMed Sinclair S, Singer M (1995) Perioperative haemodynamic monitoring and fluid management-NCEPOD revisited. National Confidential Enquiry into Perioperative Deaths. Br J Hosp Med 53:166–168PubMed
8.
go back to reference Michard F, Teboul JL (2002) Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 121:2000–2008CrossRefPubMed Michard F, Teboul JL (2002) Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 121:2000–2008CrossRefPubMed
9.
go back to reference Slama M, Masson H, Teboul JL, Arnould ML, Nait-Kaoudjt R, Colas B, Peltier M, Tribouilloy C, Susic D, Frohlich E, Andrejak M (2004) Monitoring of respiratory variations of aortic blood flow velocity using esophageal Doppler. Intensive Care Med 30:1182–1187PubMed Slama M, Masson H, Teboul JL, Arnould ML, Nait-Kaoudjt R, Colas B, Peltier M, Tribouilloy C, Susic D, Frohlich E, Andrejak M (2004) Monitoring of respiratory variations of aortic blood flow velocity using esophageal Doppler. Intensive Care Med 30:1182–1187PubMed
10.
go back to reference Boulnois JL, Pechoux T (2000) Non-invasive cardiac output monitoring by aortic blood flow measurement with the Dynemo 3000. J Clin Monit Comput 16:127–140CrossRefPubMed Boulnois JL, Pechoux T (2000) Non-invasive cardiac output monitoring by aortic blood flow measurement with the Dynemo 3000. J Clin Monit Comput 16:127–140CrossRefPubMed
11.
go back to reference Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, Richard C, Pinsky MR, Teboul JL (2000) Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 162:134–138PubMed Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, Richard C, Pinsky MR, Teboul JL (2000) Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 162:134–138PubMed
12.
go back to reference Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, Perel A (2001) Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg 92:984–989PubMed Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, Perel A (2001) Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg 92:984–989PubMed
13.
go back to reference Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL (2001) Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 119:867–873CrossRefPubMed Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL (2001) Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 119:867–873CrossRefPubMed
14.
go back to reference Chemla D, Hebert JL, Coirault C, Zamani K, Suard I, Colin P, Lecarpentier Y (1998) Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans. Am J Physiol 274:H500–H505PubMed Chemla D, Hebert JL, Coirault C, Zamani K, Suard I, Colin P, Lecarpentier Y (1998) Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans. Am J Physiol 274:H500–H505PubMed
15.
go back to reference Vieillard-Baron A (2004) Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients. Intensive Care Med 30:2283CrossRef Vieillard-Baron A (2004) Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients. Intensive Care Med 30:2283CrossRef
16.
go back to reference Magder S (2004) Clinical usefulness of respiratory variations in arterial pressure. Am J Respir Crit Care Med 169:151–155CrossRefPubMed Magder S (2004) Clinical usefulness of respiratory variations in arterial pressure. Am J Respir Crit Care Med 169:151–155CrossRefPubMed
Metadata
Title
Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients
Authors
Xavier Monnet
Mario Rienzo
David Osman
Nadia Anguel
Christian Richard
Michael R. Pinsky
Jean-Louis Teboul
Publication date
01-09-2005
Publisher
Springer-Verlag
Published in
Intensive Care Medicine / Issue 9/2005
Print ISSN: 0342-4642
Electronic ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-005-2731-0

Other articles of this Issue 9/2005

Intensive Care Medicine 9/2005 Go to the issue