Skip to main content
Top
Published in: European Journal of Trauma and Emergency Surgery 5/2022

Open Access 11-03-2021 | Bone Defect | Original Article

Plate fixation of the anterior pelvic ring in patients with fragility fractures of the pelvis

Authors: Michiel Herteleer, Mehdi Boudissa, Alexander Hofmann, Daniel Wagner, Pol Maria Rommens

Published in: European Journal of Trauma and Emergency Surgery | Issue 5/2022

Login to get access

Abstract

Introduction

In fragility fractures of the pelvis (FFP), fractures of the posterior pelvic ring are nearly always combined with fractures of the anterior pelvic ring. When a surgical stabilization of the posterior pelvis is performed, a stabilization of the anterior pelvis is recommended as well. In this study, we aim at finding out whether conventional plate osteosynthesis is a valid option in patients with osteoporotic bone.

Materials and methods

We retrospectively reviewed medical charts and radiographs of all patients with a FFP, who underwent a plate osteosynthesis of the anterior pelvic ring between 2009 and 2019. Patient demographics, fracture characteristics, properties of the osteosynthesis, complications and revision surgeries were documented. Single plate osteosynthesis (SPO) at the pelvic brim was compared with double plate osteosynthesis (DPO) with one plate at the pelvic brim and one plate anteriorly. We hypothesized that the number and severity of screw loosening (SL) or plate breakage in DPO are lower than in SPO.

Results

48 patients with a mean age of 76.8 years were reviewed. In 37 cases, SPO was performed, in 11 cases DPO. Eight out of 11 DPO were performed in patients with FFP type III or FFP type IV. We performed significantly more DPO when the instability was located at the level of the pubic symphysis (p = 0.025). More patients with a chronic FFP (surgery more than one month after diagnosis) were treated with DPO (p = 0.07). Infra-acetabular screws were more often inserted in DPO (p = 0.056). Screw loosening (SL) was seen in the superior plate in 45% of patients. There was no SL in the anterior plate. There was SL in 19 of 37 patients with SPO and in 3 of 11 patients with DPO (p = 0.16). SL was localized near to the pubic symphysis in 19 of 22 patients after SPO and in all three patients after DPO. There was no SL in DPO within the first month postoperatively. We performed revision osteosynthesis in six patients (6/48), all belonged to the SPO group (6/37). The presence of a bone defect, unilateral or bilateral anterior pelvic ring fracture, post-operative weight-bearing restrictions, osteosynthesis of the posterior pelvic ring, and the presence of infra- or supra-acetabular screws did not significantly influence screw loosening in SPO or DPO.

Conclusion

There is a high rate of SL in plate fixation of the anterior pelvic ring in FFP. In the vast majority, SL is located near to the pubic symphysis. DPO is associated with a lower rate of SL, less severe SL and a later onset of SL. Revision surgery is less likely in DPO. In FFP, we recommend DPO instead of SPO for fixation of fractures of the anterior pelvic ring, which are located in or near to the pubic symphysis.
Literature
1.
go back to reference Rommens PM, Arand C, Hopf JC, Mehling I, Dietz SO, Wagner D. Progress of instability in fragility fractures of the pelvis: an observational study. Injury. 2019;50:1966–73.CrossRef Rommens PM, Arand C, Hopf JC, Mehling I, Dietz SO, Wagner D. Progress of instability in fragility fractures of the pelvis: an observational study. Injury. 2019;50:1966–73.CrossRef
2.
go back to reference Rommens PM, Graafen M, Arand C, Mehling I, Hofmann A, Wagner D. Minimal-invasive stabilization of anterior pelvic ring fractures with retrograde transpubic screws. Injury. 2020;51:340–6.CrossRef Rommens PM, Graafen M, Arand C, Mehling I, Hofmann A, Wagner D. Minimal-invasive stabilization of anterior pelvic ring fractures with retrograde transpubic screws. Injury. 2020;51:340–6.CrossRef
3.
go back to reference Scheyerer MJ, Osterhoff G, Wehrle S, Wanner GA, Simmen H-P, Werner CML. Detection of posterior pelvic injuries in fractures of the pubic rami. Injury. 2012;43:1326–9.CrossRef Scheyerer MJ, Osterhoff G, Wehrle S, Wanner GA, Simmen H-P, Werner CML. Detection of posterior pelvic injuries in fractures of the pubic rami. Injury. 2012;43:1326–9.CrossRef
4.
go back to reference Rommens PM, Hofmann A. Comprehensive classification of fragility fractures of the pelvic ring: Recommendations for surgical treatment. Injury. 2013;44:1733–44.CrossRef Rommens PM, Hofmann A. Comprehensive classification of fragility fractures of the pelvic ring: Recommendations for surgical treatment. Injury. 2013;44:1733–44.CrossRef
5.
go back to reference Rommens PM, Arand C, Hofmann A, Wagner D. When and how to operate fragility fractures of the pelvis? Indian J Orthop. 2019;53:128–37.CrossRef Rommens PM, Arand C, Hofmann A, Wagner D. When and how to operate fragility fractures of the pelvis? Indian J Orthop. 2019;53:128–37.CrossRef
6.
go back to reference Van Loon P, Kuhn S, Hofmann A, Hessmann MH, Rommens PM. Radiological analysis, operative management and functional outcome of open book pelvic lesions: a 13-year cohort study. Injury. 2011;42:1012–9.CrossRef Van Loon P, Kuhn S, Hofmann A, Hessmann MH, Rommens PM. Radiological analysis, operative management and functional outcome of open book pelvic lesions: a 13-year cohort study. Injury. 2011;42:1012–9.CrossRef
7.
go back to reference Simonian P, Routt ML, Harrington R, Mayo K, Tencer A. Biomechanical simulation of the anteroposterior compression injury of the pelvis: an understanding of instability and fixation. Clin Orthop Relat Res. 1994;309:245–56. Simonian P, Routt ML, Harrington R, Mayo K, Tencer A. Biomechanical simulation of the anteroposterior compression injury of the pelvis: an understanding of instability and fixation. Clin Orthop Relat Res. 1994;309:245–56.
8.
go back to reference Grimshaw CS, Gary Bledsoe J, Moed BR. Locked versus standard unlocked plating of the pubic symphysis: A cadaver biomechanical study. J Orthop Trauma. 2012;26:402–6.CrossRef Grimshaw CS, Gary Bledsoe J, Moed BR. Locked versus standard unlocked plating of the pubic symphysis: A cadaver biomechanical study. J Orthop Trauma. 2012;26:402–6.CrossRef
9.
go back to reference Putnis SE, Pearce R, Wali UJ, Bircher MD, Rickman MS. Open reduction and internal fixation of a traumatic diastasis of the pubic symphysis: One-year radiological and functional outcomes. J Bone Joint Surg Br. 2011;93B:78–84.CrossRef Putnis SE, Pearce R, Wali UJ, Bircher MD, Rickman MS. Open reduction and internal fixation of a traumatic diastasis of the pubic symphysis: One-year radiological and functional outcomes. J Bone Joint Surg Br. 2011;93B:78–84.CrossRef
10.
go back to reference Collinge C, Archdeacon MT, Dulaney-Cripe E, Moed BR. Radiographic changes of implant failure after plating for pubic symphysis diastasis: An underappreciated reality? Trauma. Clin Orthop Relat Res. New York LLC: Springer; 2012. p. 2148–2153. Collinge C, Archdeacon MT, Dulaney-Cripe E, Moed BR. Radiographic changes of implant failure after plating for pubic symphysis diastasis: An underappreciated reality? Trauma. Clin Orthop Relat Res. New York LLC: Springer; 2012. p. 2148–2153.
11.
go back to reference Archdeacon MT, Collinge CA, Schumaier AP, Glogovac G. Effect of Deformity and Malunion of the Anterior Pelvic Ring. J Orthop Trauma. 2018;32:S31–5.CrossRef Archdeacon MT, Collinge CA, Schumaier AP, Glogovac G. Effect of Deformity and Malunion of the Anterior Pelvic Ring. J Orthop Trauma. 2018;32:S31–5.CrossRef
12.
go back to reference Collinge CA, Archdeacon MT, LeBus G. Saddle-horn injury of the pelvis. The injury, its outcomes, and associated male sexual dysfunction. J Bone Joint Surg Am. 2009;91:1630–6.CrossRef Collinge CA, Archdeacon MT, LeBus G. Saddle-horn injury of the pelvis. The injury, its outcomes, and associated male sexual dysfunction. J Bone Joint Surg Am. 2009;91:1630–6.CrossRef
13.
go back to reference Eastman JG, Krieg JC, Routt MLC. Early failure of symphysis pubis plating. Injury. 2016;47:1707–12.CrossRef Eastman JG, Krieg JC, Routt MLC. Early failure of symphysis pubis plating. Injury. 2016;47:1707–12.CrossRef
14.
go back to reference Starr AJ, Nakatani T, Reinert CM, Cederberg K. Superior pubic ramus fractures fixed with percutaneous screws: what predicts fixation failure? J Orthop Trauma. 2008;22:81–7.CrossRef Starr AJ, Nakatani T, Reinert CM, Cederberg K. Superior pubic ramus fractures fixed with percutaneous screws: what predicts fixation failure? J Orthop Trauma. 2008;22:81–7.CrossRef
15.
go back to reference Simonian PT, Routt ML, Harrington RM, Tencer AF. Box plate fixation of the symphysis pubis: biomechanical evaluation of a new technique. J Orthop Trauma. 1994;8:483–9.CrossRef Simonian PT, Routt ML, Harrington RM, Tencer AF. Box plate fixation of the symphysis pubis: biomechanical evaluation of a new technique. J Orthop Trauma. 1994;8:483–9.CrossRef
16.
go back to reference Morris SAC, Loveridge J, Smart DKA, Ward AJ, Chesser TJS. Is fixation failure after plate fixation of the symphysis pubis clinically important? Trauma. Clin Orthop Relat Res. New York LLC: Springer; 2012. p. 2154–2160. Morris SAC, Loveridge J, Smart DKA, Ward AJ, Chesser TJS. Is fixation failure after plate fixation of the symphysis pubis clinically important? Trauma. Clin Orthop Relat Res. New York LLC: Springer; 2012. p. 2154–2160.
17.
go back to reference Culemann U, Marintschev I, Gras F, Pohlemann T. Infra-acetabular corridor-technical tip for an additional screw placement to increase the fixation strength of acetabular fractures. J Trauma; 2011;70:244–246.PubMed Culemann U, Marintschev I, Gras F, Pohlemann T. Infra-acetabular corridor-technical tip for an additional screw placement to increase the fixation strength of acetabular fractures. J Trauma; 2011;70:244–246.PubMed
18.
go back to reference Marintschev I, Gras F, Schwarz CE, Pohlemann T, Hofmann GO, Culemann U. Biomechanical comparison of different acetabular plate systems and constructs - The role of an infra-acetabular screw placement and use of locking plates. Injury. 2012;43:470–4.CrossRef Marintschev I, Gras F, Schwarz CE, Pohlemann T, Hofmann GO, Culemann U. Biomechanical comparison of different acetabular plate systems and constructs - The role of an infra-acetabular screw placement and use of locking plates. Injury. 2012;43:470–4.CrossRef
19.
go back to reference Gänsslen A, Hildebrand F, Kretek C. Supraacetabular external fixation for pain control in geriatric type B pelvic injuries - PubMed. Acta Chir Orthop Traumatol Cech. 2013;80:101–5.PubMed Gänsslen A, Hildebrand F, Kretek C. Supraacetabular external fixation for pain control in geriatric type B pelvic injuries - PubMed. Acta Chir Orthop Traumatol Cech. 2013;80:101–5.PubMed
20.
go back to reference Mason WTM, Khan SN, James CL, Chesser TJS, Ward AJ. Complications of temporary and definitive external fixation of pelvic ring injuries. Injury. 2005;36:599–604.CrossRef Mason WTM, Khan SN, James CL, Chesser TJS, Ward AJ. Complications of temporary and definitive external fixation of pelvic ring injuries. Injury. 2005;36:599–604.CrossRef
21.
go back to reference Vaidya R, Martin AJ, Roth M, Tonnos F, Oliphant B, Carlson J. Midterm Radiographic and Functional Outcomes of the Anterior Subcutaneous Internal Pelvic Fixator (INFIX) for Pelvic Ring Injuries. J Orthop Trauma. Lippincott Williams and Wilkins; 2017. p. 252–259. Vaidya R, Martin AJ, Roth M, Tonnos F, Oliphant B, Carlson J. Midterm Radiographic and Functional Outcomes of the Anterior Subcutaneous Internal Pelvic Fixator (INFIX) for Pelvic Ring Injuries. J Orthop Trauma. Lippincott Williams and Wilkins; 2017. p. 252–259.
22.
go back to reference Acklin YP, Zderic I, Buschbaum J, Varga P, Inzana JA, Grechenig S, et al. Biomechanical comparison of plate and screw fixation in anterior pelvic ring fractures with low bone mineral density. Injury. 2016;47:1456–60.CrossRef Acklin YP, Zderic I, Buschbaum J, Varga P, Inzana JA, Grechenig S, et al. Biomechanical comparison of plate and screw fixation in anterior pelvic ring fractures with low bone mineral density. Injury. 2016;47:1456–60.CrossRef
23.
go back to reference Moed BR, O’Boynick CP, Bledsoe JG. Locked versus standard unlocked plating of the symphysis pubis in a Type-C pelvic injury: a cadaver biomechanical study. Injury. 2014;45:748–51.CrossRef Moed BR, O’Boynick CP, Bledsoe JG. Locked versus standard unlocked plating of the symphysis pubis in a Type-C pelvic injury: a cadaver biomechanical study. Injury. 2014;45:748–51.CrossRef
24.
go back to reference Frietman B, Verbeek J, Biert J, Frölke JP. The effect of implant failure after symphyseal plating on functional outcome and general health. J Orthop Trauma. 2016;30:336–9.PubMed Frietman B, Verbeek J, Biert J, Frölke JP. The effect of implant failure after symphyseal plating on functional outcome and general health. J Orthop Trauma. 2016;30:336–9.PubMed
25.
go back to reference Arand C, Wagner D, Richards RG, Noser H, Kamer L, Sawaguchi T, et al. 3D statistical model of the pelvic ring—a CT-based statistical evaluation of anatomical variation. J Anat. 2019;234:376–83.CrossRef Arand C, Wagner D, Richards RG, Noser H, Kamer L, Sawaguchi T, et al. 3D statistical model of the pelvic ring—a CT-based statistical evaluation of anatomical variation. J Anat. 2019;234:376–83.CrossRef
26.
go back to reference Avilucea FR, Whiting PS, Mir H. Posterior fixation of APC-2 pelvic ring injuries decreases rates of anterior plate failure and malunion. J Bone JtSurg Am. 2016;98:944–51.CrossRef Avilucea FR, Whiting PS, Mir H. Posterior fixation of APC-2 pelvic ring injuries decreases rates of anterior plate failure and malunion. J Bone JtSurg Am. 2016;98:944–51.CrossRef
Metadata
Title
Plate fixation of the anterior pelvic ring in patients with fragility fractures of the pelvis
Authors
Michiel Herteleer
Mehdi Boudissa
Alexander Hofmann
Daniel Wagner
Pol Maria Rommens
Publication date
11-03-2021
Publisher
Springer Berlin Heidelberg
Keyword
Bone Defect
Published in
European Journal of Trauma and Emergency Surgery / Issue 5/2022
Print ISSN: 1863-9933
Electronic ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-021-01625-z

Other articles of this Issue 5/2022

European Journal of Trauma and Emergency Surgery 5/2022 Go to the issue