Adaptive off-line protocol for prostate external radiotherapy with cone beam computer tomography

Authors: M. Piziorska, P. Kukołowicz, A. Zawadzka, M. Pilichowska, P. Pęczkowski, MD

Published in: Strahlentherapie und Onkologie | Issue 11/2012

Login to get access

Abstract

Purpose

The goal of this work was to prepare and to evaluate an off-line adaptive protocol for prostate teleradiotherapy with kilovoltage cone beam computer tomography (CBCT).

Patients and methods

Ten patients with localized prostate carcinoma treated with external beams underwent image-guided radiotherapy. In total, 162 CBCT images were collected. Position of prostate and pubis symphysis (PS) with respect to the isocenter were measured off-line. Using the CBCT scans obtained in the first three fractions the average position of prostate in relation (AvPosPr) to PB was calculated. On each CBCT scan, the position of prostate with respect to AvPosPr was calculated and cumulative histogram of prostate displacement with respect to AvPosPr was prepared. Using this data, the adaptive protocol was prepared in which (1) based on the CBCT made in the first three fractions the AvPosPr to PS is obtained, (2) in all other fractions two orthogonal images are acquired and if for any direction set-up error exceeds 0.2 cm the patient’s position is corrected, and (3) additionally, the patient’s position is corrected if the AvPosPr exceeds 0.2 cm in any direction. To evaluate the adaptive protocol for 30 consecutive patients, the CBCT was also made in 10th and 21st fraction.

Results

For the first 10 patients, the results revealed that the prostate was displaced in relation to AvPosPr >0.7 cm in the vertical and longitudinal directions only on 4 and 5 images of 162 CBCT images, respectively. For the lateral direction, this displacement was >0.3 cm in one case. For the group of 30 patients, displacement was never >0.7, and 0.3 cm for the vertical and lateral directions. In two cases, displacements were >0.7 cm for the longitudinal direction.

Conclusion

Implementation of the proposed adaptive procedure based on the on-line set-up error elimination followed by a reduction of systematic internal error enables reducing the CTV–PTV margin to 0.7, 0.7, and 0.4 cm for the vertical, longitudinal, and lateral directions, respectively.
Appendix
Available only for authorised users
Literature
1.
go back to reference Bel A, Herk M van, Bartelink H, Lebesque JV (1993) A verification procedure to improve patient set-up accuracy using portal imaging. Radiother Oncol 29:253–260PubMedCrossRef Bel A, Herk M van, Bartelink H, Lebesque JV (1993) A verification procedure to improve patient set-up accuracy using portal imaging. Radiother Oncol 29:253–260PubMedCrossRef
2.
go back to reference Beaulieu L, Girouard LM, Aubin S et al (2004) Performing daily prostate targeting with a standard V-EPID and an automated radio-opaque marker detection algorithm. Radiother Oncol 73:61–64PubMedCrossRef Beaulieu L, Girouard LM, Aubin S et al (2004) Performing daily prostate targeting with a standard V-EPID and an automated radio-opaque marker detection algorithm. Radiother Oncol 73:61–64PubMedCrossRef
3.
go back to reference Boer HC de, Heijmen BJ (2001) A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload. Int J Radiat Oncol Biol Phys 50:1350–1365PubMedCrossRef Boer HC de, Heijmen BJ (2001) A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload. Int J Radiat Oncol Biol Phys 50:1350–1365PubMedCrossRef
4.
go back to reference Geier M, Astner ST, Duma MN·et al (2012) Dose-escalated simultaneous integrated-boost treatment of prostate cancer patients via helical tomotherapy. Strahlenther Onkol 188:410–416PubMedCrossRef Geier M, Astner ST, Duma MN·et al (2012) Dose-escalated simultaneous integrated-boost treatment of prostate cancer patients via helical tomotherapy. Strahlenther Onkol 188:410–416PubMedCrossRef
5.
go back to reference Graf R, Bohmer D, Budach V, Wust P (2010) Residual translational and rotational errors after kV X-ray image-guided corrections of prostate location using implanted fiducials. Strahlenther Onkol 10:544–550CrossRef Graf R, Bohmer D, Budach V, Wust P (2010) Residual translational and rotational errors after kV X-ray image-guided corrections of prostate location using implanted fiducials. Strahlenther Onkol 10:544–550CrossRef
6.
go back to reference Hoogeman MS, Herk M van, Bois J de et al (2005) Strategies to reduce the systematic error due to tumor and rectum motion in radiotherapy of prostate cancer. Radiother Oncol 74:177–185PubMedCrossRef Hoogeman MS, Herk M van, Bois J de et al (2005) Strategies to reduce the systematic error due to tumor and rectum motion in radiotherapy of prostate cancer. Radiother Oncol 74:177–185PubMedCrossRef
7.
go back to reference Jaffray D, Siewerdsen JH, Draka DG (2002) Flat-panel cone-beam tomography for image-guided radiation therapy. Int J Radiat Oncol Biol Phys 53:1337–1349PubMedCrossRef Jaffray D, Siewerdsen JH, Draka DG (2002) Flat-panel cone-beam tomography for image-guided radiation therapy. Int J Radiat Oncol Biol Phys 53:1337–1349PubMedCrossRef
8.
go back to reference Kuban DA, Levy LB, Cheung MR et al (2011) Long-term failure patterns and survival in a randomized dose-escalation trial for prostate cancer: who dies of disease? Int J Radiat Oncol Biol Phys 79:1310–1317PubMedCrossRef Kuban DA, Levy LB, Cheung MR et al (2011) Long-term failure patterns and survival in a randomized dose-escalation trial for prostate cancer: who dies of disease? Int J Radiat Oncol Biol Phys 79:1310–1317PubMedCrossRef
9.
go back to reference Looe HK,·Uphoff Y,·Harder D·et al (2012) Numerical deconvolution to enhance sharpness and contrast of portal images for radiotherapy patient positioning verification. Strahlenther Onkol 188:185–190PubMedCrossRef Looe HK,·Uphoff Y,·Harder D·et al (2012) Numerical deconvolution to enhance sharpness and contrast of portal images for radiotherapy patient positioning verification. Strahlenther Onkol 188:185–190PubMedCrossRef
10.
go back to reference Martin JM, Bayley A, Bristow R et al (2009) Image guided dose escalated prostate radiotherapy: still room to improve. Radiat Oncol 4:65CrossRef Martin JM, Bayley A, Bristow R et al (2009) Image guided dose escalated prostate radiotherapy: still room to improve. Radiat Oncol 4:65CrossRef
11.
go back to reference Ma CM, Paskalev K (2006) In-room CT techniques for image-guided radiation therapy. Med Dosim 31:30–39PubMedCrossRef Ma CM, Paskalev K (2006) In-room CT techniques for image-guided radiation therapy. Med Dosim 31:30–39PubMedCrossRef
12.
go back to reference Morin O, Gillis A, Chen J et al (2006) Megavoltage cone-beam CT: system description and applications. Med Dos 31:51–61CrossRef Morin O, Gillis A, Chen J et al (2006) Megavoltage cone-beam CT: system description and applications. Med Dos 31:51–61CrossRef
13.
go back to reference Nijkamp J, Pos FJ, Nuver TT et al (2008) Adaptive radiotherapy for prostate cancer using kilovoltage cone-beam computed tomography: first clinical results. Int J Radiat Oncol Biol Phys 70:75–82PubMedCrossRef Nijkamp J, Pos FJ, Nuver TT et al (2008) Adaptive radiotherapy for prostate cancer using kilovoltage cone-beam computed tomography: first clinical results. Int J Radiat Oncol Biol Phys 70:75–82PubMedCrossRef
14.
go back to reference Nuver TT, Hoogeman MS, Remeijer P et al (2007) An adaptive offline procedure for radiotherapy of prostate cancer. Int J Radiat Oncol Biol Phys 67:1559–1567PubMedCrossRef Nuver TT, Hoogeman MS, Remeijer P et al (2007) An adaptive offline procedure for radiotherapy of prostate cancer. Int J Radiat Oncol Biol Phys 67:1559–1567PubMedCrossRef
15.
go back to reference Rasch C, Steenbakkers R, Van Herk M (2005) Target definition in prostate, head, and neck. Semin Radiat Oncol 15:135–145CrossRef Rasch C, Steenbakkers R, Van Herk M (2005) Target definition in prostate, head, and neck. Semin Radiat Oncol 15:135–145CrossRef
Metadata
Title
Adaptive off-line protocol for prostate external radiotherapy with cone beam computer tomography
Authors
M. Piziorska
P. Kukołowicz
A. Zawadzka
M. Pilichowska
P. Pęczkowski, MD
Publication date
01-11-2012
Publisher
Springer-Verlag
Published in
Strahlentherapie und Onkologie / Issue 11/2012
Print ISSN: 0179-7158
Electronic ISSN: 1439-099X
DOI
https://doi.org/10.1007/s00066-012-0226-9

Other articles of this Issue 11/2012

Strahlentherapie und Onkologie 11/2012 Go to the issue

Mitteilungen der Fachgesellschaften

Mitteilungen