Skip to main content
Top
Published in: European Journal of Medical Research 1/2023

Open Access 01-12-2023 | Laser | Review

Effects of low-level laser therapy on orthodontic miniscrew stability: a systematic review

Authors: De-Hua Zheng, Feng-Chun Hou, Yan-Jun Zang, Bing Li

Published in: European Journal of Medical Research | Issue 1/2023

Login to get access

Abstract

Background

Miniscrews as auxiliary anchorage devices in orthodontic treatment have definite advantages and efficacy. The aim of the present study was to investigate the scientific evidence including randomized controlled trials (RCTs) or controlled clinical trials (CCTs) to support the application of low-level laser therapy to improve miniscrews stability in orthodontic treatment.

Methods

An extensive literature research was conducted with the Cochrane Library, PubMed, EMBASE, Web of Science and ScienceDirect without language limitations. All searches were inclusive until June 2020. The Cochrane Risk of Bias Tool was used to assess the risk of bias (RoB) in the included RCTs.

Results

Through the electronic searches, 428 titles and abstracts were identified. From these, 4 articles were retrieved for review, and 3 of these met the inclusion criteria. Two RCTs reported increased miniscrews stability with low-intensity laser therapy, but the other one reported no difference. Except one study assessed as “high risk of bias” the other two were rated as “low risk of bias”.

Conclusion

There is insufficient evidence to support or refute the effectiveness of LLLT for improvement of miniscrew stability. Further studies with a better study design, reliable evaluation method, comprehensive evaluation intervals and appropriate loading protocol are required to provide more reliable evidence for the clinical application of LLLT.
Literature
1.
go back to reference Sarul M, Minch L, Park HS, Smith JA. Effect of the length of orthodontic mini-screw implants on their long-term stability: a prospective study. Angle Orthod. 2015;85(1):33–8.CrossRef Sarul M, Minch L, Park HS, Smith JA. Effect of the length of orthodontic mini-screw implants on their long-term stability: a prospective study. Angle Orthod. 2015;85(1):33–8.CrossRef
2.
go back to reference Geron S, Shpack N, Kandos S, Davidovitch M. Anchorage loss–a multifactorial response. Angle Orthod. 2003;73(6):730–7. Geron S, Shpack N, Kandos S, Davidovitch M. Anchorage loss–a multifactorial response. Angle Orthod. 2003;73(6):730–7.
3.
go back to reference Mohamed RN, Basha S, Al-Thomali Y. Maxillary molar distalization with miniscrew-supported appliances in Class II malocclusion: a systematic review. Angle Orthod. 2018;88(4):494–502.CrossRef Mohamed RN, Basha S, Al-Thomali Y. Maxillary molar distalization with miniscrew-supported appliances in Class II malocclusion: a systematic review. Angle Orthod. 2018;88(4):494–502.CrossRef
4.
go back to reference Hong RK, Heo JM, Ha YK. Lever-arm and mini-implant system for anterior torque control during retraction in lingual orthodontic treatment. Angle Orthod. 2005;75(1):129. Hong RK, Heo JM, Ha YK. Lever-arm and mini-implant system for anterior torque control during retraction in lingual orthodontic treatment. Angle Orthod. 2005;75(1):129.
5.
go back to reference Kim HK, Park OY, Jee SH. Intrusion of posterior teeth using mini-screw implants. Am J Orthod Dentofac Orthop. 2003;123(6):690–4.CrossRef Kim HK, Park OY, Jee SH. Intrusion of posterior teeth using mini-screw implants. Am J Orthod Dentofac Orthop. 2003;123(6):690–4.CrossRef
6.
go back to reference Jeon YJ, Kim YH, Son WS, Hans MG. Correction of a canted occlusal plane with miniscrews in a patient with facial asymmetry. Am J Orthod Dentofac Orthop. 2006;130:244–52.CrossRef Jeon YJ, Kim YH, Son WS, Hans MG. Correction of a canted occlusal plane with miniscrews in a patient with facial asymmetry. Am J Orthod Dentofac Orthop. 2006;130:244–52.CrossRef
7.
go back to reference Prabhu J, Cousley RRJ. Current products and practice: bone anchorage devices in orthodontics. J Orthod. 2006;33:288–307.CrossRef Prabhu J, Cousley RRJ. Current products and practice: bone anchorage devices in orthodontics. J Orthod. 2006;33:288–307.CrossRef
8.
go back to reference Moon CH, Lee DG, Lee HS, Lim JS. Factors associated with the success rate of orthodontic miniscrews placed in the upper and lower posterior buccal region. Angle Orthod. 2008;78(1):101–6.CrossRef Moon CH, Lee DG, Lee HS, Lim JS. Factors associated with the success rate of orthodontic miniscrews placed in the upper and lower posterior buccal region. Angle Orthod. 2008;78(1):101–6.CrossRef
9.
go back to reference Kravitz ND, Kusnoto B. Risks and complications of orthodontic miniscrews. Am J Orthod Dentofac Orthop. 2007;131:43–51.CrossRef Kravitz ND, Kusnoto B. Risks and complications of orthodontic miniscrews. Am J Orthod Dentofac Orthop. 2007;131:43–51.CrossRef
10.
go back to reference Antoszewska J, Papadopoulos MA, Park HS, Ludwig B. Five-year experience with orthodontic miniscrew implants: a retrospective investigation of factors influencing success rates. Am J Orthod Dentofac Orthop. 2009;136(2):158.e1-10.CrossRef Antoszewska J, Papadopoulos MA, Park HS, Ludwig B. Five-year experience with orthodontic miniscrew implants: a retrospective investigation of factors influencing success rates. Am J Orthod Dentofac Orthop. 2009;136(2):158.e1-10.CrossRef
11.
go back to reference Song YY, Cha JY, Hwang CJ. Mechanical characteristics of various orthodontic mini-screws in relation to artificial cortical bone thickness. Angle Orthod. 2007;77(6):979–85.CrossRef Song YY, Cha JY, Hwang CJ. Mechanical characteristics of various orthodontic mini-screws in relation to artificial cortical bone thickness. Angle Orthod. 2007;77(6):979–85.CrossRef
12.
go back to reference Singh S, Mogra S, Shetty VS, Shetty S, Philip P. Three-dimensional finite element analysis of strength, stability, and stress distribution in orthodontic anchorage: a conical, self-drilling miniscrew implant system. Am J Orthod Dentofac Orthop. 2012;141:327–36.CrossRef Singh S, Mogra S, Shetty VS, Shetty S, Philip P. Three-dimensional finite element analysis of strength, stability, and stress distribution in orthodontic anchorage: a conical, self-drilling miniscrew implant system. Am J Orthod Dentofac Orthop. 2012;141:327–36.CrossRef
13.
go back to reference Sun G, Tunér J. Low-level laser therapy in dentistry. Dent Clin North Am. 2004;48:0–1076.CrossRef Sun G, Tunér J. Low-level laser therapy in dentistry. Dent Clin North Am. 2004;48:0–1076.CrossRef
14.
go back to reference Qamruddin I, Alam MK, Mahroof V, Khamis MF, Husein A. Effects of low-level laser irradiation on the rate of orthodontic tooth movement and associated pain with self-ligating brackets. Am J Orthod Dentofac Orthop. 2017;152(5):622–30.CrossRef Qamruddin I, Alam MK, Mahroof V, Khamis MF, Husein A. Effects of low-level laser irradiation on the rate of orthodontic tooth movement and associated pain with self-ligating brackets. Am J Orthod Dentofac Orthop. 2017;152(5):622–30.CrossRef
15.
go back to reference Kim WT, Bayome M, Park JB, Park JH, Baek SH, Kook YA. Effect of frequent laser irradiation on orthodontic pain. Angle Orthod. 2013;83(4):611–6.CrossRef Kim WT, Bayome M, Park JB, Park JH, Baek SH, Kook YA. Effect of frequent laser irradiation on orthodontic pain. Angle Orthod. 2013;83(4):611–6.CrossRef
16.
go back to reference Doshi-Mehta G, Bhad-Patil WA. Efficacy of low-intensity laser therapy in reducing treatment time and orthodontic pain: a clinical investigation. Am J Orthod Dentofac Orthop. 2012;141:289–97.CrossRef Doshi-Mehta G, Bhad-Patil WA. Efficacy of low-intensity laser therapy in reducing treatment time and orthodontic pain: a clinical investigation. Am J Orthod Dentofac Orthop. 2012;141:289–97.CrossRef
17.
go back to reference Sonesson M, De Geer E, Subraian J, Petrén S. Efficacy of low-level laser therapy in accelerating tooth movement, preventing relapse and managing acute pain during orthodontic treatment in humans: a systematic review. BMC Oral Health. 2017;17(1):11.CrossRef Sonesson M, De Geer E, Subraian J, Petrén S. Efficacy of low-level laser therapy in accelerating tooth movement, preventing relapse and managing acute pain during orthodontic treatment in humans: a systematic review. BMC Oral Health. 2017;17(1):11.CrossRef
18.
go back to reference Abi-Ramia LBP, Sasso Stuani A, Sasso Stuani A, Sasso Stuani MB, Alvaro DMM. Effects of low-level laser therapy and orthodontic tooth movement on dental pulps in rats. Angle Orthod. 2010;80(1):116–22.CrossRef Abi-Ramia LBP, Sasso Stuani A, Sasso Stuani A, Sasso Stuani MB, Alvaro DMM. Effects of low-level laser therapy and orthodontic tooth movement on dental pulps in rats. Angle Orthod. 2010;80(1):116–22.CrossRef
19.
go back to reference Kawasaki K, Shimizu N. Effects of low-energy laser irradiation on bone remodeling during experimental tooth movement in rats. Lasers Surg Med. 2000;26:282–91.CrossRef Kawasaki K, Shimizu N. Effects of low-energy laser irradiation on bone remodeling during experimental tooth movement in rats. Lasers Surg Med. 2000;26:282–91.CrossRef
20.
go back to reference Mizutani K, Musya Y, Wakae K, Kobayashi T, Tobe M, Taira K. A clinical study on serum prostaglandin E2 with low-level laser therapy. Photomed Laser Surg. 2004;22(6):537–9.CrossRef Mizutani K, Musya Y, Wakae K, Kobayashi T, Tobe M, Taira K. A clinical study on serum prostaglandin E2 with low-level laser therapy. Photomed Laser Surg. 2004;22(6):537–9.CrossRef
21.
go back to reference Osman A, Abdel Moneim A, El Harouni N, Shokry M. Long-term evaluation of the effect of low-level laser therapy on orthodontic miniscrew stability and peri-implant gingival condition: a randomized clinical trial. J World Fed Orthod. 2017;6(3):109–14. Osman A, Abdel Moneim A, El Harouni N, Shokry M. Long-term evaluation of the effect of low-level laser therapy on orthodontic miniscrew stability and peri-implant gingival condition: a randomized clinical trial. J World Fed Orthod. 2017;6(3):109–14.
22.
go back to reference Abohabib AM, Mohamed M, FayedLabib AH. Effects of low-intensity laser therapy on the stability of orthodontic mini-implants: a randomised controlled clinical trial. J Orthod. 2018;45:149–56.CrossRef Abohabib AM, Mohamed M, FayedLabib AH. Effects of low-intensity laser therapy on the stability of orthodontic mini-implants: a randomised controlled clinical trial. J Orthod. 2018;45:149–56.CrossRef
23.
go back to reference Ekizer A, Turker G, Uysal T, Guray E, Zekeriya Tasdemir S. Light emitting diode mediated photobiomodulation therapy improves orthodontic tooth movement and miniscrew stability: a randomized controlled clinical trial. Lasers Surg Med. 2016;48:936–43.CrossRef Ekizer A, Turker G, Uysal T, Guray E, Zekeriya Tasdemir S. Light emitting diode mediated photobiomodulation therapy improves orthodontic tooth movement and miniscrew stability: a randomized controlled clinical trial. Lasers Surg Med. 2016;48:936–43.CrossRef
24.
go back to reference Higgins JPT, Green S. Cochrane handbook for systematic reviews of interventions. London: The Cochrane Collaboration; 2011. Higgins JPT, Green S. Cochrane handbook for systematic reviews of interventions. London: The Cochrane Collaboration; 2011.
25.
go back to reference Pinto MR, dos Santos RL, Pithon MM, de Souza Araújo MT, Braga JPV, Nojima LI. Influence of low-intensity laser therapy on the stability of orthodontic mini-implants: a study in rabbits. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013;115(2):26–30.CrossRef Pinto MR, dos Santos RL, Pithon MM, de Souza Araújo MT, Braga JPV, Nojima LI. Influence of low-intensity laser therapy on the stability of orthodontic mini-implants: a study in rabbits. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013;115(2):26–30.CrossRef
26.
go back to reference Goymen M, Isman E, Taner L, Kurkcu M. Histomorphometric evaluation of the effects of various diode lasers and force levels on orthodontic mini screw stability. Photomed Laser Surg. 2015;33(1):29–34.CrossRef Goymen M, Isman E, Taner L, Kurkcu M. Histomorphometric evaluation of the effects of various diode lasers and force levels on orthodontic mini screw stability. Photomed Laser Surg. 2015;33(1):29–34.CrossRef
27.
go back to reference Zix J, Hug S, Kessler-Liechti G, Mericske-Stern R. Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: comparison of both techniques in a clinical trial. Int J Oral Maxillofac Implants. 2008;23:525–30. Zix J, Hug S, Kessler-Liechti G, Mericske-Stern R. Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: comparison of both techniques in a clinical trial. Int J Oral Maxillofac Implants. 2008;23:525–30.
28.
go back to reference Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res. 1997;8:226–33.CrossRef Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res. 1997;8:226–33.CrossRef
29.
go back to reference Tricio J, van Steenberghe D, Rosenberg D, DuchateauL,. Implant stability related to insertion torque force and bone density: an in vitro study. J Prosthet Dent. 1995;74:608–12.CrossRef Tricio J, van Steenberghe D, Rosenberg D, DuchateauL,. Implant stability related to insertion torque force and bone density: an in vitro study. J Prosthet Dent. 1995;74:608–12.CrossRef
30.
go back to reference Meredith N, Friberg B, Sennerby L, Aparicio C. Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability. Int J Prosthodont. 1998;11:269–75. Meredith N, Friberg B, Sennerby L, Aparicio C. Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability. Int J Prosthodont. 1998;11:269–75.
31.
go back to reference Ure DS, Oliver DR, Kim KB, Melo AC, Buschang PH. Stability changes of miniscrew implants over time: a pilot resonance frequency analysis. Angle Orthod. 2011;81(6):994–1000.CrossRef Ure DS, Oliver DR, Kim KB, Melo AC, Buschang PH. Stability changes of miniscrew implants over time: a pilot resonance frequency analysis. Angle Orthod. 2011;81(6):994–1000.CrossRef
32.
go back to reference Nienkemper M, Wilmes B, Panayotidis A, Pauls A, Golubovic V, Schwarz F. Measurement of mini-implantstability using resonance frequency analysis. Angle Orthod. 2013;83(2):230–8.CrossRef Nienkemper M, Wilmes B, Panayotidis A, Pauls A, Golubovic V, Schwarz F. Measurement of mini-implantstability using resonance frequency analysis. Angle Orthod. 2013;83(2):230–8.CrossRef
33.
go back to reference Pan CY, Chou ST, Tseng YC, Yang YH, Wu CY, Lan TH. Influence of different implant materials on the primary stability of orthodontic mini-implants. Kaohsiung J Med Sci. 2012;28:673–8.CrossRef Pan CY, Chou ST, Tseng YC, Yang YH, Wu CY, Lan TH. Influence of different implant materials on the primary stability of orthodontic mini-implants. Kaohsiung J Med Sci. 2012;28:673–8.CrossRef
34.
go back to reference Andreotti AM, Goiato MC, Nobrega AS, Pellizzer EP. Relationship between implant stability measurements obtained by two different devices: a systematic review. J Periodontol. 2017;88(3):281–8.CrossRef Andreotti AM, Goiato MC, Nobrega AS, Pellizzer EP. Relationship between implant stability measurements obtained by two different devices: a systematic review. J Periodontol. 2017;88(3):281–8.CrossRef
35.
go back to reference Carney LO, Campbell PM, Spears R, Ceen RF, Melo AC, Buschang PH. Effects of pilot holes on longitudinal miniscrew stability and bony adaptation. Am J Orthod Dentofac Orthop. 2014;146:554–64.CrossRef Carney LO, Campbell PM, Spears R, Ceen RF, Melo AC, Buschang PH. Effects of pilot holes on longitudinal miniscrew stability and bony adaptation. Am J Orthod Dentofac Orthop. 2014;146:554–64.CrossRef
36.
go back to reference Turkoz C, Atac MS, Tuncer C, Balos Tuncer B, Kaan E. The effect of drill-free and drilling methods on the stability of mini-implants under early orthodontic loading in adolescent patients. Eur J Orthod. 2011;33(5):533–6.CrossRef Turkoz C, Atac MS, Tuncer C, Balos Tuncer B, Kaan E. The effect of drill-free and drilling methods on the stability of mini-implants under early orthodontic loading in adolescent patients. Eur J Orthod. 2011;33(5):533–6.CrossRef
37.
go back to reference Łyczek J, Antoszewskasmith J. Fundamental factors related to orthodontic micro-implant stability: review of the literature. Dent Med Probl. 2017;54(2):189–93.CrossRef Łyczek J, Antoszewskasmith J. Fundamental factors related to orthodontic micro-implant stability: review of the literature. Dent Med Probl. 2017;54(2):189–93.CrossRef
Metadata
Title
Effects of low-level laser therapy on orthodontic miniscrew stability: a systematic review
Authors
De-Hua Zheng
Feng-Chun Hou
Yan-Jun Zang
Bing Li
Publication date
01-12-2023
Publisher
BioMed Central
Keyword
Laser
Published in
European Journal of Medical Research / Issue 1/2023
Electronic ISSN: 2047-783X
DOI
https://doi.org/10.1186/s40001-023-01010-z

Other articles of this Issue 1/2023

European Journal of Medical Research 1/2023 Go to the issue