Skip to main content
Top
Published in: Surgical Endoscopy 11/2003

01-11-2003 | Original article

Laparoscopic inguinal hernia repair using an anatomically contoured three-dimensional mesh

Authors: R. C. W. Bell, J. G. Price

Published in: Surgical Endoscopy | Issue 11/2003

Login to get access

Abstract

Background: Laparoscopic inguinal hernia repair frequently is performed with mechanical fixation of a flat polypropylene mesh. Mechanical fixation is associated with pain syndromes, and mesh migration may occur without fixation of flat prostheses. An anatomically contoured mesh (3D Max; Davol, Cranston, RI, USA) using no or minimal fixation would avoid these problems. Methods: A retrospective case study reviewed 212 transabdominal preperitoneal herniaplasties with 11 × 16-cm 3D Max mesh in 146 patients. Fixation with three helical tacks at the most was used early or with very large defects. Results: Fixation was used in 19% of the cases, but only for 1 of the last 98 patients. As reported, 94% of the patients returned to normal activities by 3 weeks, 97% returned to unrestricted sports by 6 weeks, and 92% complete recovery from surgery by 9 weeks. Fixation or bilateral repair did not alter recovery. Four patients had minor pain or numbness. Symptomatic recurrence was 0%. One asymptomatic indirect recurrence was noted on examination, during a mean follow-up period of 23 months, yielding a 0.55% hernia rate and a 0.42% patient-year recurrence risk. Conclusions: An anatomically contoured mesh for transabdominal preperitoneal hernia repair often requires no fixation, with minimal risk of neuropathy and less than a 0.5% patient-year recurrence rate. Recovery is excellent even with bilateral repair or some fixation.
Literature
2.
go back to reference Felix, E, Scott, S, Crafton, P, et al. 1998Causes of recurrence after laparoscopic hernioplasty.Surg Endosc12226231 Felix, E, Scott, S, Crafton, P,  et al. 1998Causes of recurrence after laparoscopic hernioplasty.Surg Endosc12226231
3.
go back to reference Jago, R 2001Stapled and nonstapled laparoscopic transabdominal preperitoneal inguinal hernia repair.Surg Endosc15766776CrossRefPubMed Jago, R 2001Stapled and nonstapled laparoscopic transabdominal preperitoneal inguinal hernia repair.Surg Endosc15766776CrossRefPubMed
4.
go back to reference Khajanchee, YS, Urbach, DR, Swanstrom, LL, Hansen, PD 2001Outcomes of laparoscopic herniorrhaphy without fixation of mesh to the abdominal wall.Surg Endosc1511021107 Khajanchee, YS, Urbach, DR, Swanstrom, LL, Hansen, PD 2001Outcomes of laparoscopic herniorrhaphy without fixation of mesh to the abdominal wall.Surg Endosc1511021107
5.
go back to reference Knook, MT, Weidema, WF, Stassen, LP, van Steensel, CJ 1999Endoscopic total extraperitoneal repair of primary and recurrent inguinal hernias.Surg Endosc13507511CrossRefPubMed Knook, MT, Weidema, WF, Stassen, LP, van Steensel, CJ 1999Endoscopic total extraperitoneal repair of primary and recurrent inguinal hernias.Surg Endosc13507511CrossRefPubMed
6.
go back to reference Liem, MS, van der Graaf, Y, van Steensel, CJ, et al. 1997Comparison of conventional anterior surgery and laparoscopic surgery for inguinal hernia repair.N Engl J Med33615411547PubMed Liem, MS, van der Graaf, Y, van Steensel, CJ,  et al. 1997Comparison of conventional anterior surgery and laparoscopic surgery for inguinal hernia repair.N Engl J Med33615411547PubMed
7.
go back to reference Liem, MS, van der Graaf, Y, Zwart, RC, Geurts, I, van Vroonhoven, TJ 1997A randomized comparison of physical performance following laparoscopic and open inguinal hernia repair. The Coala Trial Group.Br J Surg846476PubMed Liem, MS, van der Graaf, Y, Zwart, RC, Geurts, I, van Vroonhoven, TJ 1997A randomized comparison of physical performance following laparoscopic and open inguinal hernia repair. The Coala Trial Group.Br J Surg846476PubMed
8.
go back to reference Pajotin, P 1998Laparoscopic groin hernia repair using a curved prosthesis without fixation.Le journal de Coelio-Chirurgie286468 Pajotin, P 1998Laparoscopic groin hernia repair using a curved prosthesis without fixation.Le journal de Coelio-Chirurgie286468
9.
go back to reference Quilici, PJ, Greaney, EM, Quilici, J, Anderson, S 2000Laparoscopic inguinal hernia repair: optimal technical variations and results in 1,700 cases.Am Surg66848852PubMed Quilici, PJ, Greaney, EM, Quilici, J, Anderson, S 2000Laparoscopic inguinal hernia repair: optimal technical variations and results in 1,700 cases.Am Surg66848852PubMed
10.
go back to reference Smith, AI, Royston, CM, Sedman, PC 1999Stapled and nonstapled laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair: a prospective randomized trial.Surg Endosc13804806CrossRefPubMed Smith, AI, Royston, CM, Sedman, PC 1999Stapled and nonstapled laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair: a prospective randomized trial.Surg Endosc13804806CrossRefPubMed
11.
go back to reference Stark, E, Oestreich, K, Wendl, K, Rumstadt, B, Hagmuller, E 1999Nerve irritation after laparoscopic hernia repair.Surg Endosc13878881PubMed Stark, E, Oestreich, K, Wendl, K, Rumstadt, B, Hagmuller, E 1999Nerve irritation after laparoscopic hernia repair.Surg Endosc13878881PubMed
Metadata
Title
Laparoscopic inguinal hernia repair using an anatomically contoured three-dimensional mesh
Authors
R. C. W. Bell
J. G. Price
Publication date
01-11-2003
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 11/2003
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-002-8763-4

Other articles of this Issue 11/2003

Surgical Endoscopy 11/2003 Go to the issue

News and notices

News and notices

Letter to the editor

The author replies