Skip to main content
Top
Published in: European Spine Journal 3/2013

01-05-2013 | Case Report

L5 spinal nerve injury caused by misplacement of outwardly-inserted S1 pedicle screws

Authors: Masahiro Inoue, Gen Inoue, Tomoyuki Ozawa, Masayuki Miyagi, Hiroto Kamoda, Tetsuhiro Ishikawa, Miyako Suzuki, Yoshihiro Sakuma, Yasuhiro Oikawa, Kazuyo Yamauchi, Sumihisa Orita, Masashi Takaso, Tomoaki Toyone, Kazuhisa Takahashi, Seiji Ohtori

Published in: European Spine Journal | Special Issue 3/2013

Login to get access

Abstract

Purpose

To evaluate L5 nerve root injuries caused by outwardly misplaced S1 pedicle screws.

Summary of Background Data

Pedicle screws remain the criterion standard for fixation of L5–S1 to correct lumbosacral instability. When inserting S1 pedicle screws, it is possible to injure the L5 nerve root if screws are inserted outwardly and the tip of the screw perforates the anterior cortex of the sacrum. Despite this risk, to our knowledge this type of injury has never been reported as a case series.

Methods

We experienced 2 cases of L5 nerve root injury caused by outwardly-inserted S1 pedicle screws. In both cases, bilateral S1 pedicle screws were inserted outwardly using a free-hand technique, and on one side, screws induced severe pain by impinging on an L5 root. Computed tomography after the selective rootgraphy of the injured nerve showed the nerve compressed laterally by screw threads in Case 1 and crushed between the screw threads and the sacral body in Case 2.

Results

In both cases, leg pain disappeared immediately after the infiltration of the nerve with lidocaine, but symptoms recurred within a few days in Case 1 and within an hour in Case 2. Conservative treatment of three spinal nerve infiltrations was effective in Case 1, but reinsertion of the rogue screw was necessary in Case 2.

Conclusions

Surgeons should recognize that lateral inclination of S1 pedicle screws can cause L5 nerve root injury, which may require reinsertion of the screw, especially in cases where insertion is difficult because of overlapping surrounding muscle or bony tissue.
Literature
1.
go back to reference Bridwell KH, Sedgewick TA, O’Brien MF, Lenke LG, Baldus C (1993) The role of fusion and instrumentation in the treatment of degenerative spondylolisthesis with spinal stenosis. J Spinal Disord 6:461–472PubMedCrossRef Bridwell KH, Sedgewick TA, O’Brien MF, Lenke LG, Baldus C (1993) The role of fusion and instrumentation in the treatment of degenerative spondylolisthesis with spinal stenosis. J Spinal Disord 6:461–472PubMedCrossRef
2.
go back to reference Mardjetko SM, Connolly PJ, Shott S (1994) Degenerative lumbar spondylolisthesis: a meta-analysis of literature 1970–1993. Spine 19(Suppl):2256–2265CrossRef Mardjetko SM, Connolly PJ, Shott S (1994) Degenerative lumbar spondylolisthesis: a meta-analysis of literature 1970–1993. Spine 19(Suppl):2256–2265CrossRef
3.
go back to reference Yuan HA, Garfin SR, Dickman CA, Mardjetko SM (1994) A historical cohort study of pedicle screw fixation in thoracic, lumbar, and sacral spinal fusions. Spine 19(Suppl):2279–2296CrossRef Yuan HA, Garfin SR, Dickman CA, Mardjetko SM (1994) A historical cohort study of pedicle screw fixation in thoracic, lumbar, and sacral spinal fusions. Spine 19(Suppl):2279–2296CrossRef
4.
go back to reference Christensen FB (2004) Lumbar spinal fusion. Outcome in relation to surgical methods, choice of implant and postoperative rehabilitation. Acta Orthop Scand Suppl 75:2–43PubMedCrossRef Christensen FB (2004) Lumbar spinal fusion. Outcome in relation to surgical methods, choice of implant and postoperative rehabilitation. Acta Orthop Scand Suppl 75:2–43PubMedCrossRef
5.
go back to reference Ledonio CG, Polly DW Jr, Vitale MG, Wang Q, Richards BS (2011) Pediatric pedicle screws: comparative effectiveness and safety: a systematic literature review from the Scoliosis Research Society and the Pediatric Orthopaedic Society of North America task force. J Bone Joint Surg Am 93:1227–1234PubMedCrossRef Ledonio CG, Polly DW Jr, Vitale MG, Wang Q, Richards BS (2011) Pediatric pedicle screws: comparative effectiveness and safety: a systematic literature review from the Scoliosis Research Society and the Pediatric Orthopaedic Society of North America task force. J Bone Joint Surg Am 93:1227–1234PubMedCrossRef
6.
go back to reference Robertson PA, Plank LD (2008) Prospective cohort analysis of disability reduction with lumbar spinal fusion surgery in community practice. J Spinal Disord Tech 21:235–240PubMedCrossRef Robertson PA, Plank LD (2008) Prospective cohort analysis of disability reduction with lumbar spinal fusion surgery in community practice. J Spinal Disord Tech 21:235–240PubMedCrossRef
7.
go back to reference Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81:1519–1528PubMed Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81:1519–1528PubMed
8.
go back to reference Okuda S, Miyauchi A, Oda T, Haku T, Yamamoto T, Iwasaki M (2006) Surgical complications of posterior lumbar interbody fusion with total facetectomy in 251 patients. J Neurosurg Spine 4:304–309PubMedCrossRef Okuda S, Miyauchi A, Oda T, Haku T, Yamamoto T, Iwasaki M (2006) Surgical complications of posterior lumbar interbody fusion with total facetectomy in 251 patients. J Neurosurg Spine 4:304–309PubMedCrossRef
9.
go back to reference Rivet DJ, Jeck D, Brennan J, Epstein A, Lauryssen C (2004) Clinical outcomes and complications associated with pedicle screw fixation-augmented lumbar interbody fusion. J Neurosurg Spine 1:261–266PubMedCrossRef Rivet DJ, Jeck D, Brennan J, Epstein A, Lauryssen C (2004) Clinical outcomes and complications associated with pedicle screw fixation-augmented lumbar interbody fusion. J Neurosurg Spine 1:261–266PubMedCrossRef
10.
go back to reference Kosmopoulos V, Schizas C (2007) Pedicle screw placement accuracy: a meta-analysis. Spine 32:E111–E120PubMedCrossRef Kosmopoulos V, Schizas C (2007) Pedicle screw placement accuracy: a meta-analysis. Spine 32:E111–E120PubMedCrossRef
11.
go back to reference Gelalis ID, Paschos NK, Pakos EE, Politis AN, Arnaoutoglou CM, Karageorgos AC, Ploumis A, Xenakis TA (2012) Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J 21:247–255PubMedCrossRef Gelalis ID, Paschos NK, Pakos EE, Politis AN, Arnaoutoglou CM, Karageorgos AC, Ploumis A, Xenakis TA (2012) Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J 21:247–255PubMedCrossRef
12.
go back to reference Jacobs WC, Vreeling A, De Kleuver M (2006) Fusion for low-grade adult isthmic spondylolisthesis: a systematic review of the literature. Eur Spine J 15:391–402PubMedCrossRef Jacobs WC, Vreeling A, De Kleuver M (2006) Fusion for low-grade adult isthmic spondylolisthesis: a systematic review of the literature. Eur Spine J 15:391–402PubMedCrossRef
13.
go back to reference Zhou ZJ, Zhao FD, Fang XQ, Zhao X, Fan SW (2011) Meta-analysis of instrumented posterior interbody fusion versus instrumented posterolateral fusion in the lumbar spine. J Neurosurg Spine 15:295–310PubMedCrossRef Zhou ZJ, Zhao FD, Fang XQ, Zhao X, Fan SW (2011) Meta-analysis of instrumented posterior interbody fusion versus instrumented posterolateral fusion in the lumbar spine. J Neurosurg Spine 15:295–310PubMedCrossRef
14.
go back to reference Schwab FJ, Nazarian DG, Mahmud F, Michelsen CB (1995) Effects of spinal instrumentation on fusion of the lumbosacral spine. Spine 20:2023–2028PubMedCrossRef Schwab FJ, Nazarian DG, Mahmud F, Michelsen CB (1995) Effects of spinal instrumentation on fusion of the lumbosacral spine. Spine 20:2023–2028PubMedCrossRef
15.
go back to reference McCord DH, Cunningham BW, Shono Y, Myers JJ, McAfee PC (1992) Biomechanical analysis of lumbosacral fixation. Spine 17:S235–S243PubMedCrossRef McCord DH, Cunningham BW, Shono Y, Myers JJ, McAfee PC (1992) Biomechanical analysis of lumbosacral fixation. Spine 17:S235–S243PubMedCrossRef
16.
go back to reference von Strempel A, Trenkmann S, Krönauer I, Kirsch L, Sukopp C (1998) The stability of bone screws in the os sacrum. Eur Spine J 7:313–320CrossRef von Strempel A, Trenkmann S, Krönauer I, Kirsch L, Sukopp C (1998) The stability of bone screws in the os sacrum. Eur Spine J 7:313–320CrossRef
17.
go back to reference Lehman RA Jr, Kuklo TR, Belmont PJ Jr, Andersen RC, Polly DW Jr (2002) Advantage of pedicle screw fixation directed into the apex of the sacral promontory over bicortical fixation: a biomechanical analysis. Spine 27:806–811PubMedCrossRef Lehman RA Jr, Kuklo TR, Belmont PJ Jr, Andersen RC, Polly DW Jr (2002) Advantage of pedicle screw fixation directed into the apex of the sacral promontory over bicortical fixation: a biomechanical analysis. Spine 27:806–811PubMedCrossRef
18.
go back to reference Orita S, Ohtori S, Eguchi Y, Kamoda H, Arai G, Ishikawa T, Miyagi M, Inoue G, Ochiai N, Kishida S, Takaso M, Aoki Y, Takahashi K (2010) Radiographic evaluation of monocortical versus tricortical purchase approaches in lumbosacral fixation with sacral pedicle screws: a prospective study of ninety consecutive patients. Spine 35:E1230–E1237PubMedCrossRef Orita S, Ohtori S, Eguchi Y, Kamoda H, Arai G, Ishikawa T, Miyagi M, Inoue G, Ochiai N, Kishida S, Takaso M, Aoki Y, Takahashi K (2010) Radiographic evaluation of monocortical versus tricortical purchase approaches in lumbosacral fixation with sacral pedicle screws: a prospective study of ninety consecutive patients. Spine 35:E1230–E1237PubMedCrossRef
19.
go back to reference Ergur I, Akcali O, Kiray A, Kosay C, Tayefi H (2007) The role of fusion and instrumentation in the treatment of degenerative spondylolisthesis with spinal stenosis. Eur Spine J 16:1519–1523PubMedCrossRef Ergur I, Akcali O, Kiray A, Kosay C, Tayefi H (2007) The role of fusion and instrumentation in the treatment of degenerative spondylolisthesis with spinal stenosis. Eur Spine J 16:1519–1523PubMedCrossRef
20.
go back to reference Esses SI, Botsford DJ, Huler RJ, Rauschning W (1991) Surgical anatomy of the sacrum: a guide for rational screw fixation. Spine 16:S283–S288PubMedCrossRef Esses SI, Botsford DJ, Huler RJ, Rauschning W (1991) Surgical anatomy of the sacrum: a guide for rational screw fixation. Spine 16:S283–S288PubMedCrossRef
21.
go back to reference Licht NJ, Rowe DE, Ross LM (1992) Pitfalls of pedicle screw fixation in the sacrum. Spine 17:892–896PubMedCrossRef Licht NJ, Rowe DE, Ross LM (1992) Pitfalls of pedicle screw fixation in the sacrum. Spine 17:892–896PubMedCrossRef
22.
go back to reference Mirkovic S, Abitbol JJ, Steinman J, Edwards CC, Schaffler M, Massie J, Garfin SR (1991) Anatomic consideration for sacral screw placement. Spine 16:S289–S294PubMedCrossRef Mirkovic S, Abitbol JJ, Steinman J, Edwards CC, Schaffler M, Massie J, Garfin SR (1991) Anatomic consideration for sacral screw placement. Spine 16:S289–S294PubMedCrossRef
23.
go back to reference Morse BJ, Ebraheim NA, Jackson WT (1994) Preoperative CT determination of angles for sacral screw placement. Spine 19:604–607PubMedCrossRef Morse BJ, Ebraheim NA, Jackson WT (1994) Preoperative CT determination of angles for sacral screw placement. Spine 19:604–607PubMedCrossRef
24.
go back to reference Xu R, Ebraheim NA, Yeasting RA, Wong FY, Jackson WT (1995) Morphometric evaluation of the first sacral vertebra and the projection of its pedicle on the posterior aspect of the sacrum. Spine 20:936–940PubMedCrossRef Xu R, Ebraheim NA, Yeasting RA, Wong FY, Jackson WT (1995) Morphometric evaluation of the first sacral vertebra and the projection of its pedicle on the posterior aspect of the sacrum. Spine 20:936–940PubMedCrossRef
25.
go back to reference Smith SA, Abitbol JJ, Carlson GD, Anderson DR, Taggart KW, Garfin SR (1993) The effects of depth of penetration, screw orientation, and bone density on sacral screw fixation. Spine 18:1006–1010PubMedCrossRef Smith SA, Abitbol JJ, Carlson GD, Anderson DR, Taggart KW, Garfin SR (1993) The effects of depth of penetration, screw orientation, and bone density on sacral screw fixation. Spine 18:1006–1010PubMedCrossRef
26.
go back to reference Zheng Y, Lu WW, Zhu Q, Qin L, Zhong S, Leong JC (2000) Variation in bone mineral density of the sacrum in young adults and its significance for sacral fixation. Spine 25:353–357PubMedCrossRef Zheng Y, Lu WW, Zhu Q, Qin L, Zhong S, Leong JC (2000) Variation in bone mineral density of the sacrum in young adults and its significance for sacral fixation. Spine 25:353–357PubMedCrossRef
27.
go back to reference Arman C, Naderi S, Kiray A, Aksu FT, Yilmaz HS, Tetik S, Korman E (2009) The human sacrum and safe approaches for screw placement. J Clin Neurosci 16:1046–1049PubMedCrossRef Arman C, Naderi S, Kiray A, Aksu FT, Yilmaz HS, Tetik S, Korman E (2009) The human sacrum and safe approaches for screw placement. J Clin Neurosci 16:1046–1049PubMedCrossRef
28.
go back to reference Okutan O, Kaptanoglu E, Solaroglu I, Beskonakli E, Tekdemir I (2004) Determination of the length of anteromedial screw trajectory by measuring interforaminal distance in the first sacral vertebra. Spine 29:1608–1611PubMedCrossRef Okutan O, Kaptanoglu E, Solaroglu I, Beskonakli E, Tekdemir I (2004) Determination of the length of anteromedial screw trajectory by measuring interforaminal distance in the first sacral vertebra. Spine 29:1608–1611PubMedCrossRef
29.
go back to reference Robertson PA, Stewart NR (2000) The radiologic anatomy of the lumbar and lumbosacral pedicles. Spine 25:709–715PubMedCrossRef Robertson PA, Stewart NR (2000) The radiologic anatomy of the lumbar and lumbosacral pedicles. Spine 25:709–715PubMedCrossRef
30.
go back to reference de Peretti F, Argenson C, Bourgeon A, Omar F, Eude P, Aboulker C (1991) Anatomic and experimental basis for the insertion of a screw at the first sacral vertebra. Surg Radiol Anat 13:133–137PubMedCrossRef de Peretti F, Argenson C, Bourgeon A, Omar F, Eude P, Aboulker C (1991) Anatomic and experimental basis for the insertion of a screw at the first sacral vertebra. Surg Radiol Anat 13:133–137PubMedCrossRef
31.
go back to reference Louis R (1986) Fusion of the lumbar and sacral spine by internal fixation with screw plates with screw plates. Clin Orthop Relat Res 203:18–33PubMed Louis R (1986) Fusion of the lumbar and sacral spine by internal fixation with screw plates with screw plates. Clin Orthop Relat Res 203:18–33PubMed
32.
go back to reference Robertson PA, Plank LD (1999) Pedicle screw placement at the sacrum: anatomical characterization and limitations at S1. J Spinal Disord 12:227–233PubMed Robertson PA, Plank LD (1999) Pedicle screw placement at the sacrum: anatomical characterization and limitations at S1. J Spinal Disord 12:227–233PubMed
33.
go back to reference Kaptanoglu E, Okutan O, Tekdemir I, Beskonakli E, Deda H (2003) Closed posterior superior iliac spine impeding pediculocorporeal S-1 screw insertion. J Neurosurg 99(2 Suppl):29–34 Kaptanoglu E, Okutan O, Tekdemir I, Beskonakli E, Deda H (2003) Closed posterior superior iliac spine impeding pediculocorporeal S-1 screw insertion. J Neurosurg 99(2 Suppl):29–34
34.
go back to reference Asher MA, Strippgen WE (1986) Antrhopometric studies of the human sacrum relating to dorsal transsacral implant. Clin Orthop Relat Res 203:58–62PubMed Asher MA, Strippgen WE (1986) Antrhopometric studies of the human sacrum relating to dorsal transsacral implant. Clin Orthop Relat Res 203:58–62PubMed
35.
go back to reference Xu R, Ebraheim NA, Mohamed A, el-Gamal H, Yeasting RA (1995) Anatomic considerations for dorsal sacral plate-screw placement. J Spinal Disord 8:352–356PubMed Xu R, Ebraheim NA, Mohamed A, el-Gamal H, Yeasting RA (1995) Anatomic considerations for dorsal sacral plate-screw placement. J Spinal Disord 8:352–356PubMed
36.
go back to reference Waikakul S, Chandraphak S, Sangthongsil P (2010) Anatomy of L4 to S3 nerve roots. J Orthop Surg (Hong Kong) 18:352–355 Waikakul S, Chandraphak S, Sangthongsil P (2010) Anatomy of L4 to S3 nerve roots. J Orthop Surg (Hong Kong) 18:352–355
Metadata
Title
L5 spinal nerve injury caused by misplacement of outwardly-inserted S1 pedicle screws
Authors
Masahiro Inoue
Gen Inoue
Tomoyuki Ozawa
Masayuki Miyagi
Hiroto Kamoda
Tetsuhiro Ishikawa
Miyako Suzuki
Yoshihiro Sakuma
Yasuhiro Oikawa
Kazuyo Yamauchi
Sumihisa Orita
Masashi Takaso
Tomoaki Toyone
Kazuhisa Takahashi
Seiji Ohtori
Publication date
01-05-2013
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue Special Issue 3/2013
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-012-2634-z

Other articles of this Special Issue 3/2013

European Spine Journal 3/2013 Go to the issue