Skip to main content
Top
Published in: Documenta Ophthalmologica 1/2016

01-08-2016 | ISCEV Standards

ISCEV standard for clinical visual evoked potentials: (2016 update)

Authors: J. Vernon Odom, Michael Bach, Mitchell Brigell, Graham E. Holder, Daphne L. McCulloch, Atsushi Mizota, Alma Patrizia Tormene, International Society for Clinical Electrophysiology of Vision

Published in: Documenta Ophthalmologica | Issue 1/2016

Login to get access

Abstract

Visual evoked potentials (VEPs) can provide important diagnostic information regarding the functional integrity of the visual system. This document updates the ISCEV standard for clinical VEP testing and supersedes the 2009 standard. The main changes in this revision are the acknowledgment that pattern stimuli can be produced using a variety of technologies with an emphasis on the need for manufacturers to ensure that there is no luminance change during pattern reversal or pattern onset/offset. The document is also edited to bring the VEP standard into closer harmony with other ISCEV standards. The ISCEV standard VEP is based on a subset of stimulus and recording conditions that provide core clinical information and can be performed by most clinical electrophysiology laboratories throughout the world. These are: (1) Pattern-reversal VEPs elicited by checkerboard stimuli with large 1 degree (°) and small 0.25° checks. (2) Pattern onset/offset VEPs elicited by checkerboard stimuli with large 1° and small 0.25° checks. (3) Flash VEPs elicited by a flash (brief luminance increment) which subtends a visual field of at least 20°. The ISCEV standard VEP protocols are defined for a single recording channel with a midline occipital active electrode. These protocols are intended for assessment of the eye and/or optic nerves anterior to the optic chiasm. Extended, multi-channel protocols are required to evaluate postchiasmal lesions.
Footnotes
1
A major determinant of the waveform of a VEP is the temporal frequency of the stimulus. At rapid stimulation rates, the waveform becomes approximately sinusoidal and is termed steady-state VEP. VEPs recorded with stimulation at lower temporal frequencies are termed transient VEPs.
 
2
Michelson contrast = {[L max − L min]/[L max + L min]} × 100 %, where L = luminance, max = maximum of the white squares and min = minimum of the black squares.
 
Literature
1.
go back to reference Odom JV, Bach M, Brigell M, Holder GE, McCulloch DL, Tormene AP (2010) ISCEV standard for clinical visual evoked potentials (2009 update). Doc Ophthalmol 120:111–119CrossRefPubMed Odom JV, Bach M, Brigell M, Holder GE, McCulloch DL, Tormene AP (2010) ISCEV standard for clinical visual evoked potentials (2009 update). Doc Ophthalmol 120:111–119CrossRefPubMed
2.
go back to reference McCulloch DL, Marmor MF, Brigell MG, Hamilton R, Holder GE, Tzekov R, Bach M (2015) ISCEV Standard for full-field clinical electroretinography (2015 update). Doc Ophthalmol 130:1–12 (Erratum: Table 1 in the above publication gives an incorrect number as the lower bandpass for dark-adapted OPs. The correct value is “75 Hz”, as correctly stated on page 8, 2nd paragraph) McCulloch DL, Marmor MF, Brigell MG, Hamilton R, Holder GE, Tzekov R, Bach M (2015) ISCEV Standard for full-field clinical electroretinography (2015 update). Doc Ophthalmol 130:1–12 (Erratum: Table 1 in the above publication gives an incorrect number as the lower bandpass for dark-adapted OPs. The correct value is “75 Hz”, as correctly stated on page 8, 2nd paragraph)
3.
go back to reference Hood DC, Bach M, Brigell M, Keating D, Kondo M, Lyons JS, Marmor MF, McCulloch DL, Palmowski-Wolfe AM (2012) ISCEV standard for clinical multifocal electroretinography (2011 edition). Doc Ophthalmol 124:1–13CrossRefPubMed Hood DC, Bach M, Brigell M, Keating D, Kondo M, Lyons JS, Marmor MF, McCulloch DL, Palmowski-Wolfe AM (2012) ISCEV standard for clinical multifocal electroretinography (2011 edition). Doc Ophthalmol 124:1–13CrossRefPubMed
4.
go back to reference Bach M, Brigell MG, Hawlina M, Holder GE, Johnson MA, McCulloch DL, Meigen T, Viswanathan S (2013) ISCEV standard for clinical pattern electroretinography (PERG)—2012 update. Doc Ophthalmol 126:1–7CrossRefPubMed Bach M, Brigell MG, Hawlina M, Holder GE, Johnson MA, McCulloch DL, Meigen T, Viswanathan S (2013) ISCEV standard for clinical pattern electroretinography (PERG)—2012 update. Doc Ophthalmol 126:1–7CrossRefPubMed
5.
go back to reference Marmor MF, Brigell MG, Westall CA, Bach M (2011) ISCEV standard for clinical electro-oculography (2010 update). Doc Ophthalmol 122:1–7CrossRefPubMed Marmor MF, Brigell MG, Westall CA, Bach M (2011) ISCEV standard for clinical electro-oculography (2010 update). Doc Ophthalmol 122:1–7CrossRefPubMed
6.
go back to reference Brigell M, Bach M, Barber C, Moskowitz A, Robson J (2003) Guidelines for calibration of stimulus and recording parameters used in clinical electrophysiology of vision. Doc Ophthalmol 107:185–193CrossRefPubMed Brigell M, Bach M, Barber C, Moskowitz A, Robson J (2003) Guidelines for calibration of stimulus and recording parameters used in clinical electrophysiology of vision. Doc Ophthalmol 107:185–193CrossRefPubMed
7.
go back to reference American Clinical Neurophysiology Society (2006) Guideline 5: guidelines for standard electrode position nomenclature. J Clin Neurophysiol 23:107–110. https://www.acns.org/ American Clinical Neurophysiology Society (2006) Guideline 5: guidelines for standard electrode position nomenclature. J Clin Neurophysiol 23:107–110. https://​www.​acns.​org/​
Metadata
Title
ISCEV standard for clinical visual evoked potentials: (2016 update)
Authors
J. Vernon Odom
Michael Bach
Mitchell Brigell
Graham E. Holder
Daphne L. McCulloch
Atsushi Mizota
Alma Patrizia Tormene
International Society for Clinical Electrophysiology of Vision
Publication date
01-08-2016
Publisher
Springer Berlin Heidelberg
Published in
Documenta Ophthalmologica / Issue 1/2016
Print ISSN: 0012-4486
Electronic ISSN: 1573-2622
DOI
https://doi.org/10.1007/s10633-016-9553-y

Other articles of this Issue 1/2016

Documenta Ophthalmologica 1/2016 Go to the issue