Skip to main content
Top
Published in: Journal of Cardiothoracic Surgery 1/2010

Open Access 01-12-2010 | Research article

Is distortion of the bioprosthesis ring a risk factor for early calcification?

Authors: Jose Manuel Martinez Cereijo, Jose Rubio Alvarez, Juan Sierra Quiroga, Anxo Martinez de Alegria, Jose Manuel Suarez Peñaranda

Published in: Journal of Cardiothoracic Surgery | Issue 1/2010

Login to get access

Abstract

Background

As the population ages, bioprosthesis are increasingly being used in cardiac valve replacement. Pericardial bioprosthesis combine an excellent hemodynamic performance with low thrombogenicity, but valve failure associated with calcification remains a concern with these valves. We describe distortion of the bioprosthesis ring as a risk factor for early calcification.

Methods

A total of 510 patients over the age of 70 years underwent isolated aortic valve replacement with the Mitroflow (A12) pericardial bioprosthesis. Thirty two patients (6,2%) have undergone a second aortic valve replacement due to structural valve dysfunction resulting from valve calcification. In all patients a chest radiography and coronary angiography was performed before reoperation. A 64 Multidetector Computed Tomography (MDCT) with retrospective ECG gating study was performed in four patients to evaluate the aortic bioprosthesis.

Results

Chest radiography showed in all patients an irregular bioprosthesis ring. At preoperative coronary angiography a distorted bioprosthesis ring was detected in all patients. Macroscopic findings of the explanted bioprostheses included extensive calcification in all specimens.

Conclusion

There was a possible relationship between early bioprosthetic calcification and radiologic distortion of the bioprosthesis ring.
Appendix
Available only for authorised users
Literature
1.
go back to reference Bengochea JG, Sierra J, Gonzalez - Juanatey JR, Rubio J, Vega M, Fernandez AL, Sanchez D: Left ventricular mass regressión after aortic valve replacement with the new Mitroflow 12 A pericardial bioprosthesis. J Heart Valve Dis. 2006, 15: 446-452. Bengochea JG, Sierra J, Gonzalez - Juanatey JR, Rubio J, Vega M, Fernandez AL, Sanchez D: Left ventricular mass regressión after aortic valve replacement with the new Mitroflow 12 A pericardial bioprosthesis. J Heart Valve Dis. 2006, 15: 446-452.
2.
go back to reference Corbineau H, De la Tour B, Verhoye JP, Langanay Th, Lelong B, Leguerrier A: Carpentier-Edwards supraannular porcine bioprosthesis in aortic position: 16-year experience. Ann Thorac Surg. 2001, 71: S228-S231. 10.1016/S0003-4975(01)02545-0.CrossRefPubMed Corbineau H, De la Tour B, Verhoye JP, Langanay Th, Lelong B, Leguerrier A: Carpentier-Edwards supraannular porcine bioprosthesis in aortic position: 16-year experience. Ann Thorac Surg. 2001, 71: S228-S231. 10.1016/S0003-4975(01)02545-0.CrossRefPubMed
3.
go back to reference Rubio J, Sierra J, Vega M, Adrio B, Martinez Comendador JM, Gude F, Martinez Cereijo JM, Garcia J: Early calcification of the aortic Mitroflow pericardial bioprosthesis in the elderly. Interact Cardio Vasc Thorac Surg. 2009, 9: 842-846. 10.1510/icvts.2009.204958.CrossRef Rubio J, Sierra J, Vega M, Adrio B, Martinez Comendador JM, Gude F, Martinez Cereijo JM, Garcia J: Early calcification of the aortic Mitroflow pericardial bioprosthesis in the elderly. Interact Cardio Vasc Thorac Surg. 2009, 9: 842-846. 10.1510/icvts.2009.204958.CrossRef
4.
go back to reference Liao KK, Li X, Ranjit J, Amayta DM, Joyce LD, Park SJ, Bianco R, Bolman RM: Mechanical stress: An independent determinant of early bioprosthetic calcification in humans. Ann Thorac Surg. 2008, 86: 491-495. 10.1016/j.athoracsur.2008.03.061.CrossRefPubMed Liao KK, Li X, Ranjit J, Amayta DM, Joyce LD, Park SJ, Bianco R, Bolman RM: Mechanical stress: An independent determinant of early bioprosthetic calcification in humans. Ann Thorac Surg. 2008, 86: 491-495. 10.1016/j.athoracsur.2008.03.061.CrossRefPubMed
5.
go back to reference Bernacca GM, Fisher AC, Wilkinson R, Mackay TG, Wheatley D: Calcification and stress distribution in bovine pericardial heart valves. J Biomed Mater Res. 1992, 26: 959-966. 10.1002/jbm.820260710.CrossRefPubMed Bernacca GM, Fisher AC, Wilkinson R, Mackay TG, Wheatley D: Calcification and stress distribution in bovine pericardial heart valves. J Biomed Mater Res. 1992, 26: 959-966. 10.1002/jbm.820260710.CrossRefPubMed
6.
go back to reference Saunders PC, Grossi EA, Esposito RA, Bizekis CS, Strong MD, Colvin SB: Failure of four bovine pericardial mitral prostheses. J Thorac Cardiovasc Surg. 2004, 127: 267-268. 10.1016/S0022-5223(03)00724-4.CrossRefPubMed Saunders PC, Grossi EA, Esposito RA, Bizekis CS, Strong MD, Colvin SB: Failure of four bovine pericardial mitral prostheses. J Thorac Cardiovasc Surg. 2004, 127: 267-268. 10.1016/S0022-5223(03)00724-4.CrossRefPubMed
Metadata
Title
Is distortion of the bioprosthesis ring a risk factor for early calcification?
Authors
Jose Manuel Martinez Cereijo
Jose Rubio Alvarez
Juan Sierra Quiroga
Anxo Martinez de Alegria
Jose Manuel Suarez Peñaranda
Publication date
01-12-2010
Publisher
BioMed Central
Published in
Journal of Cardiothoracic Surgery / Issue 1/2010
Electronic ISSN: 1749-8090
DOI
https://doi.org/10.1186/1749-8090-5-77

Other articles of this Issue 1/2010

Journal of Cardiothoracic Surgery 1/2010 Go to the issue