Skip to main content
Top
Published in: International Orthopaedics 4/2021

01-04-2021 | Review Article

Is coating of titanium implants effective at preventing Staphylococcus aureus infections? A meta-analysis of animal model studies

Authors: Konstantinos Tsikopoulos, Konstantinos Sidiropoulos, Dimitrios Kitridis, Anas Hassan, Lorenzo Drago, Andreas Mavrogenis, Donald McBride

Published in: International Orthopaedics | Issue 4/2021

Login to get access

Abstract

Aim of the study

To assess the effects of the available coating methods against methicillin-resistant Staphylococcus aureus (MRSA) and methicillin-susceptible S. aureus (MSSA) biofilm development on titanium implants.

Methods

We searched the MEDLINE, Embase, and CENTRAL databases until May 18, 2019, for studies that used animal models of infections to evaluate various titanium implant coating methods to prevent S. aureus infection. Twenty-seven studies were eligible for inclusion in qualitative synthesis. Of those, twenty-three were considered in pair-wise meta-analysis. In addition, subgroup analysis of implant protection strategies relative to uncoated controls was performed, and any adverse events stemming from the coating applications were reported. Quality assessment was performed using SYRCLE’s risk of bias tool for animal studies.

Results

Meta-analysis showed that active coating with antibiotics was favoured over uncoated controls (standardised mean differences [SMD] for MRSA and MSSA were – 2.71 [95% CI, − 4.24 to − 1.18], p = 0.0005, and − 2.5 [− 3.79 to − 1.22], p = 0.0001, respectively). Likewise, large effect sizes were demonstrated when a combination of active and conventional non-degradable passive coatings was compared with controls (SMDs for MRSA and MSSA were – 0.62 [95% CI, − 1.15 to − 0.08], p = 0.02, and − 1.93 [95% CI, − 2.87 to − 0.98], p < 0.001, respectively).

Discussion/conclusion

As a standalone prevention method, active titanium coating with antibiotics yielded promising results against both MSSA and MRSA. Combinations between active and non-degradable passive coatings, potentially allowing for sustained antimicrobial substance release, provided consistent hardware infection protection. Thus, we recommend that future research efforts focus on combined coating modalities against S. aureus biofilm infections in the presence of titanium implants.

Systematic Review Registration

CRD42019123462
Appendix
Available only for authorised users
Literature
3.
go back to reference Lenguerrand E, Whitehouse MR, Beswick AD, Toms AD, Porter ML, Blom AW (2017) Description of the rates, trends and surgical burden associated with revision for prosthetic joint infection following primary and revision knee replacements in England and Wales: an analysis of the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man. BMJ Open 7(7):–e014056. https://doi.org/10.1136/bmjopen-2016-014056 Lenguerrand E, Whitehouse MR, Beswick AD, Toms AD, Porter ML, Blom AW (2017) Description of the rates, trends and surgical burden associated with revision for prosthetic joint infection following primary and revision knee replacements in England and Wales: an analysis of the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man. BMJ Open 7(7):–e014056. https://​doi.​org/​10.​1136/​bmjopen-2016-014056
5.
go back to reference Berbari EF, Osmon DR, Lahr B, Eckel-Passow JE, Tsaras G, Hanssen AD, Mabry T, Steckelberg J, Thompson R (2012) The Mayo prosthetic joint infection risk score: implication for surgical site infection reporting and risk stratification. Infect Control Hosp Epidemiol 33(8):774–781. https://doi.org/10.1086/666641CrossRefPubMed Berbari EF, Osmon DR, Lahr B, Eckel-Passow JE, Tsaras G, Hanssen AD, Mabry T, Steckelberg J, Thompson R (2012) The Mayo prosthetic joint infection risk score: implication for surgical site infection reporting and risk stratification. Infect Control Hosp Epidemiol 33(8):774–781. https://​doi.​org/​10.​1086/​666641CrossRefPubMed
10.
go back to reference Saeidnia S, Manayi A, Abdollahi M (2015) From in vitro experiments to in vivo and clinical studies; pros and cons. Curr Drug Discov Technol 12(4):218–224CrossRefPubMed Saeidnia S, Manayi A, Abdollahi M (2015) From in vitro experiments to in vivo and clinical studies; pros and cons. Curr Drug Discov Technol 12(4):218–224CrossRefPubMed
13.
go back to reference Geetha M, Singh AK, Asokamani R, Gogia AK (2009) Ti based biomaterials, the ultimate choice for orthopaedic implants – a review. Prog Mater Sci 54(3):397–425CrossRef Geetha M, Singh AK, Asokamani R, Gogia AK (2009) Ti based biomaterials, the ultimate choice for orthopaedic implants – a review. Prog Mater Sci 54(3):397–425CrossRef
14.
go back to reference Miller (2017) Miller’s Review of Orthopaedics. In: Miller’s Review of Orthopaedics, 7th edn, pp 94 Miller (2017) Miller’s Review of Orthopaedics. In: Miller’s Review of Orthopaedics, 7th edn, pp 94
17.
go back to reference Higgins JPT, Altman DG, Sterne JAC (editors). Chapter 8: assessing risk of bias in included studies. In: Higgins JPT, Green S (editors). Cochrane handbook for systematic reviews of interventions Version 5.1.0 (updated March 2011). The Cochrane Collaboration, 2011. Available from www.handbook.cochrane.org Higgins JPT, Altman DG, Sterne JAC (editors). Chapter 8: assessing risk of bias in included studies. In: Higgins JPT, Green S (editors). Cochrane handbook for systematic reviews of interventions Version 5.1.0 (updated March 2011). The Cochrane Collaboration, 2011. Available from www.​handbook.​cochrane.​org
18.
go back to reference Sterne JAC, Egger M, Moher D (2008) Chapter 10: addressing reporting biases. In: Higgins JPT, Green S (eds) Cochrane handbook for systematic reviews of interventions. John Wiley & Sons, Chichester (UK) Sterne JAC, Egger M, Moher D (2008) Chapter 10: addressing reporting biases. In: Higgins JPT, Green S (eds) Cochrane handbook for systematic reviews of interventions. John Wiley & Sons, Chichester (UK)
21.
go back to reference Deeks JJ, Higgins JPT, Altman DG (2008) Chapter 9: analysing data and undertaking meta-analyses. In: Higgins JPT, Green S (eds) Cochrane handbook for systematic reviews of interventions. John Wiley & Sons, Chichester (UK) Deeks JJ, Higgins JPT, Altman DG (2008) Chapter 9: analysing data and undertaking meta-analyses. In: Higgins JPT, Green S (eds) Cochrane handbook for systematic reviews of interventions. John Wiley & Sons, Chichester (UK)
22.
go back to reference Review Manager (RevMan) [Computer program]. Version 5.3. Copenhagen: The Nordic Cochrane Centre, The Cochrane Collaboration, 2014 Review Manager (RevMan) [Computer program]. Version 5.3. Copenhagen: The Nordic Cochrane Centre, The Cochrane Collaboration, 2014
23.
go back to reference Schunemann HJ, Oxman AD, Vist GE, Higgins JPT, Deeks JJ, Glasziou P, Guyatt GH (2008) Chapter 12: interpreting results and drawing conclusions. In: Higgins JPT, Green S (eds) Cochrane handbook for systematic reviews of interventions. John Wiley & Sons, Chichester (UK) Schunemann HJ, Oxman AD, Vist GE, Higgins JPT, Deeks JJ, Glasziou P, Guyatt GH (2008) Chapter 12: interpreting results and drawing conclusions. In: Higgins JPT, Green S (eds) Cochrane handbook for systematic reviews of interventions. John Wiley & Sons, Chichester (UK)
24.
go back to reference Cohen J (1988) Statistical power analysis for the behavioral sciences. Lawrence Erlbaum Associates, Hillsdale, NJ, U.S.A Cohen J (1988) Statistical power analysis for the behavioral sciences. Lawrence Erlbaum Associates, Hillsdale, NJ, U.S.A
25.
28.
go back to reference Metsemakers WJ, Emanuel N, Cohen O, Reichart M, Potapova I, Schmid T, Segal D, Riool M, Kwakman PH, de Boer L, de Breij A, Nibbering PH, Richards RG, Zaat SA, Moriarty TF (2015) A doxycycline-loaded polymer-lipid encapsulation matrix coating for the prevention of implant-related osteomyelitis due to doxycycline-resistant methicillin-resistant Staphylococcus aureus. J Control Release 209:47–56. https://doi.org/10.1016/j.jconrel.2015.04.022CrossRefPubMed Metsemakers WJ, Emanuel N, Cohen O, Reichart M, Potapova I, Schmid T, Segal D, Riool M, Kwakman PH, de Boer L, de Breij A, Nibbering PH, Richards RG, Zaat SA, Moriarty TF (2015) A doxycycline-loaded polymer-lipid encapsulation matrix coating for the prevention of implant-related osteomyelitis due to doxycycline-resistant methicillin-resistant Staphylococcus aureus. J Control Release 209:47–56. https://​doi.​org/​10.​1016/​j.​jconrel.​2015.​04.​022CrossRefPubMed
30.
go back to reference Sinclair KD, Pham TX, Williams DL, Farnsworth RW, Loc-Carrillo CM, Bloebaum RD (2013) Model development for determining the efficacy of a combination coating for the prevention of perioperative device related infections: a pilot study. J Biomed Mater Res B Appl Biomater 101(7):1143–1153. https://doi.org/10.1002/jbm.b.32924CrossRefPubMed Sinclair KD, Pham TX, Williams DL, Farnsworth RW, Loc-Carrillo CM, Bloebaum RD (2013) Model development for determining the efficacy of a combination coating for the prevention of perioperative device related infections: a pilot study. J Biomed Mater Res B Appl Biomater 101(7):1143–1153. https://​doi.​org/​10.​1002/​jbm.​b.​32924CrossRefPubMed
31.
go back to reference Moojen DJ, Vogely HC, Fleer A, Nikkels PG, Higham PA, Verbout AJ, Castelein RM, Dhert WJ (2009) Prophylaxis of infection and effects on osseointegration using a tobramycin-periapatite coating on titanium implants--an experimental study in the rabbit. J Orthop Res 27(6):710–716. https://doi.org/10.1002/jor.20808CrossRefPubMed Moojen DJ, Vogely HC, Fleer A, Nikkels PG, Higham PA, Verbout AJ, Castelein RM, Dhert WJ (2009) Prophylaxis of infection and effects on osseointegration using a tobramycin-periapatite coating on titanium implants--an experimental study in the rabbit. J Orthop Res 27(6):710–716. https://​doi.​org/​10.​1002/​jor.​20808CrossRefPubMed
32.
go back to reference Bouloussa H, Humblot V, Court C (2017) Comparative description of in vitro and in vivo MRSA biofilms on titanium surfaces: why animal models still matter. Spine J 17(10):S167–S168CrossRef Bouloussa H, Humblot V, Court C (2017) Comparative description of in vitro and in vivo MRSA biofilms on titanium surfaces: why animal models still matter. Spine J 17(10):S167–S168CrossRef
33.
34.
go back to reference Darouiche RO, Mansouri MD, Zakarevicz D, Alsharif A, Landon GC (2007) In vivo efficacy of antimicrobial-coated devices. J Bone Joint Surg Am 89(4):792–797CrossRefPubMed Darouiche RO, Mansouri MD, Zakarevicz D, Alsharif A, Landon GC (2007) In vivo efficacy of antimicrobial-coated devices. J Bone Joint Surg Am 89(4):792–797CrossRefPubMed
40.
go back to reference Riool M, Dirks AJ, Jaspers V, de Boer L, Loontjens TJ, van der Loos CM, Florquin S, Apachitei I, Rijk LN, Keul HA, Zaat SA (2017) A chlorhexidine-releasing epoxy-based coating on titanium implants prevents Staphylococcus aureus experimental biomaterial-associated infection. Eur Cell Mater 33:143–157. https://doi.org/10.22203/eCM.v033a11CrossRefPubMed Riool M, Dirks AJ, Jaspers V, de Boer L, Loontjens TJ, van der Loos CM, Florquin S, Apachitei I, Rijk LN, Keul HA, Zaat SA (2017) A chlorhexidine-releasing epoxy-based coating on titanium implants prevents Staphylococcus aureus experimental biomaterial-associated infection. Eur Cell Mater 33:143–157. https://​doi.​org/​10.​22203/​eCM.​v033a11CrossRefPubMed
42.
go back to reference Antoci V Jr, Adams CS, Parvizi J, Ducheyne P, Shapiro IM, Hickok NJ (2007) Covalently attached vancomycin provides a nanoscale antibacterial surface. Clin Orthop Relat Res 461:81–87CrossRefPubMed Antoci V Jr, Adams CS, Parvizi J, Ducheyne P, Shapiro IM, Hickok NJ (2007) Covalently attached vancomycin provides a nanoscale antibacterial surface. Clin Orthop Relat Res 461:81–87CrossRefPubMed
45.
go back to reference Lucke M, Schmidmaier G, Sadoni S, Wildemann B, Schiller R, Haas NP, Raschke M (2003) Gentamicin coating of metallic implants reduces implant-related osteomyelitis in rats. Bone 32(5):521–531CrossRefPubMed Lucke M, Schmidmaier G, Sadoni S, Wildemann B, Schiller R, Haas NP, Raschke M (2003) Gentamicin coating of metallic implants reduces implant-related osteomyelitis in rats. Bone 32(5):521–531CrossRefPubMed
49.
50.
go back to reference Terrin N, Schmid CH, Lau J (2005) In an empirical evaluation of the funnel plot, researchers could not visually identify publication bias. J Clin Epidemiol 58(9):894–901CrossRefPubMed Terrin N, Schmid CH, Lau J (2005) In an empirical evaluation of the funnel plot, researchers could not visually identify publication bias. J Clin Epidemiol 58(9):894–901CrossRefPubMed
51.
go back to reference Higgins JP, Thompson SG (2004) Controlling the risk of spurious findings from meta-regression. Stat Med 23(11):1663–1682CrossRefPubMed Higgins JP, Thompson SG (2004) Controlling the risk of spurious findings from meta-regression. Stat Med 23(11):1663–1682CrossRefPubMed
52.
go back to reference Sterne JA, Sutton AJ, Ioannidis JP, Terrin N, Jones DR, Lau J, Carpenter J, Rücker G, Harbord RM, Schmid CH, Tetzlaff J, Deeks JJ, Peters J, Macaskill P, Schwarzer G, Duval S, Altman DG, Moher D, Higgins JP (2011) Recommendations for examining and interpreting funnel plot asymmetry in meta-analyses of randomised controlled trials. BMJ 343:d4002. https://doi.org/10.1136/bmj.d4002CrossRefPubMed Sterne JA, Sutton AJ, Ioannidis JP, Terrin N, Jones DR, Lau J, Carpenter J, Rücker G, Harbord RM, Schmid CH, Tetzlaff J, Deeks JJ, Peters J, Macaskill P, Schwarzer G, Duval S, Altman DG, Moher D, Higgins JP (2011) Recommendations for examining and interpreting funnel plot asymmetry in meta-analyses of randomised controlled trials. BMJ 343:d4002. https://​doi.​org/​10.​1136/​bmj.​d4002CrossRefPubMed
Metadata
Title
Is coating of titanium implants effective at preventing Staphylococcus aureus infections? A meta-analysis of animal model studies
Authors
Konstantinos Tsikopoulos
Konstantinos Sidiropoulos
Dimitrios Kitridis
Anas Hassan
Lorenzo Drago
Andreas Mavrogenis
Donald McBride
Publication date
01-04-2021
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 4/2021
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-020-04660-4

Other articles of this Issue 4/2021

International Orthopaedics 4/2021 Go to the issue