Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 5/2016

01-10-2016 | Original Research

Investigation of peripheral photoplethysmographic morphology changes induced during a hand-elevation study

Authors: Michelle Hickey, Justin P. Phillips, Panayiotis A. Kyriacou

Published in: Journal of Clinical Monitoring and Computing | Issue 5/2016

Login to get access

Abstract

A hand-elevation study was carried out in the laboratory in order to alter peripheral blood flow with the aim of increasing understanding of factors affecting the morphology of peripheral photoplethysmographic signals. Photoplethysmographic (PPG) signals were recorded from twenty healthy volunteer subjects during a hand-elevation study in which the right hand was raised and lowered relative to heart level, while the left hand remained static. Red and infrared (IR) PPG signals were obtained from the right and left index fingers using a custom-made PPG processing system. PPG features were identified using a feature-detection algorithm based on the first derivative of the PPG signal. The systolic PPG amplitude, the reflection index, crest time, pulse width at half height, and delta T were calculated from 20 s IR PPG signals from three positions of the right hand with respect to heart level (−50, 0, +50 cm) in 19 volunteers. PPG features were found to change with hand elevation. On lowering the hand to 50 cm below heart level, ac systolic PPG amplitudes from the finger decreased by 68.32 %, while raising the arm increased the systolic amplitude by 69.99 %. These changes in amplitude were attributed to changes in hydrostatic pressure and the veno-arterial reflex. Other morphological variables, such as crest time, were found to be statistically significantly different across hand positions, indicating increased vascular resistance on arm elevation than on dependency. It was hypothesized that these morphological PPG changes were influenced by changes in downstream venous resistance, rather than arterial, or arteriolar, resistance. Changes in hand position relative to heart level can significantly affect the morphology of the peripheral ac PPG waveform. These alterations are due to a combination of physical effects and physiological responses to changes in hand position, which alter vascular resistance. Care should be taken when interpreting morphological data derived from PPG signals and methods should be standardized to take these effects into account.
Literature
1.
go back to reference Allen J. Photoplethysmography and its application in clinical physiological measurement. Physiol Meas. 2007;28:R1–39.CrossRefPubMed Allen J. Photoplethysmography and its application in clinical physiological measurement. Physiol Meas. 2007;28:R1–39.CrossRefPubMed
2.
go back to reference Kyriacou PA. Direct pulse oximetry within the esophagus, on the surface of abdominal viscera, and on free flaps. Anesth Analg. 2013;117:824–33.CrossRefPubMed Kyriacou PA. Direct pulse oximetry within the esophagus, on the surface of abdominal viscera, and on free flaps. Anesth Analg. 2013;117:824–33.CrossRefPubMed
3.
go back to reference Selvaraj N, Jaryal AK, Santhosh J, Anand S, Deepak KK. Monitoring of reactive hyperemia using photoplethysmographic pulse amplitude and transit time. J Clin Monit Comput. 2009;23(5):315–22.CrossRefPubMed Selvaraj N, Jaryal AK, Santhosh J, Anand S, Deepak KK. Monitoring of reactive hyperemia using photoplethysmographic pulse amplitude and transit time. J Clin Monit Comput. 2009;23(5):315–22.CrossRefPubMed
4.
go back to reference Meredith DJ, Clifton D, Charlton P, Brooks J, Pugh CW, Tarassenko L. Photoplethysmographic derivation of respiratory rate: a review of relevant physiology. J Med Eng Technol. 2012;36(1):1–7.CrossRefPubMed Meredith DJ, Clifton D, Charlton P, Brooks J, Pugh CW, Tarassenko L. Photoplethysmographic derivation of respiratory rate: a review of relevant physiology. J Med Eng Technol. 2012;36(1):1–7.CrossRefPubMed
5.
go back to reference Reisner A, Shaltis PA, McCombie D, Asada HH. Utility of the photoplethysmogram in circulatory monitoring. Anesthesiology. 2008;108:950–8.CrossRefPubMed Reisner A, Shaltis PA, McCombie D, Asada HH. Utility of the photoplethysmogram in circulatory monitoring. Anesthesiology. 2008;108:950–8.CrossRefPubMed
6.
go back to reference Chan GS, Fazalbhoy A, Birznieks I, Macefield VG, Middleton PM, Lovell NH. Spontaneous fluctuations in the peripheral photoplethysmographic waveform: roles of arterial pressure and muscle sympathetic nerve activity. Am J Physiol Heart Circ Physiol. 2012;302(3):H826–36.CrossRefPubMed Chan GS, Fazalbhoy A, Birznieks I, Macefield VG, Middleton PM, Lovell NH. Spontaneous fluctuations in the peripheral photoplethysmographic waveform: roles of arterial pressure and muscle sympathetic nerve activity. Am J Physiol Heart Circ Physiol. 2012;302(3):H826–36.CrossRefPubMed
7.
go back to reference Angius G, Barcellona D, Cauli E, Meloni L, Raffo L. Myocardial infarction and antiphospholipid syndrome: a first study on finger PPG waveforms effects. Comput Cardiol. 2012;39:517–20. Angius G, Barcellona D, Cauli E, Meloni L, Raffo L. Myocardial infarction and antiphospholipid syndrome: a first study on finger PPG waveforms effects. Comput Cardiol. 2012;39:517–20.
8.
go back to reference Millasseau SC, Rittera JM, Takazawab K, Chowienczyk PJ. Contour analysis of the photoplethysmographic pulse measured at the finger. J Hypertens. 2006;24:1449–56.CrossRefPubMed Millasseau SC, Rittera JM, Takazawab K, Chowienczyk PJ. Contour analysis of the photoplethysmographic pulse measured at the finger. J Hypertens. 2006;24:1449–56.CrossRefPubMed
9.
go back to reference Alty SR, Angarita-Jaimes N, Millasseau SC, Chowienczyk PJ. Predicting arterial stiffness from the digital volume pulse waveform. IEEE Trans Biomed Eng. 2007;54:2268–75.CrossRefPubMed Alty SR, Angarita-Jaimes N, Millasseau SC, Chowienczyk PJ. Predicting arterial stiffness from the digital volume pulse waveform. IEEE Trans Biomed Eng. 2007;54:2268–75.CrossRefPubMed
11.
go back to reference Budidha K, Kyriacou PA. The human ear canal: investigation of its suitability for monitoring photoplethysmographs and arterial oxygen saturation. Physiol Meas. 2014;35(2):111–28.CrossRefPubMed Budidha K, Kyriacou PA. The human ear canal: investigation of its suitability for monitoring photoplethysmographs and arterial oxygen saturation. Physiol Meas. 2014;35(2):111–28.CrossRefPubMed
12.
go back to reference McEniery CM, Yasmin PHD, Hall IR, Qasem A, Wilkinson IB, Cockcroft JR. Normal vascular aging: differential effects on wave reflection and aortic pulse wave velocity: the Anglo-Cardiff Collaborative Trial (ACCT). J Am Coll Cardiol. 2005;46(9):1753–60.CrossRefPubMed McEniery CM, Yasmin PHD, Hall IR, Qasem A, Wilkinson IB, Cockcroft JR. Normal vascular aging: differential effects on wave reflection and aortic pulse wave velocity: the Anglo-Cardiff Collaborative Trial (ACCT). J Am Coll Cardiol. 2005;46(9):1753–60.CrossRefPubMed
13.
go back to reference Rubins U, Grabovskis A, Grube J, Kukulis I. Photoplethysmography analysis of artery properties in patients with cardiovascular diseases. IFMBE Proc. 2008;20:319–22.CrossRef Rubins U, Grabovskis A, Grube J, Kukulis I. Photoplethysmography analysis of artery properties in patients with cardiovascular diseases. IFMBE Proc. 2008;20:319–22.CrossRef
14.
go back to reference Yousef Q, Reaz MBI, Ali MAM. The analysis of PPG morphology: investigating the effects of aging on arterial compliance. Meas Sci Rev. 2012;12:266–71.CrossRef Yousef Q, Reaz MBI, Ali MAM. The analysis of PPG morphology: investigating the effects of aging on arterial compliance. Meas Sci Rev. 2012;12:266–71.CrossRef
15.
go back to reference Lee QY, Chan GS, Redmond SJ, Middleton PM, Steel E, Malouf P, Critoph C, Flynn G, O’Lone E, Lovell NH. Multivariate classification of systemic vascular resistance using photoplethysmography. Physiol Meas. 2011;32:1117–32.CrossRefPubMed Lee QY, Chan GS, Redmond SJ, Middleton PM, Steel E, Malouf P, Critoph C, Flynn G, O’Lone E, Lovell NH. Multivariate classification of systemic vascular resistance using photoplethysmography. Physiol Meas. 2011;32:1117–32.CrossRefPubMed
16.
go back to reference Awad AA, Haddadin AS, Tantawy H, Badr TM, Stout RG, Silverman DG, Shelley KH. The relationship between the photoplethysmographic waveform and systemic vascular resistance. J Clin Monit Comput. 2007;21:365–72.CrossRefPubMed Awad AA, Haddadin AS, Tantawy H, Badr TM, Stout RG, Silverman DG, Shelley KH. The relationship between the photoplethysmographic waveform and systemic vascular resistance. J Clin Monit Comput. 2007;21:365–72.CrossRefPubMed
17.
go back to reference Millasseau SC, Guigui FG, Kelly RP, Prasad K, Cockcroft JR, Ritter JM, Chowienczyk PJ. Noninvasive assessment of the digital volume pulse: comparison with the peripheral pressure pulse. Hypertension. 2000;36:952–6.CrossRefPubMed Millasseau SC, Guigui FG, Kelly RP, Prasad K, Cockcroft JR, Ritter JM, Chowienczyk PJ. Noninvasive assessment of the digital volume pulse: comparison with the peripheral pressure pulse. Hypertension. 2000;36:952–6.CrossRefPubMed
18.
go back to reference Chowienczyk PJ, Kelly RP, MacCallum H, Millasseau SC, Andersson TL, Gosling RG, Ritter JM, Anggard EE. Photoplethysmographic assessment of pulse wave reflection: blunted response to endothelium-dependent beta2-adrenergic vasodilation in type II diabetes mellitus. J Am Coll Cardiol. 1999;34:2007–14.CrossRefPubMed Chowienczyk PJ, Kelly RP, MacCallum H, Millasseau SC, Andersson TL, Gosling RG, Ritter JM, Anggard EE. Photoplethysmographic assessment of pulse wave reflection: blunted response to endothelium-dependent beta2-adrenergic vasodilation in type II diabetes mellitus. J Am Coll Cardiol. 1999;34:2007–14.CrossRefPubMed
19.
go back to reference Gu WB, Poon CCY, Zhang YT. A novel parameter from PPG dicrotic notch for estimation of systolic blood pressure using pulse transit time. In Medical Devices and Biosensors. 5th International Summer School and Symposium on. IEEE, 2008. p. 86–8. Gu WB, Poon CCY, Zhang YT. A novel parameter from PPG dicrotic notch for estimation of systolic blood pressure using pulse transit time. In Medical Devices and Biosensors. 5th International Summer School and Symposium on. IEEE, 2008. p. 86–8.
20.
go back to reference Allen J, Murray A, Di Maria C, Newton JL. Chronic fatigue syndrome and impaired peripheral pulse characteristics on orthostasis—a new potential diagnostic biomarker. Physiol Meas. 2012;33(2):231–41.CrossRefPubMed Allen J, Murray A, Di Maria C, Newton JL. Chronic fatigue syndrome and impaired peripheral pulse characteristics on orthostasis—a new potential diagnostic biomarker. Physiol Meas. 2012;33(2):231–41.CrossRefPubMed
21.
go back to reference Shelley KH. Photoplethysmography: beyond the calculation of arterial oxygen saturation and heart rate. Anesth Analg. 2007;105:S31–6.CrossRefPubMed Shelley KH. Photoplethysmography: beyond the calculation of arterial oxygen saturation and heart rate. Anesth Analg. 2007;105:S31–6.CrossRefPubMed
22.
go back to reference Wilkins RW, Halperin MH, Litter J. The effect of the dependent position upon blood flow in the limbs. Circulation. 1950;2:373–9.CrossRefPubMed Wilkins RW, Halperin MH, Litter J. The effect of the dependent position upon blood flow in the limbs. Circulation. 1950;2:373–9.CrossRefPubMed
23.
go back to reference Kammila S, Campbell NRC, Brant R, deJong R, Culleton B. Systematic error in the determination of nocturnal blood pressure dipping status by ambulatory blood pressure monitoring. Blood Press Monit. 2002;7:131–4.CrossRefPubMed Kammila S, Campbell NRC, Brant R, deJong R, Culleton B. Systematic error in the determination of nocturnal blood pressure dipping status by ambulatory blood pressure monitoring. Blood Press Monit. 2002;7:131–4.CrossRefPubMed
24.
go back to reference Gavish B, Gavish L. Blood pressure variation in response to changing arm cuff height cannot be explained solely by the hydrostatic effect. J Hypertens. 2011;29:2099–104.CrossRefPubMed Gavish B, Gavish L. Blood pressure variation in response to changing arm cuff height cannot be explained solely by the hydrostatic effect. J Hypertens. 2011;29:2099–104.CrossRefPubMed
25.
go back to reference Beaconsfield P, Ginsburg J. Effect of changes in limb posture on peripheral blood flow. Circ Res. 1955;3:478–82.CrossRefPubMed Beaconsfield P, Ginsburg J. Effect of changes in limb posture on peripheral blood flow. Circ Res. 1955;3:478–82.CrossRefPubMed
26.
go back to reference Darmanin G, Jaggard M, Hettiaratchy S, Nanchahal J, Jain A. Evaluating optimal superficial limb perfusion at different angles using non-invasive micro-lightguide spectrophotometry. J Plast Reconstr Aesthet Surg. 2013;66:821–6.CrossRefPubMed Darmanin G, Jaggard M, Hettiaratchy S, Nanchahal J, Jain A. Evaluating optimal superficial limb perfusion at different angles using non-invasive micro-lightguide spectrophotometry. J Plast Reconstr Aesthet Surg. 2013;66:821–6.CrossRefPubMed
27.
go back to reference Almond NE, Jones DP, Cooke ED. Noninvasive measurement of the human peripheral circulation: relationship between laser Doppler flowmeter and photoplethysmograph signals from the finger. Angiology. 1988;39:819–29.CrossRefPubMed Almond NE, Jones DP, Cooke ED. Noninvasive measurement of the human peripheral circulation: relationship between laser Doppler flowmeter and photoplethysmograph signals from the finger. Angiology. 1988;39:819–29.CrossRefPubMed
28.
go back to reference Xin S, Hu S, Crabtree VP, Zheng J, Azorin-Peris V, Echiadis A, Smith PR. Investigation of blood pulse PPG signal regulation on toe effect of body posture and lower limb height. J Zhejiang Univ Sci A. 2007;8:916–20.CrossRef Xin S, Hu S, Crabtree VP, Zheng J, Azorin-Peris V, Echiadis A, Smith PR. Investigation of blood pulse PPG signal regulation on toe effect of body posture and lower limb height. J Zhejiang Univ Sci A. 2007;8:916–20.CrossRef
29.
go back to reference Hickey M, Phillips JP, Kyriacou PA. The effect of vascular changes on the photoplethysmographic signal at different hand elevations. Physiol Meas. 2015;36(3):425–40.CrossRefPubMed Hickey M, Phillips JP, Kyriacou PA. The effect of vascular changes on the photoplethysmographic signal at different hand elevations. Physiol Meas. 2015;36(3):425–40.CrossRefPubMed
30.
go back to reference Rybynok V, May JM, Budidha K, Kyriacou PA. Design and development of a novel multi-channel photoplethysmographic research system. In: Proceedings of IEEE Point-of-Care Healthcare Technologies. 2013. p. 267–70. Rybynok V, May JM, Budidha K, Kyriacou PA. Design and development of a novel multi-channel photoplethysmographic research system. In: Proceedings of IEEE Point-of-Care Healthcare Technologies. 2013. p. 267–70.
31.
go back to reference Bahadir Z, Tisdell E, Arce Esquivel AA, Dobrosielski DA, Welsch MA. Influence of venous emptying on the reactive hyperemic blood flow response. Dyn Med. 2007;6:3.CrossRef Bahadir Z, Tisdell E, Arce Esquivel AA, Dobrosielski DA, Welsch MA. Influence of venous emptying on the reactive hyperemic blood flow response. Dyn Med. 2007;6:3.CrossRef
32.
go back to reference Gamble G, Zorn J, Sanders G, MacMahon S, Sharpe N. Estimation of arterial stiffness, compliance and distensibility from M-mode ultrasound measurements of the common carotid artery. Stroke. 1994;25:11–6.CrossRefPubMed Gamble G, Zorn J, Sanders G, MacMahon S, Sharpe N. Estimation of arterial stiffness, compliance and distensibility from M-mode ultrasound measurements of the common carotid artery. Stroke. 1994;25:11–6.CrossRefPubMed
33.
go back to reference Chen HC, Patel V, Wiek J, Rassam SM, Kohner EM. Vessel diameter changes during the cardiac cycle. Eye. 1994;8:97–103.CrossRefPubMed Chen HC, Patel V, Wiek J, Rassam SM, Kohner EM. Vessel diameter changes during the cardiac cycle. Eye. 1994;8:97–103.CrossRefPubMed
34.
go back to reference Wang A, Yang L, Liu C, Cui J, Li Y, Yang X, Zhang S, Zheng D. Athletic differences in the characteristics of the photoplethysmographic pulse shape: effect of maximal oxygen uptake and maximal muscular voluntary contraction. Biomed Res Int. 2015;. doi:10.1155/2015/752570. Wang A, Yang L, Liu C, Cui J, Li Y, Yang X, Zhang S, Zheng D. Athletic differences in the characteristics of the photoplethysmographic pulse shape: effect of maximal oxygen uptake and maximal muscular voluntary contraction. Biomed Res Int. 2015;. doi:10.​1155/​2015/​752570.
35.
go back to reference Burkert A, Scholze A, Tepel M. Noninvasive continuous monitoring of digital pulse waves during hemodialysis. ASAIO J. 2006;52(2):174–9.CrossRefPubMed Burkert A, Scholze A, Tepel M. Noninvasive continuous monitoring of digital pulse waves during hemodialysis. ASAIO J. 2006;52(2):174–9.CrossRefPubMed
36.
go back to reference Hildebrandt W, Herrmann J, Stegemann J. Fluid balance versus blood flow autoregulation in the elevated human limb: the role of venous collapse. Eur J Appl Physiol Occup Physiol. 1994;69:127–31.CrossRefPubMed Hildebrandt W, Herrmann J, Stegemann J. Fluid balance versus blood flow autoregulation in the elevated human limb: the role of venous collapse. Eur J Appl Physiol Occup Physiol. 1994;69:127–31.CrossRefPubMed
37.
go back to reference Midttun M, Sejrsen P. Blood flow rate in arteriovenous anastomoses and capillaries in thumb, first toe, ear lobe, and nose. Clin Physiol. 1996;6:275–89.CrossRef Midttun M, Sejrsen P. Blood flow rate in arteriovenous anastomoses and capillaries in thumb, first toe, ear lobe, and nose. Clin Physiol. 1996;6:275–89.CrossRef
38.
go back to reference Zuther JE. Lymphedema management: the comprehensive guide for practitioners. 3rd ed. Stuttgart: Thieme; 2013. Zuther JE. Lymphedema management: the comprehensive guide for practitioners. 3rd ed. Stuttgart: Thieme; 2013.
Metadata
Title
Investigation of peripheral photoplethysmographic morphology changes induced during a hand-elevation study
Authors
Michelle Hickey
Justin P. Phillips
Panayiotis A. Kyriacou
Publication date
01-10-2016
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 5/2016
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-015-9761-0

Other articles of this Issue 5/2016

Journal of Clinical Monitoring and Computing 5/2016 Go to the issue