Abstract

Background

The design and application of assisted instrumentation for internal fixation of femoral neck fractures with multiple screws are still evolving. A novel guide based on a femoral neck section was designed to improve the accuracy of screw placement, and its efficacy was evaluated.

Methods

A guide based on a femoral neck section was designed for assisted fixation of femoral neck fractures with multiple screws. Femoral specimens from 10 adults (20 femurs) underwent assisted internal fixation for a femoral neck fracture with 3 cannulated screws using the new guide technique or conventional technique. The accuracy of screw orientation and entry point, the accuracy of optimal screw positioning, and drilling attempts, operative time, and fluoroscopy time were recorded.

Results

Among all 20 specimens, 60 screws were inserted successfully. Screw parallelism, operative time, and fluoroscopy time showed no statistical difference between the new guide technique and conventional technique (P > 0.05). The accuracy of optimal screw positioning was determined by the contained screw area ratio, distance between screws, distance from the centre of the femoral neck section, distance between screws and the femoral neck cortex, and Drilling attempts were statistical significantly better (data in the first three were larger and in the latter two was smaller) with the new guide technique, than with conventional technique (P < 0.05).

Conclusions

This new, two-dimensional, fluoroscopy-assisted, percutaneous guide technique enables accurate and optimal screw positioning in internal fixation of femoral neck fractures, compared with conventional technique.
Literature
1.
go back to reference Bhandari M, Tornetta P, Hanson B, Swiontkowski MF. Optimal internal fixation for femoral neck fractures: multiple screws or sliding hip screws? J Orthop Trauma. 2009;23:403–9.CrossRefPubMed Bhandari M, Tornetta P, Hanson B, Swiontkowski MF. Optimal internal fixation for femoral neck fractures: multiple screws or sliding hip screws? J Orthop Trauma. 2009;23:403–9.CrossRefPubMed
2.
go back to reference Luttrell K, Beltran M, Collinge CA. Preoperative decision making in the treatment of high-angle “vertical” femoral neck fractures in young adult patients. An expert opinion survey of the Orthopaedic Trauma Association’s (OTA) menbership. J Orthop Trauma. 2014;28(9):e221–5.CrossRefPubMed Luttrell K, Beltran M, Collinge CA. Preoperative decision making in the treatment of high-angle “vertical” femoral neck fractures in young adult patients. An expert opinion survey of the Orthopaedic Trauma Association’s (OTA) menbership. J Orthop Trauma. 2014;28(9):e221–5.CrossRefPubMed
5.
go back to reference Xia SL, Wang ZP, Wang MH, et al. Self-designed femoral neck guide pin locator for femoral neck fractures. Orthopedics. 2014;37(1):19–23.CrossRef Xia SL, Wang ZP, Wang MH, et al. Self-designed femoral neck guide pin locator for femoral neck fractures. Orthopedics. 2014;37(1):19–23.CrossRef
6.
go back to reference Kendoff D, Hüener T, Citak M, Geerling J, Maier C, Wesemeier F, Krettek C. Implementation of a new navigated parallel drill guide for femoral neck fractures. Comput Aided Surg. 2006;11(6):317–21.CrossRefPubMed Kendoff D, Hüener T, Citak M, Geerling J, Maier C, Wesemeier F, Krettek C. Implementation of a new navigated parallel drill guide for femoral neck fractures. Comput Aided Surg. 2006;11(6):317–21.CrossRefPubMed
8.
go back to reference Hamelinck HKM, Haagmans M, Snoeren MM, Biert J, Vugt ABV, Frolke PM. Safety of computer-assisted surgery for cannulated hip screws. Clin Orthop Relat Res. 2006;455:241–5.CrossRef Hamelinck HKM, Haagmans M, Snoeren MM, Biert J, Vugt ABV, Frolke PM. Safety of computer-assisted surgery for cannulated hip screws. Clin Orthop Relat Res. 2006;455:241–5.CrossRef
9.
go back to reference Wang JQ, Zhao CP, Su YG, Zhou L, Hu L, Wang TM, Wang MY. Computer-assisted navigation systems for insertion of cannulated screws in femoral neck fractures: a comparison of bi-planar robot navigation with optoelectronic navigation in a Synbone hip model trial. Chin Med J. 2011;124(23):3906–11.PubMed Wang JQ, Zhao CP, Su YG, Zhou L, Hu L, Wang TM, Wang MY. Computer-assisted navigation systems for insertion of cannulated screws in femoral neck fractures: a comparison of bi-planar robot navigation with optoelectronic navigation in a Synbone hip model trial. Chin Med J. 2011;124(23):3906–11.PubMed
10.
go back to reference Kate BR. Anteversion versus torsion of the femoral neck. Acta Anat (Basel). 1976;94(3):457–63.CrossRef Kate BR. Anteversion versus torsion of the femoral neck. Acta Anat (Basel). 1976;94(3):457–63.CrossRef
11.
go back to reference Maximilian JH, Andreas P, Anne S, et al. Determination of femoral neck angle and torsion angle utilizing a novel three-dimensional modeling and analytical technology based on CT datasets. PLoS One. 2016;11(3):e0149480.CrossRef Maximilian JH, Andreas P, Anne S, et al. Determination of femoral neck angle and torsion angle utilizing a novel three-dimensional modeling and analytical technology based on CT datasets. PLoS One. 2016;11(3):e0149480.CrossRef
12.
go back to reference Zhu QL, Yuan JF, Zhao LL, et al. Discerning the femoral neck anteversion (FNA) from the torsion angle on 3D CT. China J Orthop Traumatol. 2012;25(10):831–3. Zhu QL, Yuan JF, Zhao LL, et al. Discerning the femoral neck anteversion (FNA) from the torsion angle on 3D CT. China J Orthop Traumatol. 2012;25(10):831–3.
13.
go back to reference Zhang YQ, Chang SM, Huang YG, et al. The femoral neck safe zone: a radiographic simulation study to prevent cortical perforation with multiple screw insertion. J Orthop Trauma. 2015;29(5):178–82.CrossRef Zhang YQ, Chang SM, Huang YG, et al. The femoral neck safe zone: a radiographic simulation study to prevent cortical perforation with multiple screw insertion. J Orthop Trauma. 2015;29(5):178–82.CrossRef
14.
go back to reference Gupta M, Arya RK, Kumar S, Jain VK, Sinha S, Naik AK. Comparative study of multiple cancellous screws versus sliding hip screws in femoral neck fractures of young adults. Chin J Traumatol. 2016;19(4):209–12.CrossRefPubMedPubMedCentral Gupta M, Arya RK, Kumar S, Jain VK, Sinha S, Naik AK. Comparative study of multiple cancellous screws versus sliding hip screws in femoral neck fractures of young adults. Chin J Traumatol. 2016;19(4):209–12.CrossRefPubMedPubMedCentral
15.
go back to reference The FAITH Investigators. Fixation using alternative implants for the treatment of hip fracture (FANTH): design andrationale fora multi-centre randomized trial comparing sliding hip screws and cancellous screws on revision surgery rates and quality of life in the treatment of femoral neck fractures. BMC Musculoskelet Disord. 2014;15:219. https://doi.org/10.1186/1471-2474-15-219.CrossRef The FAITH Investigators. Fixation using alternative implants for the treatment of hip fracture (FANTH): design andrationale fora multi-centre randomized trial comparing sliding hip screws and cancellous screws on revision surgery rates and quality of life in the treatment of femoral neck fractures. BMC Musculoskelet Disord. 2014;15:219. https://​doi.​org/​10.​1186/​1471-2474-15-219.CrossRef
17.
go back to reference Ye Y, Hao J, Mauffrey C, et al. Optimizing stability in femoral neck fracture fixation. Orthopedics. 2015;38(10):625–30.CrossRefPubMed Ye Y, Hao J, Mauffrey C, et al. Optimizing stability in femoral neck fracture fixation. Orthopedics. 2015;38(10):625–30.CrossRefPubMed
18.
go back to reference Gurusamy K, Parker MJ, Rowlands TK. The complications of displaced intracapsular fractures of the hip: the effect of screw positioning and angulation on fracture healing. J Bone Joint Surg Br. 2005;87(5):632–4.CrossRefPubMed Gurusamy K, Parker MJ, Rowlands TK. The complications of displaced intracapsular fractures of the hip: the effect of screw positioning and angulation on fracture healing. J Bone Joint Surg Br. 2005;87(5):632–4.CrossRefPubMed
19.
go back to reference Tan V, Wong KL, Born CT, Harten R, DeLong WG Jr. Two-screw femoral neck fracture fixation: a biomechanical analysis of 2 different configurations. Am J Orthop (Belle Mead NJ). 2007;36(9):481–5. Tan V, Wong KL, Born CT, Harten R, DeLong WG Jr. Two-screw femoral neck fracture fixation: a biomechanical analysis of 2 different configurations. Am J Orthop (Belle Mead NJ). 2007;36(9):481–5.
Metadata
Title
Introduction of a guide based on a femoral neck section for fixation with multiple screws: a cadaveric study
Authors
Qiuliang Zhu
Bin Xu
Jinzhu Lv
Maohua Yan
Publication date
01-12-2018
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2018
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-018-2026-6

Other articles of this Issue 1/2018

BMC Musculoskeletal Disorders 1/2018 Go to the issue