Skip to main content
Top
Published in: Acta Neurochirurgica 6/2015

01-06-2015 | How I Do it - Neurosurgical Techniques

Intraoperative cerebral angiosonography with ultrasound contrast agents: how I do it

Authors: Francesco Prada, Massimiliano Del Bene, Marco Saini, Paolo Ferroli, Francesco DiMeco

Published in: Acta Neurochirurgica | Issue 6/2015

Login to get access

Abstract

Background

Intraoperative vessel visualization is highly desirable, especially when the target is related to or close to main vessels, such as in the skull base and vascular surgery. Contrast-enhanced ultrasound (CEUS) is an imaging technique that allows visualization of tissue perfusion and vascularization through the infusion of purely intravascular ultrasound contrast agents (UCA).

Methods

After cerebral scanning with B-mode ultrasound (US) CEUS is performed, UCA are injected and insonated with low mechanical index US. A UCA-specific harmonic signal is transduced using a contrast-specific algorithm to obtain real-time angiosonography (ASG).

Conclusions

Real-time intraoperative ASG is a rapid, reliable, repeatable method for vessel visualization and evaluation of tissue perfusion.

Key points

ASG permits to assess vessel position, dimension, and relationships; it also allows a qualitative evaluation of flow entity and direction.
ASG shows vessels in depth without the need of their direct exposure, as for fluorescence-guided surgery.
ASG permits to study the entire vascular tree without the necessity to set gain or pulse repetition frequency as in Doppler imaging.
Vessels of interest can be visualized following their entire length across the surgical field, along the arterial, capillary, and venous districts.
ASG scan is repeatable multiple times throughout the operation, and each exam could be recorded as a clip to be visualized at a later stage.
In case of neoplastic lesion, ASG characterizes the perfusion pattern in three phases: arterial, venous, and parenchymal, permitting to visualize afferent and efferent vessels, facilitating the surgical strategy.
During tumor debulking, ASG shows the remaining distance to major vessels, providing information to avoid direct vessel damage.
In tumor and AVM surgery, ASG shows nidus or tumoral remnants that might be covered by healthy tissue, thus not visible on the surface.
In case of aneurysm surgery, post-clipping angiosonographic control confirms proper aneurysm exclusion and distal vessels flow.
Appendix
Available only for authorised users
Literature
1.
go back to reference Holscher T, Ozgur B, Singel S, Wilkening WG, Mattrey RF, Sang H (2007) Intraoperative ultrasound using phase inversion harmonic imaging: first experiences. Neurosurgery 60:382–386, discussion 386–387PubMed Holscher T, Ozgur B, Singel S, Wilkening WG, Mattrey RF, Sang H (2007) Intraoperative ultrasound using phase inversion harmonic imaging: first experiences. Neurosurgery 60:382–386, discussion 386–387PubMed
2.
go back to reference Piscaglia F, Nolsoe C, Dietrich CF, Cosgrove DO, Gilja OH, Bachmann Nielsen M, Albrecht T, Barozzi L, Bertolotto M, Catalano O, Claudon M, Clevert DA, Correas JM, D’Onofrio M, Drudi FM, Eyding J, Giovannini M, Hocke M, Ignee A, Jung EM, Klauser AS, Lassau N, Leen E, Mathis G, Saftoiu A, Seidel G, Sidhu PS, ter Haar G, Timmerman D, Weskott HP (2012) The EFSUMB guidelines and recommendations on the clinical practice of contrast enhanced ultrasound (CEUS): update 2011 on non-hepatic applications. Ultraschall Med 33:33–59, Stuttgart, Germany : 1980CrossRefPubMed Piscaglia F, Nolsoe C, Dietrich CF, Cosgrove DO, Gilja OH, Bachmann Nielsen M, Albrecht T, Barozzi L, Bertolotto M, Catalano O, Claudon M, Clevert DA, Correas JM, D’Onofrio M, Drudi FM, Eyding J, Giovannini M, Hocke M, Ignee A, Jung EM, Klauser AS, Lassau N, Leen E, Mathis G, Saftoiu A, Seidel G, Sidhu PS, ter Haar G, Timmerman D, Weskott HP (2012) The EFSUMB guidelines and recommendations on the clinical practice of contrast enhanced ultrasound (CEUS): update 2011 on non-hepatic applications. Ultraschall Med 33:33–59, Stuttgart, Germany : 1980CrossRefPubMed
3.
go back to reference Prada F, Perin A, Martegani A, Aiani L, Solbiati L, Lamperti M, Casali C, Legnani F, Mattei L, Saladino A, Saini M, DiMeco F (2014) Intraoperative contrast-enhanced ultrasound for brain tumor surgery. Neurosurgery 74:542–552, discussion 552CrossRefPubMed Prada F, Perin A, Martegani A, Aiani L, Solbiati L, Lamperti M, Casali C, Legnani F, Mattei L, Saladino A, Saini M, DiMeco F (2014) Intraoperative contrast-enhanced ultrasound for brain tumor surgery. Neurosurgery 74:542–552, discussion 552CrossRefPubMed
4.
go back to reference Prada F, Del Bene M, Mattei L, Lodigiani L, DeBeni S, Kolev V, Vetrano I, Solbiati L, Sakas G, DiMeco F (2014) Preoperative magnetic resonance and intraoperative ultrasound fusion imaging for real-time neuronavigation in brain tumor surgery. Ultraschall Med (Stuttgart, Germany: 1980) Prada F, Del Bene M, Mattei L, Lodigiani L, DeBeni S, Kolev V, Vetrano I, Solbiati L, Sakas G, DiMeco F (2014) Preoperative magnetic resonance and intraoperative ultrasound fusion imaging for real-time neuronavigation in brain tumor surgery. Ultraschall Med (Stuttgart, Germany: 1980)
5.
go back to reference van Leyen K, Klotzsch C, Harrer JU (2011) Brain tumor imaging with transcranial sonography: state of the art and review of the literature. Ultraschall Med 32:572–581, Stuttgart, Germany: 1980CrossRefPubMed van Leyen K, Klotzsch C, Harrer JU (2011) Brain tumor imaging with transcranial sonography: state of the art and review of the literature. Ultraschall Med 32:572–581, Stuttgart, Germany: 1980CrossRefPubMed
6.
go back to reference Gibbs V, Cole D, Sassano A (2009) Ultrasound physics and technology. Churchill Livingstone Elsevier, London Gibbs V, Cole D, Sassano A (2009) Ultrasound physics and technology. Churchill Livingstone Elsevier, London
7.
go back to reference EMA (2014) SonoVue -EMEA/H/C/000303 -II/0025 EMA (2014) SonoVue -EMEA/H/C/000303 -II/0025
8.
go back to reference Raabe A, Beck J, Seifert V (2005) Technique and image quality of intraoperative indocyanine green angiography during aneurysm surgery using surgical microscope integrated near-infrared video technology. Zentralbl Neurochir 66:1–6, discussion 7–8CrossRefPubMed Raabe A, Beck J, Seifert V (2005) Technique and image quality of intraoperative indocyanine green angiography during aneurysm surgery using surgical microscope integrated near-infrared video technology. Zentralbl Neurochir 66:1–6, discussion 7–8CrossRefPubMed
9.
go back to reference Roessler K, Krawagna M, Dörfler A, Buchfelder M, Ganslandt O (2014) Essentials in intraoperative indocyanine green videoangiography assessment for intracranial aneurysm surgery: conclusions from 295 consecutively clipped aneurysms and review of the literature. Neurosurg Focus 36:E7CrossRefPubMed Roessler K, Krawagna M, Dörfler A, Buchfelder M, Ganslandt O (2014) Essentials in intraoperative indocyanine green videoangiography assessment for intracranial aneurysm surgery: conclusions from 295 consecutively clipped aneurysms and review of the literature. Neurosurg Focus 36:E7CrossRefPubMed
Metadata
Title
Intraoperative cerebral angiosonography with ultrasound contrast agents: how I do it
Authors
Francesco Prada
Massimiliano Del Bene
Marco Saini
Paolo Ferroli
Francesco DiMeco
Publication date
01-06-2015
Publisher
Springer Vienna
Published in
Acta Neurochirurgica / Issue 6/2015
Print ISSN: 0001-6268
Electronic ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-015-2412-x

Other articles of this Issue 6/2015