Abstract

We report a randomised prospective study comparing two implants, the Gamma trochanteric nail and the ACE trochanteric nail, in the treatment of intertrochanteric femoral fractures in the elderly. One hundred and twelve patients were randomised on admission into two treatment groups. Fifty-six patients were treated with Gamma nail implants, and 56 were treated with ACE trochanteric nail. The average age of these patients was 78 years. Twenty fractures were stable and 92 unstable. The mean follow-up time was 8 months (6 –12). Regular clinical and radiological review was done 1, 3 and 6 months postoperatively. Operation time, fluoroscopy time, blood transfusion and complications were recorded. The mobility score was used to assess the pre-injury and postoperative mobility status. All the patients were treated within 36 h of their accident. There were no complications during surgery. All the patients were mobilised in the first 24 h postoperatively, regardless of the fracture type, and weight bearing was permitted as tolerated. Union of the fracture was achieved in all patients. There was no statistically significant difference between the two groups with regard to the studied parameters. There was no mechanical failure of the implants despite the early patient mobilisation. Early operation and early mobilisation resulted in a good functional outcome in all patients. Both the trochanteric gamma nail and ACE trochanteric nail provide effective methods of treatment for intertrochanteric fractures in elderly patients.
Literature
1.
go back to reference Doppelt SH (1980) The sliding compression screw-Today’s best answer for stabilization of intertrochanteric hip fractures. Orthop Clin North Am 11:507–523PubMed Doppelt SH (1980) The sliding compression screw-Today’s best answer for stabilization of intertrochanteric hip fractures. Orthop Clin North Am 11:507–523PubMed
2.
go back to reference O’Brien PJ, Meek RN, Blachut PA et al (1995) Fixation of intertrochanteric hip fractures: gamma nail versus dynamic hip screw. A randomized, prospective study. Can J Surg 38:516–520PubMed O’Brien PJ, Meek RN, Blachut PA et al (1995) Fixation of intertrochanteric hip fractures: gamma nail versus dynamic hip screw. A randomized, prospective study. Can J Surg 38:516–520PubMed
3.
go back to reference Radford PJ, Needoff M, Webb JK (1993) A prospective randomized comparison of the dynamic hip screw and the Gamma locking nail. J Bone Joint Surg Br 75B:789–793 Radford PJ, Needoff M, Webb JK (1993) A prospective randomized comparison of the dynamic hip screw and the Gamma locking nail. J Bone Joint Surg Br 75B:789–793
4.
go back to reference Wolfgang GL, Bryant MH, O’Neill JP (1982) Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation. Clin Orthop 163:148–158PubMed Wolfgang GL, Bryant MH, O’Neill JP (1982) Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation. Clin Orthop 163:148–158PubMed
5.
6.
go back to reference Rebuzzi E, Pannone A, Schiavetti S, Santoriello P, de Nicola U, Fancellu G, Cau P, Gulli S, Dordolin P, Maniscalco P, Morici F, Commessatti M, Pozzi-Mucelli M, Maiorana CS, Bassini F (2002) IMHS clinical experience in the treatment of peritrochanteric fractures. The results of a multicentric Italian study of 981 cases. Injury. Jun;33(5):407–412PubMedCrossRef Rebuzzi E, Pannone A, Schiavetti S, Santoriello P, de Nicola U, Fancellu G, Cau P, Gulli S, Dordolin P, Maniscalco P, Morici F, Commessatti M, Pozzi-Mucelli M, Maiorana CS, Bassini F (2002) IMHS clinical experience in the treatment of peritrochanteric fractures. The results of a multicentric Italian study of 981 cases. Injury. Jun;33(5):407–412PubMedCrossRef
7.
go back to reference Sadowski C, Lubbeke A, Saudan M et al (2002) Treatment of reverse and transverse intertrochanteric fractures with use of an intramedullary nail or 95 degrees screw-plate: a prospective, randomized study. J Bone Joint Surg Am 84A:372–381 Sadowski C, Lubbeke A, Saudan M et al (2002) Treatment of reverse and transverse intertrochanteric fractures with use of an intramedullary nail or 95 degrees screw-plate: a prospective, randomized study. J Bone Joint Surg Am 84A:372–381
8.
go back to reference Madsen JE, Naess L, Aune AK, Alho A, Ekeland A, Stromsoe K (1998) Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw. J Orthop Trauma 12:241–248PubMedCrossRef Madsen JE, Naess L, Aune AK, Alho A, Ekeland A, Stromsoe K (1998) Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw. J Orthop Trauma 12:241–248PubMedCrossRef
9.
go back to reference Butt MS, Krikler SJ, Nafie S, Ali MS (1995) Comparison of dynamic hip screw and gamma nail: a prospective, randomized, controlled trial. Injury 26:615–618PubMedCrossRef Butt MS, Krikler SJ, Nafie S, Ali MS (1995) Comparison of dynamic hip screw and gamma nail: a prospective, randomized, controlled trial. Injury 26:615–618PubMedCrossRef
10.
go back to reference Fogagnolo F, Kfuri M Jr, Paccola CA (2004) Intramedullary fixation of pertrochanteric hip fractures with the short AO-ASIF proximal femoral nail. Arch Orthop Trauma Surg 124(1):31–7. Epub 2003 Sep, JanPubMedCrossRef Fogagnolo F, Kfuri M Jr, Paccola CA (2004) Intramedullary fixation of pertrochanteric hip fractures with the short AO-ASIF proximal femoral nail. Arch Orthop Trauma Surg 124(1):31–7. Epub 2003 Sep, JanPubMedCrossRef
11.
go back to reference Harrington P, Nihal A, Singhania AK, Howell FR (2002) Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly. Injury 33(1):23–28PubMedCrossRef Harrington P, Nihal A, Singhania AK, Howell FR (2002) Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly. Injury 33(1):23–28PubMedCrossRef
12.
13.
go back to reference American Society of Anesthesiologists (1963) New classification of physical status. Anesthesiology 24:111CrossRef American Society of Anesthesiologists (1963) New classification of physical status. Anesthesiology 24:111CrossRef
14.
go back to reference Parker MJ, Palmer CR (1993) A new mobility score for predicting mortality after hip fracture. J Bone Joint Surg Br 75:797–798PubMed Parker MJ, Palmer CR (1993) A new mobility score for predicting mortality after hip fracture. J Bone Joint Surg Br 75:797–798PubMed
15.
go back to reference Doppelt SH (1980) The sliding compression screw-Today’s best answer for stabilization of intertrochanteric hip fractures. Orthop Clin North Am 11:507–523PubMed Doppelt SH (1980) The sliding compression screw-Today’s best answer for stabilization of intertrochanteric hip fractures. Orthop Clin North Am 11:507–523PubMed
16.
go back to reference Sadowski C, Lubbeke A, Saudan M et al (2002) Treatment of reverse and transverse intertrochanteric fractures with use of an intramedullary nail or 95 degrees screw-plate: a prospective, randomized study. J Bone Joint Surg Am 84A:372–381 Sadowski C, Lubbeke A, Saudan M et al (2002) Treatment of reverse and transverse intertrochanteric fractures with use of an intramedullary nail or 95 degrees screw-plate: a prospective, randomized study. J Bone Joint Surg Am 84A:372–381
17.
go back to reference Adams CI, Robinson CM, Court-Brown CM, McQueen MM (2001) Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur. J Orthop Trauma 15(6):394–400PubMedCrossRef Adams CI, Robinson CM, Court-Brown CM, McQueen MM (2001) Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur. J Orthop Trauma 15(6):394–400PubMedCrossRef
18.
go back to reference Hardy DCR, Descamps PY, Krallis P, Fabeck L, Smets P, Bertens CL, Delince PE (1998) Use of an intramedullary hip screw compared with a compression hip screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients. J Bone Joint Surg Am 80:618–630PubMed Hardy DCR, Descamps PY, Krallis P, Fabeck L, Smets P, Bertens CL, Delince PE (1998) Use of an intramedullary hip screw compared with a compression hip screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients. J Bone Joint Surg Am 80:618–630PubMed
19.
go back to reference Baumgaertner MR, Curtin SL, Lindskog DM (1998) Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures. Clin Orthop Relat Res (348):87–94 MarPubMedCrossRef Baumgaertner MR, Curtin SL, Lindskog DM (1998) Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures. Clin Orthop Relat Res (348):87–94 MarPubMedCrossRef
20.
go back to reference Zickel RE (1967) A new fixation device for subtrochanteric fractures of the femur: preliminary report. Clin Orthop 54:115–123PubMed Zickel RE (1967) A new fixation device for subtrochanteric fractures of the femur: preliminary report. Clin Orthop 54:115–123PubMed
21.
go back to reference Haynes RC, Poll RG, Miles AW et al (1997) Failure of femoral head fixation: a cadaveric analysis of lag screw cut-out with the Gamma locking nail and AO dynamic hip screw. Injury 28:337–341PubMedCrossRef Haynes RC, Poll RG, Miles AW et al (1997) Failure of femoral head fixation: a cadaveric analysis of lag screw cut-out with the Gamma locking nail and AO dynamic hip screw. Injury 28:337–341PubMedCrossRef
22.
go back to reference Shaw JA, Wilson S (1993) Internal fixation of proximal femur fractures: a biomechanical comparison of the Gamma locking nail and the omega compression hip screw. Orthop Rev 22:61–68PubMed Shaw JA, Wilson S (1993) Internal fixation of proximal femur fractures: a biomechanical comparison of the Gamma locking nail and the omega compression hip screw. Orthop Rev 22:61–68PubMed
23.
go back to reference Lacroix H, Arwert H, Snijders CJ et al (1995) Prevention of fracture at the distal locking site of the Gamma nail: a biomechanical study. J Bone Joint Surg Br 77B:274–276 Lacroix H, Arwert H, Snijders CJ et al (1995) Prevention of fracture at the distal locking site of the Gamma nail: a biomechanical study. J Bone Joint Surg Br 77B:274–276
24.
go back to reference Siegmeth AW, Gurusamy K, Parker MJ (2005) Delay to surgery prolongs hospital stay in patients with fractures of the proximal femur. J Bone Joint Surg Br 87(8):1123–1126 AugPubMedCrossRef Siegmeth AW, Gurusamy K, Parker MJ (2005) Delay to surgery prolongs hospital stay in patients with fractures of the proximal femur. J Bone Joint Surg Br 87(8):1123–1126 AugPubMedCrossRef
25.
go back to reference Perez JV, Warwick DJ, Case CP, Bannister GC (1995) Death after proximal femoral fracture-an autopsy study. Injury 26:237–240PubMedCrossRef Perez JV, Warwick DJ, Case CP, Bannister GC (1995) Death after proximal femoral fracture-an autopsy study. Injury 26:237–240PubMedCrossRef
Metadata
Title
Intramedullary fixation of intertrochanteric hip fractures: a comparison of two implant designs
Authors
Nicolas E. Efstathopoulos
Vassilios S. Nikolaou
John T. Lazarettos
Publication date
01-02-2007
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 1/2007
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-006-0128-5

Other articles of this Issue 1/2007

International Orthopaedics 1/2007 Go to the issue