Abstract

Background

To study the feasibility of utilizing intracortical electroencephalography (ICE) including quantitative EEG (qEEG) analysis for the detection of vasospasm in five consecutive poor-grade SAH patients.

Methods

Intracortical electroencephalography (ICE) was obtained via a single miniature parenchymal 8-contact depth electrode placed at the bedside. Quantitative EEG parameters, calculated on surface EEG and ICE, included alpha/delta ratio (ADR), mean amplitude, suppression percent, and total power. Percent changes between averaged values over 4–6 h of baseline EEG and EEG prior to angiography were calculated. The entire continuous qEEG recording for each patient was then reviewed to determine optimal automated alarm criteria.

Results

ICE ADR was the most accurate for predicting angiographic vasospasm (5/5). ICE ADR decreased between baseline and follow-up by 42% (from 0.56 ± 0.07 to 0.32 ± 0.03) for those with vasospasm (N = 3) compared to 17% (0.62 ± 0.06 to 0.51 ± 0.03) for those without (N = 2). A sustained decrease in the ICE ADR from baseline (>25% for ≥4 h) occurred in all three patients with angiographically confirmed vasospasm and not in the two without; this decline occurred 1–3 days prior to angiographic confirmation.

Conclusions

Intracortical EEG is promising for detecting ischemia from vasospasm in poor-grade SAH patients, may be superior to scalp EEG, and allow automated detection, particularly using the ADR. Larger studies are needed to better define the effectiveness of this approach.
Literature
1.
go back to reference Kassell NF, Boarini DJ. Cerebral ischemia in the aneurysm patient. Clin Neurosurg. 1982;29:657–65.PubMed Kassell NF, Boarini DJ. Cerebral ischemia in the aneurysm patient. Clin Neurosurg. 1982;29:657–65.PubMed
2.
go back to reference Komotar RJ, Zacharia BE, Valhora R, Mocco J, Connolly ES Jr. Advances in vasospasm treatment and prevention. J Neurol Sci. 2007;261(1–2):134–42.CrossRefPubMed Komotar RJ, Zacharia BE, Valhora R, Mocco J, Connolly ES Jr. Advances in vasospasm treatment and prevention. J Neurol Sci. 2007;261(1–2):134–42.CrossRefPubMed
3.
go back to reference Claassen J, Hirsch LJ, Kreiter KT, Du EY, Connolly ES, Emerson RG, et al. Quantitative continuous EEG for detecting delayed cerebral ischemia in patients with poor-grade subarachnoid hemorrhage. Clin Neurophysiol. 2004;115(12):2699–710.CrossRefPubMed Claassen J, Hirsch LJ, Kreiter KT, Du EY, Connolly ES, Emerson RG, et al. Quantitative continuous EEG for detecting delayed cerebral ischemia in patients with poor-grade subarachnoid hemorrhage. Clin Neurophysiol. 2004;115(12):2699–710.CrossRefPubMed
4.
go back to reference Labar DR, Fisch BJ, Pedley TA, Fink ME, Solomon RA. Quantitative EEG monitoring for patients with subarachnoid hemorrhage. Electroencephalogr Clin Neurophysiol. 1991;78(5):325–32.CrossRefPubMed Labar DR, Fisch BJ, Pedley TA, Fink ME, Solomon RA. Quantitative EEG monitoring for patients with subarachnoid hemorrhage. Electroencephalogr Clin Neurophysiol. 1991;78(5):325–32.CrossRefPubMed
5.
go back to reference Vespa PM, Nuwer MR, Juhasz C, Alexander M, Nenov V, Martin N, et al. Early detection of vasospasm after acute subarachnoid hemorrhage using continuous EEG ICU monitoring. Electroencephalogr Clin Neurophysiol. 1997;103(6):607–15.CrossRefPubMed Vespa PM, Nuwer MR, Juhasz C, Alexander M, Nenov V, Martin N, et al. Early detection of vasospasm after acute subarachnoid hemorrhage using continuous EEG ICU monitoring. Electroencephalogr Clin Neurophysiol. 1997;103(6):607–15.CrossRefPubMed
6.
go back to reference Young GB, Campbell VC. EEG monitoring in the intensive care unit: pitfalls and caveats. J Clin Neurophysiol. 1999;16(1):40–5.CrossRefPubMed Young GB, Campbell VC. EEG monitoring in the intensive care unit: pitfalls and caveats. J Clin Neurophysiol. 1999;16(1):40–5.CrossRefPubMed
7.
go back to reference Waziri A, Claassen J, Stuart RM, Arif H, Schmidt JM, Mayer SA, Badjatia N, Kull LR, Connolly ES, Emerson RG, Hirsch LJ. Intracortical electroencephalography in acute brain injury. Ann Neurol. 2009;66(3):366–77.CrossRefPubMed Waziri A, Claassen J, Stuart RM, Arif H, Schmidt JM, Mayer SA, Badjatia N, Kull LR, Connolly ES, Emerson RG, Hirsch LJ. Intracortical electroencephalography in acute brain injury. Ann Neurol. 2009;66(3):366–77.CrossRefPubMed
Metadata
Title
Intracortical EEG for the Detection of Vasospasm in Patients with Poor-Grade Subarachnoid Hemorrhage
Authors
R. Morgan Stuart
Allen Waziri
David Weintraub
Michael J. Schmidt
Luis Fernandez
Raimund Helbok
Pedro Kurtz
Kiwon Lee
Neeraj Badjatia
Ron Emerson
Stephan A. Mayer
E. Sander Connolly
Lawrence J. Hirsch
Jan Claassen
Publication date
01-12-2010
Publisher
Humana Press Inc
Published in
Neurocritical Care / Issue 3/2010
Print ISSN: 1541-6933
Electronic ISSN: 1556-0961
DOI
https://doi.org/10.1007/s12028-010-9414-6

Other articles of this Issue 3/2010

Neurocritical Care 3/2010 Go to the issue