Skip to main content
Top
Published in: Journal of Cardiovascular Magnetic Resonance 1/2014

Open Access 01-12-2014 | Research

Intercentre reproducibility of cardiac apparent diffusion coefficient and fractional anisotropy in healthy volunteers

Authors: Elizabeth M Tunnicliffe, Andrew D Scott, Pedro Ferreira, Rina Ariga, Laura-Ann McGill, Sonia Nielles-Vallespin, Stefan Neubauer, Dudley J Pennell, Matthew D Robson, David N Firmin

Published in: Journal of Cardiovascular Magnetic Resonance | Issue 1/2014

Login to get access

Abstract

Background

Diffusion tensor cardiac magnetic resonance (DT-CMR) enables probing of the microarchitecture of the myocardium, but the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) reported in healthy volunteers have been inconsistent. The aim of this study was to validate a stimulated-echo diffusion sequence using phantoms, and to assess the intercentre reproducibility of in-vivo diffusion measures using the sequence.

Methods and results

A stimulated-echo, cardiac-gated DT-CMR sequence with a reduced-field-of-view, single-shot EPI readout was used at two centres with 3 T MRI scanners. Four alkane phantoms with known diffusivities were scanned at a single centre using a stimulated echo sequence and a spin-echo Stejskal-Tanner diffusion sequence. The median (maximum, minimum) difference between the DT-CMR sequence and Stejskal-Tanner sequence was 0.01 (0.04, 0.0006) × 10-3 mm2/s (2%), and between the DT-CMR sequence and literature diffusivities was 0.02 (0.05, 0.006) × 10-3 mm2/s (4%).
The same ten healthy volunteers were scanned using the DT-CMR sequence at the two centres less than seven days apart. Average ADC and FA were calculated in a single mid-ventricular, short axis slice. Intercentre differences were tested for statistical significance at the p < 0.05 level using paired t-tests. The mean ADC ± standard deviation for all subjects averaged over both centres was 1.10 ± 0.06 × 10-3 mm2/s in systole and 1.20 ± 0.09 × 10-3 mm2/s in diastole; FA was 0.41 ± 0.04 in systole and 0.54 ± 0.03 in diastole. With similarly-drawn regions-of-interest, systolic ADC (difference 0.05 × 10-3 mm2/s), systolic FA (difference 0.003) and diastolic FA (difference 0.01) were not statistically significantly different between centres (p > 0.05), and only the diastolic ADC showed a statistically significant, but numerically small, difference of 0.07 × 10-3 mm2/s (p = 0.047). The intercentre, intrasubject coefficients of variance were: systolic ADC 7%, FA 6%; diastolic ADC 7%, FA 3%.

Conclusions

This is the first study to demonstrate the accuracy of a stimulated-echo DT-CMR sequence in phantoms, and demonstrates the feasibility of obtaining reproducible ADC and FA in healthy volunteers at separate centres with well-matched sequences and processing.
Appendix
Available only for authorised users
Literature
1.
go back to reference Tseng W-YI, Dou J, Reese TG, Wedeen VJ: Imaging myocardial fiber disarray and intramural strain hypokinesis in hypertrophic cardiomyopathy with MRI. J Magn Reson Imaging. 2008, 23: 1-8.CrossRef Tseng W-YI, Dou J, Reese TG, Wedeen VJ: Imaging myocardial fiber disarray and intramural strain hypokinesis in hypertrophic cardiomyopathy with MRI. J Magn Reson Imaging. 2008, 23: 1-8.CrossRef
2.
go back to reference Wu M-T, Su M-YM, Huang Y-L, Chiou K-R, Yang P, Pan H-B, Reese TG, Wedeen VJ, Tseng W-YI: Sequential changes of myocardial microstructure in patients postmyocardial infarction by diffusion-tensor cardiac MR: correlation with left ventricular structure and function. Circ Cardiovasc Imaging. 2009, 2: 32-40. 10.1161/CIRCIMAGING.108.778902.CrossRefPubMed Wu M-T, Su M-YM, Huang Y-L, Chiou K-R, Yang P, Pan H-B, Reese TG, Wedeen VJ, Tseng W-YI: Sequential changes of myocardial microstructure in patients postmyocardial infarction by diffusion-tensor cardiac MR: correlation with left ventricular structure and function. Circ Cardiovasc Imaging. 2009, 2: 32-40. 10.1161/CIRCIMAGING.108.778902.CrossRefPubMed
3.
go back to reference Stejskal EO, Tanner JE: Spin diffusion measurements: spin echoes in the presence of a time-dependent field gradient. J Chem Phys. 1965, 42: 288-10.1063/1.1695690.CrossRef Stejskal EO, Tanner JE: Spin diffusion measurements: spin echoes in the presence of a time-dependent field gradient. J Chem Phys. 1965, 42: 288-10.1063/1.1695690.CrossRef
4.
go back to reference Gamper U, Boesiger P, Kozerke S: Diffusion imaging of the in vivo heart using spin echoes–considerations on bulk motion sensitivity. Magn Reson Med. 2007, 57: 331-7. 10.1002/mrm.21127.CrossRefPubMed Gamper U, Boesiger P, Kozerke S: Diffusion imaging of the in vivo heart using spin echoes–considerations on bulk motion sensitivity. Magn Reson Med. 2007, 57: 331-7. 10.1002/mrm.21127.CrossRefPubMed
5.
go back to reference Nguyen C, Fan Z, Sharif B, He Y, Dharmakumar R, Berman DS, Li D: In vivo three-dimensional high resolution cardiac diffusion-weighted MRI: a motion compensated diffusion-prepared balanced steady-state free precession approach. Magn Reson Med. 2013, In press. doi: 10.1002/mrm.25038 Nguyen C, Fan Z, Sharif B, He Y, Dharmakumar R, Berman DS, Li D: In vivo three-dimensional high resolution cardiac diffusion-weighted MRI: a motion compensated diffusion-prepared balanced steady-state free precession approach. Magn Reson Med. 2013, In press. doi: 10.1002/mrm.25038
6.
go back to reference Rapacchi S, Wen H, Viallon M, Grenier D, Kellman P, Croisille P, Pai VM: Low b-value diffusion-weighted cardiac magnetic resonance imaging: initial results in humans using an optimal time-window imaging approach. Invest Radiol. 2011, 46: 751-8. 10.1097/RLI.0b013e31822438e8.PubMedCentralCrossRefPubMed Rapacchi S, Wen H, Viallon M, Grenier D, Kellman P, Croisille P, Pai VM: Low b-value diffusion-weighted cardiac magnetic resonance imaging: initial results in humans using an optimal time-window imaging approach. Invest Radiol. 2011, 46: 751-8. 10.1097/RLI.0b013e31822438e8.PubMedCentralCrossRefPubMed
7.
go back to reference Edelman RR, Gaa J, Wedeen VJ, Loh E, Hare JM, Prasad P, Li W: In vivo measurement of water diffusion in the human heart. Magn Reson Med. 1994, 32: 423-8. 10.1002/mrm.1910320320.CrossRefPubMed Edelman RR, Gaa J, Wedeen VJ, Loh E, Hare JM, Prasad P, Li W: In vivo measurement of water diffusion in the human heart. Magn Reson Med. 1994, 32: 423-8. 10.1002/mrm.1910320320.CrossRefPubMed
8.
go back to reference Reese TG, Weisskoff RM, Smith RN, Rosen BR, Dinsmore RE, Wedeen VJ: Imaging myocardial fiber architecture in vivo with magnetic resonance. Magn Reson Med. 1995, 34: 786-91. 10.1002/mrm.1910340603.CrossRefPubMed Reese TG, Weisskoff RM, Smith RN, Rosen BR, Dinsmore RE, Wedeen VJ: Imaging myocardial fiber architecture in vivo with magnetic resonance. Magn Reson Med. 1995, 34: 786-91. 10.1002/mrm.1910340603.CrossRefPubMed
9.
go back to reference Tseng W-YI, Reese TG, Weisskoff RM, Wedeen VJ: Cardiac diffusion tensor MRI in vivo without strain correction. Magn Reson Med. 1999, 42: 393-403. 10.1002/(SICI)1522-2594(199908)42:2<393::AID-MRM22>3.0.CO;2-F.CrossRefPubMed Tseng W-YI, Reese TG, Weisskoff RM, Wedeen VJ: Cardiac diffusion tensor MRI in vivo without strain correction. Magn Reson Med. 1999, 42: 393-403. 10.1002/(SICI)1522-2594(199908)42:2<393::AID-MRM22>3.0.CO;2-F.CrossRefPubMed
10.
go back to reference Dou J, Reese TG, Tseng W-YI, Wedeen VJ: Cardiac diffusion MRI without motion effects. Magn Reson Med. 2002, 48: 105-14. 10.1002/mrm.10188.CrossRefPubMed Dou J, Reese TG, Tseng W-YI, Wedeen VJ: Cardiac diffusion MRI without motion effects. Magn Reson Med. 2002, 48: 105-14. 10.1002/mrm.10188.CrossRefPubMed
11.
go back to reference Wu M-T, Tseng W-YI, Su M-YM, Liu C-P, Chiou K-R, Wedeen VJ, Reese TG, Yang C-F: Diffusion tensor magnetic resonance imaging mapping the fiber architecture remodeling in human myocardium after infarction: correlation with viability and wall motion. Circulation. 2006, 114: 1036-45. 10.1161/CIRCULATIONAHA.105.545863.CrossRefPubMed Wu M-T, Tseng W-YI, Su M-YM, Liu C-P, Chiou K-R, Wedeen VJ, Reese TG, Yang C-F: Diffusion tensor magnetic resonance imaging mapping the fiber architecture remodeling in human myocardium after infarction: correlation with viability and wall motion. Circulation. 2006, 114: 1036-45. 10.1161/CIRCULATIONAHA.105.545863.CrossRefPubMed
12.
go back to reference Nielles-Vallespin S, Mekkaoui C, Gatehouse P, Reese TG, Keegan J, Ferreira PF, Collins S, Speier P, Feiweier T, de Silva R, Jackowski MP, Pennell DJ, Sosnovik DE, Firmin D: In vivo diffusion tensor MRI of the human heart: reproducibility of breath-hold and navigator-based approaches. Magn Reson Med. 2013, 70: 454-65. 10.1002/mrm.24488.CrossRefPubMed Nielles-Vallespin S, Mekkaoui C, Gatehouse P, Reese TG, Keegan J, Ferreira PF, Collins S, Speier P, Feiweier T, de Silva R, Jackowski MP, Pennell DJ, Sosnovik DE, Firmin D: In vivo diffusion tensor MRI of the human heart: reproducibility of breath-hold and navigator-based approaches. Magn Reson Med. 2013, 70: 454-65. 10.1002/mrm.24488.CrossRefPubMed
13.
go back to reference Tofts PS, Lloyd D, Clark CA, Barker GJ, Parker GJM, McConville P, Baldock C, Pope JM: Test liquids for quantitative MRI measurements of self-diffusion coefficient in vivo. Magn Reson Med. 2000, 43: 368-74. 10.1002/(SICI)1522-2594(200003)43:3<368::AID-MRM8>3.0.CO;2-B.CrossRefPubMed Tofts PS, Lloyd D, Clark CA, Barker GJ, Parker GJM, McConville P, Baldock C, Pope JM: Test liquids for quantitative MRI measurements of self-diffusion coefficient in vivo. Magn Reson Med. 2000, 43: 368-74. 10.1002/(SICI)1522-2594(200003)43:3<368::AID-MRM8>3.0.CO;2-B.CrossRefPubMed
14.
go back to reference Guizar-Sicairos M, Thurman ST, Fienup JR: Efficient subpixel image registration algorithms. Opt Lett. 2008, 33: 156-8. 10.1364/OL.33.000156.CrossRefPubMed Guizar-Sicairos M, Thurman ST, Fienup JR: Efficient subpixel image registration algorithms. Opt Lett. 2008, 33: 156-8. 10.1364/OL.33.000156.CrossRefPubMed
15.
go back to reference Kingsley PB: Introduction to diffusion tensor imaging mathematics: Part III. Tensor calculation, noise, simulations, and optimization. Conc Magn Reson A. 2006, 28A (2): 155-79. 10.1002/cmr.a.20050.CrossRef Kingsley PB: Introduction to diffusion tensor imaging mathematics: Part III. Tensor calculation, noise, simulations, and optimization. Conc Magn Reson A. 2006, 28A (2): 155-79. 10.1002/cmr.a.20050.CrossRef
16.
go back to reference Basser PJ, Pierpaoli C: Microstructural and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI. J Magn Reson B. 1996, 111: 209-19. 10.1006/jmrb.1996.0086.CrossRefPubMed Basser PJ, Pierpaoli C: Microstructural and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI. J Magn Reson B. 1996, 111: 209-19. 10.1006/jmrb.1996.0086.CrossRefPubMed
17.
go back to reference Lombaert H, Peyrat J, Croisille P, Rapacchi S, Fanton L, Cheriet F, Clarysse P, Magnin I, Delingette H, Ayache N: Human atlas of the cardiac fiber architecture: study on a healthy population. IEEE Trans Med Imaging. 2012, 31: 1436-47.CrossRefPubMed Lombaert H, Peyrat J, Croisille P, Rapacchi S, Fanton L, Cheriet F, Clarysse P, Magnin I, Delingette H, Ayache N: Human atlas of the cardiac fiber architecture: study on a healthy population. IEEE Trans Med Imaging. 2012, 31: 1436-47.CrossRefPubMed
18.
go back to reference Altman DG, Bland JM: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986, 327: 307-10. 10.1016/S0140-6736(86)90837-8.CrossRef Altman DG, Bland JM: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986, 327: 307-10. 10.1016/S0140-6736(86)90837-8.CrossRef
19.
go back to reference Pocock SJ: Clinical trials with multiple outcomes: a statistical perspective on their design, analysis and interpretation. Control Clin Trials. 1997, 18: 546-9. 10.1016/S0197-2456(97)82056-9.CrossRef Pocock SJ: Clinical trials with multiple outcomes: a statistical perspective on their design, analysis and interpretation. Control Clin Trials. 1997, 18: 546-9. 10.1016/S0197-2456(97)82056-9.CrossRef
20.
go back to reference Laubach HJ, Jakob PM, Loevblad KO, Baird AE, Bovo MP, Edelman RR, Warach S: A phantom for diffusion-weighted imaging of acute stroke. J Magn Reson Imaging. 1998, 8: 1349-54. 10.1002/jmri.1880080627.CrossRefPubMed Laubach HJ, Jakob PM, Loevblad KO, Baird AE, Bovo MP, Edelman RR, Warach S: A phantom for diffusion-weighted imaging of acute stroke. J Magn Reson Imaging. 1998, 8: 1349-54. 10.1002/jmri.1880080627.CrossRefPubMed
21.
go back to reference Davies E, Huang Y, Harper JB, Hook JM, Thomas DS, Burgar IM, Lillford PJ: Dynamics of water in agar gels studied using low and high resolution 1H NMR spectroscopy. Int J Food Sci Technol. 2010, 45: 2502-7. 10.1111/j.1365-2621.2010.02448.x.CrossRef Davies E, Huang Y, Harper JB, Hook JM, Thomas DS, Burgar IM, Lillford PJ: Dynamics of water in agar gels studied using low and high resolution 1H NMR spectroscopy. Int J Food Sci Technol. 2010, 45: 2502-7. 10.1111/j.1365-2621.2010.02448.x.CrossRef
22.
go back to reference McGill L-A, Ismail TF, Nielles-Vallespin S, Ferreira P, Scott AD, Roughton M, Kilner PJ, Ho SY, McCarthy KP, Gatehouse PD, de Silva R, Speier P, Feiweier T, Mekkaoui C, Sosnovik DE, Prasad SK, Firmin DN, Pennell DJ: Reproducibility of in-vivo diffusion tensor cardiovascular magnetic resonance in hypertrophic cardiomyopathy. J Cardiovasc Magn Reson. 2012, 14: 86-10.1186/1532-429X-14-86.PubMedCentralCrossRefPubMed McGill L-A, Ismail TF, Nielles-Vallespin S, Ferreira P, Scott AD, Roughton M, Kilner PJ, Ho SY, McCarthy KP, Gatehouse PD, de Silva R, Speier P, Feiweier T, Mekkaoui C, Sosnovik DE, Prasad SK, Firmin DN, Pennell DJ: Reproducibility of in-vivo diffusion tensor cardiovascular magnetic resonance in hypertrophic cardiomyopathy. J Cardiovasc Magn Reson. 2012, 14: 86-10.1186/1532-429X-14-86.PubMedCentralCrossRefPubMed
23.
go back to reference Nielles-Vallespin S, Mekkaoui C, Gatehouse P, Reese TG, Keegan J, Ferreira PF, Collins S, Speier P, Feiweier T, de Silva R, Jackowski MP, Pennell DJ, Sosnovik DE, Firmin D: Erratum: In vivo diffusion tensor MRI of the human heart: reproducibility of breath-hold and navigator-based approaches. Magn Reson Med. 2014, In press. doi: 10.1002/mrm.25237 Nielles-Vallespin S, Mekkaoui C, Gatehouse P, Reese TG, Keegan J, Ferreira PF, Collins S, Speier P, Feiweier T, de Silva R, Jackowski MP, Pennell DJ, Sosnovik DE, Firmin D: Erratum: In vivo diffusion tensor MRI of the human heart: reproducibility of breath-hold and navigator-based approaches. Magn Reson Med. 2014, In press. doi: 10.1002/mrm.25237
24.
go back to reference Jones DK, Basser PJ: “Squashing peanuts and smashing pumpkins”: how noise distorts diffusion-weighted MR data. Magn Reson Med. 2004, 52: 979-93. 10.1002/mrm.20283.CrossRefPubMed Jones DK, Basser PJ: “Squashing peanuts and smashing pumpkins”: how noise distorts diffusion-weighted MR data. Magn Reson Med. 2004, 52: 979-93. 10.1002/mrm.20283.CrossRefPubMed
25.
go back to reference Constantinides CD, Atalar E, McVeigh ER: Signal-to-noise measurements in magnitude images from NMR phased arrays. Magn Reson Med. 1997, 38: 852-7. 10.1002/mrm.1910380524.PubMedCentralCrossRefPubMed Constantinides CD, Atalar E, McVeigh ER: Signal-to-noise measurements in magnitude images from NMR phased arrays. Magn Reson Med. 1997, 38: 852-7. 10.1002/mrm.1910380524.PubMedCentralCrossRefPubMed
Metadata
Title
Intercentre reproducibility of cardiac apparent diffusion coefficient and fractional anisotropy in healthy volunteers
Authors
Elizabeth M Tunnicliffe
Andrew D Scott
Pedro Ferreira
Rina Ariga
Laura-Ann McGill
Sonia Nielles-Vallespin
Stefan Neubauer
Dudley J Pennell
Matthew D Robson
David N Firmin
Publication date
01-12-2014
Publisher
BioMed Central
Published in
Journal of Cardiovascular Magnetic Resonance / Issue 1/2014
Electronic ISSN: 1532-429X
DOI
https://doi.org/10.1186/1532-429X-16-31

Other articles of this Issue 1/2014

Journal of Cardiovascular Magnetic Resonance 1/2014 Go to the issue