Skip to main content
Top
Published in: Radiation Oncology 1/2014

Open Access 01-12-2014 | Research

Integrating respiratory-gated PET-based target volume delineation in liver SBRT planning, a pilot study

Authors: Olivier Riou, Benjamin Serrano, David Azria, Benoit Paulmier, Remy Villeneuve, Pascal Fenoglietto, Antonella Artenie, Cécile Ortholan, Marc Faraggi, Juliette Thariat

Published in: Radiation Oncology | Issue 1/2014

Login to get access

Abstract

Background

To assess the feasibility and benefit of integrating four-dimensional (4D) Positron Emission Tomography (PET) – computed tomography (CT) for liver stereotactic body radiation therapy (SBRT) planning.

Methods

8 patients with 14 metastases were accrued in the study. They all underwent a non-gated PET and a 4D PET centered on the liver. The same CT scan was used for attenuation correction, registration, and considered the planning CT for SBRT planning. Six PET phases were reconstructed for each 4D PET. By applying an individualized threshold to the 4D PET, a Biological Internal Target Volume (BITV) was generated for each lesion. A gated Planning Target Volume (PTVg) was created by adding 3 mm to account for set-up margins. This volume was compared to a manual Planning Target Volume (PTV) delineated with the help of a semi-automatic Biological Target Volume (BTV) obtained from the non-gated exam. A 5 mm radial and a 10 mm craniocaudal margins were applied to account for tumor motion and set-up margins to create the PTV.

Results

One undiagnosed liver metastasis was discovered thanks to the 4D PET. The semi-automatic BTV were significantly smaller than the BITV (p = 0.0031). However, after applying adapted margins, 4D PET allowed a statistically significant decrease in the PTVg as compared to the PTV (p = 0.0052).

Conclusions

In comparison to non-gated PET, 4D PET may better define the respiratory movements of liver targets and improve SBRT planning for liver metastases. Furthermore, non respiratory-gated PET exams can both misdiagnose liver metastases and underestimate the real internal target volumes.
Appendix
Available only for authorised users
Literature
1.
go back to reference Dawood O, Mahadevan A, Goodman KA: Stereotactic body radiation therapy for liver metastases. Eur J Cancer 2009,45(17):2947-2959. 10.1016/j.ejca.2009.08.011CrossRefPubMed Dawood O, Mahadevan A, Goodman KA: Stereotactic body radiation therapy for liver metastases. Eur J Cancer 2009,45(17):2947-2959. 10.1016/j.ejca.2009.08.011CrossRefPubMed
2.
go back to reference Lochan R, White SA, Manas DM: Liver resection for colorectal liver metastasis. Surg Oncol 2007,16(1):33-45. 10.1016/j.suronc.2007.04.010CrossRefPubMed Lochan R, White SA, Manas DM: Liver resection for colorectal liver metastasis. Surg Oncol 2007,16(1):33-45. 10.1016/j.suronc.2007.04.010CrossRefPubMed
3.
go back to reference Pawlik TM, Izzo F, Cohen DS, Morris JS, Curley SA: Combined resection and radiofrequency ablation for advanced hepatic malignancies: results in 172 patients. Ann Surg Oncol 2003,10(9):1059-1069. 10.1245/ASO.2003.03.026CrossRefPubMed Pawlik TM, Izzo F, Cohen DS, Morris JS, Curley SA: Combined resection and radiofrequency ablation for advanced hepatic malignancies: results in 172 patients. Ann Surg Oncol 2003,10(9):1059-1069. 10.1245/ASO.2003.03.026CrossRefPubMed
4.
go back to reference Boutros C, Espat NJ: What, how, and when to offer nonresectional therapy for colorectal cancer liver metastases. J Gastrointest Surg 2011,15(3):420-422. 10.1007/s11605-011-1428-7CrossRefPubMed Boutros C, Espat NJ: What, how, and when to offer nonresectional therapy for colorectal cancer liver metastases. J Gastrointest Surg 2011,15(3):420-422. 10.1007/s11605-011-1428-7CrossRefPubMed
5.
go back to reference Liang S-X, Zhu X-D, Xu Z-Y, Zhu J, Zhao J-D, Lu H-J, Yang Y-L, Chen L, Wang A-Y, Fu X-L, Jiang G-L: Radiation-induced liver disease in three-dimensional conformal radiation therapy for primary liver carcinoma: The risk factors and hepatic radiation tolerance. Int J Radiat Oncol Biol Phys 2006,65(2):426-434. 10.1016/j.ijrobp.2005.12.031CrossRefPubMed Liang S-X, Zhu X-D, Xu Z-Y, Zhu J, Zhao J-D, Lu H-J, Yang Y-L, Chen L, Wang A-Y, Fu X-L, Jiang G-L: Radiation-induced liver disease in three-dimensional conformal radiation therapy for primary liver carcinoma: The risk factors and hepatic radiation tolerance. Int J Radiat Oncol Biol Phys 2006,65(2):426-434. 10.1016/j.ijrobp.2005.12.031CrossRefPubMed
6.
go back to reference Lee MT, Kim JJ, Dinniwell R, Brierley J, Lockwood G, Wong R, Cummings B, Ringash J, Tse RV, Knox JJ, Dawson LA: Phase I study of individualized stereotactic body radiotherapy of liver metastases. J Clin Oncol 2009,27(10):1585-1591. 10.1200/JCO.2008.20.0600CrossRefPubMed Lee MT, Kim JJ, Dinniwell R, Brierley J, Lockwood G, Wong R, Cummings B, Ringash J, Tse RV, Knox JJ, Dawson LA: Phase I study of individualized stereotactic body radiotherapy of liver metastases. J Clin Oncol 2009,27(10):1585-1591. 10.1200/JCO.2008.20.0600CrossRefPubMed
7.
go back to reference Rusthoven KE, Kavanagh BD, Cardenes H, Stieber VW, Burri SH, Feigenberg SJ, Chidel MA, Pugh TJ, Franklin W, Kane M, Gaspar LE, Schefter TE: Multi-institutional phase I/II trial of stereotactic body radiation therapy for liver metastases. J Clin Oncol 2009,27(10):1572-1578. 10.1200/JCO.2008.19.6329CrossRefPubMed Rusthoven KE, Kavanagh BD, Cardenes H, Stieber VW, Burri SH, Feigenberg SJ, Chidel MA, Pugh TJ, Franklin W, Kane M, Gaspar LE, Schefter TE: Multi-institutional phase I/II trial of stereotactic body radiation therapy for liver metastases. J Clin Oncol 2009,27(10):1572-1578. 10.1200/JCO.2008.19.6329CrossRefPubMed
8.
go back to reference Høyer M, Swaminath A, Bydder S, Lock M, Méndez Romero A, Kavanagh B, Goodman KA, Okunieff P, Dawson LA: Radiotherapy for liver metastases: a review of evidence. Int J Radiat Oncol Biol Phys 2012,82(3):1047-1057. 10.1016/j.ijrobp.2011.07.020CrossRefPubMed Høyer M, Swaminath A, Bydder S, Lock M, Méndez Romero A, Kavanagh B, Goodman KA, Okunieff P, Dawson LA: Radiotherapy for liver metastases: a review of evidence. Int J Radiat Oncol Biol Phys 2012,82(3):1047-1057. 10.1016/j.ijrobp.2011.07.020CrossRefPubMed
9.
go back to reference Pech M, Mohnike K, Wieners G, Bialek E, Dudeck O, Seidensticker M, Peters N, Wust P, Gademann G, Ricke J: Radiotherapy of liver metastases. Comparison of target volumes and dose-volume histograms employing CT- or MRI-based treatment planning. Strahlenther Onkol 2008,184(5):256-261. 10.1007/s00066-008-1849-8CrossRefPubMed Pech M, Mohnike K, Wieners G, Bialek E, Dudeck O, Seidensticker M, Peters N, Wust P, Gademann G, Ricke J: Radiotherapy of liver metastases. Comparison of target volumes and dose-volume histograms employing CT- or MRI-based treatment planning. Strahlenther Onkol 2008,184(5):256-261. 10.1007/s00066-008-1849-8CrossRefPubMed
10.
go back to reference Bundschuh RA, Andratschke N, Dinges J, Duma MN, Astner ST, Brügel M, Ziegler SI, Molls M, Schwaiger M, Essler M: Respiratory gated [(18)F]FDG PET/CT for target volume delineation in stereotactic radiation treatment of liver metastases. Strahlenther Onkol 2012,188(7):592-598. 10.1007/s00066-012-0094-3CrossRefPubMed Bundschuh RA, Andratschke N, Dinges J, Duma MN, Astner ST, Brügel M, Ziegler SI, Molls M, Schwaiger M, Essler M: Respiratory gated [(18)F]FDG PET/CT for target volume delineation in stereotactic radiation treatment of liver metastases. Strahlenther Onkol 2012,188(7):592-598. 10.1007/s00066-012-0094-3CrossRefPubMed
11.
go back to reference Teefey SA, Hildeboldt CC, Dehdashti F, Siegel BA, Peters MG, Heiken JP, Brown JF, McFarland EG, Middleton WD, Balfe DM, Ritter JH: Detection of primary hepatic malignancy in liver transplant candidates: prospective comparison of CT, MR imaging, US, and PET. Radiology 2003,226(2):533-542. 10.1148/radiol.2262011980CrossRefPubMed Teefey SA, Hildeboldt CC, Dehdashti F, Siegel BA, Peters MG, Heiken JP, Brown JF, McFarland EG, Middleton WD, Balfe DM, Ritter JH: Detection of primary hepatic malignancy in liver transplant candidates: prospective comparison of CT, MR imaging, US, and PET. Radiology 2003,226(2):533-542. 10.1148/radiol.2262011980CrossRefPubMed
12.
go back to reference Topal B, Flamen P, Aerts R, D’Hoore A, Filez L, Van Cutsem E, Mortelmans L, Penninckx F: Clinical value of whole-body emission tomography in potentially curable colorectal liver metastases. Eur J Surg Oncol 2001,27(2):175-179. 10.1053/ejso.2000.1075CrossRefPubMed Topal B, Flamen P, Aerts R, D’Hoore A, Filez L, Van Cutsem E, Mortelmans L, Penninckx F: Clinical value of whole-body emission tomography in potentially curable colorectal liver metastases. Eur J Surg Oncol 2001,27(2):175-179. 10.1053/ejso.2000.1075CrossRefPubMed
13.
go back to reference Steffen IG, Wust P, Rühl R, Grieser C, Schnapauff D, Lüdemann L, Grabik W, Ricke J, Amthauer H, Hamm B, Lopez Hänninen E, Denecke T: Value of combined PET/CT for radiation planning in CT-guided percutaneous interstitial high-dose-rate single-fraction brachytherapy for colorectal liver metastases. Int J Radiat Oncol Biol Phys 2010,77(4):1178-1185. 10.1016/j.ijrobp.2009.06.047CrossRefPubMed Steffen IG, Wust P, Rühl R, Grieser C, Schnapauff D, Lüdemann L, Grabik W, Ricke J, Amthauer H, Hamm B, Lopez Hänninen E, Denecke T: Value of combined PET/CT for radiation planning in CT-guided percutaneous interstitial high-dose-rate single-fraction brachytherapy for colorectal liver metastases. Int J Radiat Oncol Biol Phys 2010,77(4):1178-1185. 10.1016/j.ijrobp.2009.06.047CrossRefPubMed
14.
go back to reference Nehmeh SA, Erdi YE, Ling CC, Rosenzweig KE, Schoder H, Larson SM, Macapinlac HA, Squire OD, Humm JL: Effect of respiratory gating on quantifying PET images of lung cancer. J Nucl Med 2002,43(7):876-881.PubMed Nehmeh SA, Erdi YE, Ling CC, Rosenzweig KE, Schoder H, Larson SM, Macapinlac HA, Squire OD, Humm JL: Effect of respiratory gating on quantifying PET images of lung cancer. J Nucl Med 2002,43(7):876-881.PubMed
15.
go back to reference Aristophanous M, Berbeco RI, Killoran JH, Yap JT, Sher DJ, Allen AM, Larson E, Chen AB: Clinical utility of 4D FDG-PET/CT scans in radiation treatment planning. Int J Radiat Oncol Biol Phys 2012,82(1):e99-e105. 10.1016/j.ijrobp.2010.12.060CrossRefPubMed Aristophanous M, Berbeco RI, Killoran JH, Yap JT, Sher DJ, Allen AM, Larson E, Chen AB: Clinical utility of 4D FDG-PET/CT scans in radiation treatment planning. Int J Radiat Oncol Biol Phys 2012,82(1):e99-e105. 10.1016/j.ijrobp.2010.12.060CrossRefPubMed
16.
go back to reference Guerra L, Meregalli S, Zorz A, Niespolo R, De Ponti E, Elisei F, Morzenti S, Brenna S, Crespi A, Gardani G, Messa C: Comparative evaluation of CT-based and respiratory-gated PET/CT-based planning target volume (PTV) in the definition of radiation treatment planning in lung cancer: preliminary results. Eur J Nucl Med Mol Imaging 2013. Nov [Epub ahead of print] Guerra L, Meregalli S, Zorz A, Niespolo R, De Ponti E, Elisei F, Morzenti S, Brenna S, Crespi A, Gardani G, Messa C: Comparative evaluation of CT-based and respiratory-gated PET/CT-based planning target volume (PTV) in the definition of radiation treatment planning in lung cancer: preliminary results. Eur J Nucl Med Mol Imaging 2013. Nov [Epub ahead of print]
17.
go back to reference Hawkins MA, Brock KK, Eccles C, Moseley D, Jaffray D, Dawson LA: Assessment of residual error in liver position using kV cone-beam computed tomography for liver cancer high-precision radiation therapy. Int J Radiat Oncol Biol Phys 2006,66(2):610-619. 10.1016/j.ijrobp.2006.03.026CrossRefPubMed Hawkins MA, Brock KK, Eccles C, Moseley D, Jaffray D, Dawson LA: Assessment of residual error in liver position using kV cone-beam computed tomography for liver cancer high-precision radiation therapy. Int J Radiat Oncol Biol Phys 2006,66(2):610-619. 10.1016/j.ijrobp.2006.03.026CrossRefPubMed
18.
go back to reference Dawson LA, Eccles C, Bissonnette J-P, Brock KK: Accuracy of daily image guidance for hypofractionated liver radiotherapy with active breathing control. Int J Radiat Oncol Biol Phys 2005,62(4):1247-1252. 10.1016/j.ijrobp.2005.03.072CrossRefPubMed Dawson LA, Eccles C, Bissonnette J-P, Brock KK: Accuracy of daily image guidance for hypofractionated liver radiotherapy with active breathing control. Int J Radiat Oncol Biol Phys 2005,62(4):1247-1252. 10.1016/j.ijrobp.2005.03.072CrossRefPubMed
19.
go back to reference Hansen AT, Petersen JB, Høyer M: Internal movement, set-up accuracy and margins for stereotactic body radiotherapy using a stereotactic body frame. Acta Oncol 2006,45(7):948-952. 10.1080/02841860600911172CrossRefPubMed Hansen AT, Petersen JB, Høyer M: Internal movement, set-up accuracy and margins for stereotactic body radiotherapy using a stereotactic body frame. Acta Oncol 2006,45(7):948-952. 10.1080/02841860600911172CrossRefPubMed
20.
go back to reference Stinauer MA, Diot Q, Westerly DC, Schefter TE, Kavanagh BD: Fluorodeoxyglucose positron emission tomography response and normal tissue regeneration after stereotactic body radiotherapy to liver metastases. Int J Radiat Oncol Biol Phys 2012,83(5):e613-e618. 10.1016/j.ijrobp.2012.02.008CrossRefPubMed Stinauer MA, Diot Q, Westerly DC, Schefter TE, Kavanagh BD: Fluorodeoxyglucose positron emission tomography response and normal tissue regeneration after stereotactic body radiotherapy to liver metastases. Int J Radiat Oncol Biol Phys 2012,83(5):e613-e618. 10.1016/j.ijrobp.2012.02.008CrossRefPubMed
21.
go back to reference Keall PJ, Mageras GS, Balter JM, Emery RS, Forster KM, Jiang SB, Kapatoes JM, Low DA, Murphy MJ, Murray BR: The management of respiratory motion in radiation oncology report of AAPM task group 76. Med Phys 2006,33(10):3874-3900. 10.1118/1.2349696CrossRefPubMed Keall PJ, Mageras GS, Balter JM, Emery RS, Forster KM, Jiang SB, Kapatoes JM, Low DA, Murphy MJ, Murray BR: The management of respiratory motion in radiation oncology report of AAPM task group 76. Med Phys 2006,33(10):3874-3900. 10.1118/1.2349696CrossRefPubMed
22.
go back to reference Brandner ED, Wu A, Chen H, Heron D, Kalnicki S, Komanduri K, Gerszten K, Burton S, Ahmed I, Shou Z: Abdominal organ motion measured using 4D CT. Int J Radiat Oncol Biol Phys 2006, 65: 554-560. 10.1016/j.ijrobp.2005.12.042CrossRefPubMed Brandner ED, Wu A, Chen H, Heron D, Kalnicki S, Komanduri K, Gerszten K, Burton S, Ahmed I, Shou Z: Abdominal organ motion measured using 4D CT. Int J Radiat Oncol Biol Phys 2006, 65: 554-560. 10.1016/j.ijrobp.2005.12.042CrossRefPubMed
23.
go back to reference Nehmeh SA, El-Zeftawy H, Greco C, Schwartz J, Erdi YE, Kirov A, Schmidtlein CR, Gyau AB, Larson SM, Humm JL: An iterative technique to segment PET lesions using a Monte Carlo based mathematical model. Med Phys 2009, 36: 4803-4809. 10.1118/1.3222732CrossRefPubMed Nehmeh SA, El-Zeftawy H, Greco C, Schwartz J, Erdi YE, Kirov A, Schmidtlein CR, Gyau AB, Larson SM, Humm JL: An iterative technique to segment PET lesions using a Monte Carlo based mathematical model. Med Phys 2009, 36: 4803-4809. 10.1118/1.3222732CrossRefPubMed
24.
go back to reference Lamb JM, Robinson C, Bradley J, Laforest R, Dehdashti F, White BM, Wuenschel S, Low DA: Generating lung tumor internal target volumes from 4D-PET maximum intensity projections. Med Phys 2011,38(10):5732-5737. 10.1118/1.3633896PubMedCentralCrossRefPubMed Lamb JM, Robinson C, Bradley J, Laforest R, Dehdashti F, White BM, Wuenschel S, Low DA: Generating lung tumor internal target volumes from 4D-PET maximum intensity projections. Med Phys 2011,38(10):5732-5737. 10.1118/1.3633896PubMedCentralCrossRefPubMed
25.
go back to reference Guerra L, De Ponti E, Elisei F, Bettinardi V, Landoni C, Picchio M, Gilardi MC, Versari A, Fioroni F, Dziuk M, Koza M, Ahond-Vionnet R, Collin B, Messa C: Respiratory gated PET/CT in a European multicentre retrospective study: added diagnostic value in detection and characterization of lung lesions. Eur J Nucl Med Mol Imaging 2012,39(9):1381-1390. 10.1007/s00259-012-2148-2CrossRefPubMed Guerra L, De Ponti E, Elisei F, Bettinardi V, Landoni C, Picchio M, Gilardi MC, Versari A, Fioroni F, Dziuk M, Koza M, Ahond-Vionnet R, Collin B, Messa C: Respiratory gated PET/CT in a European multicentre retrospective study: added diagnostic value in detection and characterization of lung lesions. Eur J Nucl Med Mol Imaging 2012,39(9):1381-1390. 10.1007/s00259-012-2148-2CrossRefPubMed
26.
go back to reference Biehl KJ, Kong FM, Dehdashti F, Jin JY, Mutic S, El Naqa I, Siegel BA, Bradley JD: 18 F-FDG PET definition of gross tumor volume for radiotherapy of non–small cell lung cancer: is a single standardized uptake value threshold approach appropriate? J Nucl Med 2006,47(11):1808-1812.PubMed Biehl KJ, Kong FM, Dehdashti F, Jin JY, Mutic S, El Naqa I, Siegel BA, Bradley JD: 18 F-FDG PET definition of gross tumor volume for radiotherapy of non–small cell lung cancer: is a single standardized uptake value threshold approach appropriate? J Nucl Med 2006,47(11):1808-1812.PubMed
27.
go back to reference Black QC, Grills IS, Kestin LL, Wong C-YO, Wong JW, Martinez AA, Yan D: Defining a radiotherapy target with positron emission tomography. Int J Radiat Oncol Biol Phys 2004,60(4):1272-1282. 10.1016/j.ijrobp.2004.06.254CrossRefPubMed Black QC, Grills IS, Kestin LL, Wong C-YO, Wong JW, Martinez AA, Yan D: Defining a radiotherapy target with positron emission tomography. Int J Radiat Oncol Biol Phys 2004,60(4):1272-1282. 10.1016/j.ijrobp.2004.06.254CrossRefPubMed
28.
go back to reference Yu J, Li X, Xing L, Mu D, Fu Z, Sun X, Sun X, Yang G, Zhang B, Sun X, Ling CC: Comparison of tumor volumes as determined by pathologic examination and FDG-PET/CT images of non-small-cell lung cancer: a pilot study. Int J Radiat Oncol Biol Phys 2009,75(5):1468-1474. 10.1016/j.ijrobp.2009.01.019CrossRefPubMed Yu J, Li X, Xing L, Mu D, Fu Z, Sun X, Sun X, Yang G, Zhang B, Sun X, Ling CC: Comparison of tumor volumes as determined by pathologic examination and FDG-PET/CT images of non-small-cell lung cancer: a pilot study. Int J Radiat Oncol Biol Phys 2009,75(5):1468-1474. 10.1016/j.ijrobp.2009.01.019CrossRefPubMed
29.
go back to reference Zaidi H, El Naqa I: PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques. Eur J Nucl Med Mol Imaging 2010,37(11):2165-2187. 10.1007/s00259-010-1423-3CrossRefPubMed Zaidi H, El Naqa I: PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques. Eur J Nucl Med Mol Imaging 2010,37(11):2165-2187. 10.1007/s00259-010-1423-3CrossRefPubMed
30.
go back to reference Schinagl DAX, Vogel WV, Hoffmann AL, Van Dalen JA, Oyen WJ, Kaanders JHAM: Comparison of five segmentation tools for [(18)F]fluoro-deoxy-glucose-positron emission tomography-based target volume definition in head and neck cancer. Int J Radiat Oncol Biol Phys 2007,69(4):1282-1289. 10.1016/j.ijrobp.2007.07.2333CrossRefPubMed Schinagl DAX, Vogel WV, Hoffmann AL, Van Dalen JA, Oyen WJ, Kaanders JHAM: Comparison of five segmentation tools for [(18)F]fluoro-deoxy-glucose-positron emission tomography-based target volume definition in head and neck cancer. Int J Radiat Oncol Biol Phys 2007,69(4):1282-1289. 10.1016/j.ijrobp.2007.07.2333CrossRefPubMed
31.
go back to reference Daisnes JF, Duprez T, Weynand B, Lonneux M, Hamoir M, Reychler H, Grégoire V: Tumor volume in pharyngolaryngeal squamous cell carcinoma: Comparison at CT, MR Imaging and FDG PET and validation with surgical specimen. Radiology 2004, 233: 93-100. 10.1148/radiol.2331030660CrossRef Daisnes JF, Duprez T, Weynand B, Lonneux M, Hamoir M, Reychler H, Grégoire V: Tumor volume in pharyngolaryngeal squamous cell carcinoma: Comparison at CT, MR Imaging and FDG PET and validation with surgical specimen. Radiology 2004, 233: 93-100. 10.1148/radiol.2331030660CrossRef
32.
go back to reference Scripes PG, Yaparpalvi R: Technical aspects of positron emission tomography/computed tomography in radiotherapy treatment planning. Semin Nucl Med 2012, 42: 283-288. 10.1053/j.semnuclmed.2012.04.006CrossRefPubMed Scripes PG, Yaparpalvi R: Technical aspects of positron emission tomography/computed tomography in radiotherapy treatment planning. Semin Nucl Med 2012, 42: 283-288. 10.1053/j.semnuclmed.2012.04.006CrossRefPubMed
33.
go back to reference Daisne J-F, Sibomana M, Bol A, Cosnard G, Lonneux M, Grégoire V: Evaluation of a multimodality image (CT, MRI and PET) coregistration procedure on phantom and head and neck cancer patients: accuracy, reproducibility and consistency. Radiother Oncol 2003, 69: 237-245. 10.1016/j.radonc.2003.10.009CrossRefPubMed Daisne J-F, Sibomana M, Bol A, Cosnard G, Lonneux M, Grégoire V: Evaluation of a multimodality image (CT, MRI and PET) coregistration procedure on phantom and head and neck cancer patients: accuracy, reproducibility and consistency. Radiother Oncol 2003, 69: 237-245. 10.1016/j.radonc.2003.10.009CrossRefPubMed
34.
go back to reference Goerres GW, Kamel E, Seifert B, Burger C, Buck A, Hany TF, Von Schulthess GK: Accuracy of image coregistration of pulmonary lesions in patients with non-small cell lung cancer using an integrated PET/CT system. J Nucl Med 2002, 43: 1469-1475.PubMed Goerres GW, Kamel E, Seifert B, Burger C, Buck A, Hany TF, Von Schulthess GK: Accuracy of image coregistration of pulmonary lesions in patients with non-small cell lung cancer using an integrated PET/CT system. J Nucl Med 2002, 43: 1469-1475.PubMed
Metadata
Title
Integrating respiratory-gated PET-based target volume delineation in liver SBRT planning, a pilot study
Authors
Olivier Riou
Benjamin Serrano
David Azria
Benoit Paulmier
Remy Villeneuve
Pascal Fenoglietto
Antonella Artenie
Cécile Ortholan
Marc Faraggi
Juliette Thariat
Publication date
01-12-2014
Publisher
BioMed Central
Published in
Radiation Oncology / Issue 1/2014
Electronic ISSN: 1748-717X
DOI
https://doi.org/10.1186/1748-717X-9-127

Other articles of this Issue 1/2014

Radiation Oncology 1/2014 Go to the issue