Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 2/2012

01-02-2012 | Trauma Surgery

Inside out rafting K-wire technique for tibial plateau fractures

Authors: Yong-Cheol Yoon, Jong-Keon Oh, Chang-Wug Oh, Dipit Sahu, Jin-Ho Hwang, Jae-Woo Cho

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 2/2012

Login to get access

Abstract

With the introduction of 3.5 anatomically pre-shaped plates, the rafting screw technique is gaining popularity in recent years for the management of lateral tibial plateau fractures with articular depression. To gain access to the depressed articular fragments, the split fragment is hinged open laterally. We elevate the depressed articular fragments to the normal level. The defect below is filled with bone graft or its substitutes. We then close the split fragment and apply rafting screws either through the screw holes of the plate or separately above the plate rather in a blind fashion. We therefore cannot be sure that the rafting screws are supporting the specific elevated fragments. For this reason some surgeons place the rafting screws from within and then close the lateral fragment over the screws. This so-called embedded rafting screw technique carries the risk of difficulty in removal, especially in case of an infection. Here we describe the inside out rafting technique to tackle this problem.
Literature
1.
go back to reference Karunakar MA, Egol KA, Peindl R, Harrow ME, Bosse MJ, Kellam JF (2002) Split depression tibial plateau fractures: a biomechanical study. J Orthop Trauma 16:172–177PubMedCrossRef Karunakar MA, Egol KA, Peindl R, Harrow ME, Bosse MJ, Kellam JF (2002) Split depression tibial plateau fractures: a biomechanical study. J Orthop Trauma 16:172–177PubMedCrossRef
2.
go back to reference Patil S, Mahon A, Green S, McMurtry I, Port A (2006) A biomechanical study comparing a raft of 3.5 mm cortical screws with 6.5 mm cancellous screws in depressed tibial plateau fractures. Knee 13:231–235PubMedCrossRef Patil S, Mahon A, Green S, McMurtry I, Port A (2006) A biomechanical study comparing a raft of 3.5 mm cortical screws with 6.5 mm cancellous screws in depressed tibial plateau fractures. Knee 13:231–235PubMedCrossRef
3.
go back to reference Beris AE, Soucacos PN, Glisson RR, Seaber AV, Urbaniak JR (1996) Load tolerance of tibial plateau depressions reinforced with a cluster of K-wires. Bull Hosp Jt Dis 55:12–15PubMed Beris AE, Soucacos PN, Glisson RR, Seaber AV, Urbaniak JR (1996) Load tolerance of tibial plateau depressions reinforced with a cluster of K-wires. Bull Hosp Jt Dis 55:12–15PubMed
4.
go back to reference Mills WJ, Nork SE (2002) Open reduction and internal fixation of high-energy tibial plateau fractures. Orthop Clin N Am 33:177–198 ixCrossRef Mills WJ, Nork SE (2002) Open reduction and internal fixation of high-energy tibial plateau fractures. Orthop Clin N Am 33:177–198 ixCrossRef
5.
go back to reference Ballmer FT, Hertel R, Notzli HP (2000) Treatment of tibial plateau fractures with small fragment internal fixation: a preliminary report. J Orthop Trauma 14:467–474PubMedCrossRef Ballmer FT, Hertel R, Notzli HP (2000) Treatment of tibial plateau fractures with small fragment internal fixation: a preliminary report. J Orthop Trauma 14:467–474PubMedCrossRef
Metadata
Title
Inside out rafting K-wire technique for tibial plateau fractures
Authors
Yong-Cheol Yoon
Jong-Keon Oh
Chang-Wug Oh
Dipit Sahu
Jin-Ho Hwang
Jae-Woo Cho
Publication date
01-02-2012
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 2/2012
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-011-1409-z

Other articles of this Issue 2/2012

Archives of Orthopaedic and Trauma Surgery 2/2012 Go to the issue