Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 12/2010

01-12-2010 | Orthopaedic Surgery

Initial increased wear debris of XLPE-Al2O3 bearing in total hip arthroplasties

Authors: Marcus Jäger, Michael Behringer, Christoph Zilkens, Travis Matheney, Rüdiger Krauspe

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 12/2010

Login to get access

Abstract

Introduction

Aseptic implant loosening caused by wear debris is a common reason for early implant failure after total hip replacement (THR).

Materials and methods

We prospectively studied 96 patients (110 hips), 48 men and 48 women (mean age 46.8 years, mean body mass index 26.1) who had undergone cementless THR (titanium stem, press-fit cup, Al2O3 ball, XLPE liner) at a mean of 17.4 months (SD 13.4).

Results

The semi-computerized evaluation of wear rate showed wear of 0.25 mm (SD 0.3) corresponding to a volume of 97.6 mm3 (SD 121.1) during the first year. It was remarkable that the annual rate of wear was significantly lower in the second year: 0.14 mm (SD 0.1), 60.0 mm3 (SD 78.7). The implant survival rate was 100%. However, two patients underwent revision surgery.

Interpretation

Good, early functionality can be achieved by a cementless THR including a modular stem and a XLPE-Al2O3 bearing system. The rate of wear debris for XLPE-Al3O2 was much higher than expected within the first year after THR. However, after the initial running-in period a significant decrease of wear was documented, suggesting a biphasic abrasion [0.38 mm (SD 0.2) within the first year vs. 0.14 mm (SD 0.1)] after the running-in-period 1 year following surgery.
Literature
1.
go back to reference Kim WY, Greidanus NV, Duncan CP, Masri BA, Garbuz DS (2008) Porous tantalum uncemented acetabular shells in revision total hip replacement: two to four year clinical and radiographic results. Hip Int 18:17–22PubMed Kim WY, Greidanus NV, Duncan CP, Masri BA, Garbuz DS (2008) Porous tantalum uncemented acetabular shells in revision total hip replacement: two to four year clinical and radiographic results. Hip Int 18:17–22PubMed
2.
go back to reference McLaughlin JR, Lee KR (1997) Total hip arthroplasty with an uncemented femoral component. Excellent results at ten-year follow-up. J Bone Joint Surg Br 79:900–907CrossRefPubMed McLaughlin JR, Lee KR (1997) Total hip arthroplasty with an uncemented femoral component. Excellent results at ten-year follow-up. J Bone Joint Surg Br 79:900–907CrossRefPubMed
3.
go back to reference Reigstad O, Siewers P, Rokkum M, Espehaug B (2008) Excellent long-term survival of an uncemented press-fit stem and screw cup in young patients: follow-up of 75 hips for 15–18 years. Acta Orthop 79:194–202CrossRefPubMed Reigstad O, Siewers P, Rokkum M, Espehaug B (2008) Excellent long-term survival of an uncemented press-fit stem and screw cup in young patients: follow-up of 75 hips for 15–18 years. Acta Orthop 79:194–202CrossRefPubMed
4.
go back to reference Siegmeth A, Duncan CP, Masri BA, Kim WY, Garbuz DS (2009) Modular tantalum augments for acetabular defects in revision hip arthroplasty. Clin Orthop Relat Res 467:199–205CrossRefPubMed Siegmeth A, Duncan CP, Masri BA, Kim WY, Garbuz DS (2009) Modular tantalum augments for acetabular defects in revision hip arthroplasty. Clin Orthop Relat Res 467:199–205CrossRefPubMed
5.
go back to reference Holt G, Murnaghan C, Reilly J, Meek RM (2007) The biology of aseptic osteolysis. Clin Orthop Relat Res 460:240–252PubMed Holt G, Murnaghan C, Reilly J, Meek RM (2007) The biology of aseptic osteolysis. Clin Orthop Relat Res 460:240–252PubMed
6.
go back to reference Landgraeber S, von Knoch M, Loer F, Wegner A, Tsokos M, Hussmann B, Totsch M (2008) Extrinsic and intrinsic pathways of apoptosis in aseptic loosening after total hip replacement. Biomaterials 29:3444–3450CrossRefPubMed Landgraeber S, von Knoch M, Loer F, Wegner A, Tsokos M, Hussmann B, Totsch M (2008) Extrinsic and intrinsic pathways of apoptosis in aseptic loosening after total hip replacement. Biomaterials 29:3444–3450CrossRefPubMed
7.
go back to reference Lenz R, Mittelmeier W, Hansmann D, Brem R, Diehl P, Fritsche A, Bader R (2009) Response of human osteoblasts exposed to wear particles generated at the interface of total hip stems and bone cement. J Biomed Mater Res A 89:370–378PubMed Lenz R, Mittelmeier W, Hansmann D, Brem R, Diehl P, Fritsche A, Bader R (2009) Response of human osteoblasts exposed to wear particles generated at the interface of total hip stems and bone cement. J Biomed Mater Res A 89:370–378PubMed
8.
go back to reference Germain MA, Hatton A, Williams S, Matthews JB, Stone MH, Fisher J, Ingham E (2003) Comparison of the cytotoxicity of clinically relevant cobalt–chromium and alumina ceramic wear particles in vitro. Biomaterials 24:469–479CrossRefPubMed Germain MA, Hatton A, Williams S, Matthews JB, Stone MH, Fisher J, Ingham E (2003) Comparison of the cytotoxicity of clinically relevant cobalt–chromium and alumina ceramic wear particles in vitro. Biomaterials 24:469–479CrossRefPubMed
9.
go back to reference Green TR, Fisher J, Matthews JB, Stone MH, Ingham E (2000) Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles. J Biomed Mater Res 53:490–497CrossRefPubMed Green TR, Fisher J, Matthews JB, Stone MH, Ingham E (2000) Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles. J Biomed Mater Res 53:490–497CrossRefPubMed
10.
go back to reference Ingham E, Fisher J (2000) Biological reactions to wear debris in total joint replacement. Proc Inst Mech Eng [H] 214:21–37 Ingham E, Fisher J (2000) Biological reactions to wear debris in total joint replacement. Proc Inst Mech Eng [H] 214:21–37
11.
go back to reference Kobayashi A, Bonfield W, Kadoya Y, Yamac T, Freeman MA, Scott G, Revell PA (1997) The size and shape of particulate polyethylene wear debris in total joint replacements. Proc Inst Mech Eng [H] 211:11–15 Kobayashi A, Bonfield W, Kadoya Y, Yamac T, Freeman MA, Scott G, Revell PA (1997) The size and shape of particulate polyethylene wear debris in total joint replacements. Proc Inst Mech Eng [H] 211:11–15
12.
go back to reference Purdue PE, Koulouvaris P, Nestor BJ, Sculco TP (2006) The central role of wear debris in periprosthetic osteolysis. Hss J 2:102–113CrossRefPubMed Purdue PE, Koulouvaris P, Nestor BJ, Sculco TP (2006) The central role of wear debris in periprosthetic osteolysis. Hss J 2:102–113CrossRefPubMed
13.
go back to reference Affatato S, Bersaglia G, Rocchi M, Taddei P, Fagnano C, Toni A (2005) Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions. Biomaterials 26:3259–3267CrossRefPubMed Affatato S, Bersaglia G, Rocchi M, Taddei P, Fagnano C, Toni A (2005) Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions. Biomaterials 26:3259–3267CrossRefPubMed
14.
go back to reference Tsukamoto R, Williams PA, Shoji H, Hirakawa K, Yamamoto K, Tsukamoto M, Clarke IC (2008) Wear of sequentially enhanced 9-Mrad polyethylene in 10 million cycle knee simulation study. J Biomed Mater Res B Appl Biomater 86:119–124PubMed Tsukamoto R, Williams PA, Shoji H, Hirakawa K, Yamamoto K, Tsukamoto M, Clarke IC (2008) Wear of sequentially enhanced 9-Mrad polyethylene in 10 million cycle knee simulation study. J Biomed Mater Res B Appl Biomater 86:119–124PubMed
15.
go back to reference Semlitsch M, Willert HG (1997) Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements. Proc Inst Mech Eng [H] 211:73–88 Semlitsch M, Willert HG (1997) Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements. Proc Inst Mech Eng [H] 211:73–88
16.
go back to reference Tateiwa T, Clarke IC, Williams PA, Garino J, Manaka M, Shishido T, Yamamoto K, Imakiire A (2008) Ceramic total hip arthroplasty in the United States: safety and risk issues revisited. Am J Orthop 37:E26–E31PubMed Tateiwa T, Clarke IC, Williams PA, Garino J, Manaka M, Shishido T, Yamamoto K, Imakiire A (2008) Ceramic total hip arthroplasty in the United States: safety and risk issues revisited. Am J Orthop 37:E26–E31PubMed
17.
go back to reference Fisher J, Jin Z, Tipper J, Stone M, Ingham E (2006) Tribology of alternative bearings. Clin Orthop Relat Res 453:25–34CrossRefPubMed Fisher J, Jin Z, Tipper J, Stone M, Ingham E (2006) Tribology of alternative bearings. Clin Orthop Relat Res 453:25–34CrossRefPubMed
18.
go back to reference Olyslaegers C, Defoort K, Simon JP, Vandenberghe L (2008) Wear in conventional and highly cross-linked polyethylene cups: a 5-year follow-up study. J Arthroplasty 23:489–494CrossRefPubMed Olyslaegers C, Defoort K, Simon JP, Vandenberghe L (2008) Wear in conventional and highly cross-linked polyethylene cups: a 5-year follow-up study. J Arthroplasty 23:489–494CrossRefPubMed
19.
go back to reference Hui AJ, McCalden RW, Martell JM, MacDonald SJ, Bourne RB, Rorabeck CH (2003) Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am 85-A:505–511PubMed Hui AJ, McCalden RW, Martell JM, MacDonald SJ, Bourne RB, Rorabeck CH (2003) Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am 85-A:505–511PubMed
20.
go back to reference Looney RJ, Boyd A, Totterman S, Seo GS, Tamez-Pena J, Campbell D, Novotny L, Olcott C, Martell J, Hayes FA, O’Keefe RJ, Schwarz EM (2002) Volumetric computerized tomography as a measurement of periprosthetic acetabular osteolysis and its correlation with wear. Arthritis Res 4:59–63CrossRefPubMed Looney RJ, Boyd A, Totterman S, Seo GS, Tamez-Pena J, Campbell D, Novotny L, Olcott C, Martell J, Hayes FA, O’Keefe RJ, Schwarz EM (2002) Volumetric computerized tomography as a measurement of periprosthetic acetabular osteolysis and its correlation with wear. Arthritis Res 4:59–63CrossRefPubMed
21.
go back to reference Martell JM, Berdia S (1997) Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am 79:1635–1641PubMed Martell JM, Berdia S (1997) Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am 79:1635–1641PubMed
22.
go back to reference Martell JM, Leopold SS, Liu X (2000) The effect of joint loading on acetabular wear measurement in total hip arthroplasty. J Arthroplasty 15:512–518CrossRefPubMed Martell JM, Leopold SS, Liu X (2000) The effect of joint loading on acetabular wear measurement in total hip arthroplasty. J Arthroplasty 15:512–518CrossRefPubMed
23.
go back to reference Gruen TA, McNeice GM, Amstutz HC (1979) E. Clin Orthop Relat Res 141:17–27 Gruen TA, McNeice GM, Amstutz HC (1979) E. Clin Orthop Relat Res 141:17–27
24.
go back to reference DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res:20–32 DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res:20–32
25.
go back to reference Maxian TA, Brown TD, Pedersen DR, Callaghan JJ (1996) A sliding-distance-coupled finite element formulation for polyethylene wear in total hip arthroplasty. J Biomech 29:687–692CrossRefPubMed Maxian TA, Brown TD, Pedersen DR, Callaghan JJ (1996) A sliding-distance-coupled finite element formulation for polyethylene wear in total hip arthroplasty. J Biomech 29:687–692CrossRefPubMed
26.
go back to reference Miyanishi K, Hara T, Kaminomachi S, Maekawa M, Iwamoto M, Torisu T (2008) Short-term wear of Japanese highly cross-linked polyethylene in cementless THA. Arch Orthop Trauma Surg 128:995–1000CrossRefPubMed Miyanishi K, Hara T, Kaminomachi S, Maekawa M, Iwamoto M, Torisu T (2008) Short-term wear of Japanese highly cross-linked polyethylene in cementless THA. Arch Orthop Trauma Surg 128:995–1000CrossRefPubMed
27.
go back to reference Glyn-Jones S, McLardy-Smith P, Gill HS, Murray DW (2008) The creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis. J Bone Joint Surg Br 90:556–561CrossRefPubMed Glyn-Jones S, McLardy-Smith P, Gill HS, Murray DW (2008) The creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis. J Bone Joint Surg Br 90:556–561CrossRefPubMed
28.
go back to reference Bitsch RG, Loidolt T, Heisel C, Ball S, Schmalzried TP (2008) Reduction of osteolysis with use of Marathon cross-linked polyethylene. A concise follow-up, at a minimum of five years, of a previous report. J Bone Joint Surg Am 90:1487–1491CrossRefPubMed Bitsch RG, Loidolt T, Heisel C, Ball S, Schmalzried TP (2008) Reduction of osteolysis with use of Marathon cross-linked polyethylene. A concise follow-up, at a minimum of five years, of a previous report. J Bone Joint Surg Am 90:1487–1491CrossRefPubMed
29.
go back to reference Jacobs CA, Christensen CP, Greenwald AS, McKellop H (2007) Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty. J Bone Joint Surg Am 89:2779–2786CrossRefPubMed Jacobs CA, Christensen CP, Greenwald AS, McKellop H (2007) Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty. J Bone Joint Surg Am 89:2779–2786CrossRefPubMed
30.
go back to reference Krushell RJ, Fingeroth RJ, Cushing MC (2005) Early femoral head penetration of a highly cross-linked polyethylene liner vs a conventional polyethylene liner: a case-controlled study. J Arthroplasty 20:73–76CrossRefPubMed Krushell RJ, Fingeroth RJ, Cushing MC (2005) Early femoral head penetration of a highly cross-linked polyethylene liner vs a conventional polyethylene liner: a case-controlled study. J Arthroplasty 20:73–76CrossRefPubMed
31.
go back to reference McCalden RW, Naudie DD, Yuan X, Bourne RB (2005) Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am 87:2323–2334CrossRefPubMed McCalden RW, Naudie DD, Yuan X, Bourne RB (2005) Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am 87:2323–2334CrossRefPubMed
32.
go back to reference Estok DM II, Bragdon CR, Plank GR, Huang A, Muratoglu OK, Harris WH (2005) The measurement of creep in ultrahigh molecular weight polyethylene: a comparison of conventional versus highly cross-linked polyethylene. J Arthroplasty 20:239–243CrossRefPubMed Estok DM II, Bragdon CR, Plank GR, Huang A, Muratoglu OK, Harris WH (2005) The measurement of creep in ultrahigh molecular weight polyethylene: a comparison of conventional versus highly cross-linked polyethylene. J Arthroplasty 20:239–243CrossRefPubMed
33.
go back to reference Goldsmith AA, Dowson D, Wroblewski BM, Siney PD, Fleming PA, Lane JM (2001) The effect of activity levels of total hip arthroplasty patients on socket penetration. J Arthroplasty 16:620–627CrossRefPubMed Goldsmith AA, Dowson D, Wroblewski BM, Siney PD, Fleming PA, Lane JM (2001) The effect of activity levels of total hip arthroplasty patients on socket penetration. J Arthroplasty 16:620–627CrossRefPubMed
34.
go back to reference Heisel C, Silva M, dela Rosa MA, Schmalzried TP (2004) Short-term in vivo wear of cross-linked polyethylene. J Bone Joint Surg Am 86-A:748–751PubMed Heisel C, Silva M, dela Rosa MA, Schmalzried TP (2004) Short-term in vivo wear of cross-linked polyethylene. J Bone Joint Surg Am 86-A:748–751PubMed
35.
go back to reference Manning DW, Chiang PP, Martell JM, Galante JO, Harris WH (2005) In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty. J Arthroplasty 20:880–886CrossRefPubMed Manning DW, Chiang PP, Martell JM, Galante JO, Harris WH (2005) In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty. J Arthroplasty 20:880–886CrossRefPubMed
36.
go back to reference Engh CA Jr, Stepniewski AS, Ginn SD, Beykirch SE, Sychterz-Terefenko CJ, Hopper RH Jr, Engh CA (2006) A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners. J Arthroplasty 21:17–25CrossRefPubMed Engh CA Jr, Stepniewski AS, Ginn SD, Beykirch SE, Sychterz-Terefenko CJ, Hopper RH Jr, Engh CA (2006) A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners. J Arthroplasty 21:17–25CrossRefPubMed
37.
go back to reference Hopper RH Jr, Young AM, Orishimo KF, McAuley JP (2003) Correlation between early and late wear rates in total hip arthroplasty with application to the performance of marathon cross-linked polyethylene liners. J Arthroplasty 18:60–67CrossRefPubMed Hopper RH Jr, Young AM, Orishimo KF, McAuley JP (2003) Correlation between early and late wear rates in total hip arthroplasty with application to the performance of marathon cross-linked polyethylene liners. J Arthroplasty 18:60–67CrossRefPubMed
38.
go back to reference Shorez JP, Harding TS, Atkinson PJ, Walter N (2008) Alteration of the amount and morphology of wear particles by the addition of loading profile transitions during artificial hip wear testing. Proc Inst Mech Eng [H] 222:865–875 Shorez JP, Harding TS, Atkinson PJ, Walter N (2008) Alteration of the amount and morphology of wear particles by the addition of loading profile transitions during artificial hip wear testing. Proc Inst Mech Eng [H] 222:865–875
Metadata
Title
Initial increased wear debris of XLPE-Al2O3 bearing in total hip arthroplasties
Authors
Marcus Jäger
Michael Behringer
Christoph Zilkens
Travis Matheney
Rüdiger Krauspe
Publication date
01-12-2010
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 12/2010
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-010-1061-z

Other articles of this Issue 12/2010

Archives of Orthopaedic and Trauma Surgery 12/2010 Go to the issue