Open Access 01-04-2005 | Research

Initial distribution volume of glucose can be approximated using a conventional glucose analyzer in the intensive care unit

Authors: Hironori Ishihara, Hitomi Nakamura, Hirobumi Okawa, Hajime Takase, Toshihito Tsubo, Kazuyoshi Hirota

Published in: Critical Care | Issue 2/2005

Login to get access

Abstract

Introduction

We previously reported that initial distribution volume of glucose (IDVG) reflects central extracellular fluid volume, and that IDVG may represent an indirect measure of cardiac preload that is independent of the plasma glucose values present before glucose injection or infusion of insulin and/or vasoactive drugs. The original IDVG measurement requires an accurate glucose analyzer and repeated arterial blood sampling over a period of 7 min after glucose injection. The purpose of the present study was to compare approximated IDVG, derived from just two blood samples, versus original IDVG, and to test whether approximated IDVG is an acceptable alternative measure of IDVG in the intensive care unit.

Methods

A total of 50 consecutive intensive care unit patients were included, and the first IDVG determination in each patient was analyzed. Glucose (5 g) was injected through the central venous line to calculate IDVG. Original IDVG was calculated using a one-compartment model from serial incremental arterial plasma glucose concentrations above preinjection using a reference glucose analyzer. Approximated IDVG was calculated from glucose concentrations in both plasma and whole blood, using a combined blood gas and glucose analyzer, drawn at two time points: immediately before glucose injection and 3 min after injection. Subsequently, each approximated IDVG was calculated using a formula we proposed previously.

Results

The difference (mean ± standard deviation) between approximated IDVG calculated from plasma samples and original IDVG was -0.05 ± 0.54 l, and the difference between approximated IDVG calculated from whole blood samples and original IDVG was -0.04 ± 0.61 l. There was a linear correlation between approximated and original IDVG (r2 = 0.92 for plasma samples, and r2 = 0.89 for whole blood samples).

Conclusion

Our findings demonstrate that there was good correlation between each approximated IDVG and original IDVG, although the two measures are not interchangeable. This suggests that approximated IDVG is clinically acceptable as an alternative calculation of IDVG, although approximated and original IDVGs are not equivalent; plasma rather than whole blood measurements are preferable.
Appendix
Available only for authorised users
Literature
1.
go back to reference Ishihara H, Suzuki A, Okawa H, Sakai I, Tsubo T, Matsuki A: The initial distribution volume of glucose rather than indocyanine green derived plasma volume is correlated with cardiac output following major surgery. Intensive Care Med 2000, 26: 1441-1448. 10.1007/s001340000653CrossRefPubMed Ishihara H, Suzuki A, Okawa H, Sakai I, Tsubo T, Matsuki A: The initial distribution volume of glucose rather than indocyanine green derived plasma volume is correlated with cardiac output following major surgery. Intensive Care Med 2000, 26: 1441-1448. 10.1007/s001340000653CrossRefPubMed
2.
go back to reference Ishihara H, Matsui A, Muraoka M, Tanabe T, Tsubo T, Matsuki A: Detection of capillary leakage by the indocyanine green and glucose dilutions in septic patients. Crit Care Med 2000, 28: 620-626. 10.1097/00003246-200003000-00003CrossRefPubMed Ishihara H, Matsui A, Muraoka M, Tanabe T, Tsubo T, Matsuki A: Detection of capillary leakage by the indocyanine green and glucose dilutions in septic patients. Crit Care Med 2000, 28: 620-626. 10.1097/00003246-200003000-00003CrossRefPubMed
3.
go back to reference Ishihara H, Suzuki A, Okawa H, Ebina T, Tsubo T, Matsuki A: Comparison of the initial distribution volume of glucose and plasma volume in thoracic fluid-accumulated patients. Crit Care Med 2001, 29: 1532-1538. 10.1097/00003246-200108000-00006CrossRefPubMed Ishihara H, Suzuki A, Okawa H, Ebina T, Tsubo T, Matsuki A: Comparison of the initial distribution volume of glucose and plasma volume in thoracic fluid-accumulated patients. Crit Care Med 2001, 29: 1532-1538. 10.1097/00003246-200108000-00006CrossRefPubMed
4.
go back to reference Ishihara H, Shimodate Y, Koh H, Isozaki K, Tsubo T, Matsuki A: The initial distribution of glucose and cardiac output in the critically ill. Can J Anaesth 1993, 40: 28-31.CrossRefPubMed Ishihara H, Shimodate Y, Koh H, Isozaki K, Tsubo T, Matsuki A: The initial distribution of glucose and cardiac output in the critically ill. Can J Anaesth 1993, 40: 28-31.CrossRefPubMed
5.
go back to reference Nakamura H, Ishihara H, Okawa H, Yatsu Y, Tsubo T, Matsuki A: Initial distribution volume of glucose is correlated with intrathoracic blood volume in hypovolemia and following volume loading in dogs. Eur J Anaesthesiol 2005, in press. Nakamura H, Ishihara H, Okawa H, Yatsu Y, Tsubo T, Matsuki A: Initial distribution volume of glucose is correlated with intrathoracic blood volume in hypovolemia and following volume loading in dogs. Eur J Anaesthesiol 2005, in press.
6.
go back to reference Gabbanelli V, Pantanetti S, Donati A, Montozzi A, Carbini C, Pelaia P: Initial distribution volume of glucose as noninvasive indicator of cardiac preload: comparison with intrathoracic blood volume. Intensive Care Med 2004, 30: 2067-2073. 10.1007/s00134-004-2421-3CrossRefPubMed Gabbanelli V, Pantanetti S, Donati A, Montozzi A, Carbini C, Pelaia P: Initial distribution volume of glucose as noninvasive indicator of cardiac preload: comparison with intrathoracic blood volume. Intensive Care Med 2004, 30: 2067-2073. 10.1007/s00134-004-2421-3CrossRefPubMed
7.
go back to reference Mi W, Ishihara H, Sakai T, Matsuki A: Possible overestimation of indocyanine green-derived plasma volume early after induction of anesthesia with propofol/fentanyl. Anesth Analg 2003, 97: 1421-1427. 10.1213/01.ANE.0000084361.12884.D1CrossRefPubMed Mi W, Ishihara H, Sakai T, Matsuki A: Possible overestimation of indocyanine green-derived plasma volume early after induction of anesthesia with propofol/fentanyl. Anesth Analg 2003, 97: 1421-1427. 10.1213/01.ANE.0000084361.12884.D1CrossRefPubMed
8.
go back to reference Rose BO, Ishihara H, Okawa H, Panning B, Piepenbrock S, Matsuki A: Repeatability of measurements of the initial distribution volume of glucose in haemodynamically stable patients. J Clin Pharm Ther 2004, 29: 317-323. 10.1111/j.1365-2710.2004.00565.xCrossRefPubMed Rose BO, Ishihara H, Okawa H, Panning B, Piepenbrock S, Matsuki A: Repeatability of measurements of the initial distribution volume of glucose in haemodynamically stable patients. J Clin Pharm Ther 2004, 29: 317-323. 10.1111/j.1365-2710.2004.00565.xCrossRefPubMed
9.
go back to reference Hirota K, Ishihara H, Tsubo T, Matsuki A: Estimation of the initial distribution volume of glucose by an incremental plasma glucose level at 3 min after i.v. glucose in humans. Br J Clin Pharmacol 1999, 47: 361-364. 10.1046/j.1365-2125.1999.00889.xPubMedCentralCrossRefPubMed Hirota K, Ishihara H, Tsubo T, Matsuki A: Estimation of the initial distribution volume of glucose by an incremental plasma glucose level at 3 min after i.v. glucose in humans. Br J Clin Pharmacol 1999, 47: 361-364. 10.1046/j.1365-2125.1999.00889.xPubMedCentralCrossRefPubMed
10.
go back to reference Akaike H: A new look at the statistical model identification. IEEE Trans Automat Control 1974, AC-19: 716-723. 10.1109/TAC.1974.1100705CrossRef Akaike H: A new look at the statistical model identification. IEEE Trans Automat Control 1974, AC-19: 716-723. 10.1109/TAC.1974.1100705CrossRef
11.
go back to reference Ray JG, Hamielec C, Mastracci T: Pilot study of the accuracy of bedside glucometry in the intensive care unit. Crit Care Med 2001, 29: 2205-2207. 10.1097/00003246-200111000-00025CrossRefPubMed Ray JG, Hamielec C, Mastracci T: Pilot study of the accuracy of bedside glucometry in the intensive care unit. Crit Care Med 2001, 29: 2205-2207. 10.1097/00003246-200111000-00025CrossRefPubMed
12.
go back to reference Maser RE, Butler MA, Decherney GS: Use of arterial blood with bedside glucose reflectance meters in an intensive care unit: are they accurate? Crit Care Med 1994, 22: 595-599.CrossRefPubMed Maser RE, Butler MA, Decherney GS: Use of arterial blood with bedside glucose reflectance meters in an intensive care unit: are they accurate? Crit Care Med 1994, 22: 595-599.CrossRefPubMed
13.
go back to reference Karcher RE, Ingram RL, Kiechle FL, Sykes E: Comparison of the HomoCue berta-glucose photometer and reflotron for open heart surgery. Am J Clin Pathol 1993, 100: 130-134.PubMed Karcher RE, Ingram RL, Kiechle FL, Sykes E: Comparison of the HomoCue berta-glucose photometer and reflotron for open heart surgery. Am J Clin Pathol 1993, 100: 130-134.PubMed
14.
go back to reference Kurahashi K, Maruta H, Usuda Y, Ohtsuka M: Influence of blood sample oxygen tension on blood glucose concentration measured using an enzyme-electrode method. Crit Care Med 1997, 25: 231-235. 10.1097/00003246-199702000-00006CrossRefPubMed Kurahashi K, Maruta H, Usuda Y, Ohtsuka M: Influence of blood sample oxygen tension on blood glucose concentration measured using an enzyme-electrode method. Crit Care Med 1997, 25: 231-235. 10.1097/00003246-199702000-00006CrossRefPubMed
15.
go back to reference Zöller C, Goetz AE, Weis M, Mörstedt K, Pichler B, Lamm P, Kelger E, Haller M: Continuous cardiac output measurements do not agree with conventional bolus thermodilution cardiac output determination. Can J Anaesth 2001, 48: 1143-1147.CrossRef Zöller C, Goetz AE, Weis M, Mörstedt K, Pichler B, Lamm P, Kelger E, Haller M: Continuous cardiac output measurements do not agree with conventional bolus thermodilution cardiac output determination. Can J Anaesth 2001, 48: 1143-1147.CrossRef
16.
go back to reference Fogh-Andersen N, Wimberley PD, Thode J, Siggard-Andersen O: Direct reading glucose electrodes detect the molality of glucose in plasma and whole blood. Clin Chim Acta 1990, 189: 33-38. 10.1016/0009-8981(90)90232-HCrossRefPubMed Fogh-Andersen N, Wimberley PD, Thode J, Siggard-Andersen O: Direct reading glucose electrodes detect the molality of glucose in plasma and whole blood. Clin Chim Acta 1990, 189: 33-38. 10.1016/0009-8981(90)90232-HCrossRefPubMed
17.
go back to reference Kuwa K, Nakayama T, Hoshino T, Tominaga M: Relationships of glucose concentrations in capillary whole blood, venous whole blood and venous plasma. Clin Chim Acta 2001, 307: 187-192. 10.1016/S0009-8981(01)00426-0CrossRefPubMed Kuwa K, Nakayama T, Hoshino T, Tominaga M: Relationships of glucose concentrations in capillary whole blood, venous whole blood and venous plasma. Clin Chim Acta 2001, 307: 187-192. 10.1016/S0009-8981(01)00426-0CrossRefPubMed
18.
go back to reference Savolainen K, Vitala A, Puhakainen E, Väisänen M: Problems with the use of whole blood as a sample material in novel direct glucose analysers. Scand J Clin Lab Invest 1990, 50: 221-223.CrossRefPubMed Savolainen K, Vitala A, Puhakainen E, Väisänen M: Problems with the use of whole blood as a sample material in novel direct glucose analysers. Scand J Clin Lab Invest 1990, 50: 221-223.CrossRefPubMed
19.
go back to reference Diaz-Parejo P, Stahl N, Xu W, Reinstrup P, Ungerstedt U, Nodstrom CH: Cerebral energy metabolism during transient hyperglycaemia in patients with severe brain trauma. Intensive Care Med 2003, 29: 544-550.PubMed Diaz-Parejo P, Stahl N, Xu W, Reinstrup P, Ungerstedt U, Nodstrom CH: Cerebral energy metabolism during transient hyperglycaemia in patients with severe brain trauma. Intensive Care Med 2003, 29: 544-550.PubMed
Metadata
Title
Initial distribution volume of glucose can be approximated using a conventional glucose analyzer in the intensive care unit
Authors
Hironori Ishihara
Hitomi Nakamura
Hirobumi Okawa
Hajime Takase
Toshihito Tsubo
Kazuyoshi Hirota
Publication date
01-04-2005
Publisher
BioMed Central
Published in
Critical Care / Issue 2/2005
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc3047

Other articles of this Issue 2/2005

Critical Care 2/2005 Go to the issue