Influence of calibration on digital templating of hip arthroplasty

Authors: Christoph Kolja Boese, Sebastian Wilhelm, Stefan Haneder, Philipp Lechler, Peer Eysel, Jan Bredow

Published in: International Orthopaedics | Issue 8/2019

Login to get access

Abstract

Introduction

Digital templating for total joint replacement is the current standard. For image calibration, external calibration markers (ECM) are used. However, there are concerns regarding the precision of the method. This study aimed to identify the direct influence of calibration errors on digital templating.

Patients and methods

A retrospective analysis of 100 post-operative radiographs with unilateral total hip arthroplasty was performed. The magnification factor of the ECM and of the internal prosthetic femoral head (ICM) as a reference value was calculated for each radiograph. Two blinded observers performed templating of the contralateral hip using a randomized list for all radiographs and both markers. The component size templated by the ECM magnification was compared to the reference by the ICM magnification.

Results

Mean magnification factors of ICM and ECM differed significantly (p = 0.006). The absolute difference was 5.2% (range 0.0–23.3%, SD 4.8%). Templating of the acetabular or the femoral component showed no significant differences (p = 0.120, p = 0.599). Differences of more than one size were found in 26% of the acetabular components and 14% of the femoral components and differences over two sizes in 10% respectively 3%. Correlation coefficients for magnification error and size differences of acetabular components were − 0.645 (p < 0.001) and for the femoral component − 0.607 (p < 0.001).

Interpretation

The calibration error of external calibration markers in digital templating for hip replacement influences component sizes significantly. Thus, correct positioning of ECM is of utmost importance.
Literature
1.
go back to reference Shaarani SR, McHugh G, Collins DA (2013) Accuracy of digital preoperative templating in 100 consecutive uncemented total hip arthroplasties: a single surgeon series. J Arthroplasty 28(2):331–337CrossRefPubMed Shaarani SR, McHugh G, Collins DA (2013) Accuracy of digital preoperative templating in 100 consecutive uncemented total hip arthroplasties: a single surgeon series. J Arthroplasty 28(2):331–337CrossRefPubMed
2.
go back to reference Boese CK, Lechler P, Rose L, Dargel J, Oppermann J, Eysel P et al (2015) Calibration markers for digital templating in total hip arthroplasty. PLoS One 10(7):e0128529CrossRefPubMedPubMedCentral Boese CK, Lechler P, Rose L, Dargel J, Oppermann J, Eysel P et al (2015) Calibration markers for digital templating in total hip arthroplasty. PLoS One 10(7):e0128529CrossRefPubMedPubMedCentral
3.
go back to reference Boese CK, Bredow J, Dargel J, Eysel P, Geiges H, Lechler P (2016) Calibration marker position in digital templating of total hip arthroplasty. J Arthroplast 31(4):883–887CrossRef Boese CK, Bredow J, Dargel J, Eysel P, Geiges H, Lechler P (2016) Calibration marker position in digital templating of total hip arthroplasty. J Arthroplast 31(4):883–887CrossRef
4.
go back to reference Franken M, Grimm B, Heyligers I (2010) A comparison of four systems for calibration when templating for total hip replacement with digital radiography. J Bone Joint Surg Br 92(1):136–141CrossRefPubMed Franken M, Grimm B, Heyligers I (2010) A comparison of four systems for calibration when templating for total hip replacement with digital radiography. J Bone Joint Surg Br 92(1):136–141CrossRefPubMed
5.
go back to reference Sinclair VF, Wilson J, Jain NP, Knowles D (2014) Assessment of accuracy of marker ball placement in pre-operative templating for total hip arthroplasty. J Arthroplast 29(8):1658–1660CrossRef Sinclair VF, Wilson J, Jain NP, Knowles D (2014) Assessment of accuracy of marker ball placement in pre-operative templating for total hip arthroplasty. J Arthroplast 29(8):1658–1660CrossRef
6.
go back to reference Archibeck MJ, Tripuraneni KR, Carothers JT, Junick DW, Munson NR, Murray-Krezan CM (2017) Prospective, randomized, surgeon-blinded comparison of standard magnification assumption vs magnification marker usage for preoperative templating in total hip arthroplasty. J Arthroplast 32(10):3061–3064CrossRef Archibeck MJ, Tripuraneni KR, Carothers JT, Junick DW, Munson NR, Murray-Krezan CM (2017) Prospective, randomized, surgeon-blinded comparison of standard magnification assumption vs magnification marker usage for preoperative templating in total hip arthroplasty. J Arthroplast 32(10):3061–3064CrossRef
7.
go back to reference Efe T, El Zayat BF, Heyse TJ, Timmesfeld N, Fuchs-Winkelmann S, Schmitt J (2011) Precision of preoperative digital templating in total hip arthroplasty. Acta Orthop Belg 77(5):616–621PubMed Efe T, El Zayat BF, Heyse TJ, Timmesfeld N, Fuchs-Winkelmann S, Schmitt J (2011) Precision of preoperative digital templating in total hip arthroplasty. Acta Orthop Belg 77(5):616–621PubMed
8.
go back to reference Iorio R, Siegel J, Specht LM, Tilzey JF, Hartman A, Healy WL (2009) A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe? J Arthroplasty 24(2):175–179CrossRefPubMed Iorio R, Siegel J, Specht LM, Tilzey JF, Hartman A, Healy WL (2009) A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe? J Arthroplasty 24(2):175–179CrossRefPubMed
10.
go back to reference Baxter JA, Barlow T, Karthikeyan S, Mayo DJ, King RJ (2012) The accuracy of automatic calibration of digital pelvic radiographs using two different scale markers: a comparative study. Hip Int 22(1):82–89CrossRefPubMed Baxter JA, Barlow T, Karthikeyan S, Mayo DJ, King RJ (2012) The accuracy of automatic calibration of digital pelvic radiographs using two different scale markers: a comparative study. Hip Int 22(1):82–89CrossRefPubMed
11.
go back to reference Bayne CO, Krosin M, Barber TC (2009) Evaluation of the accuracy and use of x-ray markers in digital templating for total hip arthroplasty. J Arthroplast 24(3):407–413CrossRef Bayne CO, Krosin M, Barber TC (2009) Evaluation of the accuracy and use of x-ray markers in digital templating for total hip arthroplasty. J Arthroplast 24(3):407–413CrossRef
12.
go back to reference Kniesel B, Konstantinidis L, Hirschmuller A, Sudkamp N, Helwig P (2014) Digital templating in total knee and hip replacement: an analysis of planning accuracy. Int Orthop 38(4):733–739CrossRefPubMed Kniesel B, Konstantinidis L, Hirschmuller A, Sudkamp N, Helwig P (2014) Digital templating in total knee and hip replacement: an analysis of planning accuracy. Int Orthop 38(4):733–739CrossRefPubMed
13.
go back to reference Lakstein D, Bachar I, Debi R, Lubovsky O, Cohen O, Tan Z et al (2017) Radiographic templating of total hip arthroplasty for femoral neck fractures. Int Orthop 41(4):831–836CrossRefPubMed Lakstein D, Bachar I, Debi R, Lubovsky O, Cohen O, Tan Z et al (2017) Radiographic templating of total hip arthroplasty for femoral neck fractures. Int Orthop 41(4):831–836CrossRefPubMed
14.
go back to reference The B, Diercks RL, van Ooijen PM, van Horn JR (2005) Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees. Acta Orthop 76(1):78–84CrossRefPubMed The B, Diercks RL, van Ooijen PM, van Horn JR (2005) Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees. Acta Orthop 76(1):78–84CrossRefPubMed
15.
go back to reference Gamble P, de Beer J, Petruccelli D, Winemaker M (2010) The accuracy of digital templating in uncemented total hip arthroplasty. J Arthroplast 25(4):529–532CrossRef Gamble P, de Beer J, Petruccelli D, Winemaker M (2010) The accuracy of digital templating in uncemented total hip arthroplasty. J Arthroplast 25(4):529–532CrossRef
17.
go back to reference Ohmori T, Kabata T, Kajino Y, Taga T, Hasegawa K, Inoue D et al (2018) Differences in range of motion with the same combined anteversion after total hip arthroplasty. Int Orthop 42(5):1021–1028CrossRefPubMed Ohmori T, Kabata T, Kajino Y, Taga T, Hasegawa K, Inoue D et al (2018) Differences in range of motion with the same combined anteversion after total hip arthroplasty. Int Orthop 42(5):1021–1028CrossRefPubMed
Metadata
Title
Influence of calibration on digital templating of hip arthroplasty
Authors
Christoph Kolja Boese
Sebastian Wilhelm
Stefan Haneder
Philipp Lechler
Peer Eysel
Jan Bredow
Publication date
01-08-2019
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 8/2019
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-018-4120-7

Other articles of this Issue 8/2019

International Orthopaedics 8/2019 Go to the issue