Abstract

Background

Four-dimensional hysterosalpingo-contrast sonography (4D-HyCoSy) is the preferred way for evaluating fallopian tubal patency and it associated with higher rate of spontaneous conception. However, Few studies have evaluated the influencing factors of spontaneous conception in 4D-HyCoSy and suggested ways to choose treatment options after 4D-HyCoSy. The study was to evaluate the correlation between spontaneous conception outcome and the patients’ clinical characteristics as well as tubal patency in infertile women to provide reference on ways to manage the patient after 4D-HyCoSy.

Methods

This was a retrospective study and analysis of two hundred and eighty three (283) infertile patients who underwent a 4D-HyCoSy between December 2014 and October 2017 in our center. Eligible patients were those whose partners semen parameters were normal when based on World Health Organization (WHO) criteria, and had spontaneous conception without clinical interventions after 4D-HyCoSy.

Result(s)

One hundred and sixteen patients (40.9%) conceived spontaneously and the mean conception time was (8.8 ± 0.3) months. Within a year after 4D-HyCoSy, the spontaneous conception rate was highest in type VI(62.5%), followed by type IV (46.2%), type III (44.4%), type V (39.4%), type II (33.9%) and type I (14.8%). With Cox regression analysis, two factors associated with spontaneous conception outcome appeared to increase spontaneous conception rate: patients with type IV or type VI tubes and duration of infertility less than 2 years. The age, type of infertility, multiparas, history of pelvic surgery, history of uterine cavity operation, uterine fibromyomata and polycystic ovary were unrelated to spontaneous conception outcome after 4D-HyCoSy.

Conclusion(s)

This study showed that some infertile women could succeed in spontaneous conception after 4D-HyCoSy. Hence, We recommend the usage of 4D-HyCoSy as first line for tubal patency test and infertile patients should be advised to accept 4D-HyCoSy examination as soon as possible. Expectant treatment of about 8–9 months is reported to be feasible for infertile women whose 4D-HyCoSy findings showed one tube patency or poor patency. Alternatively, an immediate clinical intervention is recommended for those with bilateral obstructed tubes .
Literature
1.
go back to reference Hajishafiha M, Zobairi T, Zanjani VR, Ghasemi-Rad M, Yekta Z, Mladkova N. Diagnostic value of sonohysterography in the determination of fallopian tube patency as an initial step of routine infertility assessment. J Ultrasound Med. 2009;28(12):1671–7.CrossRef Hajishafiha M, Zobairi T, Zanjani VR, Ghasemi-Rad M, Yekta Z, Mladkova N. Diagnostic value of sonohysterography in the determination of fallopian tube patency as an initial step of routine infertility assessment. J Ultrasound Med. 2009;28(12):1671–7.CrossRef
2.
go back to reference He Y, Geng Q, Liu H, Han X. First experience using 4-dimensional hysterosalpingo-contrast sonography with SonoVue for assessing fallopian tube patency. J Ultrasound Med. 2013;32(7):1233–43.CrossRef He Y, Geng Q, Liu H, Han X. First experience using 4-dimensional hysterosalpingo-contrast sonography with SonoVue for assessing fallopian tube patency. J Ultrasound Med. 2013;32(7):1233–43.CrossRef
3.
go back to reference Chen F, Quan J, Huang P, You X. Hysterosalpingo-contrast Sonography with four-dimensional technique for screening fallopian tubal patency: Let's make an exploration. J Minim Invasive Gynecol. 2017;24(3):407–14.CrossRef Chen F, Quan J, Huang P, You X. Hysterosalpingo-contrast Sonography with four-dimensional technique for screening fallopian tubal patency: Let's make an exploration. J Minim Invasive Gynecol. 2017;24(3):407–14.CrossRef
4.
go back to reference Giugliano E, Cagnazzo E, Bazzan E, Patella A, Marci R. Hysterosalpingo-contrast sonography: is possible to quantify the therapeutic effect of a diagnostic test? Clin Exp Reprod Med. 2012;39(4):161–5.CrossRef Giugliano E, Cagnazzo E, Bazzan E, Patella A, Marci R. Hysterosalpingo-contrast sonography: is possible to quantify the therapeutic effect of a diagnostic test? Clin Exp Reprod Med. 2012;39(4):161–5.CrossRef
5.
go back to reference Mandia L, Personeni C, Antonazzo P, Angileri SA, Pinto A, Savasi V. Ultrasound in. Infertility. Setting: Optimal strategy to evaluate the assessment of Tubal Patency. Biomed Res Int. 2017;2017:3205895.CrossRef Mandia L, Personeni C, Antonazzo P, Angileri SA, Pinto A, Savasi V. Ultrasound in. Infertility. Setting: Optimal strategy to evaluate the assessment of Tubal Patency. Biomed Res Int. 2017;2017:3205895.CrossRef
6.
go back to reference Rajesh H, Lim SL, Yu SL. Hysterosalpingo-foam sonography: patient selection and. Perspectives. Int J Women's Health. 2017;9:23–32.CrossRef Rajesh H, Lim SL, Yu SL. Hysterosalpingo-foam sonography: patient selection and. Perspectives. Int J Women's Health. 2017;9:23–32.CrossRef
7.
go back to reference Promberger R, Simek IM, Nouri K, Obermaier K, Kurz C, Ott J. Accuracy of tubal patency assessment in diagnostic hysteroscopy compared with laparoscopy in infertile women: a retrospective cohort study. J Minim Invasive Gynecol. 2018;25(5):794–9.CrossRef Promberger R, Simek IM, Nouri K, Obermaier K, Kurz C, Ott J. Accuracy of tubal patency assessment in diagnostic hysteroscopy compared with laparoscopy in infertile women: a retrospective cohort study. J Minim Invasive Gynecol. 2018;25(5):794–9.CrossRef
8.
go back to reference Saunders RD, Shwayder JM, Nakajima ST. Current methods of tubal patency assessment. Fertil Steril. 2011;95(7):2171–9.CrossRef Saunders RD, Shwayder JM, Nakajima ST. Current methods of tubal patency assessment. Fertil Steril. 2011;95(7):2171–9.CrossRef
9.
go back to reference Kiyokawa K, Masuda H, Fuyuki T, Koseki M, Uchida N, Fukuda T, Amemiya K, Shouka K, Suzuki K. Three-dimensional hysterosalpingo-contrast sonography (3D-HyCoSy) as an outpatient procedure to assess infertile women: a pilot study. Ultrasound Obstet Gynecol. 2000;16(7):648–54.CrossRef Kiyokawa K, Masuda H, Fuyuki T, Koseki M, Uchida N, Fukuda T, Amemiya K, Shouka K, Suzuki K. Three-dimensional hysterosalpingo-contrast sonography (3D-HyCoSy) as an outpatient procedure to assess infertile women: a pilot study. Ultrasound Obstet Gynecol. 2000;16(7):648–54.CrossRef
10.
go back to reference Zhou L, Zhang X, Chen X, Liao L, Pan R, Zhou N, Di N. Value of three-dimensional hysterosalpingo-contrast sonography with SonoVue in the assessment of tubal patency. Ultrasound Obstet Gynecol. 2012;40(1):93–8.CrossRef Zhou L, Zhang X, Chen X, Liao L, Pan R, Zhou N, Di N. Value of three-dimensional hysterosalpingo-contrast sonography with SonoVue in the assessment of tubal patency. Ultrasound Obstet Gynecol. 2012;40(1):93–8.CrossRef
11.
go back to reference He Y, Ma X, Xu J, Li S, Wu H, Liu Q, Kong L, Luo J, Liu H. Comparison of assessment methods for fallopian tubal patency and Peritubal adhesion between Transvaginal 4-dimensional Hysterosalpingo-contrast Sonography and laparoscopic Chromopertubation. J Ultrasound Med. 2017;36(3):547–56.CrossRef He Y, Ma X, Xu J, Li S, Wu H, Liu Q, Kong L, Luo J, Liu H. Comparison of assessment methods for fallopian tubal patency and Peritubal adhesion between Transvaginal 4-dimensional Hysterosalpingo-contrast Sonography and laparoscopic Chromopertubation. J Ultrasound Med. 2017;36(3):547–56.CrossRef
12.
go back to reference Wang W, Zhou Q, Gong Y, Li Y, Huang Y, Chen Z. Assessment of fallopian tube Fimbria patency with 4-dimensional Hysterosalpingo-contrast Sonography in infertile women. J Ultrasound Med. 2017;36(10):2061–9.CrossRef Wang W, Zhou Q, Gong Y, Li Y, Huang Y, Chen Z. Assessment of fallopian tube Fimbria patency with 4-dimensional Hysterosalpingo-contrast Sonography in infertile women. J Ultrasound Med. 2017;36(10):2061–9.CrossRef
13.
go back to reference Li H, Zhang M, Qiang Y, Ma Y, Mao S, Zhang H. Pain and side effects associated with 4-dimensional hysterosalpingo-contrast sonography for evaluating of the fallopian tubes patency. Comput Assist Surg (Abingdon). 2017;22(sup1):93–9.CrossRef Li H, Zhang M, Qiang Y, Ma Y, Mao S, Zhang H. Pain and side effects associated with 4-dimensional hysterosalpingo-contrast sonography for evaluating of the fallopian tubes patency. Comput Assist Surg (Abingdon). 2017;22(sup1):93–9.CrossRef
14.
go back to reference Shi J, Li S, Wu H, He Y, Yi W, Xu J, Liu H, Guan Y. The influencing factors of venous Intravasation during Transvaginal four-dimensional Hysterosalpingo-contrast Sonography with SonoVue. Ultrasound Med Biol. 2019;45(9):2273–80.CrossRef Shi J, Li S, Wu H, He Y, Yi W, Xu J, Liu H, Guan Y. The influencing factors of venous Intravasation during Transvaginal four-dimensional Hysterosalpingo-contrast Sonography with SonoVue. Ultrasound Med Biol. 2019;45(9):2273–80.CrossRef
15.
go back to reference Chunyan G, Bin P, Ping Y, Yue Z, Yang X, Hongju T, Li S, Xi X. Assessment of the. Influence on Spontaneous Pregnancy of Hysterosalpingo-Contrast Sonography. Biomed Res Int. 2018;2018:4901281.CrossRef Chunyan G, Bin P, Ping Y, Yue Z, Yang X, Hongju T, Li S, Xi X. Assessment of the. Influence on Spontaneous Pregnancy of Hysterosalpingo-Contrast Sonography. Biomed Res Int. 2018;2018:4901281.CrossRef
16.
go back to reference Lindborg L, Thorburn J, Bergh C, Strandell A. Influence of HyCoSy on spontaneous pregnancy: a randomized controlled trial. Hum Reprod. 2009;24(5):1075–9.CrossRef Lindborg L, Thorburn J, Bergh C, Strandell A. Influence of HyCoSy on spontaneous pregnancy: a randomized controlled trial. Hum Reprod. 2009;24(5):1075–9.CrossRef
17.
go back to reference He Y, Wu H, Xiong R, Liu H, Shi J, Xu J, Zhang N, Liu Y. Intravasation affects the diagnostic image quality of Transvaginal 4-dimensional Hysterosalpingo-contrast Sonography with SonoVue. J Ultrasound Med. 2019;38(8):2169–80.CrossRef He Y, Wu H, Xiong R, Liu H, Shi J, Xu J, Zhang N, Liu Y. Intravasation affects the diagnostic image quality of Transvaginal 4-dimensional Hysterosalpingo-contrast Sonography with SonoVue. J Ultrasound Med. 2019;38(8):2169–80.CrossRef
18.
go back to reference Emanuel MH, van Vliet M, Weber M, Exalto N. First experiences with hysterosalpingo-foam sonography (HyFoSy) for office tubal patency testing. Hum Reprod. 2012;27(1):114–7.CrossRef Emanuel MH, van Vliet M, Weber M, Exalto N. First experiences with hysterosalpingo-foam sonography (HyFoSy) for office tubal patency testing. Hum Reprod. 2012;27(1):114–7.CrossRef
19.
go back to reference Fang F, Bai Y, Zhang Y, Faramand A. Oil-based versus water-based contrast for hysterosalpingography in infertile women: a systematic review and meta-analysis of randomized controlled trials. Fertil Steril. 2018;110(1):153–60.CrossRef Fang F, Bai Y, Zhang Y, Faramand A. Oil-based versus water-based contrast for hysterosalpingography in infertile women: a systematic review and meta-analysis of randomized controlled trials. Fertil Steril. 2018;110(1):153–60.CrossRef
20.
go back to reference Practice Committee of the American Society for Reproductive M. Role of tubal surgery in the era of assisted reproductive technology: a committee opinion. Fertil Steril. 2015;103(6):e37–43.CrossRef Practice Committee of the American Society for Reproductive M. Role of tubal surgery in the era of assisted reproductive technology: a committee opinion. Fertil Steril. 2015;103(6):e37–43.CrossRef
21.
go back to reference Al-Omari MH, Obeidat N, Elheis M, Khasawneh RA, Gharaibeh MM. Factors affecting pregnancy rate following fallopian tube recanalization in women with proximal fallopian tube obstruction. J Clin Med. 2018;7(5):110.CrossRef Al-Omari MH, Obeidat N, Elheis M, Khasawneh RA, Gharaibeh MM. Factors affecting pregnancy rate following fallopian tube recanalization in women with proximal fallopian tube obstruction. J Clin Med. 2018;7(5):110.CrossRef
Metadata
Title
Spontaneous conception outcome in infertile women after four-dimensional hysterosalpingo-contrast-sonography
Authors
Yu Liu
Ning Zhang
Yanni He
Jiayao Shi
Meijun Zhou
Jingjiao Xu
Hongmei Liu
Publication date
01-12-2020
Publisher
BioMed Central
Published in
BMC Pregnancy and Childbirth / Issue 1/2020
Electronic ISSN: 1471-2393
DOI
https://doi.org/10.1186/s12884-020-03315-x

Other articles of this Issue 1/2020

BMC Pregnancy and Childbirth 1/2020 Go to the issue