Skip to main content
Top
Published in: European Archives of Oto-Rhino-Laryngology 5/2004

01-05-2004 | Miscellaneous

Individual prefabricated titanium implants and titanium mesh in skull base reconstructive surgery. A report of cases

Authors: J. Schipper, G. J. Ridder, U. Spetzger, C. B. Teszler, M. Fradis, W. Maier

Published in: European Archives of Oto-Rhino-Laryngology | Issue 5/2004

Login to get access

Abstract

Titanium implants can be shaped by traditional hand forming, press shaping, modular construction by welding, construction on full-size models shaped from CT coordinates and, most recently, by computer-assisted design and computer-assisted manufacturing (CAD/CAM) that consist in the direct prefabrication of individual implants by milling them out of a solid block of titanium. The aim of our study was to present a set of preliminary cases of an ongoing program of reconstructive procedures of the skull base using titanium implants. The subjects underwent ablative procedures of the skull base with reconstruction either by titanium mesh or individual prefabricated CAD/CAM implants. Six patients have been operated on successfully since 2000: two received prefabricated CAD/CAM titanium plates and four others underwent reconstruction with titanium mesh. The stability of CAD/CAM plates is superior to that of mesh, thus it is more useful in reconstructing large lesions of the frontal skull base and the temporal and occipital bones. Titanium mesh was successfully used for defects smaller than 100 cm2 or where selected viscerocranial defects are complicated in design and less reproducible by CAD/CAM. The intraoperative design, shaping and adjustment characteristic of titanium mesh can be dispensed with when CAD/CAM implants are used. The 3-D data set used in the CAD/CAM process also operates in the navigated simulation and planning of the ablation contours, the latter being of great assistance in establishing the optimal future defect. As a disadvantage, CAD/CAM technology is more expensive than titanium mesh, and the process is time-consuming as it is carried out in advance of surgery.
Literature
1.
go back to reference Badie B, Preston JK, Hartig GK (2000) Use of titanium mesh for reconstruction of large anterior cranial base defects. J Neurosurg 93:711–714PubMed Badie B, Preston JK, Hartig GK (2000) Use of titanium mesh for reconstruction of large anterior cranial base defects. J Neurosurg 93:711–714PubMed
2.
go back to reference Blake GB, MacFarlane MR, Hinton JW (1990) Titanium in reconstructive surgery of the skull and face. Br J Plast Surg 43:528–535PubMed Blake GB, MacFarlane MR, Hinton JW (1990) Titanium in reconstructive surgery of the skull and face. Br J Plast Surg 43:528–535PubMed
3.
go back to reference Bücheler M, Weihe S, Eufinger H, Wehmöller M, Bootz F (2002) Reconstruction of the frontal bone with individual titanium implants after surgical therapy of osteomyelitis of the frontal bone (in German). HNO 50:339–346CrossRef Bücheler M, Weihe S, Eufinger H, Wehmöller M, Bootz F (2002) Reconstruction of the frontal bone with individual titanium implants after surgical therapy of osteomyelitis of the frontal bone (in German). HNO 50:339–346CrossRef
4.
go back to reference Cutting C, Bookstein FL, Grayson B, Fellingham L, McCarthy JG (1986) Three-dimensional computer-assisted design of craniofacial surgical procedures: optimization and interaction with cephalometric and CT-based models. Plast Reconstr Surg 77:877–887PubMed Cutting C, Bookstein FL, Grayson B, Fellingham L, McCarthy JG (1986) Three-dimensional computer-assisted design of craniofacial surgical procedures: optimization and interaction with cephalometric and CT-based models. Plast Reconstr Surg 77:877–887PubMed
5.
go back to reference Dacho A, Steffen H, Ziegler CM, Conradt C, Dietz A (2002) Orbital floor reconstruction. Comparison of a new perforated 0.15-mm thick PDS layer with established titanium dynamic mesh (in German). HNO 50:21–28CrossRef Dacho A, Steffen H, Ziegler CM, Conradt C, Dietz A (2002) Orbital floor reconstruction. Comparison of a new perforated 0.15-mm thick PDS layer with established titanium dynamic mesh (in German). HNO 50:21–28CrossRef
6.
go back to reference Eufinger H, Wehmöller M (1998) Individual prefabricated titanium implants in reconstructive craniofacial surgery: clinical and technical aspects of the first 22 cases. Plast Reconstr Surg 102:300–308PubMed Eufinger H, Wehmöller M (1998) Individual prefabricated titanium implants in reconstructive craniofacial surgery: clinical and technical aspects of the first 22 cases. Plast Reconstr Surg 102:300–308PubMed
7.
go back to reference Eufinger H, Wehmöller M, Machtens E, Heuser L, Harders A, Kruse D (1995) Reconstruction of craniofacial bone defects with individual alloplastic implants based on CAD/CAM-manipulated CT-data. J Craniomaxillofac Surg 23:175–181PubMed Eufinger H, Wehmöller M, Machtens E, Heuser L, Harders A, Kruse D (1995) Reconstruction of craniofacial bone defects with individual alloplastic implants based on CAD/CAM-manipulated CT-data. J Craniomaxillofac Surg 23:175–181PubMed
8.
go back to reference Eufinger H, Wittkampf AR, Wehmöller M, Zonneveld FW (1998) Single-step fronto-orbital resection and reconstruction with individual resection template and corresponding titanium implant: a new method of computer-aided surgery. J Craniomaxillofac Surg 26:373–378PubMed Eufinger H, Wittkampf AR, Wehmöller M, Zonneveld FW (1998) Single-step fronto-orbital resection and reconstruction with individual resection template and corresponding titanium implant: a new method of computer-aided surgery. J Craniomaxillofac Surg 26:373–378PubMed
9.
go back to reference Gear AJ, Lokeh A, Aldridge JH, Migliori MR, Benjamin CI, Schubert W (2002) Safety of titanium mesh for orbital reconstruction. Ann Plast Surg 48:1–7PubMed Gear AJ, Lokeh A, Aldridge JH, Migliori MR, Benjamin CI, Schubert W (2002) Safety of titanium mesh for orbital reconstruction. Ann Plast Surg 48:1–7PubMed
10.
go back to reference Joffe J, Harris M, Kahugu F, Nicoll S, Linney A, Richards R (1999) A prospective study of computer-aided design and manufacture of titanium plate for cranioplasty and its clinical outcome. Br J Neurosurg 13:576–580CrossRefPubMed Joffe J, Harris M, Kahugu F, Nicoll S, Linney A, Richards R (1999) A prospective study of computer-aided design and manufacture of titanium plate for cranioplasty and its clinical outcome. Br J Neurosurg 13:576–580CrossRefPubMed
11.
go back to reference Lambrecht JT, Brix F (1990) Individual skull model fabrication for craniofacial surgery. Cleft Palate J 27:382–385PubMed Lambrecht JT, Brix F (1990) Individual skull model fabrication for craniofacial surgery. Cleft Palate J 27:382–385PubMed
12.
go back to reference Lazaridis N, Makos C, Iordanidis S, Zouloumis L (1998) The use of titanium mesh sheet in fronto-zygomatic-orbital region. Case reports. Aust Dent J 43:223–228PubMed Lazaridis N, Makos C, Iordanidis S, Zouloumis L (1998) The use of titanium mesh sheet in fronto-zygomatic-orbital region. Case reports. Aust Dent J 43:223–228PubMed
13.
go back to reference Maier W, Laszig R (1998) Complications of endonasal paranasal sinus surgery—diagnostic and therapeutic consequences (in German). Laryngorhinootologie 77:402–409PubMed Maier W, Laszig R (1998) Complications of endonasal paranasal sinus surgery—diagnostic and therapeutic consequences (in German). Laryngorhinootologie 77:402–409PubMed
14.
go back to reference Manolidis S, Weeks BH, Kirby M, Scarlett M, Hollier L (2002) Classification and surgical management of orbital fractures: experience with 111 orbital reconstructions. J Craniofac Surg 13:726–737PubMed Manolidis S, Weeks BH, Kirby M, Scarlett M, Hollier L (2002) Classification and surgical management of orbital fractures: experience with 111 orbital reconstructions. J Craniofac Surg 13:726–737PubMed
15.
go back to reference Schramm A, Gellrich NC, Gutwald R, Schipper J, Bloss H, Hustedt H, Schmelzeisen R, Otten JE (2000) Indications for computer-assisted treatment of cranio-maxillofacial tumors. Comput Aided Surg 5:343–352CrossRefPubMed Schramm A, Gellrich NC, Gutwald R, Schipper J, Bloss H, Hustedt H, Schmelzeisen R, Otten JE (2000) Indications for computer-assisted treatment of cranio-maxillofacial tumors. Comput Aided Surg 5:343–352CrossRefPubMed
16.
go back to reference Sugar AW, Kuriakose M, Walshaw ND (1992) Titanium mesh in orbital wall reconstruction. Int J Oral Maxillofac Surg 21:140–144 Sugar AW, Kuriakose M, Walshaw ND (1992) Titanium mesh in orbital wall reconstruction. Int J Oral Maxillofac Surg 21:140–144
17.
go back to reference Wehmöller M, Eufinger H, Kruse D, Massberg W (1995) CAD by processing of computed tomography data and CAM of individually designed prostheses. Int J Oral Maxillofac Surgery 24:90–97 Wehmöller M, Eufinger H, Kruse D, Massberg W (1995) CAD by processing of computed tomography data and CAM of individually designed prostheses. Int J Oral Maxillofac Surgery 24:90–97
18.
go back to reference Zonneveld FW (1994) A decade of clinical three-dimensional imaging: a review. Part III. Image analysis and interaction, display options, and physical models. Invest Radiol 29:716–725PubMed Zonneveld FW (1994) A decade of clinical three-dimensional imaging: a review. Part III. Image analysis and interaction, display options, and physical models. Invest Radiol 29:716–725PubMed
Metadata
Title
Individual prefabricated titanium implants and titanium mesh in skull base reconstructive surgery. A report of cases
Authors
J. Schipper
G. J. Ridder
U. Spetzger
C. B. Teszler
M. Fradis
W. Maier
Publication date
01-05-2004
Publisher
Springer-Verlag
Published in
European Archives of Oto-Rhino-Laryngology / Issue 5/2004
Print ISSN: 0937-4477
Electronic ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-003-0686-8

Other articles of this Issue 5/2004

European Archives of Oto-Rhino-Laryngology 5/2004 Go to the issue