Background

Transverse sternal nonunion is a rare but disabling complication of chest trauma or a transverse sternotomy. Fixation methods, mainly used to manage the more common longitudinal sternal nonunion, often fail, leaving the surgical treatment of transverse nonunion to be a challenge.

Case presentation

We present a case of a highly-disabling, postoperative chest wall defect resulting from transverse sternal nonunion after a transverse thoracosternotomy (clamshell incision) and a concomitant rib resection. Following unsuccessful surgical attempts, the sternal nonunion was fixed with a tibial locking plate and bone grafted, while the post-rib resection chest defect was reconstructed with a Gore-Tex dual mesh membrane. Adequate chest stability was achieved, enabling complete healing of the sternal nonunion and the patient’s complete recovery.

Conclusion

We believe it is important to address both in the rare case of combined postoperative transverse sternal nonunion and the chest wall defect after rib resection. A good outcome was achieved in our patient by fixing the nonunion with an appropriately sized and shaped locking plate with bone grafting and covering the chest defect with a dual mesh membrane.
Literature
1.
go back to reference Bertin KC, Rice RS, Doty DB, Jones KW. Repair of transverse sternal nonunions using metal plates and autogenous bone graft. Ann Thorac Surg. 2002;73:1661–2.CrossRef Bertin KC, Rice RS, Doty DB, Jones KW. Repair of transverse sternal nonunions using metal plates and autogenous bone graft. Ann Thorac Surg. 2002;73:1661–2.CrossRef
2.
go back to reference Queitsch C, Kienast B, Voigt C, Gille J, Jürgens C, Arndt PS. Treatment of posttraumatic sternal non-union with a locked sternum-osteosynthesis plate (TiFix). Injury. 2011;42:44–6.CrossRef Queitsch C, Kienast B, Voigt C, Gille J, Jürgens C, Arndt PS. Treatment of posttraumatic sternal non-union with a locked sternum-osteosynthesis plate (TiFix). Injury. 2011;42:44–6.CrossRef
3.
go back to reference Mayba II. Non-union of fractures of the sternum. J Bone Jt Surg Ser A. 1985;67:1091–3.CrossRef Mayba II. Non-union of fractures of the sternum. J Bone Jt Surg Ser A. 1985;67:1091–3.CrossRef
4.
go back to reference Coons DA, Pitcher JD, Braxton M, Bickley BT. Sternal nonunion. Orthopedics. 2002;25:89–91.CrossRef Coons DA, Pitcher JD, Braxton M, Bickley BT. Sternal nonunion. Orthopedics. 2002;25:89–91.CrossRef
5.
go back to reference Harston A, Roberts C. Fixation of sternal fractures: a systematic review. J Trauma Inj Infect Crit Care. 2011;71:1875–9.CrossRef Harston A, Roberts C. Fixation of sternal fractures: a systematic review. J Trauma Inj Infect Crit Care. 2011;71:1875–9.CrossRef
7.
go back to reference Wu LC, Renucci JD, Song DH. Sternal nonunion: a review of current treatments and a new method of rigid fixation. Ann Plast Surg. 2005;54:55–8.CrossRef Wu LC, Renucci JD, Song DH. Sternal nonunion: a review of current treatments and a new method of rigid fixation. Ann Plast Surg. 2005;54:55–8.CrossRef
8.
go back to reference Motomura T, Bruckner B, La Francesca S, Mittelhaus S, Chike-Obi C, Leon-Becerril J, et al. Experience of sternal secondary closure by means of a titanium fixation system after transverse thoracosternotomy. Artif Organs. 2011;35:E168–73.CrossRef Motomura T, Bruckner B, La Francesca S, Mittelhaus S, Chike-Obi C, Leon-Becerril J, et al. Experience of sternal secondary closure by means of a titanium fixation system after transverse thoracosternotomy. Artif Organs. 2011;35:E168–73.CrossRef
9.
go back to reference Gandy KL, Moulton MJ. Sternal plating to prevent malunion of transverse sternotomy in lung transplantation. Ann Thorac Surg. 2008;86:1384–5.CrossRef Gandy KL, Moulton MJ. Sternal plating to prevent malunion of transverse sternotomy in lung transplantation. Ann Thorac Surg. 2008;86:1384–5.CrossRef
10.
go back to reference Klei DS, de Jong MB, Öner FC, Leenen LPH, van Wessem KJP. Current treatment and outcomes of traumatic sternal fractures—a systematic review. Int Orthop. 2019;43:1455–64.CrossRef Klei DS, de Jong MB, Öner FC, Leenen LPH, van Wessem KJP. Current treatment and outcomes of traumatic sternal fractures—a systematic review. Int Orthop. 2019;43:1455–64.CrossRef
12.
go back to reference Lonchyna VA. Sternal “notching” improves clamshell incision. Oper Tech Thorac Cardiovasc Surg. 1999;4:176–8.CrossRef Lonchyna VA. Sternal “notching” improves clamshell incision. Oper Tech Thorac Cardiovasc Surg. 1999;4:176–8.CrossRef
14.
go back to reference Ma QY, Zhu YJ, Pang LW, Chen G, Chen J, Chen ZM. Application of the titanium plate fixation system in sternum transverse incisions. Am Surg. 2011;77:1477–82.CrossRef Ma QY, Zhu YJ, Pang LW, Chen G, Chen J, Chen ZM. Application of the titanium plate fixation system in sternum transverse incisions. Am Surg. 2011;77:1477–82.CrossRef
15.
go back to reference Ozaki W, Buchman SR, Iannettoni MD, Frankenburg EP. Biomechanical study of sternal closure using rigid fixation techniques in human cadavers. Ann Thorac Surg. 1998;65:1660–5.CrossRef Ozaki W, Buchman SR, Iannettoni MD, Frankenburg EP. Biomechanical study of sternal closure using rigid fixation techniques in human cadavers. Ann Thorac Surg. 1998;65:1660–5.CrossRef
16.
go back to reference Gloyer MA, Frei HC, Hotz TK, Käch KP. Osteosynthesis of traumatic manubriosternal dislocations and sternal fractures with a 3.5/.40 mm fixed-angle plate (LCP). Arch Orthop Trauma Surg. 2011;131:1261–6.CrossRef Gloyer MA, Frei HC, Hotz TK, Käch KP. Osteosynthesis of traumatic manubriosternal dislocations and sternal fractures with a 3.5/.40 mm fixed-angle plate (LCP). Arch Orthop Trauma Surg. 2011;131:1261–6.CrossRef
17.
go back to reference Zhao Y, Yang Y, Gao Z, Wu W, He W, Zhao T. Treatment of traumatic sternal fractures with titanium plate internal fixation: a retrospective study. J Cardiothorac Surg. 2017;12:1–5.CrossRef Zhao Y, Yang Y, Gao Z, Wu W, He W, Zhao T. Treatment of traumatic sternal fractures with titanium plate internal fixation: a retrospective study. J Cardiothorac Surg. 2017;12:1–5.CrossRef
19.
go back to reference Hoschtitzky JA, Khalid R, Au J, Sampath S. Open reduction and internal fixation of a non-united transverse sternal fracture. Inj Extra. 2005;36:214–6.CrossRef Hoschtitzky JA, Khalid R, Au J, Sampath S. Open reduction and internal fixation of a non-united transverse sternal fracture. Inj Extra. 2005;36:214–6.CrossRef
20.
go back to reference Severson EP, Thompson CA, Resig SG, Swiontkowski MF. Transverse sternal nonunion, repair and revision: a case report and review of the literature. J Trauma Inj Infect Crit Care. 2009;66:1485–8.CrossRef Severson EP, Thompson CA, Resig SG, Swiontkowski MF. Transverse sternal nonunion, repair and revision: a case report and review of the literature. J Trauma Inj Infect Crit Care. 2009;66:1485–8.CrossRef
21.
go back to reference Akiba T, Marushima H, Nogi H, Kamiya N, Kinoshita S, Takeyama H, et al. Chest wall reconstruction using Gore-Tex® dual mesh. Ann Thorac Cardiovasc Surg. 2012;18:166–9.CrossRef Akiba T, Marushima H, Nogi H, Kamiya N, Kinoshita S, Takeyama H, et al. Chest wall reconstruction using Gore-Tex® dual mesh. Ann Thorac Cardiovasc Surg. 2012;18:166–9.CrossRef
22.
go back to reference Hamad AM, Marulli G, Bulf R, Rea F. Titanium plates support for chest wall reconstruction with Gore-Tex® dual mesh after sternochondral resection. Eur J Cardio Thorac Surg. 2009;36:779–80.CrossRef Hamad AM, Marulli G, Bulf R, Rea F. Titanium plates support for chest wall reconstruction with Gore-Tex® dual mesh after sternochondral resection. Eur J Cardio Thorac Surg. 2009;36:779–80.CrossRef
23.
go back to reference Nagayasu T, Yamasaki N, Tagawa T, Tsuchiya T, Miyazaki T, Nanashima A, et al. Long-term results of chest wall reconstruction with DualMesh. Interact Cardiovasc Thorac Surg. 2010;11:581–4.CrossRef Nagayasu T, Yamasaki N, Tagawa T, Tsuchiya T, Miyazaki T, Nanashima A, et al. Long-term results of chest wall reconstruction with DualMesh. Interact Cardiovasc Thorac Surg. 2010;11:581–4.CrossRef
24.
go back to reference Berthet JP, Wihlm JM, Canaud L, Joyeux F, Cosma C, Hireche K, et al. The combination of polytetrafluoroethylene mesh and titanium rib implants: an innovative process for reconstructing large full thickness chest wall defects. Eur J Cardio-Thorac Surg. 2012;42:444–53.CrossRef Berthet JP, Wihlm JM, Canaud L, Joyeux F, Cosma C, Hireche K, et al. The combination of polytetrafluoroethylene mesh and titanium rib implants: an innovative process for reconstructing large full thickness chest wall defects. Eur J Cardio-Thorac Surg. 2012;42:444–53.CrossRef
Metadata
Title
Postoperative transverse sternal nonunion with a chest wall defect managed by a tibial locking plate and a Gore-Tex dual mesh membrane: a case report
Authors
Tomaz Malovrh
Tomaz Stupnik
Boris Podobnik
Jurij Matija Kalisnik
Publication date
01-12-2021
Publisher
BioMed Central
Published in
Journal of Cardiothoracic Surgery / Issue 1/2021
Electronic ISSN: 1749-8090
DOI
https://doi.org/10.1186/s13019-021-01730-5

Other articles of this Issue 1/2021

Journal of Cardiothoracic Surgery 1/2021 Go to the issue