Abstract

Purpose

To assess the outcomes of Descemet stripping automated endothelial keratoplasty (DSAEK) via a sclerocorneal frown incision.

Study design

Retrospective comparative study.

Methods

The outcomes of Descement stripping endothelial keratoplasty (DSAEK) were retrospectively compared between 36 patients (36 eyes) who underwent surgery via a 3.8-mm frown incision (frown incision group) and 20 patients (20 eyes) who underwent surgery via a 4.6-mm straight incision (straight incision group). In all patients, an NS Endo-Inserter was used as the graft inserter and the incision for a frown incision was via the superior sclerocorneal site and for the straight incision via the temporal cornea. DSAEK was performed by the standard technique, except for the incision. At 1 year after surgery, the two groups were compared with respect to the visual acuity, decrease of corneal endothelial cell density, the severity of corneal astigmatism (diopters), the number of sutures for wound closure, and intraoperative/postoperative complications.

Results

There was no significant difference between the two groups in terms of postoperative visual acuity, corneal astigmatism, and intraoperative/postoperative complications one year after surgery. On the other hand, the number of sutures required for wound closure was 1.13 ± 0.42 in the frown incision group, whereas in the straight incision group, it was 3.20 ± 0.40, showing a significant difference (P<0.001). In addition, there was no decreased corneal endothelial cell density associated with the reduction in incision width.

Conclusions

A sclerocorneal frown incision is useful for performing DSAEK with an NS Endo-Inserter as it does not affect endothelial cell loss despite its short incision width.
Literature
1.
go back to reference Terry MA, Saad HA, Shamie N, Chen ES, Phillips PM, Friend DJ, et al. Endothelial keratoplasty: the influence of insertion techniques and incision size on donor endothelial survival. Cornea. 2009;28:24–31.CrossRefPubMed Terry MA, Saad HA, Shamie N, Chen ES, Phillips PM, Friend DJ, et al. Endothelial keratoplasty: the influence of insertion techniques and incision size on donor endothelial survival. Cornea. 2009;28:24–31.CrossRefPubMed
2.
go back to reference Price MO, Bidros M, Gorovoy M, Price FW Jr, Benetz BA, Menegay HJ, et al. Effect of incision width on graft survival and endothelial cell loss after descemet stripping automated endothelial keratoplasty. Cornea. 2010;29:523–7.CrossRefPubMedPubMedCentral Price MO, Bidros M, Gorovoy M, Price FW Jr, Benetz BA, Menegay HJ, et al. Effect of incision width on graft survival and endothelial cell loss after descemet stripping automated endothelial keratoplasty. Cornea. 2010;29:523–7.CrossRefPubMedPubMedCentral
3.
go back to reference Singer JA. Frown incision for minimizing induced astigmatism after small incision cataract surgery with rigid optic intraocular lens implantation. J Cataract Refract Surg. 1991;17. Singer JA. Frown incision for minimizing induced astigmatism after small incision cataract surgery with rigid optic intraocular lens implantation. J Cataract Refract Surg. 1991;17.
4.
go back to reference Soma T, Koh S, Maeda N, Mitomo K, Quantock AJ, Nishida K, et al. New graft insertion device for descemet stripping automated endothelial Keratoplasty. Cornea. 2017;36:1432–6.CrossRefPubMed Soma T, Koh S, Maeda N, Mitomo K, Quantock AJ, Nishida K, et al. New graft insertion device for descemet stripping automated endothelial Keratoplasty. Cornea. 2017;36:1432–6.CrossRefPubMed
5.
go back to reference Nakatani S, Murakami A. Descemet stripping automated endothelial keratoplasty for bullous keratopathy after anterior-posterior radial keratotomy. Cornea. 2013;32:1179–82.CrossRefPubMed Nakatani S, Murakami A. Descemet stripping automated endothelial keratoplasty for bullous keratopathy after anterior-posterior radial keratotomy. Cornea. 2013;32:1179–82.CrossRefPubMed
6.
go back to reference Nakatani S, Murakami A. Three-year outcome of Descemet stripping automated endothelial keratoplasty for bullous keratopathy after argon laser iridotomy. Cornea. 2014;33:780–4.CrossRefPubMed Nakatani S, Murakami A. Three-year outcome of Descemet stripping automated endothelial keratoplasty for bullous keratopathy after argon laser iridotomy. Cornea. 2014;33:780–4.CrossRefPubMed
7.
go back to reference Nakatani S, Murakami A. Descemet stripping automated endothelial keratoplasty using corneas from elderly donors. Graefes Arch Clin Exp Ophthalmol. 2016;254:1135–40.CrossRefPubMed Nakatani S, Murakami A. Descemet stripping automated endothelial keratoplasty using corneas from elderly donors. Graefes Arch Clin Exp Ophthalmol. 2016;254:1135–40.CrossRefPubMed
8.
go back to reference Macaluso C. Closed-chamber pulling-injection system for donor graft insertion in endothelial keratoplasty. J Cataract Refract Surg. 2008;34:353–6.CrossRefPubMed Macaluso C. Closed-chamber pulling-injection system for donor graft insertion in endothelial keratoplasty. J Cataract Refract Surg. 2008;34:353–6.CrossRefPubMed
9.
go back to reference Khor WB, Mehta JS, Tan DT. Descemet stripping automated endothelial keratoplasty with a graft insertion device: surgical technique and early clinical results. Am J Ophthalmol. 2011;151:223–32.CrossRefPubMed Khor WB, Mehta JS, Tan DT. Descemet stripping automated endothelial keratoplasty with a graft insertion device: surgical technique and early clinical results. Am J Ophthalmol. 2011;151:223–32.CrossRefPubMed
10.
go back to reference Ruzza A, Parekh M, Ferrari S, Salvalaio G, Nahum Y, Bovone C, et al. Preloaded donor corneal lenticules in a new validated 3D printed smart storage glide for Descemet stripping automated endothelial keratoplasty. Br J Ophthalmol. 2015;99:1388–95.CrossRefPubMed Ruzza A, Parekh M, Ferrari S, Salvalaio G, Nahum Y, Bovone C, et al. Preloaded donor corneal lenticules in a new validated 3D printed smart storage glide for Descemet stripping automated endothelial keratoplasty. Br J Ophthalmol. 2015;99:1388–95.CrossRefPubMed
11.
go back to reference Khan SN, Shiakolas PS, Mootha VV. Descemet’s Stripping Automated Endothelial Keratoplasty Tissue Insertion Devices. J Ophthalmic Vis Res. 2015;10:461–8.CrossRefPubMedPubMedCentral Khan SN, Shiakolas PS, Mootha VV. Descemet’s Stripping Automated Endothelial Keratoplasty Tissue Insertion Devices. J Ophthalmic Vis Res. 2015;10:461–8.CrossRefPubMedPubMedCentral
12.
go back to reference Gangwani V, Obi A, Hollick EJ. A prospective study comparing EndoGlide and Busin glide insertion techniques in descemet stripping endothelial keratoplasty. Am J Ophthalmol. 2012;153:38–43.CrossRefPubMed Gangwani V, Obi A, Hollick EJ. A prospective study comparing EndoGlide and Busin glide insertion techniques in descemet stripping endothelial keratoplasty. Am J Ophthalmol. 2012;153:38–43.CrossRefPubMed
13.
go back to reference Foster JB, Swan KR, Vasan RA, Greven MA, Walter KA. Small-incision Descemet stripping automated endothelial keratoplasty: a comparison of small-incision tissue injector and forceps techniques. Cornea. 2012;31:42–7.CrossRefPubMed Foster JB, Swan KR, Vasan RA, Greven MA, Walter KA. Small-incision Descemet stripping automated endothelial keratoplasty: a comparison of small-incision tissue injector and forceps techniques. Cornea. 2012;31:42–7.CrossRefPubMed
14.
go back to reference Kobayashi A, Yokogawa H, Sugiyama K. Clinical results of the Neusidl Corneal Inserter(R), a new donor inserter for Descemet’s stripping automated endothelial keratoplasty, for small Asian eyes. Ophthalmic Surg Lasers Imaging. 2012;43:311–8.CrossRefPubMed Kobayashi A, Yokogawa H, Sugiyama K. Clinical results of the Neusidl Corneal Inserter(R), a new donor inserter for Descemet’s stripping automated endothelial keratoplasty, for small Asian eyes. Ophthalmic Surg Lasers Imaging. 2012;43:311–8.CrossRefPubMed
15.
go back to reference Elbaz U, Yeung SN, Lichtinger A, Zauberman NA, Goldich Y, Ziai S, et al. EndoGlide versus EndoSerter for the insertion of donor graft in descemet stripping automated endothelial keratoplasty. Am J Ophthalmol. 2014;158:257–62.CrossRefPubMed Elbaz U, Yeung SN, Lichtinger A, Zauberman NA, Goldich Y, Ziai S, et al. EndoGlide versus EndoSerter for the insertion of donor graft in descemet stripping automated endothelial keratoplasty. Am J Ophthalmol. 2014;158:257–62.CrossRefPubMed
16.
go back to reference Soma T, Koh S, Oie Y, Maruyama K, Tsujikawa M, Kawasaki S, et al. Clinical evaluation of a newly developed graft inserter (NS Endo-Inserter) for Descemet stripping automated endothelial keratoplasty. Clin Ophthalmol. 2018;13:43–8.CrossRefPubMedPubMedCentral Soma T, Koh S, Oie Y, Maruyama K, Tsujikawa M, Kawasaki S, et al. Clinical evaluation of a newly developed graft inserter (NS Endo-Inserter) for Descemet stripping automated endothelial keratoplasty. Clin Ophthalmol. 2018;13:43–8.CrossRefPubMedPubMedCentral
17.
go back to reference Gelender H. Management of corneal astigmatism after cataract surgery. Refract Corneal Surg. 1991;7:99–102.CrossRefPubMed Gelender H. Management of corneal astigmatism after cataract surgery. Refract Corneal Surg. 1991;7:99–102.CrossRefPubMed
18.
go back to reference Simşek S, Yaşar T, Demirok A, Clinal A, Yilmaz OF. Effect of superior and temporal clear corneal incisions on astigmatism after sutureless phacoemulsification. J Cataract Refract Surg. 1998;24:515–8.CrossRefPubMed Simşek S, Yaşar T, Demirok A, Clinal A, Yilmaz OF. Effect of superior and temporal clear corneal incisions on astigmatism after sutureless phacoemulsification. J Cataract Refract Surg. 1998;24:515–8.CrossRefPubMed
19.
go back to reference Barequet IS, Yu E, Vitale S, Cassard S, Azar DT, Stark WJ. Astigmatism outcomes of horizontal temporal versus nasal clear corneal incision cataract surgery. J Cataract Refract Surg. 2004;30:418–23.CrossRefPubMed Barequet IS, Yu E, Vitale S, Cassard S, Azar DT, Stark WJ. Astigmatism outcomes of horizontal temporal versus nasal clear corneal incision cataract surgery. J Cataract Refract Surg. 2004;30:418–23.CrossRefPubMed
20.
go back to reference Tejedor J, Pérez-Rodríguez JA. Astigmatic change induced by 2.8-mm corneal incisions for cataract surgery. Invest Ophthalmol Vis Sci. 2009;50:989–94.CrossRefPubMed Tejedor J, Pérez-Rodríguez JA. Astigmatic change induced by 2.8-mm corneal incisions for cataract surgery. Invest Ophthalmol Vis Sci. 2009;50:989–94.CrossRefPubMed
21.
go back to reference Fuest M, Ang M, Htoon HM, Tan D, Mehta JS. Long-term visual outcomes comparing descemet stripping automated endothelial keratoplasty and penetrating keratoplasty. Am J Ophthalmol. 2017;182:62–71.CrossRefPubMed Fuest M, Ang M, Htoon HM, Tan D, Mehta JS. Long-term visual outcomes comparing descemet stripping automated endothelial keratoplasty and penetrating keratoplasty. Am J Ophthalmol. 2017;182:62–71.CrossRefPubMed
22.
go back to reference Kim SE, Lim SA, Byun YS, Joo CK. Comparison of long-term clinical outcomes between descemet’s stripping automated endothelial keratoplasty and penetrating keratoplasty in patients with bullous keratopathy. Korean J Ophthalmol. 2016;30:443–50.CrossRefPubMedPubMedCentral Kim SE, Lim SA, Byun YS, Joo CK. Comparison of long-term clinical outcomes between descemet’s stripping automated endothelial keratoplasty and penetrating keratoplasty in patients with bullous keratopathy. Korean J Ophthalmol. 2016;30:443–50.CrossRefPubMedPubMedCentral
23.
go back to reference Droutsas K, Lazaridis A, Papaconstantinou D, Brouzas D, Moschos MM. Visual outcomes after descemet membrane endothelial keratoplasty versus descemet stripping automated endothelial keratoplasty-comparison of specific matched pairs. Cornea. 2016;35:765–71.CrossRefPubMed Droutsas K, Lazaridis A, Papaconstantinou D, Brouzas D, Moschos MM. Visual outcomes after descemet membrane endothelial keratoplasty versus descemet stripping automated endothelial keratoplasty-comparison of specific matched pairs. Cornea. 2016;35:765–71.CrossRefPubMed
24.
go back to reference Jauhari N, Chopra D, Chaurasia RK, Agarwal A. Comparison of surgically induced astigmatism in various incisions in manual small incision cataract surgery. Int J Ophthalmol. 2014;7:1001–4.PubMedPubMedCentral Jauhari N, Chopra D, Chaurasia RK, Agarwal A. Comparison of surgically induced astigmatism in various incisions in manual small incision cataract surgery. Int J Ophthalmol. 2014;7:1001–4.PubMedPubMedCentral
25.
go back to reference Rathi M, Dabas R, Verma R, Rustagi IM, Mathur S, Dhania S. Comparison of surgically induced astigmatism in chevron, straight, and frown incisions in manual small-incision cataract surgery. Indian J Ophthalmol. 2022;70:3865–8.CrossRefPubMedPubMedCentral Rathi M, Dabas R, Verma R, Rustagi IM, Mathur S, Dhania S. Comparison of surgically induced astigmatism in chevron, straight, and frown incisions in manual small-incision cataract surgery. Indian J Ophthalmol. 2022;70:3865–8.CrossRefPubMedPubMedCentral
26.
go back to reference Tan D, Ang M, Arundhati A, Khor WB. Development of selective lamellar keratoplasty within an Asian corneal transplant program: the Singapore corneal transplant study (an American Ophthalmological Society Thesis. Trans Am Ophthalmol. 2015;113:T10-1–23. Tan D, Ang M, Arundhati A, Khor WB. Development of selective lamellar keratoplasty within an Asian corneal transplant program: the Singapore corneal transplant study (an American Ophthalmological Society Thesis. Trans Am Ophthalmol. 2015;113:T10-1–23.
Metadata
Title
Descemet stripping automated endothelial keratoplasty via a frown incision
Authors
Satoru Nakatani
Masahiro Yamaguchi
Satoshi Iwamoto
Publication date
02-01-2024
Publisher
Springer Japan
Published in
Japanese Journal of Ophthalmology / Issue 1/2024
Print ISSN: 0021-5155
Electronic ISSN: 1613-2246
DOI
https://doi.org/10.1007/s10384-023-01038-y

Other articles of this Issue 1/2024

Japanese Journal of Ophthalmology 1/2024 Go to the issue