Skip to main content
Top
Published in: BMC Ophthalmology 1/2019

Open Access 01-12-2019 | Incision | Research article

Comparison of anterior segment changes after femtosecond laser LASIK and SMILE using a dual rotating Scheimpflug analyzer

Authors: Bu Ki Kim, Su Joung Mun, Young Hoon Yang, Ji Sun Kim, Jun Hyung Moon, Young Taek Chung

Published in: BMC Ophthalmology | Issue 1/2019

Login to get access

Abstract

Background

To compare the changes in the anterior segment after femtosecond laser in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE) using a dual rotating Scheimpflug (DRS) analyzer (Galilei®; Ziemer Ophthalmology, Port, Switzerland).

Methods

A total of 218 eyes of 109 patients who underwent FS-LASIK or SMILE for myopic correction were retrospectively studied. Ninety-eight eyes of 49 patients who underwent FS-LASIK were compared to 120 eyes of 60 patients treated with SMILE. A DRS analyzer was used for preoperative and 6-month postoperative anterior segment analyses. Measured variables included the central corneal thickness (CCT), anterior chamber depth (ACD), anterior and posterior keratometry (K), anterior and posterior best-fit sphere radius, and maximum posterior elevation (MPE).

Results

After the procedure, the amount of CCT decrease was higher in the SMILE group than in the FS-LASIK group, but it was not statistically significant. The MPE was significantly increased after both procedures (p < 0.001 and p = 0.001 in the FS-LASIK and SMILE groups, respectively), with the amount of elevation being higher after FS-LASIK than after SMILE even though it was not statistically significant. And there was a significant change in the steep and average posterior K in the FS-LASIK group (p = 0.006 and 0.001, respectively), but not in the SMILE group.

Conclusions

Regarding changes in the MPE and posterior K, changes in the posterior corneal surface were greater after FS-LASIK than after SMILE.

Trial registration

The trial registration number: KCT0003628. Date of registration: 15 March 2019.
Literature
1.
go back to reference Vryghem JC, Devogelaere T, Stodulka P. Efficacy, safety, and flap dimensions of a new femtosecond laser for laser in situ keratomileusis. J Cataract Refract Surg. 2010;36:442–8.CrossRef Vryghem JC, Devogelaere T, Stodulka P. Efficacy, safety, and flap dimensions of a new femtosecond laser for laser in situ keratomileusis. J Cataract Refract Surg. 2010;36:442–8.CrossRef
2.
go back to reference dos Santos AM, Torricelli AA, Marino GK, Garcia R, Netto MV, Bechara SJ, Wilson SE. Femtosecond laser-assisted LASIK flap complications. J Refract Surg. 2016;32:52–9.CrossRef dos Santos AM, Torricelli AA, Marino GK, Garcia R, Netto MV, Bechara SJ, Wilson SE. Femtosecond laser-assisted LASIK flap complications. J Refract Surg. 2016;32:52–9.CrossRef
3.
go back to reference Sekundo W, Kunert KS, Blum M. Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study. Br J Ophthalmol. 2011;95:335–9.CrossRef Sekundo W, Kunert KS, Blum M. Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study. Br J Ophthalmol. 2011;95:335–9.CrossRef
4.
go back to reference Vestergaard A, Ivarsen A, Asp S, Hjortdal JØ. Femtosecond (FS) laser vision correction procedure for moderate to high myopia: a prospective study of ReLEx(®) flex and comparison with a retrospective study of FS-laser in situ keratomileusis. Acta Ophthalmol. 2013;91:355–62.CrossRef Vestergaard A, Ivarsen A, Asp S, Hjortdal JØ. Femtosecond (FS) laser vision correction procedure for moderate to high myopia: a prospective study of ReLEx(®) flex and comparison with a retrospective study of FS-laser in situ keratomileusis. Acta Ophthalmol. 2013;91:355–62.CrossRef
5.
go back to reference Vestergaard A, Ivarsen AR, Asp S, Hjortdal JØ. Small-incision lenticule extraction for moderate to high myopia: predictability, safety, and patient satisfaction. J Cataract Refract Surg. 2012;38:2003–10.CrossRef Vestergaard A, Ivarsen AR, Asp S, Hjortdal JØ. Small-incision lenticule extraction for moderate to high myopia: predictability, safety, and patient satisfaction. J Cataract Refract Surg. 2012;38:2003–10.CrossRef
6.
go back to reference Petsche SJ, Chernyak D, Martiz J, Levenston ME, Pinsky PM. Depth-dependent transverse shear properties of the human corneal stroma. Invest Ophthalmol Vis Sci. 2012;53:873–80.CrossRef Petsche SJ, Chernyak D, Martiz J, Levenston ME, Pinsky PM. Depth-dependent transverse shear properties of the human corneal stroma. Invest Ophthalmol Vis Sci. 2012;53:873–80.CrossRef
7.
go back to reference Dawson DG, Grossniklaus HE, McCarey BE, Edelhauser HF. Biomechanical and wound healing characteristics of corneas after excimer laser keratorefractive surgery: is there a difference between advanced surface ablation and sub-Bowman’s keratomileusis. J Refract Surg. 2008;24:S90–6.CrossRef Dawson DG, Grossniklaus HE, McCarey BE, Edelhauser HF. Biomechanical and wound healing characteristics of corneas after excimer laser keratorefractive surgery: is there a difference between advanced surface ablation and sub-Bowman’s keratomileusis. J Refract Surg. 2008;24:S90–6.CrossRef
8.
go back to reference Randleman JB, Woodward M, Lynn MJ, Stulting RD. Risk assessment for ectasia after corneal refractive surgery. Ophthalmology. 2008;115:37–50.CrossRef Randleman JB, Woodward M, Lynn MJ, Stulting RD. Risk assessment for ectasia after corneal refractive surgery. Ophthalmology. 2008;115:37–50.CrossRef
9.
go back to reference Menassa N, Kaufmann C, Goggin M, Job OM, Bachmann LM, Thiel MA. Comparison and reproducibility of corneal thickness and curvature readings obtained by the Galilei and the Orbscan II analysis systems. J Cataract Refract Surg. 2008;34:1742–7.CrossRef Menassa N, Kaufmann C, Goggin M, Job OM, Bachmann LM, Thiel MA. Comparison and reproducibility of corneal thickness and curvature readings obtained by the Galilei and the Orbscan II analysis systems. J Cataract Refract Surg. 2008;34:1742–7.CrossRef
10.
go back to reference Salouti R, Nowroozzadeh MH, Zamani M, Fard AH, Niknam S. Comparison of anterior and posterior elevation map measurements between 2 Scheimpflug imaging systems. J Cataract Refract Surg. 2009;35:856–62.CrossRef Salouti R, Nowroozzadeh MH, Zamani M, Fard AH, Niknam S. Comparison of anterior and posterior elevation map measurements between 2 Scheimpflug imaging systems. J Cataract Refract Surg. 2009;35:856–62.CrossRef
11.
go back to reference Kim EJ, de Oca I M, Wang L, Weikert MP, Koch DD, Khandelwal SS. Repeatability of posterior and total corneal curvature measurements with a dual Scheimpflug–Placido tomographer. J Cataract Refract Surg. 2015;41:2731–8.CrossRef Kim EJ, de Oca I M, Wang L, Weikert MP, Koch DD, Khandelwal SS. Repeatability of posterior and total corneal curvature measurements with a dual Scheimpflug–Placido tomographer. J Cataract Refract Surg. 2015;41:2731–8.CrossRef
12.
go back to reference Park SH, Choi SK, Lee D, Jun EJ, Kim JH. Corneal thickness measurement using Orbscan, Pentacam, Galilei, and ultrasound in normal and post-femtosecond laser in situ keratomileusis eyes. Cornea. 2012;31:978–82.CrossRef Park SH, Choi SK, Lee D, Jun EJ, Kim JH. Corneal thickness measurement using Orbscan, Pentacam, Galilei, and ultrasound in normal and post-femtosecond laser in situ keratomileusis eyes. Cornea. 2012;31:978–82.CrossRef
13.
go back to reference Kim BK, Mun SJ, Lee DG, Choi HT, Chung YT. Chung’s swing technique: a new technique for small-incision lenticule extraction. BMC Ophthalmol. 2016;16:154.CrossRef Kim BK, Mun SJ, Lee DG, Choi HT, Chung YT. Chung’s swing technique: a new technique for small-incision lenticule extraction. BMC Ophthalmol. 2016;16:154.CrossRef
14.
go back to reference Stacey AW, Pouly S, Czyz CN. An analysis of the use of multiple comparison corrections in ophthalmology research. Invest Ophthalmol Vis Sci. 2012;53:1830–4.CrossRef Stacey AW, Pouly S, Czyz CN. An analysis of the use of multiple comparison corrections in ophthalmology research. Invest Ophthalmol Vis Sci. 2012;53:1830–4.CrossRef
16.
go back to reference Wang D, Liu M, Chen Y, Zhang X, Xu Y, Wang J, To CH, Liu Q. Differences in the corneal biomechanical changes after SMILE and LASIK. J Refract Surg. 2014;30:702–7.CrossRef Wang D, Liu M, Chen Y, Zhang X, Xu Y, Wang J, To CH, Liu Q. Differences in the corneal biomechanical changes after SMILE and LASIK. J Refract Surg. 2014;30:702–7.CrossRef
17.
go back to reference Luft N, Priglinger SG, Ring MH, Mayer WJ, Mursch-Edlmayr AS, Kreutzer TC, Bolz M, Dirisamer M. Stromal remodeling and lenticule thickness accuracy in small-incision lenticule extraction: one-year results. J Cataract Refract Surg. 2017;43:812–8.CrossRef Luft N, Priglinger SG, Ring MH, Mayer WJ, Mursch-Edlmayr AS, Kreutzer TC, Bolz M, Dirisamer M. Stromal remodeling and lenticule thickness accuracy in small-incision lenticule extraction: one-year results. J Cataract Refract Surg. 2017;43:812–8.CrossRef
18.
go back to reference Dupps WJ Jr. Biomechanical modeling of corneal ectasia. J Refract Surg. 2005;21:186–90.PubMed Dupps WJ Jr. Biomechanical modeling of corneal ectasia. J Refract Surg. 2005;21:186–90.PubMed
19.
go back to reference Twa MD, Nichols JJ, Joslin CE, Kollbaum PS, Edrington TB, Bullimore MA, Mitchell GL, Cruickshanks KJ, Schanzlin DJ. Characteristics of corneal ectasia after LASIK for myopia. Cornea. 2004;23:447–57.CrossRef Twa MD, Nichols JJ, Joslin CE, Kollbaum PS, Edrington TB, Bullimore MA, Mitchell GL, Cruickshanks KJ, Schanzlin DJ. Characteristics of corneal ectasia after LASIK for myopia. Cornea. 2004;23:447–57.CrossRef
20.
go back to reference Baek T, Lee K, Kagaya F, Tomidokoro A, Amano S, Oshika T. Factors affecting the forward shift of posterior corneal surface after laser in situ keratomileusis. Ophthalmology. 2001;108:317–20.CrossRef Baek T, Lee K, Kagaya F, Tomidokoro A, Amano S, Oshika T. Factors affecting the forward shift of posterior corneal surface after laser in situ keratomileusis. Ophthalmology. 2001;108:317–20.CrossRef
21.
go back to reference Wang B, Zhang Z, Naidu RK, Chu R, Dai J, Qu X, Yu Z, Zhou H. Comparison of the change in posterior corneal elevation and corneal biomechanical parameters after small incision lenticule extraction and femtosecond laser-assisted LASIK for high myopia correction. Cont Lens Anterior Eye. 2016;39:191–6.CrossRef Wang B, Zhang Z, Naidu RK, Chu R, Dai J, Qu X, Yu Z, Zhou H. Comparison of the change in posterior corneal elevation and corneal biomechanical parameters after small incision lenticule extraction and femtosecond laser-assisted LASIK for high myopia correction. Cont Lens Anterior Eye. 2016;39:191–6.CrossRef
22.
go back to reference Seitz B, Torres F, Langenbucher A, Behrens A, Suárez E. Posterior corneal curvature changes after myopic laser in situ keratomileusis. Ophthalmology. 2001;108:666–72.CrossRef Seitz B, Torres F, Langenbucher A, Behrens A, Suárez E. Posterior corneal curvature changes after myopic laser in situ keratomileusis. Ophthalmology. 2001;108:666–72.CrossRef
23.
go back to reference Khairat YM, Mohamed YH, Moftah IA, Fouad NN. Evaluation of corneal changes after myopic LASIK using the Pentacam®. Clin Ophthalmol. 2013;7:1771–6.PubMedPubMedCentral Khairat YM, Mohamed YH, Moftah IA, Fouad NN. Evaluation of corneal changes after myopic LASIK using the Pentacam®. Clin Ophthalmol. 2013;7:1771–6.PubMedPubMedCentral
24.
go back to reference Ganesh S, Patel U, Brar S. Posterior corneal curvature changes following refractive small incision lenticule extraction. Clin Ophthalmol. 2015;9:1359–64.CrossRef Ganesh S, Patel U, Brar S. Posterior corneal curvature changes following refractive small incision lenticule extraction. Clin Ophthalmol. 2015;9:1359–64.CrossRef
25.
go back to reference Cairns G, Ormonde SE, Gray T, Hadden OB, Morris T, Ring P, McGhee CN. Assessing the accuracy of Orbscan II post-LASIK: apparent keratectasia is paradoxically associated with anterior chamber depth reduction in successful procedures. Clin Exp Ophthalmol. 2005;33:147–52.CrossRef Cairns G, Ormonde SE, Gray T, Hadden OB, Morris T, Ring P, McGhee CN. Assessing the accuracy of Orbscan II post-LASIK: apparent keratectasia is paradoxically associated with anterior chamber depth reduction in successful procedures. Clin Exp Ophthalmol. 2005;33:147–52.CrossRef
26.
go back to reference Nishimura R, Negishi K, Dogru M, Saiki M, Arai H, Toda I, Yamaguchi T, Tsubota K. Effect of age on changes in anterior chamber depth and volume after laser in situ keratomileusis. J Cataract Refract Surg. 2009;35:1868–72.CrossRef Nishimura R, Negishi K, Dogru M, Saiki M, Arai H, Toda I, Yamaguchi T, Tsubota K. Effect of age on changes in anterior chamber depth and volume after laser in situ keratomileusis. J Cataract Refract Surg. 2009;35:1868–72.CrossRef
27.
go back to reference Wang L, Guo HK, Zeng J, Jin HY. Analysis of changes in crystalline lens thickness and its refractive power after laser in situ keratomileusis. Int J Ophthalmol. 2012;5:97–101.PubMedPubMedCentral Wang L, Guo HK, Zeng J, Jin HY. Analysis of changes in crystalline lens thickness and its refractive power after laser in situ keratomileusis. Int J Ophthalmol. 2012;5:97–101.PubMedPubMedCentral
28.
go back to reference Rosa N, Lanza M, Capasso L, Lucci M, Polito B, Romano A. Anterior chamber depth measurement before and after photorefractive keratectomy: comparison between IOL master and Orbscan II. Ophthalmology. 2006;113:962–9.CrossRef Rosa N, Lanza M, Capasso L, Lucci M, Polito B, Romano A. Anterior chamber depth measurement before and after photorefractive keratectomy: comparison between IOL master and Orbscan II. Ophthalmology. 2006;113:962–9.CrossRef
30.
go back to reference Zhang L, Wang Y. The shape of posterior corneal surface in normal, post-LASIK, and post-epi-LASIK eyes. Invest Ophthalmol Vis Sci. 2010;51:3468–75.CrossRef Zhang L, Wang Y. The shape of posterior corneal surface in normal, post-LASIK, and post-epi-LASIK eyes. Invest Ophthalmol Vis Sci. 2010;51:3468–75.CrossRef
Metadata
Title
Comparison of anterior segment changes after femtosecond laser LASIK and SMILE using a dual rotating Scheimpflug analyzer
Authors
Bu Ki Kim
Su Joung Mun
Young Hoon Yang
Ji Sun Kim
Jun Hyung Moon
Young Taek Chung
Publication date
01-12-2019
Publisher
BioMed Central
Published in
BMC Ophthalmology / Issue 1/2019
Electronic ISSN: 1471-2415
DOI
https://doi.org/10.1186/s12886-019-1257-0

Other articles of this Issue 1/2019