Skip to main content
Top
Published in: BMC Ophthalmology 1/2019

Open Access 01-12-2019 | Incision | Research article

Clinical observation of a novel technique: transscleral suture fixation of a foldable 3-looped haptics one-piece posterior chamber intraocular lens implantation through scleral pockets with intact conjunctiva

Authors: Shuang Ni, Wei Wang, Xiang Chen, Xingdi Wu, Suhong He, Yajuan Ma, Wen Xu

Published in: BMC Ophthalmology | Issue 1/2019

Login to get access

Abstract

Background

To present the follow-up outcomes of a modified technique of transscleral suture fixation of posterior chamber intraocular lens (PCIOL) in eyes with inadequate capsule support.

Methods

A retrospective chart review of 21 patients underwent transscleral suture fixation of a foldable 3-looped haptics one-piece PCIOL implantation through scleral pockets was conducted. Preoperative data and follow-up data for at least 3 months were collected for all patients.

Results

The mean operative duration was 36.62 ± 10.70 min. The mean pre- and post-operative LogMAR uncorrected distance visual acuity was (1.25 ± 0.50 vs. 0.41 ± 0.22, P < 0.01). The mean pre- and post-operative LogMAR best corrected visual acuity was (0.48 ± 0.25 vs. 0.33 ± 0.24, P < 0.01). The mean proportion of postoperative endothelial cell loss was 11.46 ± 4.78%. The mean postoperative anterior chamber depth was 3.05 ± 0.44 mm. The mean postoperative IOL tilt degree was 2.81 ± 1.41°, and the mean postoperative IOL decentration degree was 0.31 ± 0.13 mm. Four patients with transient corneal edema (19.0%) and three patients with transiently elevated IOP (14.3%) were observed after operation, and such complications were resolved within 1 week. No severe complications were observed.

Conclusions

The modified technique was a feasible method of PCIOL implantation.
Appendix
Available only for authorised users
Literature
1.
go back to reference Mizuno Y, Sugimoto Y. A comparative study of transscleral suture-fixated and scleral-fixated intraocular lens implantation. Int Ophthalmol. 2018;1:1–7. Mizuno Y, Sugimoto Y. A comparative study of transscleral suture-fixated and scleral-fixated intraocular lens implantation. Int Ophthalmol. 2018;1:1–7.
2.
go back to reference Price MO, Price FW, Jr., Werner L, Berlie C, Mamalis N: Late dislocation of scleral-sutured posterior chamber intraocular lenses. J Cataract Refract Surg 2005, 31(7):1320–1326.CrossRef Price MO, Price FW, Jr., Werner L, Berlie C, Mamalis N: Late dislocation of scleral-sutured posterior chamber intraocular lenses. J Cataract Refract Surg 2005, 31(7):1320–1326.CrossRef
3.
go back to reference Buckley EG. Safety of transscleral-sutured intraocular lenses in children. J AAPOS. 2008;12(5):431–9.CrossRef Buckley EG. Safety of transscleral-sutured intraocular lenses in children. J AAPOS. 2008;12(5):431–9.CrossRef
4.
go back to reference Long C, Wei Y, Yuan Z, Zhang Z, Lin X, Liu B. Modified technique for transscleral fixation of posterior chamber intraocular lenses. BMC Ophthalmol. 2015;15:127.CrossRef Long C, Wei Y, Yuan Z, Zhang Z, Lin X, Liu B. Modified technique for transscleral fixation of posterior chamber intraocular lenses. BMC Ophthalmol. 2015;15:127.CrossRef
5.
go back to reference Haszcz D, Nowomiejska K, Oleszczuk A, Forlini C, Forlini M, Moneta-Wielgos J, Maciejewski R, Michalska-Malecka K, Junemann AG, Rejdak R. Visual outcomes of posterior chamber intraocular lens intrascleral fixation in the setting of postoperative and posttraumatic aphakia. BMC Ophthalmol. 2016;16(1):50.CrossRef Haszcz D, Nowomiejska K, Oleszczuk A, Forlini C, Forlini M, Moneta-Wielgos J, Maciejewski R, Michalska-Malecka K, Junemann AG, Rejdak R. Visual outcomes of posterior chamber intraocular lens intrascleral fixation in the setting of postoperative and posttraumatic aphakia. BMC Ophthalmol. 2016;16(1):50.CrossRef
6.
go back to reference Malbran ES, Malbran E Jr, Negri I. Lens guide suture for transport and fixation in secondary IOL implantation after intracapsular extraction. Int Ophthalmol. 1986;9(2–3):151–60.CrossRef Malbran ES, Malbran E Jr, Negri I. Lens guide suture for transport and fixation in secondary IOL implantation after intracapsular extraction. Int Ophthalmol. 1986;9(2–3):151–60.CrossRef
7.
go back to reference Por YM, Lavin MJ. Techniques of intraocular lens suspension in the absence of capsular/zonular support. Surv Ophthalmol. 2005;50(5):429–62.CrossRef Por YM, Lavin MJ. Techniques of intraocular lens suspension in the absence of capsular/zonular support. Surv Ophthalmol. 2005;50(5):429–62.CrossRef
8.
go back to reference Loya N, Lichter H, Barash D, Goldenberg-Cohen N, Strassmann E, Weinberger D. Posterior chamber intraocular lens implantation after capsular tear: ultrasound biomicroscopy evaluation. J Cataract Refract Surg. 2001;27(9):1423–7.CrossRef Loya N, Lichter H, Barash D, Goldenberg-Cohen N, Strassmann E, Weinberger D. Posterior chamber intraocular lens implantation after capsular tear: ultrasound biomicroscopy evaluation. J Cataract Refract Surg. 2001;27(9):1423–7.CrossRef
9.
go back to reference Kumar DA, Agarwal A, Agarwal A, Chandrasekar R, Priyanka V. Long-term assessment of tilt of glued intraocular lenses: an optical coherence tomography analysis 5 years after surgery. Ophthalmology. 2015;122(1):48–55.CrossRef Kumar DA, Agarwal A, Agarwal A, Chandrasekar R, Priyanka V. Long-term assessment of tilt of glued intraocular lenses: an optical coherence tomography analysis 5 years after surgery. Ophthalmology. 2015;122(1):48–55.CrossRef
10.
go back to reference Chen SX, Lee LR, Sii F, Rowley A. Modified cow-hitch suture fixation of transscleral sutured posterior chamber intraocular lenses: long-term safety and efficacy. J Cataract Refract Surg. 2008;34(3):452–8.CrossRef Chen SX, Lee LR, Sii F, Rowley A. Modified cow-hitch suture fixation of transscleral sutured posterior chamber intraocular lenses: long-term safety and efficacy. J Cataract Refract Surg. 2008;34(3):452–8.CrossRef
11.
go back to reference Choi SR, Jeon JH, Kang JW, Heo JW. Risk factors for and management of pupillary intraocular lens capture after intraocular lens transscleral fixation. J Cataract Refract Surg. 2017;43(12):1557–62.CrossRef Choi SR, Jeon JH, Kang JW, Heo JW. Risk factors for and management of pupillary intraocular lens capture after intraocular lens transscleral fixation. J Cataract Refract Surg. 2017;43(12):1557–62.CrossRef
12.
go back to reference Hoffman RS, Fine IH, Packer M. Scleral fixation without conjunctival dissection. J Cataract Refract Surg. 2006;32(11):1907–12.CrossRef Hoffman RS, Fine IH, Packer M. Scleral fixation without conjunctival dissection. J Cataract Refract Surg. 2006;32(11):1907–12.CrossRef
13.
go back to reference Mannan R, Sinha R, Sharma N, Pruthi A, Titiyal JS, Vajpayee RB. Intrascleral reverse pocket approach of transconjunctival transscleral sulcus fixation of intraocular lens in eyes with ocular trauma. Eye Contact Lens. 2011;37(5):316–9.CrossRef Mannan R, Sinha R, Sharma N, Pruthi A, Titiyal JS, Vajpayee RB. Intrascleral reverse pocket approach of transconjunctival transscleral sulcus fixation of intraocular lens in eyes with ocular trauma. Eye Contact Lens. 2011;37(5):316–9.CrossRef
14.
go back to reference Wallmann AC, Monson BK, Adelberg DA. Transscleral fixation of a foldable posterior chamber intraocular lens. J Cataract Refract Surg. 2015;41(9):1804–9.CrossRef Wallmann AC, Monson BK, Adelberg DA. Transscleral fixation of a foldable posterior chamber intraocular lens. J Cataract Refract Surg. 2015;41(9):1804–9.CrossRef
15.
go back to reference Beltrame G, Driussi GB, Salvetat ML, Chizzolini M, Scuderi B. Original three-point fixation technique for sutured posterior chamber intraocular lens. Eur J Ophthalmol. 2002;12(3):219–24.CrossRef Beltrame G, Driussi GB, Salvetat ML, Chizzolini M, Scuderi B. Original three-point fixation technique for sutured posterior chamber intraocular lens. Eur J Ophthalmol. 2002;12(3):219–24.CrossRef
16.
go back to reference Ma DJ, Choi HJ, Kim MK, Wee WR. Clinical comparison of ciliary sulcus and pars plana locations for posterior chamber intraocular lens transscleral fixation. J Cataract Refract Surg. 2011;37(8):1439–46.CrossRef Ma DJ, Choi HJ, Kim MK, Wee WR. Clinical comparison of ciliary sulcus and pars plana locations for posterior chamber intraocular lens transscleral fixation. J Cataract Refract Surg. 2011;37(8):1439–46.CrossRef
17.
go back to reference Tanaka H, Fujinami K, Watanabe K, Noda T, Akiyama K. Haptic breakage after transscleral fixation of a single-piece acrylic intraocular lens. Case Rep Ophthalmol. 2014;5(2):212–6.CrossRef Tanaka H, Fujinami K, Watanabe K, Noda T, Akiyama K. Haptic breakage after transscleral fixation of a single-piece acrylic intraocular lens. Case Rep Ophthalmol. 2014;5(2):212–6.CrossRef
18.
go back to reference Budoff G, Miller CG, Halperin SJ, Jeng-Miller KW, Fine HF, Wheatley HM, Prenner JL. One-year outcomes of a novel technique for rescuing and scleral fixating a posterior dislocated intraocular Lens-bag complex without conjunctival opening (Hoffman pockets). Retina. 2016;36(10):1935–40.CrossRef Budoff G, Miller CG, Halperin SJ, Jeng-Miller KW, Fine HF, Wheatley HM, Prenner JL. One-year outcomes of a novel technique for rescuing and scleral fixating a posterior dislocated intraocular Lens-bag complex without conjunctival opening (Hoffman pockets). Retina. 2016;36(10):1935–40.CrossRef
19.
go back to reference Tong N, Liu F, Zhang T, Wang L, Zhou Z, Gong H, Yuan F. Pigment dispersion syndrome and pigmentary glaucoma after secondary sulcus transscleral fixation of single-piece foldable posterior chamber intraocular lenses in Chinese aphakic patients. J Cataract Refract Surg. 2017;43(5):639–42.CrossRef Tong N, Liu F, Zhang T, Wang L, Zhou Z, Gong H, Yuan F. Pigment dispersion syndrome and pigmentary glaucoma after secondary sulcus transscleral fixation of single-piece foldable posterior chamber intraocular lenses in Chinese aphakic patients. J Cataract Refract Surg. 2017;43(5):639–42.CrossRef
Metadata
Title
Clinical observation of a novel technique: transscleral suture fixation of a foldable 3-looped haptics one-piece posterior chamber intraocular lens implantation through scleral pockets with intact conjunctiva
Authors
Shuang Ni
Wei Wang
Xiang Chen
Xingdi Wu
Suhong He
Yajuan Ma
Wen Xu
Publication date
01-12-2019
Publisher
BioMed Central
Keyword
Incision
Published in
BMC Ophthalmology / Issue 1/2019
Electronic ISSN: 1471-2415
DOI
https://doi.org/10.1186/s12886-019-1113-2

Other articles of this Issue 1/2019

BMC Ophthalmology 1/2019 Go to the issue