Skip to main content
Top
Published in: European Spine Journal 8/2011

01-08-2011 | Original Article

In vivo preclinical evaluation of the influence of osteoporosis on the anchorage of different pedicle screw designs

Authors: Gianluca Giavaresi, Milena Fini, Roberto Giardino, Francesca Salamanna, Maria Sartori, Veronica Borsari, Silvia Spriano, Chiara M. Bellini, Marco Brayda-Bruno

Published in: European Spine Journal | Issue 8/2011

Login to get access

Abstract

We investigate the anchorage of pedicle screws with different surface treatments in osteoporotic bone. Eight ewes were divided into two groups of four animals each: four sheep underwent bilateral ovariectomy (OVX Group), whereas the operation was simulated in the remaining group (SHAM Group). Eighteen months after the first operation, the Dynesys® System was fitted to the sheep using pedicle screws with three different surface treatments: untreated, rough blasted (uncoated) and bioactive coated (bioactive). Uncoated screws showed a significantly higher bone ingrowth value compared with the untreated screws in the OVX group (9.3%, p < 0.005) and a significantly lower bone ingrowth value in the SHAM group (−11.0%, p < 0.05). Furthermore, the bioactive pedicle screws had a significant lower bone ingrowth value than the untreated screws in the SHAM group (−12.1%, p < 0.05). These results suggest that both tested surface treatments of pedicular screws may provide an advantage in terms of bone quality and osseointegration, when implanted in osteoporotic vertebrae.
Literature
14.
15.
go back to reference Fini M et al (2003) Biological assessment of the bone–screw interface after insertion of uncoated and hydroxyapatite-coated pedicular screws in osteopenic sheep. J Biomed Mater Res 66:176–183. doi:10.1002/jbm.a.10605 CrossRef Fini M et al (2003) Biological assessment of the bone–screw interface after insertion of uncoated and hydroxyapatite-coated pedicular screws in osteopenic sheep. J Biomed Mater Res 66:176–183. doi:10.​1002/​jbm.​a.​10605 CrossRef
16.
go back to reference Fini M et al (2003) Biomechanical and histomorphometric investigations on two morphologically differing titanium surfaces with and without fluorohydroxyapatite coating: an experimental study in sheep tibiae. Biomaterials 24:3182–3192. doi:10.1016/S0142-9612(03)00164-9 Fini M et al (2003) Biomechanical and histomorphometric investigations on two morphologically differing titanium surfaces with and without fluorohydroxyapatite coating: an experimental study in sheep tibiae. Biomaterials 24:3182–3192. doi:10.​1016/​S0142-9612(03)00164-9
19.
go back to reference Nicoli Aldini N et al (2004) Osseointegration of bioactive glass-coated and uncoated zirconia in osteopenic bone: an in vivo experimental study. J Biomed Mater Res 68A(2):264–272. doi:10.1002/jbm.a.20057 CrossRef Nicoli Aldini N et al (2004) Osseointegration of bioactive glass-coated and uncoated zirconia in osteopenic bone: an in vivo experimental study. J Biomed Mater Res 68A(2):264–272. doi:10.​1002/​jbm.​a.​20057 CrossRef
25.
go back to reference Chappard D et al (1999) The early remodeling phases around titanium implants: a histomorphometric assessment of bone quality in a 3- and 6-month study in sheep. Int J Oral Maxillofac Implants 14:189–196PubMed Chappard D et al (1999) The early remodeling phases around titanium implants: a histomorphometric assessment of bone quality in a 3- and 6-month study in sheep. Int J Oral Maxillofac Implants 14:189–196PubMed
31.
go back to reference Fini M et al (2000) The ovariectomized sheep as a model for testing biomaterials and prosthetic devices in osteopenic bone: a preliminary study on iliac crest biopsies. Int J Artif Organs 23:275–281PubMed Fini M et al (2000) The ovariectomized sheep as a model for testing biomaterials and prosthetic devices in osteopenic bone: a preliminary study on iliac crest biopsies. Int J Artif Organs 23:275–281PubMed
32.
go back to reference Giavaresi G et al (2001) The ovariectomized ewe model in the evaluation of biomaterials for prosthetic devices in spinal fixation. Int J Artif Organs 24:814–820PubMed Giavaresi G et al (2001) The ovariectomized ewe model in the evaluation of biomaterials for prosthetic devices in spinal fixation. Int J Artif Organs 24:814–820PubMed
33.
go back to reference Turner et al (1993) Static and dynamic histomorphometric data in 9-to 11-years old ewes. Poster Session Abstracts-ACVS: 413 Turner et al (1993) Static and dynamic histomorphometric data in 9-to 11-years old ewes. Poster Session Abstracts-ACVS: 413
35.
go back to reference Wilke HJ et al (1997) Are sheep spines a valid biomechanical model for human spines? Spine 2:2365–2374CrossRef Wilke HJ et al (1997) Are sheep spines a valid biomechanical model for human spines? Spine 2:2365–2374CrossRef
Metadata
Title
In vivo preclinical evaluation of the influence of osteoporosis on the anchorage of different pedicle screw designs
Authors
Gianluca Giavaresi
Milena Fini
Roberto Giardino
Francesca Salamanna
Maria Sartori
Veronica Borsari
Silvia Spriano
Chiara M. Bellini
Marco Brayda-Bruno
Publication date
01-08-2011
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 8/2011
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-011-1831-5

Other articles of this Issue 8/2011

European Spine Journal 8/2011 Go to the issue