In vivo evaluation of DSAEK interface with scanning-laser confocal microscopy

Authors: Giulio Ferrari, Verena Reichegger, Luca Ludergnani, Elisabetta Delfini, Claudio Macaluso

Published in: BMC Ophthalmology | Issue 1/2012

Login to get access

Abstract

Background

Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) allows selective replacement of the endothelium. Post-operative haze and particles can affect the interface quality and, ultimately, visual outcome. In this study, we evaluated DSAEK interface with in vivo laser confocal microscopy (LCM) in order to: (i) correlate interface status with best corrected visual acuity, and (ii) with time from surgery; (iii) correlate interface particle number with best corrected visual acuity. Host-donor interface was imaged and graded using a published reflectivity scale. Particles at the interface were counted.

Methods

18 eyes of 16 patients (6 males and 10 females); mean age: 74 ± 8.3 years which underwent DSAEK were examined by means of in vivo laser confocal microscopy between 1 and 24 months after surgery. Host-donor interface was imaged and graded using a published reflectivity scale. Particles present at the interface were counted.

Results

Interface reflectivity was 2.17 ± 1.2 and significantly correlated with visual acuity (Spearman correlation coefficient −0.83; P < 0.001), and with time after surgery (Spearman correlation coefficient −0.87; P < 0.001). Visual acuity was 0.67 ± 0.27. The number of particles was 205 ± 117.8; no correlation was found between this number and visual acuity (Spearman correlation coefficient −0.41; P = 0.15).

Conclusion

DSAEK interface imaged with LCM is helpful in diagnosing poor host-donor interface quality in DSAEK surgery. A good quality interface is related to a better visual acuity. Moreover, the quality of the interface appears to improve as time passes from the surgery. Interface quality is related with visual acuity and improves with time from surgery. LCM should be considered as an added tool in post-DSAEK follow-up of patients. Finally, our study shows that the presence of particles does not influence visual outcome.
Appendix
Available only for authorised users
Literature
1.
go back to reference Chen ES, Terry MA, Shamie N, Chen ES, Terry MA, Shamie N, Hoar KL, Friend DJ: Descemet-stripping automated endothelial keratoplasty: six-month results in a prospective study of 100 eyes. Cornea. 2008, 27: 514-520. 10.1097/ICO.0b013e3181611c50.CrossRefPubMed Chen ES, Terry MA, Shamie N, Chen ES, Terry MA, Shamie N, Hoar KL, Friend DJ: Descemet-stripping automated endothelial keratoplasty: six-month results in a prospective study of 100 eyes. Cornea. 2008, 27: 514-520. 10.1097/ICO.0b013e3181611c50.CrossRefPubMed
2.
go back to reference Koenig SB, Covert DJ: Early results of small-incision Descemet's stripping and automated endothelial keratoplasty. Ophthalmology. 2007, 114: 221-226. 10.1016/j.ophtha.2006.07.056.CrossRefPubMed Koenig SB, Covert DJ: Early results of small-incision Descemet's stripping and automated endothelial keratoplasty. Ophthalmology. 2007, 114: 221-226. 10.1016/j.ophtha.2006.07.056.CrossRefPubMed
3.
go back to reference Koenig SB, Covert DJ, Dupps WJ, Meisler DM: Visual acuity, refractive error, and endothelial cell density six months after Descemet stripping and automated endothelial keratoplasty (DSAEK). Cornea. 2007, 26: 670-674. 10.1097/ICO.0b013e3180544902.CrossRefPubMed Koenig SB, Covert DJ, Dupps WJ, Meisler DM: Visual acuity, refractive error, and endothelial cell density six months after Descemet stripping and automated endothelial keratoplasty (DSAEK). Cornea. 2007, 26: 670-674. 10.1097/ICO.0b013e3180544902.CrossRefPubMed
4.
go back to reference Bahar I, Kaiserman I, Levinger E, Sansanayudh W, Slomovic AR, Rootman DS: Retrospective contralateral study comparing descemet stripping automated endothelial keratoplasty with penetrating keratoplasty. Cornea. 2009, 28: 485-488. 10.1097/ICO.0b013e3181901df4.CrossRefPubMed Bahar I, Kaiserman I, Levinger E, Sansanayudh W, Slomovic AR, Rootman DS: Retrospective contralateral study comparing descemet stripping automated endothelial keratoplasty with penetrating keratoplasty. Cornea. 2009, 28: 485-488. 10.1097/ICO.0b013e3181901df4.CrossRefPubMed
5.
go back to reference Kaufman SC, Musch DC, Belin MW, Cohen EJ, Meisler DM, Reinhart WJ, Udell IJ, Van Meter WS: Confocal microscopy: a report by the American Academy of Ophthalmology. Ophthalmology. 2004, 111: 396-406. 10.1016/j.ophtha.2003.12.002.CrossRefPubMed Kaufman SC, Musch DC, Belin MW, Cohen EJ, Meisler DM, Reinhart WJ, Udell IJ, Van Meter WS: Confocal microscopy: a report by the American Academy of Ophthalmology. Ophthalmology. 2004, 111: 396-406. 10.1016/j.ophtha.2003.12.002.CrossRefPubMed
6.
go back to reference Stave J, Zinser G, Grümmer G, Guthoff R: Modified Heidelberg Retinal Tomograph HRT. Initial results of in vivo presentation of corneal structures. Ophthalmologe. 2002, 99: 276-280. 10.1007/s003470100535.CrossRefPubMed Stave J, Zinser G, Grümmer G, Guthoff R: Modified Heidelberg Retinal Tomograph HRT. Initial results of in vivo presentation of corneal structures. Ophthalmologe. 2002, 99: 276-280. 10.1007/s003470100535.CrossRefPubMed
7.
go back to reference Kobayashi A, Yokogawa H, Sugiyama K: In vivo laser confocal microscopy of Bowman's layer of the cornea. Ophthalmology. 2006, 113: 2203-2208. 10.1016/j.ophtha.2006.05.058.CrossRefPubMed Kobayashi A, Yokogawa H, Sugiyama K: In vivo laser confocal microscopy of Bowman's layer of the cornea. Ophthalmology. 2006, 113: 2203-2208. 10.1016/j.ophtha.2006.05.058.CrossRefPubMed
8.
go back to reference Kobayashi A, Sugiyama K: In vivo laser confocal microscopy findings for Bowman's layer dystrophies (Thiel-Behnke and Reis-Bucklers corneal dystrophies). Ophthalmology. 2007, 114: 69-75. 10.1016/j.ophtha.2006.05.076.CrossRefPubMed Kobayashi A, Sugiyama K: In vivo laser confocal microscopy findings for Bowman's layer dystrophies (Thiel-Behnke and Reis-Bucklers corneal dystrophies). Ophthalmology. 2007, 114: 69-75. 10.1016/j.ophtha.2006.05.076.CrossRefPubMed
9.
go back to reference Macaluso C: Closed-chamber pulling-injection system for donor graft insertion in endothelial keratoplasty. J Cataract Refract Surg. 2008, 34: 353-356. 10.1016/j.jcrs.2007.11.019.CrossRefPubMed Macaluso C: Closed-chamber pulling-injection system for donor graft insertion in endothelial keratoplasty. J Cataract Refract Surg. 2008, 34: 353-356. 10.1016/j.jcrs.2007.11.019.CrossRefPubMed
10.
go back to reference Ferrari G, Tedesco S, Delfini E, Macaluso C: Laser Scanning In Vivo Confocal Microscopy in a Case of Terrien Marginal Degeneration. Cornea. 2010, 29 (4): 471-475.PubMed Ferrari G, Tedesco S, Delfini E, Macaluso C: Laser Scanning In Vivo Confocal Microscopy in a Case of Terrien Marginal Degeneration. Cornea. 2010, 29 (4): 471-475.PubMed
11.
go back to reference Kobayashi A, Mawatari Y, Yokogawa H, Sugiyama K: In vivo laser confocal microscopy after descemet stripping with automated endothelial keratoplasty. Am J Ophthalmol. 2008, 145: 977-985. 10.1016/j.ajo.2008.02.009.CrossRefPubMed Kobayashi A, Mawatari Y, Yokogawa H, Sugiyama K: In vivo laser confocal microscopy after descemet stripping with automated endothelial keratoplasty. Am J Ophthalmol. 2008, 145: 977-985. 10.1016/j.ajo.2008.02.009.CrossRefPubMed
12.
go back to reference Uchino Y, Shimmura S, Yamaguchi T, Kawakita T, Matsumoto Y, Negishi K, Tsubota K: Comparison of corneal thickness and haze in DSAEK and penetrating keratoplasty. Cornea. 2011, 30 (3): 287-290. 10.1097/ICO.0b013e3181eeafd6.CrossRefPubMed Uchino Y, Shimmura S, Yamaguchi T, Kawakita T, Matsumoto Y, Negishi K, Tsubota K: Comparison of corneal thickness and haze in DSAEK and penetrating keratoplasty. Cornea. 2011, 30 (3): 287-290. 10.1097/ICO.0b013e3181eeafd6.CrossRefPubMed
13.
go back to reference Meek KM, Leonard DW, Connon CJ, Dennis S, Khan S: Transparency, swelling and scarring in the corneal stroma. Eye (Lond). 2003, 17 (8): 927-936. 10.1038/sj.eye.6700574.CrossRef Meek KM, Leonard DW, Connon CJ, Dennis S, Khan S: Transparency, swelling and scarring in the corneal stroma. Eye (Lond). 2003, 17 (8): 927-936. 10.1038/sj.eye.6700574.CrossRef
14.
go back to reference Shulman J, Kropinak M, Ritterband DC, Perry HD, Seedor JA, McCormick SA, Milman T: Failed descemet-stripping automated endothelial keratoplasty grafts: a clinicopathologic analysis. Am J Ophthalmol. 2009, 148 (e2): 752-759.CrossRefPubMed Shulman J, Kropinak M, Ritterband DC, Perry HD, Seedor JA, McCormick SA, Milman T: Failed descemet-stripping automated endothelial keratoplasty grafts: a clinicopathologic analysis. Am J Ophthalmol. 2009, 148 (e2): 752-759.CrossRefPubMed
15.
go back to reference Oster SF, Ebrahimi KB, Eberhart CG, Schein OD, Stark WJ, Jun AS: A clinicopathologic series of primary graft failure after Descemet's stripping and automated endothelial keratoplasty. Ophthalmology. 2009, 116: 609-614. 10.1016/j.ophtha.2008.08.036.CrossRefPubMed Oster SF, Ebrahimi KB, Eberhart CG, Schein OD, Stark WJ, Jun AS: A clinicopathologic series of primary graft failure after Descemet's stripping and automated endothelial keratoplasty. Ophthalmology. 2009, 116: 609-614. 10.1016/j.ophtha.2008.08.036.CrossRefPubMed
16.
go back to reference Sbarbaro JA, Eagle RC, Thumma P, Raber IM: Histopathology of posterior lamellar endothelial keratoplasty graft failure. Cornea. 2008, 27: 900-904. 10.1097/ICO.0b013e318170aeb7.CrossRefPubMed Sbarbaro JA, Eagle RC, Thumma P, Raber IM: Histopathology of posterior lamellar endothelial keratoplasty graft failure. Cornea. 2008, 27: 900-904. 10.1097/ICO.0b013e318170aeb7.CrossRefPubMed
17.
go back to reference Espana EM, Huang B: Confocal microscopy study of donor-recipient interface after Descemet's stripping with endothelial keratoplasty. Br J Ophthalmol. 2010, 94: 903-908. 10.1136/bjo.2009.165712.CrossRefPubMed Espana EM, Huang B: Confocal microscopy study of donor-recipient interface after Descemet's stripping with endothelial keratoplasty. Br J Ophthalmol. 2010, 94: 903-908. 10.1136/bjo.2009.165712.CrossRefPubMed
18.
go back to reference Prasher P, Muftuoglu O, Bowman RW, McCulley JP, Petroll WM, Cavanagh HD, Mootha VV: Tandem scanning confocal microscopy of cornea after descemet stripping automated endothelial keratoplasty. Eye Contact Lens. 2009, 35: 196-202. 10.1097/ICL.0b013e3181abb596.CrossRefPubMed Prasher P, Muftuoglu O, Bowman RW, McCulley JP, Petroll WM, Cavanagh HD, Mootha VV: Tandem scanning confocal microscopy of cornea after descemet stripping automated endothelial keratoplasty. Eye Contact Lens. 2009, 35: 196-202. 10.1097/ICL.0b013e3181abb596.CrossRefPubMed
19.
go back to reference Kaufman SC, Kaufman HE: How has confocal microscopy helped us in refractive surgery?. Curr Opin Ophthalmol. 2006, 17: 380-388. 10.1097/01.icu.0000233959.73262.99.CrossRefPubMed Kaufman SC, Kaufman HE: How has confocal microscopy helped us in refractive surgery?. Curr Opin Ophthalmol. 2006, 17: 380-388. 10.1097/01.icu.0000233959.73262.99.CrossRefPubMed
20.
go back to reference Perez-Gomez I, Cameron I, Efron N: Particles at the laser in situ keratomileusis flap interface. J Cataract Refract Surg. 2004, 30: 2021-CrossRefPubMed Perez-Gomez I, Cameron I, Efron N: Particles at the laser in situ keratomileusis flap interface. J Cataract Refract Surg. 2004, 30: 2021-CrossRefPubMed
21.
go back to reference Dawson DG, Edelhauser HF, Grossniklaus HE: Long-term histopathologic findings in human corneal wounds after refractive surgical procedures. Am J Ophthalmol. 2005, 139: 168-178. 10.1016/j.ajo.2004.08.078.CrossRefPubMed Dawson DG, Edelhauser HF, Grossniklaus HE: Long-term histopathologic findings in human corneal wounds after refractive surgical procedures. Am J Ophthalmol. 2005, 139: 168-178. 10.1016/j.ajo.2004.08.078.CrossRefPubMed
22.
go back to reference Ivarsen A, Thøgersen J, Keiding SR, Hjortdal JØ, Møller-Pedersen T: Plastic particles at the LASIK interface. Ophthalmology. 2004, 111: 18-23. 10.1016/j.ophtha.2003.05.021.CrossRefPubMed Ivarsen A, Thøgersen J, Keiding SR, Hjortdal JØ, Møller-Pedersen T: Plastic particles at the LASIK interface. Ophthalmology. 2004, 111: 18-23. 10.1016/j.ophtha.2003.05.021.CrossRefPubMed
23.
go back to reference Hu MY, McCulley JP, Cavanagh HD, Bowman RW, Verity SM, Mootha VV, Petroll WM: Comparison of the corneal response to laser in situ keratomileusis with flap creation using the FS15 and FS30 femtosecond lasers: clinical and confocal microscopy findings. J Cataract Refract Surg. 2007, 33: 673-681. 10.1016/j.jcrs.2006.12.021.CrossRefPubMed Hu MY, McCulley JP, Cavanagh HD, Bowman RW, Verity SM, Mootha VV, Petroll WM: Comparison of the corneal response to laser in situ keratomileusis with flap creation using the FS15 and FS30 femtosecond lasers: clinical and confocal microscopy findings. J Cataract Refract Surg. 2007, 33: 673-681. 10.1016/j.jcrs.2006.12.021.CrossRefPubMed
24.
go back to reference Kobayashi A, Yokogawa H, Sugiyama K: In vivo laser confocal microscopy after non-Descemet's stripping automated endothelial keratoplasty. Ophthalmology. 2009, 116: 1306-1313. 10.1016/j.ophtha.2009.01.053.CrossRefPubMed Kobayashi A, Yokogawa H, Sugiyama K: In vivo laser confocal microscopy after non-Descemet's stripping automated endothelial keratoplasty. Ophthalmology. 2009, 116: 1306-1313. 10.1016/j.ophtha.2009.01.053.CrossRefPubMed
Metadata
Title
In vivo evaluation of DSAEK interface with scanning-laser confocal microscopy
Authors
Giulio Ferrari
Verena Reichegger
Luca Ludergnani
Elisabetta Delfini
Claudio Macaluso
Publication date
01-12-2012
Publisher
BioMed Central
Published in
BMC Ophthalmology / Issue 1/2012
Electronic ISSN: 1471-2415
DOI
https://doi.org/10.1186/1471-2415-12-32

Other articles of this Issue 1/2012

BMC Ophthalmology 1/2012 Go to the issue