Abstract

Background

The evaluation of any new cardiac valvular prosthesis should go beyond the classical morbidity and mortality rates and involve hemodynamic assessment. As a proof of concept, the objective of this study was to characterise for the first time the hemodynamics and the blood flow profiles at the aortic root in patients implanted with BioValsalva™ composite valve-conduit using comprehensive MRI and computer technologies.

Methods

Four male patients implanted with BioValsalva™ and 2 age-matched normal controls (NC) underwent cardiac magnetic resonance imaging (MRI). Phase-contrast imaging with velocity-mapping in 3 orthogonal directions was performed at the level of the aortic root and descending thoracic aorta. Computational fluid dynamic (CFD) simulations were performed for all the subjects with patient-specific flow information derived from phase-contrast MR data.

Results

The maximum and mean flow rates throughout the cardiac cycle at the aortic root level were very comparable between NC and BioValsalva™ patients (541 ± 199 vs. 567 ± 75 ml/s) and (95 ± 46 vs. 96 ± 10 ml/s), respectively. The maximum velocity (cm/s) was higher in patients (314 ± 49 vs. 223 ± 20; P = 0.06) due to relatively smaller effective orifice area (EOA), 2.99 ± 0.47 vs. 4.40 ± 0.24 cm2 (P = 0.06), however, the BioValsalva™ EOA was comparable to other reported prosthesis. The cross-sectional area and maximum diameter at the root were comparable between the two groups. BioValsalva™ conduit was stiffer than the native aortic wall, compliance (mm2 • mmHg−1 • 10−3) values were (12.6 ± 4.2 vs 25.3 ± 0.4.; P = 0.06). The maximum time-averaged wall shear stress (Pa), at the ascending aorta was equivalent between the two groups, 17.17 ± 2.7 (NC) vs. 17.33 ± 4.7 (BioValsalva™ ). Flow streamlines at the root and ascending aorta were also similar between the two groups apart from a degree of helical flow that occurs at the outer curvature at the angle developed near the suture line.

Conclusions

BioValsalva™ composite valve-conduit prosthesis is potentially comparable to native aortic root in structural design and in many hemodynamic parameters, although it is stiffer. Surgeons should pay more attention to the surgical technique to maximise the reestablishment of normal smooth aortic curvature geometry to prevent unfavourable flow characteristics.
Appendix
Available only for authorised users
Literature
1.
go back to reference Zannis K, Deux JF, Tzvetkov B, Nakashima K, Loisance D, Rahmouni A, Kirsch ME: Composite freestyle stentless xenograft with Dacron graft extension for ascending aortic replacement. Ann Thorac Surg. 2009, 87: 1789-1794. 10.1016/j.athoracsur.2009.03.069.CrossRefPubMed Zannis K, Deux JF, Tzvetkov B, Nakashima K, Loisance D, Rahmouni A, Kirsch ME: Composite freestyle stentless xenograft with Dacron graft extension for ascending aortic replacement. Ann Thorac Surg. 2009, 87: 1789-1794. 10.1016/j.athoracsur.2009.03.069.CrossRefPubMed
2.
go back to reference Hagl C, Strauch JT, Spielvogel D, Galla JD, Lansman SL, Squitieri R, Bodian CA, Griepp RB: Is the Bentall procedure for ascending aorta or aortic valve replacement the best approach for long-term event-free survival?. Ann Thorac Surg. 2003, 76: 698-703. 10.1016/S0003-4975(03)00568-X.CrossRefPubMed Hagl C, Strauch JT, Spielvogel D, Galla JD, Lansman SL, Squitieri R, Bodian CA, Griepp RB: Is the Bentall procedure for ascending aorta or aortic valve replacement the best approach for long-term event-free survival?. Ann Thorac Surg. 2003, 76: 698-703. 10.1016/S0003-4975(03)00568-X.CrossRefPubMed
3.
go back to reference Zehr KJ, Orszulak TA, Mullany CJ, Matloobi A, Daly RC, Dearani JA, Sundt TM, Puga FJ, Danielson GK, Schaff HV: Surgery for aneurysms of the aortic root: a 30-year experience. Circulation. 2004, 110: 1364-1371. 10.1161/01.CIR.0000141593.05085.87.CrossRefPubMed Zehr KJ, Orszulak TA, Mullany CJ, Matloobi A, Daly RC, Dearani JA, Sundt TM, Puga FJ, Danielson GK, Schaff HV: Surgery for aneurysms of the aortic root: a 30-year experience. Circulation. 2004, 110: 1364-1371. 10.1161/01.CIR.0000141593.05085.87.CrossRefPubMed
4.
go back to reference Borger MA, Carson SM, Ivanov J, Rao V, Scully HE, Feindel CM, David TE: Stentless aortic valves are hemodynamically superior to stented valves during mid-term follow-up: a large retrospective study. Ann Thorac Surg. 2005, 80: 2180-2185. 10.1016/j.athoracsur.2005.05.055.CrossRefPubMed Borger MA, Carson SM, Ivanov J, Rao V, Scully HE, Feindel CM, David TE: Stentless aortic valves are hemodynamically superior to stented valves during mid-term follow-up: a large retrospective study. Ann Thorac Surg. 2005, 80: 2180-2185. 10.1016/j.athoracsur.2005.05.055.CrossRefPubMed
5.
go back to reference Bakhtiary F, Schiemann M, Dzemali O, Dogan S, Schachinger V, Ackermann H, Moritz A, Kleine P: Impact of patient-prosthesis mismatch and aortic valve design on coronary flow reserve after aortic valve replacement. J Am Coll Cardiol. 2007, 49: 790-796. 10.1016/j.jacc.2006.10.052.CrossRefPubMed Bakhtiary F, Schiemann M, Dzemali O, Dogan S, Schachinger V, Ackermann H, Moritz A, Kleine P: Impact of patient-prosthesis mismatch and aortic valve design on coronary flow reserve after aortic valve replacement. J Am Coll Cardiol. 2007, 49: 790-796. 10.1016/j.jacc.2006.10.052.CrossRefPubMed
6.
go back to reference Yacoub M, Rasmi NR, Sundt TM, Lund O, Boyland E, Radley-Smith R, Khaghani A, Mitchell A: Fourteen-year experience with homovital homografts for aortic valve replacement. J Thorac Cardiovasc Surg. 1995, 110: 186-193. 10.1016/S0022-5223(05)80025-X.CrossRefPubMed Yacoub M, Rasmi NR, Sundt TM, Lund O, Boyland E, Radley-Smith R, Khaghani A, Mitchell A: Fourteen-year experience with homovital homografts for aortic valve replacement. J Thorac Cardiovasc Surg. 1995, 110: 186-193. 10.1016/S0022-5223(05)80025-X.CrossRefPubMed
7.
go back to reference Melina G, De Robertis F, Gaer JA, Amrani M, Khaghani A, Yacoub MH: Mid-term pattern of survival, hemodynamic performance and rate of complications after medtronic freestyle versus homograft full aortic root replacement: results from a prospective randomized trial. J Heart Valve Dis. 2004, 13: 972-975.PubMed Melina G, De Robertis F, Gaer JA, Amrani M, Khaghani A, Yacoub MH: Mid-term pattern of survival, hemodynamic performance and rate of complications after medtronic freestyle versus homograft full aortic root replacement: results from a prospective randomized trial. J Heart Valve Dis. 2004, 13: 972-975.PubMed
8.
go back to reference Beck A, Thubrikar MJ, Robicsek F: Stress analysis of the aortic valve with and without the sinuses of valsalva. J Heart Valve Dis. 2001, 10: 1-11.PubMed Beck A, Thubrikar MJ, Robicsek F: Stress analysis of the aortic valve with and without the sinuses of valsalva. J Heart Valve Dis. 2001, 10: 1-11.PubMed
9.
go back to reference Katayama S, Umetani N, Sugiura S, Hisada T: The sinus of Valsalva relieves abnormal stress on aortic valve leaflets by facilitating smooth closure. J Thorac Cardiovasc Surg. 2008, 136: 1528-1535. 10.1016/j.jtcvs.2008.05.054.CrossRefPubMed Katayama S, Umetani N, Sugiura S, Hisada T: The sinus of Valsalva relieves abnormal stress on aortic valve leaflets by facilitating smooth closure. J Thorac Cardiovasc Surg. 2008, 136: 1528-1535. 10.1016/j.jtcvs.2008.05.054.CrossRefPubMed
10.
go back to reference Weltert L, De Paulis R, Scaffa R, Maselli D, Bellisario A, D'Alessandro S: Re-creation of a sinuslike graft expansion in Bentall procedure reduces stress at the coronary button anastomoses: A finite element study. J Thorac Cardiovasc Surg. 2009, 137: 1082-1087. 10.1016/j.jtcvs.2008.10.013.CrossRefPubMed Weltert L, De Paulis R, Scaffa R, Maselli D, Bellisario A, D'Alessandro S: Re-creation of a sinuslike graft expansion in Bentall procedure reduces stress at the coronary button anastomoses: A finite element study. J Thorac Cardiovasc Surg. 2009, 137: 1082-1087. 10.1016/j.jtcvs.2008.10.013.CrossRefPubMed
11.
go back to reference de Paulis R, Tomai F, Bertoldo F, Ghini AS, Scaffa R, Nardi P, Chiariello L: Coronary flow characteristics after a Bentall procedure with or without sinuses of Valsalva. Eur J Cardiothorac Surg. 2004, 26: 66-72. 10.1016/j.ejcts.2004.04.031.CrossRefPubMed de Paulis R, Tomai F, Bertoldo F, Ghini AS, Scaffa R, Nardi P, Chiariello L: Coronary flow characteristics after a Bentall procedure with or without sinuses of Valsalva. Eur J Cardiothorac Surg. 2004, 26: 66-72. 10.1016/j.ejcts.2004.04.031.CrossRefPubMed
12.
go back to reference Bara CL, Verhey JF: Simulation of the fluid dynamics in artificial aortic roots: comparison of two different types of prostheses. J Artif Organs. 2008, 11: 123-129. 10.1007/s10047-008-0416-5.CrossRefPubMed Bara CL, Verhey JF: Simulation of the fluid dynamics in artificial aortic roots: comparison of two different types of prostheses. J Artif Organs. 2008, 11: 123-129. 10.1007/s10047-008-0416-5.CrossRefPubMed
13.
go back to reference Di Bartolomeo R, Botta L, Leone A, Pilato E, Martin-Suarez S, Bacchini M, Pacini D: Bio-Valsalva prosthesis: 'new' conduit for 'old' patients. Interact Cardiovasc Thorac Surg. 2008, 7: 1062-1066. 10.1510/icvts.2008.187849.CrossRefPubMed Di Bartolomeo R, Botta L, Leone A, Pilato E, Martin-Suarez S, Bacchini M, Pacini D: Bio-Valsalva prosthesis: 'new' conduit for 'old' patients. Interact Cardiovasc Thorac Surg. 2008, 7: 1062-1066. 10.1510/icvts.2008.187849.CrossRefPubMed
14.
go back to reference Kaya A, Heijmen RH, Kelder JC, Morshuis WJ: First 102 patients with the BioValsalva conduit for aortic root replacement. Ann Thorac Surg. 2012, 94: 72-77. 10.1016/j.athoracsur.2012.03.032.CrossRefPubMed Kaya A, Heijmen RH, Kelder JC, Morshuis WJ: First 102 patients with the BioValsalva conduit for aortic root replacement. Ann Thorac Surg. 2012, 94: 72-77. 10.1016/j.athoracsur.2012.03.032.CrossRefPubMed
15.
go back to reference Bochenek-Klimczyk K, Lau KK, Galinanes M, Sosnowski AW: Preassembled stentless valved-conduit for the replacement of the ascending aorta and aortic root. Interact Cardiovasc Thorac Surg. 2008, 7: 964-968. 10.1510/icvts.2008.184457.CrossRefPubMed Bochenek-Klimczyk K, Lau KK, Galinanes M, Sosnowski AW: Preassembled stentless valved-conduit for the replacement of the ascending aorta and aortic root. Interact Cardiovasc Thorac Surg. 2008, 7: 964-968. 10.1510/icvts.2008.184457.CrossRefPubMed
16.
go back to reference Lau KK, Bochenek-Klimczyk K, Galinanes M, Sosnowski AW: Replacement of the ascending aorta, aortic root, and valve with a novel stentless valved conduit. Ann Thorac Surg. 2008, 86: 278-281. 10.1016/j.athoracsur.2008.01.058.CrossRefPubMed Lau KK, Bochenek-Klimczyk K, Galinanes M, Sosnowski AW: Replacement of the ascending aorta, aortic root, and valve with a novel stentless valved conduit. Ann Thorac Surg. 2008, 86: 278-281. 10.1016/j.athoracsur.2008.01.058.CrossRefPubMed
17.
go back to reference Giannakoulas G, Dimopoulos K, Xu XY: Modelling in congenital heart disease. Art or science?. Int J Cardiol. 2009, 133: 141-144. 10.1016/j.ijcard.2008.10.039.CrossRefPubMed Giannakoulas G, Dimopoulos K, Xu XY: Modelling in congenital heart disease. Art or science?. Int J Cardiol. 2009, 133: 141-144. 10.1016/j.ijcard.2008.10.039.CrossRefPubMed
18.
go back to reference Torii R, El-Hamamsy I, Donya M, Babu-Narayan SV, Ibrahim M, Kilner PJ, Mohiaddin RH, Xu XY, Yacoub MH: Integrated morphologic and functional assessment of the aortic root after different tissue valve root replacement procedures. J Thorac Cardiovasc Surg. 2012, 143: 1422-1428. 10.1016/j.jtcvs.2011.12.034.CrossRefPubMed Torii R, El-Hamamsy I, Donya M, Babu-Narayan SV, Ibrahim M, Kilner PJ, Mohiaddin RH, Xu XY, Yacoub MH: Integrated morphologic and functional assessment of the aortic root after different tissue valve root replacement procedures. J Thorac Cardiovasc Surg. 2012, 143: 1422-1428. 10.1016/j.jtcvs.2011.12.034.CrossRefPubMed
19.
go back to reference Lowe A, Harrison W, El-Aklouk E, Ruygrok P, Al-Jumaily AM: Non-invasive model-based estimation of aortic pulse pressure using suprasystolic brachial pressure waveforms. J Biomech. 2009, 42: 2111-2115. 10.1016/j.jbiomech.2009.05.029.CrossRefPubMed Lowe A, Harrison W, El-Aklouk E, Ruygrok P, Al-Jumaily AM: Non-invasive model-based estimation of aortic pulse pressure using suprasystolic brachial pressure waveforms. J Biomech. 2009, 42: 2111-2115. 10.1016/j.jbiomech.2009.05.029.CrossRefPubMed
20.
go back to reference Lin AC, Lowe A, Sidhu K, Harrison W, Ruygrok P, Stewart R: Evaluation of a novel sphygmomanometer, which estimates central aortic blood pressure from analysis of brachial artery suprasystolic pressure waves. J Hypertens. 2012, 30: 1743-1750. 10.1097/HJH.0b013e3283567b94.CrossRefPubMed Lin AC, Lowe A, Sidhu K, Harrison W, Ruygrok P, Stewart R: Evaluation of a novel sphygmomanometer, which estimates central aortic blood pressure from analysis of brachial artery suprasystolic pressure waves. J Hypertens. 2012, 30: 1743-1750. 10.1097/HJH.0b013e3283567b94.CrossRefPubMed
21.
go back to reference Xu J, Shiota T, Omoto R, Zhou X, Kyo S, Ishii M, Rice MJ, Sahn DJ: Intravascular ultrasound assessment of regional aortic wall stiffness, distensibility, and compliance in patients with coarctation of the aorta. Am Heart J. 1997, 134: 93-98. 10.1016/S0002-8703(97)70111-X.CrossRefPubMed Xu J, Shiota T, Omoto R, Zhou X, Kyo S, Ishii M, Rice MJ, Sahn DJ: Intravascular ultrasound assessment of regional aortic wall stiffness, distensibility, and compliance in patients with coarctation of the aorta. Am Heart J. 1997, 134: 93-98. 10.1016/S0002-8703(97)70111-X.CrossRefPubMed
22.
go back to reference Cheng Z, Tan FP, Riga CV, Bicknell CD, Hamady MS, Gibbs RG, Wood NB, Xu XY: Analysis of flow patterns in a patient-specific aortic dissection model. J Biomech Eng. 2010, 132: 051007-10.1115/1.4000964.CrossRefPubMed Cheng Z, Tan FP, Riga CV, Bicknell CD, Hamady MS, Gibbs RG, Wood NB, Xu XY: Analysis of flow patterns in a patient-specific aortic dissection model. J Biomech Eng. 2010, 132: 051007-10.1115/1.4000964.CrossRefPubMed
23.
go back to reference Moorjani N, Modi A, Mattam K, Barlow C, Tsang G, Haw M, Livesey S, Ohri S: Aortic root replacement using a biovalsalva prosthesis in comparison to a "handsewn" composite bioprosthesis. J Card Surg. 2010, 25: 321-326. 10.1111/j.1540-8191.2010.01015.x.CrossRefPubMed Moorjani N, Modi A, Mattam K, Barlow C, Tsang G, Haw M, Livesey S, Ohri S: Aortic root replacement using a biovalsalva prosthesis in comparison to a "handsewn" composite bioprosthesis. J Card Surg. 2010, 25: 321-326. 10.1111/j.1540-8191.2010.01015.x.CrossRefPubMed
24.
go back to reference Lee RT, Kamm RD: Vascular mechanics for the cardiologist. J Am Coll Cardiol. 1994, 23: 1289-1295. 10.1016/0735-1097(94)90369-7.CrossRefPubMed Lee RT, Kamm RD: Vascular mechanics for the cardiologist. J Am Coll Cardiol. 1994, 23: 1289-1295. 10.1016/0735-1097(94)90369-7.CrossRefPubMed
Metadata
Title
In-vivo assessment of the morphology and hemodynamic functions of the BioValsalva™ composite valve-conduit graft using cardiac magnetic resonance imaging and computational modelling technology
Authors
Emaddin Kidher
Zhuo Cheng
Omar A Jarral
Declan P O’Regan
Xiao Yun Xu
Thanos Athanasiou
Publication date
01-12-2014
Publisher
BioMed Central
Published in
Journal of Cardiothoracic Surgery / Issue 1/2014
Electronic ISSN: 1749-8090
DOI
https://doi.org/10.1186/s13019-014-0193-6

Other articles of this Issue 1/2014

Journal of Cardiothoracic Surgery 1/2014 Go to the issue