Abstract

Background

Minimal invasive screw fixation is common for treating posterior pelvic ring pathologies, but lack of bone quality may cause anchorage problems. The aim of this study was to report in detail a new technique combining iliosacral screw fixation with in-screw cement augmentation (ISFICA).

Description of technique

The patient was put under general anesthesia and placed in the supine position. A K-wire was inserted under inlet–outlet view to guide the fully threaded screw. The screw placement followed in adequate position. Cement was applied through a bone filler device, inserted at the screwdriver. The immediate control of cement distribution, accurate screw placement and potential leakage were obtained via intraoperative CT scan.

Patients and methods

Twenty consecutive patients treated with ISFICA were included in this study. The mean age was 74.4 years (range 48–98). Screw placement, possible cement leakage and screw positioning were evaluated via intraoperative CT scan. Postoperative neurologic deficits, pain reduction and immediate postoperative mobilization were clinically evaluated.

Results

Twenty-six screws were implanted. All patients were postoperatively, instantly mobilized with reduced pain. No neurologic deficits were apparent postoperatively. No cement leakage occurred. One breach of the iliac cortical bone was noted due to severe osteoporosis.
One screw migration was seen after 1 year and two patients showed iliosacral joint arthropathy, which led to screw removal.

Conclusion

ISFICA is a very promising technique in terms of safety, precision and initial postoperative outcome. Long-term outcomes such as lasting mechanical stability or pain reduction and screw loosening despite cement augmentation should be investigated in further studies with larger patient numbers.
Literature
1.
go back to reference Osterhoff G, Ossendorf C, Wanner GA, Simmen H-P, Werner CML. Percutaneous iliosacral screw fixation in S1 and S2 for posterior pelvic ring injuries: technique and perioperative complications. Arch Orthop Trauma Surg. 2011;131:809–13. http://www.ncbi.nlm.nih.gov/pubmed/21188399. Accessed 22 Nov 2014. Osterhoff G, Ossendorf C, Wanner GA, Simmen H-P, Werner CML. Percutaneous iliosacral screw fixation in S1 and S2 for posterior pelvic ring injuries: technique and perioperative complications. Arch Orthop Trauma Surg. 2011;131:809–13. http://​www.​ncbi.​nlm.​nih.​gov/​pubmed/​21188399. Accessed 22 Nov 2014.
10.
go back to reference Kortman K, Ortiz O, Miller T, Brook A, Tutton S, Mathis J, et al. Multicenter study to assess the efficacy and safety of sacroplasty in patients with osteoporotic sacral insufficiency fractures or pathologic sacral lesions. J Neurointerv Surg. 2013;5:461–6. http://www.ncbi.nlm.nih.gov/pubmed/22684691. Accessed 22 Nov 2014. Kortman K, Ortiz O, Miller T, Brook A, Tutton S, Mathis J, et al. Multicenter study to assess the efficacy and safety of sacroplasty in patients with osteoporotic sacral insufficiency fractures or pathologic sacral lesions. J Neurointerv Surg. 2013;5:461–6. http://​www.​ncbi.​nlm.​nih.​gov/​pubmed/​22684691. Accessed 22 Nov 2014.
15.
go back to reference Gardner MJ, Routt MLC. Transiliac–transsacral screws for posterior pelvic stabilization. J Orthop Trauma. 2011;25:378–84.CrossRefPubMed Gardner MJ, Routt MLC. Transiliac–transsacral screws for posterior pelvic stabilization. J Orthop Trauma. 2011;25:378–84.CrossRefPubMed
16.
20.
go back to reference Zheng Z, Zhang K, Zhang J, Yu B, Liu H, Zhuang X. The effect of screw length and bone cement augmentation on the fixation strength of iliac screws. J Spinal Disord Tech. 2009;22:545–50.CrossRefPubMed Zheng Z, Zhang K, Zhang J, Yu B, Liu H, Zhuang X. The effect of screw length and bone cement augmentation on the fixation strength of iliac screws. J Spinal Disord Tech. 2009;22:545–50.CrossRefPubMed
23.
24.
go back to reference Trumm CG, Rubenbauer B, Piltz S, Reiser MF, Hoffmann R-T. Screw placement and osteoplasty under computed tomographic-fluoroscopic guidance in a case of advanced metastatic destruction of the iliosacral joint. Cardiovasc Intervent Radiol. 2011;34 Suppl 2:S288–93. http://www.ncbi.nlm.nih.gov/pubmed/19795167. Accessed 22 Nov 2014. Trumm CG, Rubenbauer B, Piltz S, Reiser MF, Hoffmann R-T. Screw placement and osteoplasty under computed tomographic-fluoroscopic guidance in a case of advanced metastatic destruction of the iliosacral joint. Cardiovasc Intervent Radiol. 2011;34 Suppl 2:S288–93. http://​www.​ncbi.​nlm.​nih.​gov/​pubmed/​19795167. Accessed 22 Nov 2014.
28.
go back to reference Zwingmann J, Konrad G, Mehlhorn a T, Südkamp NP, Oberst M. Percutaneous iliosacral screw insertion: malpositioning and revision rate of screws with regards to application technique (navigated vs. conventional). J Trauma. 2010;69:1501–6. http://www.ncbi.nlm.nih.gov/pubmed/20526214. Accessed 22 Nov 2014. Zwingmann J, Konrad G, Mehlhorn a T, Südkamp NP, Oberst M. Percutaneous iliosacral screw insertion: malpositioning and revision rate of screws with regards to application technique (navigated vs. conventional). J Trauma. 2010;69:1501–6. http://​www.​ncbi.​nlm.​nih.​gov/​pubmed/​20526214. Accessed 22 Nov 2014.
29.
go back to reference Zwingmann J, Hauschild O, Bode G, Südkamp NP, Schmal H. Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis. Arch Orthop Trauma Surg. 2013;133:1257–65. http://www.ncbi.nlm.nih.gov/pubmed/23748798. Accessed 22 Nov 2014. Zwingmann J, Hauschild O, Bode G, Südkamp NP, Schmal H. Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis. Arch Orthop Trauma Surg. 2013;133:1257–65. http://​www.​ncbi.​nlm.​nih.​gov/​pubmed/​23748798. Accessed 22 Nov 2014.
Metadata
Title
In-screw cement augmentation for iliosacral screw fixation in posterior ring pathologies with insufficient bone stock
Authors
M. A. König
S. Hediger
J. W. Schmitt
T. Jentzsch
K. Sprengel
C. M. L. Werner
Publication date
01-04-2018
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Trauma and Emergency Surgery / Issue 2/2018
Print ISSN: 1863-9933
Electronic ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-016-0681-6

Other articles of this Issue 2/2018

European Journal of Trauma and Emergency Surgery 2/2018 Go to the issue