Abstract

Background

The purpose of this study was to assess the extent to which a supplemental radiographic view increases accuracy and confidence ratings when determining screw placement in volar plating of distal radius fractures for evaluators of different specialties and experience levels.

Methods

Thirty-four distal radius fractures treated with volar plate fixation were imaged using standard AP and lateral, and supplemental lateral tilt views. Each case was then evaluated for penetration of distal screw tips into the articular space. Sixty-five physicians then completed a two-phase analysis and survey of these cases. In the first phase, presentation consisted only of AP and lateral views; in the second, the lateral tilt view was added. Participants were asked to determine whether distal screws penetrated the joint and rate their confidence in the determination. Assessments were scored for correctness; changes in accuracy and confidence levels between phases were analyzed using paired t tests. Comparisons between groups were performed by ANOVA.

Results

Supplementation increased accuracy and confidence in all position, specialty, and experience groups. Confidence scores were significantly higher following evaluation of three views versus two views. Residents exhibited the greatest improvements in accuracy and confidence. For first-phase (standard view) assessments, accuracy scores were significantly better for attendings with less than 10 years post-fellowship experience than those with more.

Conclusions

A supplemental view of the distal radius combined with AP and lateral views significantly improves the ability of all evaluators, regardless of specialty or training level, to correctly assess placement of fixation screws. The greatest improvements are seen for resident trainees.
Literature
1.
go back to reference Boyer MI, Korcek KJ, Gelberman RH, et al. Anatomic tilt x-rays of the distal radius: an ex vivo analysis of surgical fixation. J Hand Surg Am. 2004;29(1):116–22.PubMedCrossRef Boyer MI, Korcek KJ, Gelberman RH, et al. Anatomic tilt x-rays of the distal radius: an ex vivo analysis of surgical fixation. J Hand Surg Am. 2004;29(1):116–22.PubMedCrossRef
2.
go back to reference Gyuricza C, Carlson MG, Weiland AJ, et al. Removal of locked volar plates after distal radius fractures. J Hand Surg Am. 2011;36(6):982–5.PubMedCrossRef Gyuricza C, Carlson MG, Weiland AJ, et al. Removal of locked volar plates after distal radius fractures. J Hand Surg Am. 2011;36(6):982–5.PubMedCrossRef
3.
go back to reference Koval KJ, Harrast JJ, Anglen JO, et al. Fractures of the distal part of the radius. The evolution of practice over time. Where's the evidence? J Bone Joint Surg. 2008;90(9):1855–61.PubMedCrossRef Koval KJ, Harrast JJ, Anglen JO, et al. Fractures of the distal part of the radius. The evolution of practice over time. Where's the evidence? J Bone Joint Surg. 2008;90(9):1855–61.PubMedCrossRef
4.
go back to reference Lutsky K, Boyer MI, Steffen JA, et al. Arthroscopic assessment of intra-articular distal radius fractures after open reduction and internal fixation from a volar approach. J Hand Surg Am. 2008;33(4):476–84.PubMedCrossRef Lutsky K, Boyer MI, Steffen JA, et al. Arthroscopic assessment of intra-articular distal radius fractures after open reduction and internal fixation from a volar approach. J Hand Surg Am. 2008;33(4):476–84.PubMedCrossRef
5.
go back to reference MaschkeSD EPJ, Schub D, et al. Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study. Hand. 2007;2(3):144–50.CrossRef MaschkeSD EPJ, Schub D, et al. Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study. Hand. 2007;2(3):144–50.CrossRef
6.
go back to reference Matullo KS, Dennison DG. Lateral tilt wrist radiograph using the contralateral hand to position the wrist after volar plating of distal radius fractures. J Hand Surg Am. 2010;35(6):900–4.PubMedCrossRef Matullo KS, Dennison DG. Lateral tilt wrist radiograph using the contralateral hand to position the wrist after volar plating of distal radius fractures. J Hand Surg Am. 2010;35(6):900–4.PubMedCrossRef
7.
go back to reference Ozer K, Wolf JM, Watkins B, et al. Comparison of 4 fluoroscopic views for dorsal cortex screw penetration after volar plating of the distal radius. J Hand Surg Am. 2012;37(5):963–7.PubMedCrossRef Ozer K, Wolf JM, Watkins B, et al. Comparison of 4 fluoroscopic views for dorsal cortex screw penetration after volar plating of the distal radius. J Hand Surg Am. 2012;37(5):963–7.PubMedCrossRef
8.
go back to reference Pace A, Cresswell T. Use of articular wrist views to assess intra-articular screw penetration in surgical fixation of distal radius fractures. J Hand Surg Am. 2010;35(6):1015–8.PubMedCrossRef Pace A, Cresswell T. Use of articular wrist views to assess intra-articular screw penetration in surgical fixation of distal radius fractures. J Hand Surg Am. 2010;35(6):1015–8.PubMedCrossRef
9.
go back to reference Smith DW, Henry MH. The 45 pronated oblique view for volar fixed-angle plating of distal radius fractures. J Hand Surg Am. 2004;29(4):703–6.PubMedCrossRef Smith DW, Henry MH. The 45 pronated oblique view for volar fixed-angle plating of distal radius fractures. J Hand Surg Am. 2004;29(4):703–6.PubMedCrossRef
10.
go back to reference Soong M, Got C, Katarincic J, et al. Fluoroscopic evaluation of intra-articular screw placement during locked volar plating of the distal radius: a cadaveric study. J Hand Surg Am. 2008;33(10):1720–3.PubMedCrossRef Soong M, Got C, Katarincic J, et al. Fluoroscopic evaluation of intra-articular screw placement during locked volar plating of the distal radius: a cadaveric study. J Hand Surg Am. 2008;33(10):1720–3.PubMedCrossRef
11.
go back to reference Tweet ML, Calfee RP, Stern PJ. Rotational fluoroscopy assists in detection of intra-articular screw penetration during volar plating of the distal radius. J Hand Surg Am. 2010;35(4):619–27.PubMedCrossRef Tweet ML, Calfee RP, Stern PJ. Rotational fluoroscopy assists in detection of intra-articular screw penetration during volar plating of the distal radius. J Hand Surg Am. 2010;35(4):619–27.PubMedCrossRef
Metadata
Title
Improving accuracy and confidence in distal radius volar plate screw placement through supplemental radiography: examining specialty, education, and experience levels
Authors
Archit Patel
Maya Deza Culbertson
Philip Lahey
Michael Semenovski
Jack Choueka
Publication date
01-09-2013
Publisher
Springer US
Published in
HAND / Issue 3/2013
Print ISSN: 1558-9447
Electronic ISSN: 1558-9455
DOI
https://doi.org/10.1007/s11552-013-9528-3

Other articles of this Issue 3/2013

HAND 3/2013 Go to the issue