Skip to main content
Top
Published in: CardioVascular and Interventional Radiology 1/2013

01-02-2013 | Laboratory Investigation

Improvement of Stent Retriever Design and Efficacy of Mechanical Thrombectomy in a Flow Model

Authors: Katharina Wenger, Frank Nagl, Marlies Wagner, Joachim Berkefeld

Published in: CardioVascular and Interventional Radiology | Issue 1/2013

Login to get access

Abstract

Purpose

In vitro experiments were performed to evaluate the efficacy of mechanical intracranial thrombectomy comparing the newly developed Aperio stent retriever and standard devices for stroke treatment.

Methods

The Aperio (A), with an increased working length of 4 cm and a special cell design for capturing and withholding clots, was compared to three benchmark devices: the Solitaire retrievable stent (B), the Merci X6 (C), and the Merci L5 retriever (D). In a vascular glass model with pulsatile flow, reminiscent of the M1 segment of the middle cerebral artery, we repeatedly induced occlusion by generating thrombi via a modified Chandler loop system. The numbers of recanalization attempts, peripheral embolizations, and recanalizations at the site of occlusion were recorded during 10 retrieval experiments with each device.

Results

Eleven devices were able to remove the blood clots from the occluded branch. In 34 of 40 experiments, restoration of flow was obtained in 1–3 attempts. The main differences between the study devices were observed in terms of clot withholding and fragmentation during retrieval. Although there was only one fragmentation recorded for device A, disengagement of the whole clot or peripheral embolization of fragments occurred more frequently (5–7 times) with devices B, C, and D.

Conclusion

In a vascular model, the design of device A was best at capturing and withholding thrombi during retrieval. Further study will be necessary to see whether this holds true in clinical applications.
Appendix
Available only for authorised users
Literature
1.
go back to reference Bhatia R, Hill MD, Shobha N et al (2010) Low rates of acute recanalization with intravenous recombinant tissue plasminogen activator in ischemic stroke: real-world experience and a call for action. Stroke 41:2254–2258PubMedCrossRef Bhatia R, Hill MD, Shobha N et al (2010) Low rates of acute recanalization with intravenous recombinant tissue plasminogen activator in ischemic stroke: real-world experience and a call for action. Stroke 41:2254–2258PubMedCrossRef
2.
go back to reference Smith WS, Sung G, Saver J et al (2008) Mechanical thrombectomy for acute ischemic stroke: final results of the Multi MERCI trial. Stroke 39:1205–1212PubMedCrossRef Smith WS, Sung G, Saver J et al (2008) Mechanical thrombectomy for acute ischemic stroke: final results of the Multi MERCI trial. Stroke 39:1205–1212PubMedCrossRef
3.
go back to reference Kulcsar Z, Bonvin C, Pereira VM et al (2010) Penumbra system: a novel mechanical thrombectomy device for large-vessel occlusions in acute stroke. Am J Neuroradiol 31:628–633PubMedCrossRef Kulcsar Z, Bonvin C, Pereira VM et al (2010) Penumbra system: a novel mechanical thrombectomy device for large-vessel occlusions in acute stroke. Am J Neuroradiol 31:628–633PubMedCrossRef
4.
go back to reference Becktepe JS, You SJ, Berkefeld J et al (2011) Clinical outcome after mechanical recanalization as mono- or adjunctive therapy in acute stroke: importance of time to recanalization. Cerebrovasc Dis 32:211–218PubMedCrossRef Becktepe JS, You SJ, Berkefeld J et al (2011) Clinical outcome after mechanical recanalization as mono- or adjunctive therapy in acute stroke: importance of time to recanalization. Cerebrovasc Dis 32:211–218PubMedCrossRef
5.
go back to reference Roth C, Papanagiotou P, Behnke S et al (2010) Stent-assisted mechanical recanalization for treatment of acute intracerebral artery occlusions. Stroke 41:2559–2567PubMedCrossRef Roth C, Papanagiotou P, Behnke S et al (2010) Stent-assisted mechanical recanalization for treatment of acute intracerebral artery occlusions. Stroke 41:2559–2567PubMedCrossRef
6.
go back to reference Fesl G, Patzig M, Holtmannspoetter M et al. (2011) Endovascular mechanical recanalisation after intravenous thrombolysis in acute anterior circulation stroke: the impact of a new temporary stent. Cardiovasc Interv Radiol. doi:10.1007/s00270-011-0317-5 Fesl G, Patzig M, Holtmannspoetter M et al. (2011) Endovascular mechanical recanalisation after intravenous thrombolysis in acute anterior circulation stroke: the impact of a new temporary stent. Cardiovasc Interv Radiol. doi:10.​1007/​s00270-011-0317-5
7.
go back to reference Castaño C, Dorado L, Guerrero C et al (2010) Mechanical thrombectomy with the Solitaire AB device in large artery occlusions of the anterior circulation: a pilot study. Stroke 41:1836–1840PubMedCrossRef Castaño C, Dorado L, Guerrero C et al (2010) Mechanical thrombectomy with the Solitaire AB device in large artery occlusions of the anterior circulation: a pilot study. Stroke 41:1836–1840PubMedCrossRef
8.
go back to reference Machi P, Costalat V, Lobotesis K et al (2012) Solitaire FR thrombectomy system: immediate results in 56 consecutive acute ischemic stroke patients. J Neurointerv Surg 4:62–66PubMedCrossRef Machi P, Costalat V, Lobotesis K et al (2012) Solitaire FR thrombectomy system: immediate results in 56 consecutive acute ischemic stroke patients. J Neurointerv Surg 4:62–66PubMedCrossRef
9.
go back to reference Loh Y, Jahan R, McArthur DL (2010) Recanalization rates decrease with increasing thrombectomy attempts. AJNR Am J Neuroradiol 31:935–939PubMedCrossRef Loh Y, Jahan R, McArthur DL (2010) Recanalization rates decrease with increasing thrombectomy attempts. AJNR Am J Neuroradiol 31:935–939PubMedCrossRef
10.
go back to reference Schreiber SJ, Gottschalk S, Weih M et al (2000) Assessment of blood flow velocity and diameter of the middle cerebral artery during the acetazolamide provocation test by use of transcranial doppler sonography and MR imaging. AJNR Am J Neuroradiol 21:1207–1211PubMed Schreiber SJ, Gottschalk S, Weih M et al (2000) Assessment of blood flow velocity and diameter of the middle cerebral artery during the acetazolamide provocation test by use of transcranial doppler sonography and MR imaging. AJNR Am J Neuroradiol 21:1207–1211PubMed
11.
go back to reference Robbie LA, Young SP, Bennett B, Booth NA (1997) Thrombi formed in a Chandler loop mimic human arterial thrombi in structure and RAI-1 content and distribution. Thromb Haemost 77:510–515PubMed Robbie LA, Young SP, Bennett B, Booth NA (1997) Thrombi formed in a Chandler loop mimic human arterial thrombi in structure and RAI-1 content and distribution. Thromb Haemost 77:510–515PubMed
12.
go back to reference Poole CF (1959) A study of artificial thrombi produced by a modification of Chandler’s method. Q J Exp Physiol Cogn Med Sci 44:377–384PubMed Poole CF (1959) A study of artificial thrombi produced by a modification of Chandler’s method. Q J Exp Physiol Cogn Med Sci 44:377–384PubMed
13.
go back to reference Liebig T, Reinartz J, Hannes R (2008) Comparative in vitro study of five mechanical embolectomy systems: effectiveness of clot removal and risk of distal embolization. Neuroradiology 50:43–52PubMedCrossRef Liebig T, Reinartz J, Hannes R (2008) Comparative in vitro study of five mechanical embolectomy systems: effectiveness of clot removal and risk of distal embolization. Neuroradiology 50:43–52PubMedCrossRef
14.
go back to reference Mordasini P, Frabetti N, Gralla J (2011) In vivo evaluation of the first dedicated combined flow-restoration and mechanical thrombectomy device in a swine model of acute vessel occlusion. AJNR Am J Neuroradiol 32:294–300PubMedCrossRef Mordasini P, Frabetti N, Gralla J (2011) In vivo evaluation of the first dedicated combined flow-restoration and mechanical thrombectomy device in a swine model of acute vessel occlusion. AJNR Am J Neuroradiol 32:294–300PubMedCrossRef
Metadata
Title
Improvement of Stent Retriever Design and Efficacy of Mechanical Thrombectomy in a Flow Model
Authors
Katharina Wenger
Frank Nagl
Marlies Wagner
Joachim Berkefeld
Publication date
01-02-2013
Publisher
Springer-Verlag
Published in
CardioVascular and Interventional Radiology / Issue 1/2013
Print ISSN: 0174-1551
Electronic ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-012-0420-2

Other articles of this Issue 1/2013

CardioVascular and Interventional Radiology 1/2013 Go to the issue