Skip to main content
Top
Published in: Journal of Digital Imaging 4/2007

01-12-2007

Implementing Cost-effective 3-Dimensional Ultrasound Using Visual Probe Localization

Authors: Aziah Ali, Rajasvaran Logeswaran

Published in: Journal of Imaging Informatics in Medicine | Issue 4/2007

Login to get access

Abstract

This article proposes a set-up for a 3-dimensional ultrasound system using visual probe localization on the conventional 2-dimensional ultrasound machines readily available in most hospitals. A calibrated digital camera is used for probe-tracking (localization) purposes, whereas ultrasound probe calibration is implemented using a purpose-built phantom. The calibration steps and results are detailed here. The overall system is proven effective in clinical trials through scanning of human organs. Results obtained show successful, accurate 3-dimensional representations using this simple cost-effective set-up.
Literature
1.
go back to reference Prager, RW, Rohling, RN, Gee, AH, Berman, L 1999STRADX: Real-time acquisition and visualization of freehand 3D ultrasoundMed Image Anal3129140PubMedCrossRef Prager, RW, Rohling, RN, Gee, AH, Berman, L 1999STRADX: Real-time acquisition and visualization of freehand 3D ultrasoundMed Image Anal3129140PubMedCrossRef
2.
go back to reference Prager, RW, Rohling, RN, Gee, AH, Berman, L 1998Rapid calibration for 3-D free-hand ultrasoundUltrasound Med Biol24869885CrossRef Prager, RW, Rohling, RN, Gee, AH, Berman, L 1998Rapid calibration for 3-D free-hand ultrasoundUltrasound Med Biol24869885CrossRef
3.
go back to reference Rosseau F, Hellier P, Barillot C: Robust and automatic calibration method for 3D freehand ultrasound. Proceedings of MICCAI, Montreal, pp. 440–448, November 2003 Rosseau F, Hellier P, Barillot C: Robust and automatic calibration method for 3D freehand ultrasound. Proceedings of MICCAI, Montreal, pp. 440–448, November 2003
4.
go back to reference Hossack JA, Ha JS, Sumanaweera TS: Quantitative, free-hand 3D ultrasound imaging based on a modified 1D transducer array. Proceedings of SPIE 4325:102–112, 2001 Hossack JA, Ha JS, Sumanaweera TS: Quantitative, free-hand 3D ultrasound imaging based on a modified 1D transducer array. Proceedings of SPIE 4325:102–112, 2001
5.
go back to reference Ali, A, Logeswaran, R, Bister, MRM 2004Optimal camera calibration for 3D object trackingWSEAS Trans Comput3262266 Ali, A, Logeswaran, R, Bister, MRM 2004Optimal camera calibration for 3D object trackingWSEAS Trans Comput3262266
7.
go back to reference Zhang, Z 1992A flexible new technique for camera calibrationIEEE Trans Pattern Anal Mach Intell14965980CrossRef Zhang, Z 1992A flexible new technique for camera calibrationIEEE Trans Pattern Anal Mach Intell14965980CrossRef
8.
go back to reference Heikkila J, Silven O: A four-step camera calibration procedure with implicit image correction. IEEE Computer Society Conference on Computer Vision and Pattern Recognition, San Juan, Puerto Rico, pp. 1106–1112, 1997 Heikkila J, Silven O: A four-step camera calibration procedure with implicit image correction. IEEE Computer Society Conference on Computer Vision and Pattern Recognition, San Juan, Puerto Rico, pp. 1106–1112, 1997
9.
go back to reference Ali A, Logeswaran R: Probe calibration for 3D ultrasound reconstruction. Proceedings of ROVISP, Malaysia, pp. 451–454, July 2005 Ali A, Logeswaran R: Probe calibration for 3D ultrasound reconstruction. Proceedings of ROVISP, Malaysia, pp. 451–454, July 2005
Metadata
Title
Implementing Cost-effective 3-Dimensional Ultrasound Using Visual Probe Localization
Authors
Aziah Ali
Rajasvaran Logeswaran
Publication date
01-12-2007
Publisher
Springer-Verlag
Published in
Journal of Imaging Informatics in Medicine / Issue 4/2007
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-006-0624-6

Other articles of this Issue 4/2007

Journal of Digital Imaging 4/2007 Go to the issue