Skip to main content
Top
Published in: Journal of Cardiothoracic Surgery 1/2023

Open Access 01-12-2023 | Implantable Cardioverter Defibrillator | Case Report

Successful echocardiography-guided medical management of severe early post-implant right ventricular failure in a patient with left ventricular assist device support: a case report

Authors: Shingo Kunioka, Osamu Seguchi, Tasuku Hada, Hiroki Mochizuki, Masaya Shimojima, Takuya Watanabe, Yasumasa Tsukamoto, Naoki Tadokoro, Satoshi Kainuma, Satsuki Fukushima, Tomoyuki Fujita, Hiroyuki Kamiya, Norihide Fukushima

Published in: Journal of Cardiothoracic Surgery | Issue 1/2023

Login to get access

Abstract

Background

Post-implant right heart failure (RHF) has been recognized as a crucial prognostic factor in patients receiving left ventricular assist devices (LVADs), and its management has long attracted attention from cardiologists and surgeons.

Case presentation

This report described an 18-year-old female with acutely deteriorating heart failure due to dilated cardiomyopathy who underwent paracorporeal pulsatile-flow LVAD and developed early post-implant RHF. At postoperative day (POD) six, she was almost asymptomatic at rest on 2.5 mg/kg/min of dobutamine; however, the echocardiogram, performed as part of the daily postoperative care, revealed a severely enlarged right ventricle with a decompressed left ventricle, implying the development of post-implant RHF. Bolus infusion of saline and reduction of pump flow (6.0 L/min to 3.0 L/min) led to normalization of both ventricular shapes in 30 s, suggesting that RHF could be managed without surgical interventions. Milrinone was started on POD six, followed by sildenafil administration on POD seven. Fluid balance was strictly adjusted under the close observation of daily echocardiograms. Milrinone and dobutamine were discontinued on PODs 18 and 21, respectively. The patient was listed for a heart transplant on POD 40. Despite reduced right ventricular function (right ventricular stroke work index of 182.34 mmHg*ml/m− 2, body surface area 1.5 m2), she was successfully converted to implantable LVAD on POD 44 with no recurrence of post-implant RHF thereafter for four years.

Conclusions

In post-implant RHF management, early detection, together with proper and prompt medical management, is crucial to avoiding any surgical intervention. Close observation of daily echocardiograms might be helpful in detecting subclinical RHF and is useful for post-implant medical management.
Appendix
Available only for authorised users
Literature
1.
go back to reference Kormos RL, Antonides CFJ, Goldstein DJ, Cowger JA, Starling RC, Kirklin JK, Rame JE, Rosenthal D, Mooney ML, Caliskan K, Messe SR, Teuteberg JJ, Mohacsi P, Slaughter MS, Potapov EV, Rao V, Schima H, Stehlik J, Joseph S, Koenig SC, Pagani FD. Updated definitions of adverse events for trials and registries of mechanical circulatory support: a consensus statement of the mechanical circulatory support academic research consortium. J Heart Lung Transplant. 2020;39:735–50.CrossRefPubMed Kormos RL, Antonides CFJ, Goldstein DJ, Cowger JA, Starling RC, Kirklin JK, Rame JE, Rosenthal D, Mooney ML, Caliskan K, Messe SR, Teuteberg JJ, Mohacsi P, Slaughter MS, Potapov EV, Rao V, Schima H, Stehlik J, Joseph S, Koenig SC, Pagani FD. Updated definitions of adverse events for trials and registries of mechanical circulatory support: a consensus statement of the mechanical circulatory support academic research consortium. J Heart Lung Transplant. 2020;39:735–50.CrossRefPubMed
2.
go back to reference Meineri M, Van Rensburg AE, Vegas A. Right ventricular failure after LVAD implantation: prevention and treatment. Best Pract Res Clin Anaesthesiol. 2012;26:217–29.CrossRefPubMed Meineri M, Van Rensburg AE, Vegas A. Right ventricular failure after LVAD implantation: prevention and treatment. Best Pract Res Clin Anaesthesiol. 2012;26:217–29.CrossRefPubMed
3.
go back to reference Baumwol J, Macdonald PS, Keogh AM, Kotlyar E, Spratt P, Jansz P, Hayward CS. Right heart failure and failure to thrive after left ventricular assist device: clinical predictors and outcomes. J Heart Lung Transplant. 2011;30:888–95.PubMed Baumwol J, Macdonald PS, Keogh AM, Kotlyar E, Spratt P, Jansz P, Hayward CS. Right heart failure and failure to thrive after left ventricular assist device: clinical predictors and outcomes. J Heart Lung Transplant. 2011;30:888–95.PubMed
4.
go back to reference Matthews JC, Koelling TM, Pagani FD, Aaronson KD. The right ventricular failure risk score a pre-operative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates. J Am Coll Cardiol. 2008;51:2163–72.CrossRefPubMedPubMedCentral Matthews JC, Koelling TM, Pagani FD, Aaronson KD. The right ventricular failure risk score a pre-operative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates. J Am Coll Cardiol. 2008;51:2163–72.CrossRefPubMedPubMedCentral
5.
go back to reference Kormos RL, Teuteberg JJ, Pagani FD, Russell SD, John R, Miller LW, Massey T, Milano CA, Moazami N, Sundareswaran KS, Farrar DJ. HeartMate II clinical investigators. Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes. J Thorac Cardiovasc Surg. 2010;139:1316–24.CrossRefPubMed Kormos RL, Teuteberg JJ, Pagani FD, Russell SD, John R, Miller LW, Massey T, Milano CA, Moazami N, Sundareswaran KS, Farrar DJ. HeartMate II clinical investigators. Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes. J Thorac Cardiovasc Surg. 2010;139:1316–24.CrossRefPubMed
6.
go back to reference Fitzpatrick JR 3rd, Frederick JR, Hiesinger W, Hsu VM, McCormick RC, Kozin ED, Laporte CM, O’Hara ML, Howell E, Dougherty D, Cohen JE, Southerland KW, Howard JL, Paulson EC, Acker MA, Morris RJ, Woo YJ. Early planned institution of biventricular mechanical circulatory support results in improved outcomes compared with delayed conversion of a left ventricular assist device to a biventricular assist device. J Thorac Cardiovasc Surg. 2009;137:971–7.CrossRefPubMedPubMedCentral Fitzpatrick JR 3rd, Frederick JR, Hiesinger W, Hsu VM, McCormick RC, Kozin ED, Laporte CM, O’Hara ML, Howell E, Dougherty D, Cohen JE, Southerland KW, Howard JL, Paulson EC, Acker MA, Morris RJ, Woo YJ. Early planned institution of biventricular mechanical circulatory support results in improved outcomes compared with delayed conversion of a left ventricular assist device to a biventricular assist device. J Thorac Cardiovasc Surg. 2009;137:971–7.CrossRefPubMedPubMedCentral
7.
go back to reference Patel ND, Weiss ES, Schaffer J, Ullrich SL, Rivard DC, Shah AS, Russell SD, Conte JVPatel ND, Weiss ES, Schaffer J, Ullrich SL, Rivard DC, Shah AS, Russell SD, Conte JV. Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices. Ann Thorac Surg. 2008;86:832–40. discussion 832–40.CrossRefPubMed Patel ND, Weiss ES, Schaffer J, Ullrich SL, Rivard DC, Shah AS, Russell SD, Conte JVPatel ND, Weiss ES, Schaffer J, Ullrich SL, Rivard DC, Shah AS, Russell SD, Conte JV. Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices. Ann Thorac Surg. 2008;86:832–40. discussion 832–40.CrossRefPubMed
8.
go back to reference Morine KJ, Kiernan MS, Pham DT, Paruchuri V, Denofrio D, Kapur NK. Pulmonary artery pulsatility index is associated with right ventricular failure after left ventricular assist device surgery. J Card Fail. 2016;22:110–6.CrossRefPubMed Morine KJ, Kiernan MS, Pham DT, Paruchuri V, Denofrio D, Kapur NK. Pulmonary artery pulsatility index is associated with right ventricular failure after left ventricular assist device surgery. J Card Fail. 2016;22:110–6.CrossRefPubMed
9.
go back to reference Deng MC, Edwards LB, Hertz MI, Rowe AW, Keck BM, Kormos R, Naftel DC, Kirklin JK, Taylor DO. International Society for Heart and Lung Transplantation. Mechanical circulatory support device database of the International Society for Heart and Lung Transplantation: third annual report–2005. J Heart Lung Transplant 2005;24:1182–7. Deng MC, Edwards LB, Hertz MI, Rowe AW, Keck BM, Kormos R, Naftel DC, Kirklin JK, Taylor DO. International Society for Heart and Lung Transplantation. Mechanical circulatory support device database of the International Society for Heart and Lung Transplantation: third annual report–2005. J Heart Lung Transplant 2005;24:1182–7.
10.
go back to reference Takeda K, Naka Y, Yang JA, Uriel N, Colombo PC, Jorde UP, Takayama H. Timing of temporary right ventricular assist device insertion for severe right heart failure after left ventricular assist device implantation. ASAIO J. 2013;59:564–9.CrossRefPubMed Takeda K, Naka Y, Yang JA, Uriel N, Colombo PC, Jorde UP, Takayama H. Timing of temporary right ventricular assist device insertion for severe right heart failure after left ventricular assist device implantation. ASAIO J. 2013;59:564–9.CrossRefPubMed
11.
go back to reference Farrar DJ, Compton PG, Hershon JJ, Fonger JD, Hill JD. Right heart interaction with the mechanically assisted left heart. World J Surg. 1985;9:89–102.CrossRefPubMed Farrar DJ, Compton PG, Hershon JJ, Fonger JD, Hill JD. Right heart interaction with the mechanically assisted left heart. World J Surg. 1985;9:89–102.CrossRefPubMed
12.
go back to reference Moon MR, Bolger AF, DeAnda A, Komeda M, Daughters GT 2nd, Nikolic SD, Miller DC, Ingels NB Jr. Septal function during left ventricular unloading. Circulation. 1997;95:1320–7.CrossRefPubMed Moon MR, Bolger AF, DeAnda A, Komeda M, Daughters GT 2nd, Nikolic SD, Miller DC, Ingels NB Jr. Septal function during left ventricular unloading. Circulation. 1997;95:1320–7.CrossRefPubMed
13.
go back to reference Topilsky Y, Hasin T, Oh JK, Borgeson DD, Boilson BA, Schirger JA, Clavell AL, Frantz RP, Tsutsui R, Liu M, Maltais S, Kushwaha SS, Pereira NL, Park SJ. Echocardiographic variables after left ventricular assist device implantation associated with adverse outcome. Circ Cardiovasc Imaging. 2011;4:648–61.CrossRefPubMed Topilsky Y, Hasin T, Oh JK, Borgeson DD, Boilson BA, Schirger JA, Clavell AL, Frantz RP, Tsutsui R, Liu M, Maltais S, Kushwaha SS, Pereira NL, Park SJ. Echocardiographic variables after left ventricular assist device implantation associated with adverse outcome. Circ Cardiovasc Imaging. 2011;4:648–61.CrossRefPubMed
14.
go back to reference Sack KL, Dabiri Y, Franz T, Solomon SD, Burkhoff D, Guccione JM. Investigating the role of interventricular interdependence in development of right heart dysfunction during LVAD support: a patient-specific methods-based approach. Front Physiol. 2018;9:520.CrossRefPubMedPubMedCentral Sack KL, Dabiri Y, Franz T, Solomon SD, Burkhoff D, Guccione JM. Investigating the role of interventricular interdependence in development of right heart dysfunction during LVAD support: a patient-specific methods-based approach. Front Physiol. 2018;9:520.CrossRefPubMedPubMedCentral
15.
go back to reference Kimmaliardjuk DM, Ruel M. Cardiac passive-aggressive behavior? The right ventricle in patients with a left ventricular assist device. Expert Rev Cardiovasc Ther. 2017;15:267–76.CrossRefPubMed Kimmaliardjuk DM, Ruel M. Cardiac passive-aggressive behavior? The right ventricle in patients with a left ventricular assist device. Expert Rev Cardiovasc Ther. 2017;15:267–76.CrossRefPubMed
16.
go back to reference Potapov EV, Stepanenko A, Dandel M, Kukucka M, Lehmkuhl HB, Weng Y, Hennig F, Krabatsch T, Hetzer R. Tricuspid incompetence and geometry of the right ventricle as predictors of right ventricular function after implantation of a left ventricular assist device. J Heart Lung Transplant. 2008;27:1275–81.CrossRefPubMed Potapov EV, Stepanenko A, Dandel M, Kukucka M, Lehmkuhl HB, Weng Y, Hennig F, Krabatsch T, Hetzer R. Tricuspid incompetence and geometry of the right ventricle as predictors of right ventricular function after implantation of a left ventricular assist device. J Heart Lung Transplant. 2008;27:1275–81.CrossRefPubMed
17.
Metadata
Title
Successful echocardiography-guided medical management of severe early post-implant right ventricular failure in a patient with left ventricular assist device support: a case report
Authors
Shingo Kunioka
Osamu Seguchi
Tasuku Hada
Hiroki Mochizuki
Masaya Shimojima
Takuya Watanabe
Yasumasa Tsukamoto
Naoki Tadokoro
Satoshi Kainuma
Satsuki Fukushima
Tomoyuki Fujita
Hiroyuki Kamiya
Norihide Fukushima
Publication date
01-12-2023

Other articles of this Issue 1/2023

Journal of Cardiothoracic Surgery 1/2023 Go to the issue