Skip to main content
Top
Published in: World Journal of Urology 11/2017

01-11-2017 | Original Article

Impact of laser fiber tip cleavage on power output for ureteroscopy and stone treatment

Authors: M. Haddad, E. Emiliani, Y. Rouchausse, F. Coste, L. Berthe, S. Doizi, S. Buttice, B. Somani, O. Traxer

Published in: World Journal of Urology | Issue 11/2017

Login to get access

Abstract

Purpose

Holmium:YAG laser is the most used laser for urolithiasis. Generally, we use metallic scissors to cut the fiber tip to restore its effectiveness. Many cleaving methods have been described to avoid fiber damage and to restore its greatest power to the fiber. There is a lack of information regarding which cleaving method should be used and its effect on the fiber. In order to compare these effects, we studied different cleavage methods in terms of power output and its effects on the fiber.

Methods

New single-use 272-μm fibers were used with a holmium:YAG laser lithotripter. Five kinds of fiber tips were compared: a new intact fiber, cleaved with ceramic scissors, cleaved with metallic scissors, first cleaved then stripped and first stripped then cleaved. The fibers were used against synthetic stones (BegoStone®) similar to calcium oxalate monohydrate, with fragmentation (SP, 5 Hz, 1.5 J) and dusting (LP, 15 Hz, 0.5 J) settings. We measured power output at 0, 1, 5, 10 and 15 min.

Results

For fragmentation parameters, there was a statistical difference between the 5 groups at 0 and 1 min of laser use (p < 0.05) and none for time period over 1 min (p = 0.077–0.658). For dusting parameters, there was a statistical difference between the 5 groups at 0 min of laser use (p < 0.05) and none for time period over 0 min (p = 0.064–1).

Conclusion

Cleaving the fiber tip may restore its effectiveness to the fiber, but only for a limited time, although it may preserve the scopes from damage.
Appendix
Available only for authorised users
Literature
1.
go back to reference Kronenberg P, Traxer O (2014) Update on lasers in urology 2014: current assessment on holmium:yttrium-aluminum-garnet (Ho:YAG) laser lithotripter settings and laser fibers. World J Urol 33(4):463–469CrossRefPubMed Kronenberg P, Traxer O (2014) Update on lasers in urology 2014: current assessment on holmium:yttrium-aluminum-garnet (Ho:YAG) laser lithotripter settings and laser fibers. World J Urol 33(4):463–469CrossRefPubMed
2.
go back to reference Vicente Rodríguez J, Fernández González I, Hernández Fernández C, Santos García-Vaquero I, Rosales Bordes A (2006) Lasers in urology. Actas Urol Esp 30(9):879–895CrossRefPubMed Vicente Rodríguez J, Fernández González I, Hernández Fernández C, Santos García-Vaquero I, Rosales Bordes A (2006) Lasers in urology. Actas Urol Esp 30(9):879–895CrossRefPubMed
3.
go back to reference Mues AC, Teichman JMH, Knudsen BE (2009) Quantification of holmium:yttrium aluminum garnet optical tip degradation. J Endourol Endourol Soc 23(9):1425–1428CrossRef Mues AC, Teichman JMH, Knudsen BE (2009) Quantification of holmium:yttrium aluminum garnet optical tip degradation. J Endourol Endourol Soc 23(9):1425–1428CrossRef
4.
go back to reference Khemees TA, Shore DM, Antiporda M, Teichman JMH, Knudsen BE (2013) Evaluation of a new 240-μm single-use holmium:YAG optical fiber for flexible ureteroscopy. J Endourol 27(4):475–479CrossRefPubMed Khemees TA, Shore DM, Antiporda M, Teichman JMH, Knudsen BE (2013) Evaluation of a new 240-μm single-use holmium:YAG optical fiber for flexible ureteroscopy. J Endourol 27(4):475–479CrossRefPubMed
5.
go back to reference Kronenberg P, Traxer O (2015) Are we all doing it wrong? Influence of stripping and cleaving methods of laser fibers on laser lithotripsy performance. J Urol 193(3):1030–1035CrossRefPubMed Kronenberg P, Traxer O (2015) Are we all doing it wrong? Influence of stripping and cleaving methods of laser fibers on laser lithotripsy performance. J Urol 193(3):1030–1035CrossRefPubMed
6.
go back to reference Peplinski B, Faaborg D, Miao E, Alsyouf M, Myklak K, Kelln W et al (2016) The effect of laser fiber cleave technique and lithotripsy time on power output. J Endourol 30(6):678–684CrossRefPubMed Peplinski B, Faaborg D, Miao E, Alsyouf M, Myklak K, Kelln W et al (2016) The effect of laser fiber cleave technique and lithotripsy time on power output. J Endourol 30(6):678–684CrossRefPubMed
7.
go back to reference Esch E, Simmons WN, Sankin G, Cocks HF, Preminger GM, Zhong P (2010) A simple method for fabricating artificial kidney stones of different physical properties. Urol Res 38(4):315–319CrossRefPubMedPubMedCentral Esch E, Simmons WN, Sankin G, Cocks HF, Preminger GM, Zhong P (2010) A simple method for fabricating artificial kidney stones of different physical properties. Urol Res 38(4):315–319CrossRefPubMedPubMedCentral
8.
go back to reference Yunbo Liu PZ (2002) BegoStone—a new stone phantom for shock wave lithotripsy research (L). J Acoust Soc Am 112(4):1265–1268CrossRefPubMed Yunbo Liu PZ (2002) BegoStone—a new stone phantom for shock wave lithotripsy research (L). J Acoust Soc Am 112(4):1265–1268CrossRefPubMed
9.
go back to reference Sea J, Jonat LM, Chew BH, Qiu J, Wang B, Hoopman J et al (2012) Optimal power settings for Holmium:YAG lithotripsy. J Urol 187(3):914–919CrossRefPubMed Sea J, Jonat LM, Chew BH, Qiu J, Wang B, Hoopman J et al (2012) Optimal power settings for Holmium:YAG lithotripsy. J Urol 187(3):914–919CrossRefPubMed
10.
go back to reference Kronenberg P, Traxer O (2014) In vitro fragmentation efficiency of holmium: yttrium-aluminum-garnet (YAG) laser lithotripsy—a comprehensive study encompassing different frequencies, pulse energies, total power levels and laser fibre diameters. BJU Int 114(2):261–267CrossRefPubMed Kronenberg P, Traxer O (2014) In vitro fragmentation efficiency of holmium: yttrium-aluminum-garnet (YAG) laser lithotripsy—a comprehensive study encompassing different frequencies, pulse energies, total power levels and laser fibre diameters. BJU Int 114(2):261–267CrossRefPubMed
11.
go back to reference Giusti G, Proietti S, Villa L, Cloutier J, Rosso M, Gadda GM et al (2016) Current standard technique for modern flexible ureteroscopy: tips and tricks. Eur Urol 70(1):188–194CrossRefPubMed Giusti G, Proietti S, Villa L, Cloutier J, Rosso M, Gadda GM et al (2016) Current standard technique for modern flexible ureteroscopy: tips and tricks. Eur Urol 70(1):188–194CrossRefPubMed
12.
go back to reference Vassantachart JM, Lightfoot M, Yeo A, Maldonado J, Li R, Alsyouf M et al (2015) Laser fiber cleaving techniques: effects on tip morphology and power output. J Endourol Endourol Soc 29(1):84–89CrossRef Vassantachart JM, Lightfoot M, Yeo A, Maldonado J, Li R, Alsyouf M et al (2015) Laser fiber cleaving techniques: effects on tip morphology and power output. J Endourol Endourol Soc 29(1):84–89CrossRef
14.
go back to reference Mues AC, Teichman JMH, Knudsen BE (2009) Evaluation of 24 Holmium:YAG laser optical fibers for flexible ureteroscopy. J Urol 182(1):348–354CrossRefPubMed Mues AC, Teichman JMH, Knudsen BE (2009) Evaluation of 24 Holmium:YAG laser optical fibers for flexible ureteroscopy. J Urol 182(1):348–354CrossRefPubMed
15.
go back to reference Akar EC, Knudsen BE (2015) Evaluation of 16 new holmium: yttrium-aluminum-garnet laser optical fibers for ureteroscopy. Urology 86(2):230–235CrossRefPubMed Akar EC, Knudsen BE (2015) Evaluation of 16 new holmium: yttrium-aluminum-garnet laser optical fibers for ureteroscopy. Urology 86(2):230–235CrossRefPubMed
Metadata
Title
Impact of laser fiber tip cleavage on power output for ureteroscopy and stone treatment
Authors
M. Haddad
E. Emiliani
Y. Rouchausse
F. Coste
L. Berthe
S. Doizi
S. Buttice
B. Somani
O. Traxer
Publication date
01-11-2017
Publisher
Springer Berlin Heidelberg
Published in
World Journal of Urology / Issue 11/2017
Print ISSN: 0724-4983
Electronic ISSN: 1433-8726
DOI
https://doi.org/10.1007/s00345-017-2053-1

Other articles of this Issue 11/2017

World Journal of Urology 11/2017 Go to the issue