Skip to main content
Top
Published in: Graefe's Archive for Clinical and Experimental Ophthalmology 2/2003

01-02-2003 | Laboratory Investigation

Impact of head advance and oscillation rate on the flap parameter: a comparison of two microkeratomes

Authors: Stefanie Hoffmann, Frank Krummenauer, Mana Tehrani, H. Burkhard Dick

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology | Issue 2/2003

Login to get access

Abstract

Purpose.

To compare flap quality and thickness in an experimental setting using the Amadeus and Carriazo/Barraquer microkeratomes.

Methods.

One hundred and sixty-three fresh porcine cadaver eyes were used to cut corneal flaps. One hundred and thirty-five eyes were cut using the Amadeus microkeratome with various settings of head advance and oscillation rate, 28 eyes using the Carriazo/Barraquer microkeratome (Supratome). Flap diameter and hinge width were measured by planimetry and flap thickness by ultrasound pachymetry. Descriptive statistical analysis was based on medians and quartiles, graphical representation on box plots. The measurement devices were compared by two sample Wilcoxon tests, their deviation from the distributors' reference measurement values by sign tests.

Results.

Variation of oscillation rate and head advance led to significant differences in flap thickness. Optimal cut quality was achieved with 1 mm/s head advance and 8,000 rpm in the Amadeus microkeratome. With this setting the smallest target deviations in flap thickness were obtained among the results with lowest range (median 170 µm, interquartile range 18 µm, target 160 µm). The Amadeus microkeratome demonstrated a statistically significant lower deviation from the target thickness (P<0.001) and also a lower range than the Supratome (median 127 µm, interquartile range 30 µm, target 140 µm; P<0.001).

Conclusions.

Optimization of microkeratome settings leads to minimized deviation from target thickness and improved parameter. The Amadeus microkeratome achieved a statistically significant lower deviation in flap thickness than the Carriazo/Barraquer microkeratome. Individualization of the microkeratome settings may help to decrease flap complications and improve refractive outcome.
Literature
1.
go back to reference Ambrosio R Jr, Wilson SE (2001) Complications of laser in situ keratomileusis: etiology, prevention, and treatment. J Refract Surg 17:350–379PubMed Ambrosio R Jr, Wilson SE (2001) Complications of laser in situ keratomileusis: etiology, prevention, and treatment. J Refract Surg 17:350–379PubMed
2.
go back to reference Barraquer JI (1964) Queratomileusis para la correccion de la miopia. Arch Soc Am Oftalmol Optom 5:27–48 Barraquer JI (1964) Queratomileusis para la correccion de la miopia. Arch Soc Am Oftalmol Optom 5:27–48
3.
go back to reference Behrens A, Langenbucher A, Kus MM, et al. (2000) Experimental evaluation of two current-generation automated microkeratomes: the Hansatome and the Supratome. Am J Ophthalmol 129:59–67CrossRefPubMed Behrens A, Langenbucher A, Kus MM, et al. (2000) Experimental evaluation of two current-generation automated microkeratomes: the Hansatome and the Supratome. Am J Ophthalmol 129:59–67CrossRefPubMed
4.
go back to reference Behrens A, Seitz B, Langenbucher A, et al. (2000) Evaluation of corneal flap dimensions and cut quality using the Automated Corneal Shaper microkeratome. J Refract Surg 16:83–89PubMed Behrens A, Seitz B, Langenbucher A, et al. (2000) Evaluation of corneal flap dimensions and cut quality using the Automated Corneal Shaper microkeratome. J Refract Surg 16:83–89PubMed
5.
go back to reference Binder PS, Moore M, Lambert R W, et al. (1997) Comparison of two microkeratome systems. J Refract Surg 13:142–153PubMed Binder PS, Moore M, Lambert R W, et al. (1997) Comparison of two microkeratome systems. J Refract Surg 13:142–153PubMed
6.
go back to reference Cha DW, Ahn BC (1997) Laser in situ keratomileusis to treat low to moderate myopia. J Korean Ophthalmol Soc 38:715–720 Cha DW, Ahn BC (1997) Laser in situ keratomileusis to treat low to moderate myopia. J Korean Ophthalmol Soc 38:715–720
7.
go back to reference De Korte CL, van der Steen A F, Thijssen JM (1994) Acoustic velocity and attenuation of eye tissues at 20 MHz. Ultrasound Med Biol 20:471–480PubMed De Korte CL, van der Steen A F, Thijssen JM (1994) Acoustic velocity and attenuation of eye tissues at 20 MHz. Ultrasound Med Biol 20:471–480PubMed
8.
go back to reference Draeger J, Böhnke M, Klein L, et al (1998) Experimentelle Untersuchungen zur Präzision lamellärer Hornhautschnitte. Fortschr Ophthalmol 272–275 Draeger J, Böhnke M, Klein L, et al (1998) Experimentelle Untersuchungen zur Präzision lamellärer Hornhautschnitte. Fortschr Ophthalmol 272–275
9.
go back to reference Gimbel HV, Peters NT, Iskander NG, et al. (2000) LASIK flap complications and management. J Refract Surg 16:223–225 Gimbel HV, Peters NT, Iskander NG, et al. (2000) LASIK flap complications and management. J Refract Surg 16:223–225
10.
go back to reference Jacobs BJ, Deutsch TA, Rubenstein JB (1999) Reproducibility of corneal flap thickness in LASIK. Ophthalmic Surg Lasers 30:350–353PubMed Jacobs BJ, Deutsch TA, Rubenstein JB (1999) Reproducibility of corneal flap thickness in LASIK. Ophthalmic Surg Lasers 30:350–353PubMed
11.
go back to reference Kim YH, Choi J-S, Chun HJ, et al. (1999) Effect of resection velocity and suction ring on corneal flap formation in laser in situ keratomileusis. J Cataract Refract Surg 25:1448–1455CrossRefPubMed Kim YH, Choi J-S, Chun HJ, et al. (1999) Effect of resection velocity and suction ring on corneal flap formation in laser in situ keratomileusis. J Cataract Refract Surg 25:1448–1455CrossRefPubMed
12.
go back to reference Lin RT, Maloney RK (1999) Flap complications associated with lamellar refractive surgery. Am J Ophthalmol 127:129–136CrossRefPubMed Lin RT, Maloney RK (1999) Flap complications associated with lamellar refractive surgery. Am J Ophthalmol 127:129–136CrossRefPubMed
13.
go back to reference Price FW Jr, Koller DL, Price MO (1999) Central corneal pachymetry in patients undergoing laser in situ keratomileusis. Ophthalmology 106:2216–2220PubMed Price FW Jr, Koller DL, Price MO (1999) Central corneal pachymetry in patients undergoing laser in situ keratomileusis. Ophthalmology 106:2216–2220PubMed
14.
go back to reference Seiler T (2000) In: Seiler T (ed) Refraktive Chirurgie der Hornhaut. Enke im Thieme, Stuttgart, Germany Seiler T (2000) In: Seiler T (ed) Refraktive Chirurgie der Hornhaut. Enke im Thieme, Stuttgart, Germany
15.
go back to reference Walker MB, Wilson SE (2000) Lower intraoperative flap complication rate with the Hansatome microkeratome compared to the Automated Corneal Shaper. J Refract Surg 16:79–82PubMed Walker MB, Wilson SE (2000) Lower intraoperative flap complication rate with the Hansatome microkeratome compared to the Automated Corneal Shaper. J Refract Surg 16:79–82PubMed
16.
go back to reference Wilhelm F W, Giessmann T, Hanschke R, et al (2000) Cut edges and surface characteristics produced by different microkeratomes. J Refract Surg 16:690–700PubMed Wilhelm F W, Giessmann T, Hanschke R, et al (2000) Cut edges and surface characteristics produced by different microkeratomes. J Refract Surg 16:690–700PubMed
17.
go back to reference Wilmes C, Draeger J, Kohlhaas M (1992) Lentikeldickenpräzision in Abhängigkeit von den Gewebeausgangsdicken, experimentelle Ergebnisse mit dem lamellären Mikokeratom. Ophthalmologe 89:147–150PubMed Wilmes C, Draeger J, Kohlhaas M (1992) Lentikeldickenpräzision in Abhängigkeit von den Gewebeausgangsdicken, experimentelle Ergebnisse mit dem lamellären Mikokeratom. Ophthalmologe 89:147–150PubMed
18.
go back to reference Yildirim R, Aras C, Ozdamar A, et al (2000) Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome. J Cataract Refract Surg 26:1729–1732CrossRefPubMed Yildirim R, Aras C, Ozdamar A, et al (2000) Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome. J Cataract Refract Surg 26:1729–1732CrossRefPubMed
Metadata
Title
Impact of head advance and oscillation rate on the flap parameter: a comparison of two microkeratomes
Authors
Stefanie Hoffmann
Frank Krummenauer
Mana Tehrani
H. Burkhard Dick
Publication date
01-02-2003
Publisher
Springer-Verlag
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 2/2003
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-002-0599-z

Other articles of this Issue 2/2003

Graefe's Archive for Clinical and Experimental Ophthalmology 2/2003 Go to the issue