Skip to main content
Top
Published in: HAND 3/2008

01-09-2008 | Original Article

Immersion in Cold-Water Evaluation (ICE) and Self-reported Cold Intolerance are Reliable but Unrelated Measures

Authors: Robyn Traynor, Joy C. MacDermid

Published in: HAND | Issue 3/2008

Login to get access

Abstract

Intolerance to the cold is common following peripheral nerve injury and surgery of the upper extremity. Despite its prevalence, the exact pathophysiology and natural history of this condition are not well understood. Subjective, self-report questionnaires have been created and validated as reliable measures of post-traumatic cold intolerance. The difficulty currently lies in assigning an objective measure to this predominantly subjective phenomenon. The present study evaluated the test–retest reliability of a proposed objective measure of cold intolerance, the Immersion in Cold-water Evaluation (ICE), and its correlation with subjective measures in healthy control subjects. Two age groups were also compared to investigate the effect of age on cold intolerance and temperature recovery. On two separate testing days, subjects completed three health-related questionnaires and submersed their dominant hands in cold water. The temperature of their second and fifth digits was monitored during recovery. Both the objective cold-provocation testing and the subjective self-report questionnaires were highly reliable albeit not significantly correlated. No significant temperature recovery trend was noted between the age groups. Post-traumatic cold intolerance is postulated to have both a vascular and neural etiology among other contributing causes. The protocol studied here was centered predominantly on the former etiology, examining peripheral blood flow and associated temperature recovery. This study established ICE as a reliable means to objectively measure cold response, supplementing information provided by previously validated self-report methods.
Literature
1.
go back to reference Bear MF, Connors BW, Paradiso MA. The somatic sensory system. In Neuroscience: Exploring the Brain, 3rd ed. Philadelphia: Lippincott Williams & Wilkins; 2007. pp. 387–421. Bear MF, Connors BW, Paradiso MA. The somatic sensory system. In Neuroscience: Exploring the Brain, 3rd ed. Philadelphia: Lippincott Williams & Wilkins; 2007. pp. 387–421.
2.
go back to reference Campbell DA, Kay SP. What is cold intolerance. J Hand Surg. 1998;23B(1):3–5. Campbell DA, Kay SP. What is cold intolerance. J Hand Surg. 1998;23B(1):3–5.
3.
go back to reference Collins ED, Novak CB, Mackinnon SE, et al. Long-term follow-up evaluation of cold sensitivity following nerve injury. J Hand Surg 1996;21A:1078–85. Collins ED, Novak CB, Mackinnon SE, et al. Long-term follow-up evaluation of cold sensitivity following nerve injury. J Hand Surg 1996;21A:1078–85.
4.
go back to reference Coughlin PA, Chetter IC, Kent PJ, et al. The analysis of sensitivity, specificity, positive predictive value and negative predictive value of cold provocation thermography in the objective diagnosis of the hand–arm vibration syndrome. Occup Med 2000;51(2):75–80.CrossRef Coughlin PA, Chetter IC, Kent PJ, et al. The analysis of sensitivity, specificity, positive predictive value and negative predictive value of cold provocation thermography in the objective diagnosis of the hand–arm vibration syndrome. Occup Med 2000;51(2):75–80.CrossRef
5.
go back to reference Craigen M, Kleinert JM, Miller Crain G, et al. Patient and injury characteristics in the development of cold sensitvity of the hand: A prospective cohort study. J Hand Surg 1999;24A:8–15. Craigen M, Kleinert JM, Miller Crain G, et al. Patient and injury characteristics in the development of cold sensitvity of the hand: A prospective cohort study. J Hand Surg 1999;24A:8–15.
6.
go back to reference de Medinaceli L, Hurpeau J-C, Merle M, et al. Cold and post-traumatic pain: modeling of the peripheral nerve message. BioSystems 1997;43:145–67.PubMedCrossRef de Medinaceli L, Hurpeau J-C, Merle M, et al. Cold and post-traumatic pain: modeling of the peripheral nerve message. BioSystems 1997;43:145–67.PubMedCrossRef
7.
go back to reference Engkvist O, Wahren LK, Wallin G, et al. Effects of regional intravenous guanethidine block in posttraumatic cold intolerance in hand amputees. J Hand Surg 1985;10B:145–50. Engkvist O, Wahren LK, Wallin G, et al. Effects of regional intravenous guanethidine block in posttraumatic cold intolerance in hand amputees. J Hand Surg 1985;10B:145–50.
8.
go back to reference Feger J, Braune S. Measurement of skin vasoconstrictor response in healthy subjects. Auton Neurosci 2005;120:88–96.PubMedCrossRef Feger J, Braune S. Measurement of skin vasoconstrictor response in healthy subjects. Auton Neurosci 2005;120:88–96.PubMedCrossRef
9.
go back to reference Harris JE, MacDermid JC, Roth J. The International Classification of Functioning as an explanatory model of health after distal radius fracture: A cohort study. Health Qual Life Outcome 2005;3:7381. Harris JE, MacDermid JC, Roth J. The International Classification of Functioning as an explanatory model of health after distal radius fracture: A cohort study. Health Qual Life Outcome 2005;3:7381.
10.
go back to reference Irwin MS, Gilbert SEA, Terenghi G, et al. Cold intolerance following peripheral nerve injury. J Hand Surg 1997;22B(3):308–16. Irwin MS, Gilbert SEA, Terenghi G, et al. Cold intolerance following peripheral nerve injury. J Hand Surg 1997;22B(3):308–16.
11.
go back to reference Ishitake T, Kihara T, Matoba T. A revised cold water immersion test for assessing peripheral circulatory function. Kurume Med J 1996;43(1):11–5.PubMed Ishitake T, Kihara T, Matoba T. A revised cold water immersion test for assessing peripheral circulatory function. Kurume Med J 1996;43(1):11–5.PubMed
12.
go back to reference Klein-Weigel P, Pavelka M, Dabernig J, et al. Macro- and microcirculatory assessment of cold sensitivity after traumatic finger amputation and microsurgical replantation. Arch Orthop Trauma Surg 2007;127(5):355–60.PubMedCrossRef Klein-Weigel P, Pavelka M, Dabernig J, et al. Macro- and microcirculatory assessment of cold sensitivity after traumatic finger amputation and microsurgical replantation. Arch Orthop Trauma Surg 2007;127(5):355–60.PubMedCrossRef
13.
go back to reference Koman LA, Nunley JA, Goldner JL, et al. Isolated cold stress testing in the assessment of symptoms in the upper extremity: Preliminary communication. J Hand Surg 1984;9A:305–13. Koman LA, Nunley JA, Goldner JL, et al. Isolated cold stress testing in the assessment of symptoms in the upper extremity: Preliminary communication. J Hand Surg 1984;9A:305–13.
14.
go back to reference Lithell M, Backman C, Nystrom A. Pattern recognition in post-traumatic cold intolerance. J Hand Surg 1997;22B(6):783–7. Lithell M, Backman C, Nystrom A. Pattern recognition in post-traumatic cold intolerance. J Hand Surg 1997;22B(6):783–7.
15.
go back to reference Lithell M, Backman C, Nystrom A. Cold intolerance is not more common or disabling after digital replantation than after other treatment of compound digital injuries. Ann Plast Surg 1998;40:256–9.PubMedCrossRef Lithell M, Backman C, Nystrom A. Cold intolerance is not more common or disabling after digital replantation than after other treatment of compound digital injuries. Ann Plast Surg 1998;40:256–9.PubMedCrossRef
16.
go back to reference MacDermid JC. Measurement of health outcomes following tendon and nerve repair. J Hand Ther 2005;18:297–312.PubMedCrossRef MacDermid JC. Measurement of health outcomes following tendon and nerve repair. J Hand Ther 2005;18:297–312.PubMedCrossRef
17.
go back to reference Mason HJ, Poole K, Saxton J. A critique of a UK standardized test of finger rewarming after cold provocation in the diagnosis and staging of hand–arm vibration syndrome. Occup Med 2003;53:325–30.CrossRef Mason HJ, Poole K, Saxton J. A critique of a UK standardized test of finger rewarming after cold provocation in the diagnosis and staging of hand–arm vibration syndrome. Occup Med 2003;53:325–30.CrossRef
18.
go back to reference McCabe SJ, Mizgala C, Glickman C. The measurement of cold sensitivity of the hand. J Hand Surg 1991;16A:1037–40. McCabe SJ, Mizgala C, Glickman C. The measurement of cold sensitivity of the hand. J Hand Surg 1991;16A:1037–40.
19.
go back to reference Nancarrow JD, Rai SA, Sterne GD, et al. The natural history of cold intolerance of the hand. Injury 1996;27(9):607–11.PubMedCrossRef Nancarrow JD, Rai SA, Sterne GD, et al. The natural history of cold intolerance of the hand. Injury 1996;27(9):607–11.PubMedCrossRef
20.
go back to reference Nylander G, Nylander E, Lassvik C. Cold sensitivity after replantation in relation to arterial circulation and vasoregulation. J Hand Surg 1987;12B(1):78–81. Nylander G, Nylander E, Lassvik C. Cold sensitivity after replantation in relation to arterial circulation and vasoregulation. J Hand Surg 1987;12B(1):78–81.
22.
go back to reference Patel AA, Donegan D, Albert T. The 36-item short form. J Am Acad Orthop Surg 2007;15(2):126–34.PubMed Patel AA, Donegan D, Albert T. The 36-item short form. J Am Acad Orthop Surg 2007;15(2):126–34.PubMed
23.
go back to reference Pollock FE, Koman LA, Smith BP, et al. Measurement of hand microvascular blood flow with isolated cold stress testing and laser Doppler fluxmetry. J Hand Surg 1993;18(A):143–50. Pollock FE, Koman LA, Smith BP, et al. Measurement of hand microvascular blood flow with isolated cold stress testing and laser Doppler fluxmetry. J Hand Surg 1993;18(A):143–50.
24.
go back to reference Ruch DS, Vallee J, Li Z, et al. The acute effect of peripheral nerve transection on digital thermoregulatory function. J Hand Surg 2003;28A:481–8. Ruch DS, Vallee J, Li Z, et al. The acute effect of peripheral nerve transection on digital thermoregulatory function. J Hand Surg 2003;28A:481–8.
25.
go back to reference Ruijs ACJ, Jaquet J-B, Daanen HAM, et al. Cold intolerance of the hand measured by the CISS questionnaire in a normative study population. J Hand Surg 2006;31B(5):533–6. Ruijs ACJ, Jaquet J-B, Daanen HAM, et al. Cold intolerance of the hand measured by the CISS questionnaire in a normative study population. J Hand Surg 2006;31B(5):533–6.
26.
go back to reference Santiago S, Ferrer T, Espinosa ML. Neurophysiological studies of thin myelinated (A delta) and unmyelinated (C) fibers: application to peripheral neuropathies. Neurophysiol Clin 2000;30:27–42.PubMedCrossRef Santiago S, Ferrer T, Espinosa ML. Neurophysiological studies of thin myelinated (A delta) and unmyelinated (C) fibers: application to peripheral neuropathies. Neurophysiol Clin 2000;30:27–42.PubMedCrossRef
27.
go back to reference Schlenker JD, Kleinert HE, Tsai T-M. Methods and results of replantation following tramatic amputation of the thumb in sixty-four patients. J Hand Surg 1980;5:63–70. Schlenker JD, Kleinert HE, Tsai T-M. Methods and results of replantation following tramatic amputation of the thumb in sixty-four patients. J Hand Surg 1980;5:63–70.
28.
go back to reference Shy ME, Frohman EM, So YT, et al. Quantitative sensory testing: report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology. Neurology 2003;60(6):898–904.PubMedCrossRef Shy ME, Frohman EM, So YT, et al. Quantitative sensory testing: report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology. Neurology 2003;60(6):898–904.PubMedCrossRef
29.
go back to reference Toibana N, Sakakibara H, Hirata M, et al. Thermal perception threshold testing for the evaluation of small sensory nerve fiber injury in patients with hand–arm vibration syndrome. Ind Health 2000;38(4):366–71.PubMedCrossRef Toibana N, Sakakibara H, Hirata M, et al. Thermal perception threshold testing for the evaluation of small sensory nerve fiber injury in patients with hand–arm vibration syndrome. Ind Health 2000;38(4):366–71.PubMedCrossRef
Metadata
Title
Immersion in Cold-Water Evaluation (ICE) and Self-reported Cold Intolerance are Reliable but Unrelated Measures
Authors
Robyn Traynor
Joy C. MacDermid
Publication date
01-09-2008
Publisher
Springer-Verlag
Published in
HAND / Issue 3/2008
Print ISSN: 1558-9447
Electronic ISSN: 1558-9455
DOI
https://doi.org/10.1007/s11552-008-9085-3

Other articles of this Issue 3/2008

HAND 3/2008 Go to the issue