Skip to main content
Top
Published in: Lasers in Medical Science 4/2014

01-07-2014 | Original Article

Immediate, non-submerged, root-analogue direct laser metal sintering (DLMS) implants: a 1-year prospective study on 15 patients

Authors: Francesco Guido Mangano, Michele De Franco, Alberto Caprioglio, Aldo Macchi, Adriano Piattelli, Carlo Mangano

Published in: Lasers in Medical Science | Issue 4/2014

Login to get access

Abstract

This study evaluated the 1-year survival and success rate of root-analogue direct laser metal sintering (DLMS) implants, placed into the extraction sockets of 15 patients. DLMS is a technology which allows solids with complex geometry to be fabricated by annealing metal powder microparticles in a focused laser beam, according to a computer-generated three-dimensional (3D) model; the fabrication process involves the laser-induced fusion of titanium microparticles, in order to build, layer-by-layer, the desired object. Cone-beam computed tomography (CBCT) acquisition and 3D image conversion, combined with the DLMS process, allow the fabrication of custom-made, root-analogue implants (RAIs). CBCT images of 15 non-restorable premolars (eight maxilla; seven mandible) were acquired and transformed into 3D models: from these, custom-made, root-analogue DLMS implants with integral abutment were fabricated. Immediately after tooth extraction, the RAIs were placed in the sockets and restored with a single crown. One year after implant placement, clinical and radiographic parameters were assessed: success criteria included absence of pain, suppuration, and exudation; absence of implant mobility and absence of continuous peri-implant radiolucency; distance between the implant shoulder and the first visible bone-to-implant contact <1.5 mm from initial surgery; and absence of prosthetic complications. At the 1-year follow-up, no implants were lost, for a survival rate of 100 %. All implants were stable, with no signs of infection. The good conditions of the peri-implant tissues were confirmed by the radiographic examination, with a mean DIB of 0.7 mm (±0.2). The possibility of fabricating custom-made, RAI DLMS implants opens new interesting horizons for immediate placement of dental implants.
Literature
1.
go back to reference Camargos Gde V, do Prado CJ, das Neves FD, Sartori IA (2012) Clinical outcomes of single dental implants with external connections: results after 2 to 13 years. Int J Oral Maxillofac Implants 27:935–944PubMed Camargos Gde V, do Prado CJ, das Neves FD, Sartori IA (2012) Clinical outcomes of single dental implants with external connections: results after 2 to 13 years. Int J Oral Maxillofac Implants 27:935–944PubMed
2.
go back to reference Mangano C, Mangano F, Shibli JA, Tettamanti L, Figliuzzi M, d'Avila S, Sammons RL, Piattelli A (2011) Prospective evaluation of 2,549 Morse taper connection implants: 1- to 6-year data. J Periodontol 82:52–61PubMedCrossRef Mangano C, Mangano F, Shibli JA, Tettamanti L, Figliuzzi M, d'Avila S, Sammons RL, Piattelli A (2011) Prospective evaluation of 2,549 Morse taper connection implants: 1- to 6-year data. J Periodontol 82:52–61PubMedCrossRef
3.
go back to reference Koh RU, Rudek I, Wang HL (2010) Immediate implant placement: positives and negatives. Implant Dent 19:98–108PubMedCrossRef Koh RU, Rudek I, Wang HL (2010) Immediate implant placement: positives and negatives. Implant Dent 19:98–108PubMedCrossRef
4.
go back to reference Kazor CE, Al Shamari K, Sarment DP, Misch CE, Wang HL (2004) Implant plastic surgery: a review and rationale. J Oral Implantol 30:240–254PubMedCrossRef Kazor CE, Al Shamari K, Sarment DP, Misch CE, Wang HL (2004) Implant plastic surgery: a review and rationale. J Oral Implantol 30:240–254PubMedCrossRef
5.
go back to reference Barewal RM, Stanford C, Weesner TC (2012) A randomized controlled clinical trial comparing the effects of three loading protocols on dental implant stability. Int J Oral Maxillofac Implants 27:945–956PubMed Barewal RM, Stanford C, Weesner TC (2012) A randomized controlled clinical trial comparing the effects of three loading protocols on dental implant stability. Int J Oral Maxillofac Implants 27:945–956PubMed
7.
go back to reference Figliuzzi M, Mangano F, Mangano C (2012) A novel root analogue dental implant using CT scan and CAD/CAM: selective laser melting technology. Int J Oral Maxillofac Surg 41:858–862PubMedCrossRef Figliuzzi M, Mangano F, Mangano C (2012) A novel root analogue dental implant using CT scan and CAD/CAM: selective laser melting technology. Int J Oral Maxillofac Surg 41:858–862PubMedCrossRef
8.
go back to reference Mangano FG, Cirotti B, Sammons RL, Mangano C (2012) Custom-made, root-analogue direct laser metal forming implant: a case report. Lasers Med Sci 27:1241–1245PubMedCrossRef Mangano FG, Cirotti B, Sammons RL, Mangano C (2012) Custom-made, root-analogue direct laser metal forming implant: a case report. Lasers Med Sci 27:1241–1245PubMedCrossRef
9.
go back to reference Hodosh M, Povar M, Shklar G (1969) The dental polymer implant concept. J Prosthet Dent 22:371–380PubMedCrossRef Hodosh M, Povar M, Shklar G (1969) The dental polymer implant concept. J Prosthet Dent 22:371–380PubMedCrossRef
10.
go back to reference Lundgren D, Rylander H, Andersson M, Johansson C, Albrektsson T (1992) Healing-in of root analogue titanium implants placed in extraction sockets. An experimental study in the beagle dog. Clin Oral Implants Res 3:136–144PubMedCrossRef Lundgren D, Rylander H, Andersson M, Johansson C, Albrektsson T (1992) Healing-in of root analogue titanium implants placed in extraction sockets. An experimental study in the beagle dog. Clin Oral Implants Res 3:136–144PubMedCrossRef
11.
go back to reference Kohal RJ, Hurzeler MB, Mota LF, Klaus G, Cafessee RG, Strub JR (1997) Custom-made root analogue implants placed into extraction sockets. An experimental study in monkeys. Clin Oral Implants Res 8:386–392PubMedCrossRef Kohal RJ, Hurzeler MB, Mota LF, Klaus G, Cafessee RG, Strub JR (1997) Custom-made root analogue implants placed into extraction sockets. An experimental study in monkeys. Clin Oral Implants Res 8:386–392PubMedCrossRef
12.
go back to reference Kohal RJ, Klaus G, Strubl JR (2002) Clinical investigation of a new dental immediate implant system. The reimplant-system. Deutsch Zahn Z 57:495–497 Kohal RJ, Klaus G, Strubl JR (2002) Clinical investigation of a new dental immediate implant system. The reimplant-system. Deutsch Zahn Z 57:495–497
13.
go back to reference Pirker W, Kocher A (2008) Immediate, non-submerged, root-analogue zirconia implant in single tooth replacement. Int J Oral Maxillofac Surg 37:293–295PubMedCrossRef Pirker W, Kocher A (2008) Immediate, non-submerged, root-analogue zirconia implant in single tooth replacement. Int J Oral Maxillofac Surg 37:293–295PubMedCrossRef
14.
go back to reference Pirker W, Kocher A (2009) Immediate, non-submerged, root-analogue zirconia implants placed into single-rooted extraction sockets: 2-year follow-up of a clinical study. Int J Oral Maxillofac Surg 38:1127–1132PubMedCrossRef Pirker W, Kocher A (2009) Immediate, non-submerged, root-analogue zirconia implants placed into single-rooted extraction sockets: 2-year follow-up of a clinical study. Int J Oral Maxillofac Surg 38:1127–1132PubMedCrossRef
15.
go back to reference Pirker W, Wiedemann D, Lidauer A, Kocher A (2011) Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: a case report with 2.5 years follow up. Int J Oral Maxillofac Surg 40:212–216PubMedCrossRef Pirker W, Wiedemann D, Lidauer A, Kocher A (2011) Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: a case report with 2.5 years follow up. Int J Oral Maxillofac Surg 40:212–216PubMedCrossRef
17.
go back to reference Traini T, Mangano C, Sammons RL, Mangano F, Macchi A, Piattelli A (2008) Direct laser metal sintering as a new approach to fabrication of an isoelastic functionally graded material for manufacture of porous titanium dental implants. Dent Mater 24:1525–1533PubMedCrossRef Traini T, Mangano C, Sammons RL, Mangano F, Macchi A, Piattelli A (2008) Direct laser metal sintering as a new approach to fabrication of an isoelastic functionally graded material for manufacture of porous titanium dental implants. Dent Mater 24:1525–1533PubMedCrossRef
18.
go back to reference Mangano C, Raspanti M, Traini T, Piattelli A, Sammons R (2009) Stereo imaging and cytocompatibility of a model dental implant surface formed by direct laser fabrication. J Biomed Mater Res A 88:823–831PubMedCrossRef Mangano C, Raspanti M, Traini T, Piattelli A, Sammons R (2009) Stereo imaging and cytocompatibility of a model dental implant surface formed by direct laser fabrication. J Biomed Mater Res A 88:823–831PubMedCrossRef
19.
go back to reference Witek L, Marin C, Granato R, Bonfante EA, Campos F, Bisinotto J, Suzuki M, Coelho PG (2012) Characterization and in vivo evaluation of laser sintered dental endosseous implants in dogs. J Biomed Mater Res B Appl Biomater 100:1566–1573PubMedCrossRef Witek L, Marin C, Granato R, Bonfante EA, Campos F, Bisinotto J, Suzuki M, Coelho PG (2012) Characterization and in vivo evaluation of laser sintered dental endosseous implants in dogs. J Biomed Mater Res B Appl Biomater 100:1566–1573PubMedCrossRef
20.
go back to reference Shibli JA, Mangano C, D'avila S, Piattelli A, Pecora GE, Mangano F, Onuma T, Cardoso LA, Ferrari DS, Aguiar KC, Iezzi G (2010) Influence of direct laser fabrication implant topography on type IV bone: a histomorphometric study in humans. J Biomed Mater Res A 93:607–614PubMed Shibli JA, Mangano C, D'avila S, Piattelli A, Pecora GE, Mangano F, Onuma T, Cardoso LA, Ferrari DS, Aguiar KC, Iezzi G (2010) Influence of direct laser fabrication implant topography on type IV bone: a histomorphometric study in humans. J Biomed Mater Res A 93:607–614PubMed
21.
go back to reference Mangano C, Piattelli A, Iezzi G, Mangano F, Raspanti M, Shibli JA, Cassoni A (2011) Scanning electron microscopy (SEM) and X-ray dispersive spectrometry evaluation of direct laser metal sintering surface and human bone interface: a case series. Lasers Med Sci 26:133–138PubMedCrossRef Mangano C, Piattelli A, Iezzi G, Mangano F, Raspanti M, Shibli JA, Cassoni A (2011) Scanning electron microscopy (SEM) and X-ray dispersive spectrometry evaluation of direct laser metal sintering surface and human bone interface: a case series. Lasers Med Sci 26:133–138PubMedCrossRef
23.
go back to reference Mangano C, Mangano F, Shibli JA, Luongo G, De Franco M, Briguglio F, Figliuzzi M, Eccellente T, Rapani C, Piombino M, Macchi A (2012) Prospective clinical evaluation of 201 direct laser metal forming implants: results from a 1-year multicenter study on 62 patients. Lasers Med Sci 27:181–189PubMedCrossRef Mangano C, Mangano F, Shibli JA, Luongo G, De Franco M, Briguglio F, Figliuzzi M, Eccellente T, Rapani C, Piombino M, Macchi A (2012) Prospective clinical evaluation of 201 direct laser metal forming implants: results from a 1-year multicenter study on 62 patients. Lasers Med Sci 27:181–189PubMedCrossRef
24.
go back to reference Mangano C, Mangano F, Shibli JA, Ricci M, Perrotti V, d’Avila S, Piattelli A (2012) Immediate loading of mandibular overdentures supported by unsplinted direct laser metal forming (DLMF) implants. Results from a 1-year prospective study. J Periodontol 83:70–78PubMedCrossRef Mangano C, Mangano F, Shibli JA, Ricci M, Perrotti V, d’Avila S, Piattelli A (2012) Immediate loading of mandibular overdentures supported by unsplinted direct laser metal forming (DLMF) implants. Results from a 1-year prospective study. J Periodontol 83:70–78PubMedCrossRef
25.
go back to reference Heckmann SM, Schrott A, Graef F, Wichmann MG, Weber HP (2004) Mandibular two-implant telescopic overdentures. Clin Oral Implants Res 15:560–569PubMedCrossRef Heckmann SM, Schrott A, Graef F, Wichmann MG, Weber HP (2004) Mandibular two-implant telescopic overdentures. Clin Oral Implants Res 15:560–569PubMedCrossRef
26.
go back to reference Albrektsson T, Zarb GA (1998) Determinants of correct clinical reporting. Int J Prosthodont 11:517–521PubMed Albrektsson T, Zarb GA (1998) Determinants of correct clinical reporting. Int J Prosthodont 11:517–521PubMed
27.
go back to reference Xue W, Krishna BV, Bandyopadhyay A, Bose S (2007) Processing and biocompatibility evaluation of laser processed porous titanium. Acta Biomater 3:1007–1018PubMedCrossRef Xue W, Krishna BV, Bandyopadhyay A, Bose S (2007) Processing and biocompatibility evaluation of laser processed porous titanium. Acta Biomater 3:1007–1018PubMedCrossRef
Metadata
Title
Immediate, non-submerged, root-analogue direct laser metal sintering (DLMS) implants: a 1-year prospective study on 15 patients
Authors
Francesco Guido Mangano
Michele De Franco
Alberto Caprioglio
Aldo Macchi
Adriano Piattelli
Carlo Mangano
Publication date
01-07-2014
Publisher
Springer London
Published in
Lasers in Medical Science / Issue 4/2014
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-013-1299-0

Other articles of this Issue 4/2014

Lasers in Medical Science 4/2014 Go to the issue