01-04-2009 | Original Paper

Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy

Authors: C. Schnurr, J. W. P. Michael, P. Eysel, D. P. König

Published in: International Orthopaedics | Issue 2/2009

Login to get access

Abstract

Surface arthroplasty of the hip is increasingly popular. Optimising the position of the femoral component is essential to avoid early implant failures such as femoral neck fractures. Sixty hip surface replacements were retrospectively analysed. In 30 patients imageless navigation was used, and 30 patients were operated upon using conventional jigs. Accuracy, implant position, operating time, and complications have been recorded. The navigation device improved the implant position with high accuracy. Implant-shaft angles <130° and uncovered cancellous bone of the superior femoral neck could be safely avoided. After a significant learning curve, navigation took 15 minutes longer than conventional implantation. No complications were found in either group. Computer-assisted navigation allowed accurate implantation of the femoral component avoiding pitfalls of hip surface replacement. From our point of view the optimal placement of the femoral component outweighs the disadvantage of a longer operating time.
Literature
1.
go back to reference Amstutz HC, Ball ST, Le Duff MJ, Dorey FJ (2007) Resurfacing THA for patients younger than 50 years: results of 2- to 9-year followup. Clin Orthop Relat Res 460:159–164 Amstutz HC, Ball ST, Le Duff MJ, Dorey FJ (2007) Resurfacing THA for patients younger than 50 years: results of 2- to 9-year followup. Clin Orthop Relat Res 460:159–164
2.
go back to reference Amstutz HC, Beaule PE, Dorey FJ, Le Duff MJ, Campbell PA, Gruen TA (2004) Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study. J Bone Jt Surg Am 86-A:28–39 Amstutz HC, Beaule PE, Dorey FJ, Le Duff MJ, Campbell PA, Gruen TA (2004) Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study. J Bone Jt Surg Am 86-A:28–39
3.
go back to reference Anglin C, Masri BA, Tonetti J, Hodgson AJ, Greidanus NV (2007) Hip resurfacing femoral neck fracture influenced by valgus placement. Clin Orthop Relat Res 465:71–79 Anglin C, Masri BA, Tonetti J, Hodgson AJ, Greidanus NV (2007) Hip resurfacing femoral neck fracture influenced by valgus placement. Clin Orthop Relat Res 465:71–79
4.
go back to reference Beaule PE, Amstutz HC, Le DM, Dorey F (2004) Surface arthroplasty for osteonecrosis of the hip: hemiresurfacing versus metal-on-metal hybrid resurfacing. J Arthroplasty 19:54–58PubMed Beaule PE, Amstutz HC, Le DM, Dorey F (2004) Surface arthroplasty for osteonecrosis of the hip: hemiresurfacing versus metal-on-metal hybrid resurfacing. J Arthroplasty 19:54–58PubMed
5.
go back to reference Beaule PE, Lee JL, Le Duff MJ, Amstutz HC, Ebramzadeh E (2004) Orientation of the femoral component in surface arthroplasty of the hip. A biomechanical and clinical analysis. J Bone Jt Surg Am 86-A:2015–2021 Beaule PE, Lee JL, Le Duff MJ, Amstutz HC, Ebramzadeh E (2004) Orientation of the femoral component in surface arthroplasty of the hip. A biomechanical and clinical analysis. J Bone Jt Surg Am 86-A:2015–2021
6.
go back to reference Beaule PE, Poitras P (2007) Femoral component sizing and positioning in hip resurfacing arthroplasty. Instr Course Lect 56:163–169PubMed Beaule PE, Poitras P (2007) Femoral component sizing and positioning in hip resurfacing arthroplasty. Instr Course Lect 56:163–169PubMed
7.
go back to reference Belei P, Skwara A, De La FM, Schkommodau E, Fuchs S, Wirtz DC, Kamper C, Radermacher K (2007) Fluoroscopic navigation system for hip surface replacement. Comput Aided Surg 12:160–167PubMedCrossRef Belei P, Skwara A, De La FM, Schkommodau E, Fuchs S, Wirtz DC, Kamper C, Radermacher K (2007) Fluoroscopic navigation system for hip surface replacement. Comput Aided Surg 12:160–167PubMedCrossRef
8.
go back to reference Cobb JP, Kannan V, Brust K, Thevendran G (2007) Navigation reduces the learning curve in resurfacing total hip arthroplasty. Clin Orthop Relat Res 463:90–97 Cobb JP, Kannan V, Brust K, Thevendran G (2007) Navigation reduces the learning curve in resurfacing total hip arthroplasty. Clin Orthop Relat Res 463:90–97
9.
go back to reference Daniel J, Pynsent PB, McMinn DJ (2004) Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. J Bone Jt Surg Br 86:177–184CrossRef Daniel J, Pynsent PB, McMinn DJ (2004) Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. J Bone Jt Surg Br 86:177–184CrossRef
10.
go back to reference Davis ET, Gallie P, Macgroarty K, Waddell JP, Schemitsch E (2007) The accuracy of image-free computer navigation in the placement of the femoral component of the Birmingham hip resurfacing: a cadaver study. J Bone Jt Surg Br 89-B:557–560CrossRef Davis ET, Gallie P, Macgroarty K, Waddell JP, Schemitsch E (2007) The accuracy of image-free computer navigation in the placement of the femoral component of the Birmingham hip resurfacing: a cadaver study. J Bone Jt Surg Br 89-B:557–560CrossRef
11.
go back to reference Hess T, Gampe T, Kottgen C, Szawlowski B (2004) Intraoperative navigation for hip resurfacing. Methods and first results. Orthopade 33:1183–1193PubMedCrossRef Hess T, Gampe T, Kottgen C, Szawlowski B (2004) Intraoperative navigation for hip resurfacing. Methods and first results. Orthopade 33:1183–1193PubMedCrossRef
12.
go back to reference Hodgson AJ, Inkpen KB, Shekhman M, Anglin C, Tonetti J, Masri BA, Duncan CP, Garbuz DS, Greidanus NV (2005) Computer-assisted femoral head resurfacing. Comput Aided Surg 10:337–343PubMedCrossRef Hodgson AJ, Inkpen KB, Shekhman M, Anglin C, Tonetti J, Masri BA, Duncan CP, Garbuz DS, Greidanus NV (2005) Computer-assisted femoral head resurfacing. Comput Aided Surg 10:337–343PubMedCrossRef
13.
go back to reference Kruger S, Zambelli PY, Leyvraz PF, Jolles BM (2007) Computer-assisted placement technique in hip resurfacing arthroplasty: improvement in accuracy? Int Orthop 24 Aug 2007. Epub ahead of print Kruger S, Zambelli PY, Leyvraz PF, Jolles BM (2007) Computer-assisted placement technique in hip resurfacing arthroplasty: improvement in accuracy? Int Orthop 24 Aug 2007. Epub ahead of print
14.
go back to reference Laskin RS, Beksac B (2006) Computer-assisted navigation in TKA: where we are and where we are going. Clin Orthop Relat Res 452:127–131PubMedCrossRef Laskin RS, Beksac B (2006) Computer-assisted navigation in TKA: where we are and where we are going. Clin Orthop Relat Res 452:127–131PubMedCrossRef
15.
go back to reference Little JP, Taddei F, Viceconti M, Murray DW, Gill HS (2007) Changes in femur stress after hip resurfacing arthroplasty: response to physiological loads. Clin Biomech 22:440–448CrossRef Little JP, Taddei F, Viceconti M, Murray DW, Gill HS (2007) Changes in femur stress after hip resurfacing arthroplasty: response to physiological loads. Clin Biomech 22:440–448CrossRef
16.
go back to reference Long JP, Bartel DL (2006) Surgical variables affect the mechanics of a hip resurfacing system. Clin Orthop Relat Res 453:115–122PubMedCrossRef Long JP, Bartel DL (2006) Surgical variables affect the mechanics of a hip resurfacing system. Clin Orthop Relat Res 453:115–122PubMedCrossRef
17.
go back to reference Martin A, Wohlgenannt O, Prenn M, Oelsch C, Strempel A (2007) Imageless navigation for TKA increases implantation accuracy. Clin Orthop Relat Res 460:178–184PubMed Martin A, Wohlgenannt O, Prenn M, Oelsch C, Strempel A (2007) Imageless navigation for TKA increases implantation accuracy. Clin Orthop Relat Res 460:178–184PubMed
18.
go back to reference McMinn D, Treacy R, Lin K, Pynsent P (1996) Metal on metal surface replacement of the hip. Experience of the McMinn prosthesis. Clin Orthop Relat Res 329:S89–S98PubMedCrossRef McMinn D, Treacy R, Lin K, Pynsent P (1996) Metal on metal surface replacement of the hip. Experience of the McMinn prosthesis. Clin Orthop Relat Res 329:S89–S98PubMedCrossRef
19.
go back to reference Morlock MM, Bishop N, Ruther W, Delling G, Hahn M (2006) Biomechanical, morphological, and histological analysis of early failures in hip resurfacing arthroplasty. Proc Inst Mech Eng 220:333–344CrossRef Morlock MM, Bishop N, Ruther W, Delling G, Hahn M (2006) Biomechanical, morphological, and histological analysis of early failures in hip resurfacing arthroplasty. Proc Inst Mech Eng 220:333–344CrossRef
20.
go back to reference Radcliffe IA, Taylor M (2007) Investigation into the effect of varus-valgus orientation on load transfer in the resurfaced femoral head: a multi-femur finite element analysis. Clin Biomech 22:780–786CrossRef Radcliffe IA, Taylor M (2007) Investigation into the effect of varus-valgus orientation on load transfer in the resurfaced femoral head: a multi-femur finite element analysis. Clin Biomech 22:780–786CrossRef
21.
go back to reference Shimmin AJ, Back D (2005) Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases. J Bone Jt Surg Br 87:463–464CrossRef Shimmin AJ, Back D (2005) Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases. J Bone Jt Surg Br 87:463–464CrossRef
22.
go back to reference Siston RA, Giori NJ, Goodman SB, Delp SL (2007) Surgical navigation for total knee arthroplasty: a perspective. J Biomech 40:728–735PubMedCrossRef Siston RA, Giori NJ, Goodman SB, Delp SL (2007) Surgical navigation for total knee arthroplasty: a perspective. J Biomech 40:728–735PubMedCrossRef
23.
go back to reference Treacy RB, McBryde CW, Pynsent PB (2005) Birmingham hip resurfacing arthroplasty. A minimum follow-up of five years. J Bone Jt Surg Br 87:167–170CrossRef Treacy RB, McBryde CW, Pynsent PB (2005) Birmingham hip resurfacing arthroplasty. A minimum follow-up of five years. J Bone Jt Surg Br 87:167–170CrossRef
Metadata
Title
Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy
Authors
C. Schnurr
J. W. P. Michael
P. Eysel
D. P. König
Publication date
01-04-2009
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 2/2009
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-007-0494-7

Other articles of this Issue 2/2009

International Orthopaedics 2/2009 Go to the issue